NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

Similar documents
PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

DOROT CONTROL VALVES CATALOGUE

MODULATING FLOAT CONTROL VALVE

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

PRESSURE REDUCING CONTROL VALVES

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

FLOAT CONTROL VALVES

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Pneumatics, Automation & Control Solutions

SOLENOID CONTROL VALVE

Installation, Operation and Maintenance Instructions

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

ELECTRIC & HYDRAULIC VALVES

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

4 - Way Control 4 - Way Control 4 - Way Control with lock

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Colt Series C400, C500

Series 867 Reduced Pressure Zone Assemblies

HYDRAULIC CONTROL VALVES

Valve Operation Guide

Three Way Pilot Control

updated 09/2010 Series 100 Valves

Pilot-Operated Regulators

FLOW METERS FOR MINING

HYDROMETERS OPERATION, INSTALLATION & MAINTENANCE GUIDE

INSTALLATION & MAINTENANCE MODEL mm

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

Type 644 and 645 Differential Pressure Pump Governors

Series 95/96 upvc Valves

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

THIS WARRANTY IS IN LIEU

ARIES THINWALL DRIPLINE

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

Operation and Maintenance Manual

CAST IRON VALVES PRESSURE REDUCING VALVES SERIES

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Structural Simplicity and Superior Hydraulic Performance. Valve Operation Guide

Fisher 644 and 645 Differential Pressure Pump Governors

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Adjustable Differential Relay A1

DT34 and DT54 Series Rotary Sprinklers

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Super Gal. Super Gal. Model 75 - High Capacity Plastic Control Valve. Product Catalogue. Super Gal Catalogue. Model 75.

Baumann Mikroseal Control Valve

Distributed By: M&M Control Service, Inc KO/650-01KO

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

Instructions for Installation, Operation, Care and Maintenance

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

OPERATING AND MAINTENANCE MANUAL

Deep Well Pump Control Valve

OBSOLETE DOCUMENT. PRX Series Pilots for Pilot-Operated Pressure Reducing Regulators. PRX Series. Introduction. Product Description

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

Introduction. Installation. Maintenance. Bill of Materials

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

DT35 and DT55 Series Rotary Sprinklers Installation & Service Instructions

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

GBP784B INSTALLATION TOOL

P99 Pressure Reducing Regulator

INSTALLATION / OPERATION / MAINTENANCE MODEL SERVICE AND MAINTENANCE OF 600 SERIES VALVES UNDERSTANDING THE 600 SERIES VALVES

Deluge Pressure Reducing Valves. Model 68 DE\ EL\ PORV\ PR. Electrically and Pneumatically Actuated, Pressure Reducing, Remote-Reset, Deluge Valve

800SVRM-7 5/04 RATE-OF-FLOW CONTROL 800 SERIES CONTROL VALVES

BERMAD Waterworks. BERMAD 700 Large Size Series. 700 Series. Features and Options. Model: 700-M5, 700-M6, 700-M5L

Worldwide Contacts.

TYPE E Main Valve Sizes 3 /8 through 12

700 LARGE SIZE SERIES

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Series 009. Reduced Pressure Zone Assemblies. Installation Service Repair Kits Maintenance. Sizes: 8 80mm. 80mm 009LF RP/IS-009-AUS

Pilot Valves Catalogue

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

HALLMARK INDUSTRIES INC

SERIES 20L FLOWGRID TM PILOTS INSTALLATION / OPERATION / MAINTENANCE MANUAL

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

REPAIR PROCEDURES MANUAL

Installation, Maintenance, & Repair Series 919 and LF919

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

EZH and EZHSO Series. Pressure Reducing Regulators. EZH and EZHSO Series. Introduction. Scope of the Manual. Product Description !

Techcon Systems TS5620 Series Diaphragm Valve. User Guide

Air Operated 1:1 Oil Ratio Pump OP-11

Transcription:

MINING DIVISION NYLON & PVC VALVES PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE NYLON For Gold Mines DESCRIPTION The valve maintains a preset downstream pressure, regardless of upstream pressure or flow rate fluctuation. The main valve is controlled by a 3-way pilot, allowing full opening when the pressure drops below a downstream pressure set-point. FEATURES & BENEFITS Accurate, stable control from no-flow to full-flow. Exceptionally low head losses at high flows. High resistance to corrosive water and other acid media (including 3-way pilot). Simple to install - manufactured with threaded or socket (slip) connections. Simple and reliable design - diaphragm is the only moving component. Shaft, seals or bearings are not located within the water s passage way. PURCHASE SPECIFICATIONS Hydraulic valve with direct sealing flexible diaphragm. Inline maintenance. Stem, shaft or guide bearing are not located within the water passage. PVC For Gold and Copper Mines Activated by the line pressure or by an external hydraulic or pneumatic pressure. Operated by a pressure reducing pilot valve to achieve constant outlet pressure, regardless of upstream pressure or flow variations. Valve and the controls are Netafim Series 61PRXPLS (X is used to signify size of valve - 3, 4, 6, etc.). QUICK SIZING Valve size same as line size or one size smaller. Maximum flow speed for continuous operation of 18 ft/sec. DESIGN CONSIDERATIONS The valve should be suited for the maximal flow and allowed headloss. Large pressure differentials may cause cavitation damage. Consult with Netafim if such conditions are expected.

PVC VALVE SPECIFICATIONS Light brown area indicates recommended operating range. *Refers to a 2 Valve with a 3 inlet/outlet. Flow (GPM) 50 60 80 100 150 200 300 400 500 700 900 1300 1700 1 1.5 2 Headloss (psi) 3 4 5 2" 1 ½" 6 2 ½" 4" 6" 323* 3" 3-WAY CONTROL MODEL HEADLOSS

PVC VALVE SPECIFICATIONS NYLON & PVC VALVE DIMENSIONS AND WEIGHTS NYLON PVC Connection Threaded Threaded Slip Size 1 1 /2 2 323* 3 3 4 6 Length 7 3 /8 7 3 /8 9 1 /4 10 1 /8 10 1 /8 11 14 Height 4 3 /4 4 3 /8 4 3 /4 7 5 /8 7 5 /8 8 15 Weight (lbs) 2 2.2 3.1 9.3 9.3 9.5 20 *Refers to a 2 valve with 3 inlet and outlet MAXIMUM RECOMMENDED FLOW RATES (GPM) 1 ½ 2 323* 3 4 6 90 175 225 395 600 1,300 *Refers to a 2 valve with 3 inlet and outlet PVC MODELS Size Threaded Slip 3 3 3 4-3 6-3 SPECIFICATIONS* Nylon Valve Operating Pressure: - Maximum pressure: 145 psi (10 bar) - Minimum pressure: 8 psi (0.6 bar) 3 and 4 PVC Valve Operating Pressure: - Maximum pressure: 115 psi (8 bar) - Minimum pressure: 8 psi (0.6 bar) 6 PVC Valve Operating Pressure: - Maximum pressure: 145 psi (10 bar) - Minimum pressure: 8 psi (0.6 bar) Maximum water temperature: - 100 F at maximum pressure *Pressure refers to upstream pressure AVAILABLE SIZES: 1.5-6 FUNCTION The Pressure Reducing Valve shall maintain a constant downstream pressure regardless of changing flow rate and/or inlet pressure. Valve should be able to operate properly at ph=1. MAIN VALVE The valve shall be hydraulically operated, diaphragm actuated, direct flexible diaphragm sealing, weir type. The valve shall consist of three major components: the body, with no seats installed; the cover, with no bearings installed; and the diaphragm assembly (diaphragm, spring and spring seat). The diaphragm assembly shall be the only moving part and shall form a sealed chamber in the upper portion of the valve, separating operating pressure from line pressure. There shall be no pistons operating the main valve, no shafts, or discs as the sealing mechanism of the main valve. MAIN VALVE BODY No separate chambers shall be allowed between the main valve cover and body. Valve body and cover shall be of Glass Reinforced Polyamide (GRP or Nylon ) or PVC. No discs will be permitted as seating surface neither O-ring type discs (circular, square, or quad type) shall be permitted as the seating surface. No disc guides shall be permitted. No disc retainers shall be permitted. No V-type or U-type slotted type disc guides shall be used.

PVC VALVE SPECIFICATIONS The diaphragm assembly should contain no stems or bearings in the valve cover and/or the valve seat. No center guides shall be permitted. The sealing mechanism should not be guided in any way. The flexible diaphragm shall consist of nylon fabric bonded with synthetic rubber compatible with the operating fluid and resistant to ph =1 for the length of the warranty terms. All necessary repairs and/or modifications other than replacement of the main valve body shall be possible without removing the valve from the pipeline. The valve manufacturer shall warrant the valve body to be free of defects in material and workmanship for a period of five years from date of shipment, provided the valve is installed and used in accordance with all applicable instructions. The valve manufacturer shall be able to supply a complete line of equipment from 1.5 through 6 sizes and a complete selection of complementary equipment. The valve manufacturer shall also provide a computerized cavitation chart with flow rate, differential pressure, Cv factor, system velocity, and possibility of cavitation damage. PILOT CONTROL SYSTEM The pressure reducing pilot control shall be a direct-acting, adjustable, spring-loaded, 3-way pilot design to vent the control chamber of the main valve to the atmosphere when the downstream pressure decreases below a certain setpoint. The pilot control is held open by the force of the compression on the spring above the diaphragm, and it closes when the delivery pressure acting on the underside of the diaphragm exceeds the spring setting. No orifices shall be permitted in the pilot circuit. A full range of spring settings shall be available in ranges up to 90 psi. The materials of the pilot and pilot control systems shall be compatible with the operating fluid and resistant to ph=1, such as stainless steel and rubber. MATERIAL SPECIFICATION FOR PILOT CONTROL: Pressure Rating: up to 90 psi Diaphragm Assembly: Natural Rubber Tubing and Fittings: Plastic Adjustment Bolt and Locking Nut: SST Spring: SST Operating Fluids: ph=1 and higher PRESSURE REDUCING VALVE MATERIAL SPECIFICATION Model Description Material 61BXPL-S Valve Basic X PVC Slip Connection PVC 61PILPLSSS Pilot PR/PS Blue Plastic 61SF25P In-line Filter Plastic 1 /4 x 2 3 /8 Plastic 55P4684802 Plastic Male Connector 8mm x 1 /8 Plastic 55P4694802 Plastic Male 90-Elbow 8mm x 1 /8 Plastic 55P4694804 Plastic Male 90-Elbow 8mm x 1 /4 Plastic 15CONT-6-1 PE Control Tube 8mm PE 55P1200202 Plastic Adapter 1 /8 Male x Female Plastic NA** Adjusting Bolt Stainless Steel NA** Manual Selector Stainless Steel NA** 1/8 Male x 8mm x 1 /8 Male Plastic 55P1220204 Plastic Nipple 1 /4 Plastic 55P4714802 Plastic Male Round Tee 8mm x 1 /8 x 8mm Plastic *X indicates size of valve. **For more information call Netafim Customer Service at 888-638-2346.

OPERATING INSTRUCTIONS The Netafim PVC Valve for Mining Series 61PRXPLS (when x represents the size of the valve - 1.5, 2, 2.5, 3, 4, 6 ) is an automatic control valve designed to reduce higher inlet pressure to a constant lower downstream pressure regardless of changing flow rate and/or inlet pressure. The valve is a hydraulically operated, pilot-controlled, diaphragm type globe valve. When downstream pressure exceeds the pressure set point of the control pilot, the main valve closes. The control system is very sensitive to slight pressure changes and immediately controls the main valve to maintain the desired downstream pressure. Pressure setting adjustment is made with a single adjusting bolt. INSTALLATION 1. Allow sufficient room around the valve assembly for adjustments and servicing. 2. Before the valve is installed, pipe lines should be flushed of all chips, scale and debris. 3. Place the valve assembly in the line of flow through the valve in the direction indicated by the flow arrow. Check that all fittings and hardware are in proper condition and that no apparent damage is evident. Be sure main valve cover nuts/bolts are tight. Pressure in some applications can be very high, thoroughly check and inspect for proper installation and makeup. 4. Valve s bonnet should be installed in top (vertical) position, except for 6 valves bonnet should be installed in side (horizontal) position (see drawings below). This makes periodic inspection of internal parts easily accessible. START-UP AND OPERATION 1. Prior to pressurizing the valve assembly make sure the necessary gauges to measure pressure in the system are installed as required by the system engineer. Caution: During start-up and test procedures a large volume operating fluid may be discharged downstream. Check that the downstream venting is adequate to prevent damage to personnel and equipment. Under flowing conditions all pressure adjustments should be made slowly. If the main valve closes too fast it may cause surging in upstream pressure. 2. Adjust the control pilot to desired pressure. To increase pressure, turn the adjusting screw clockwise. To decrease pressure, turn counterclockwise. There must be fluid flowing through the valve during pressure adjustments. When the desired setting has been made, tighten locking nut at the pilot. MAINTENANCE 1. Netafim Valves and Controls require no lubrication or packing and a minimum of maintenance. However, a regular inspection schedule should be established, at a minimum of once per year. 2. When ordering parts always refer to the model number and item number on the valve nameplate. BONNET BONNET VERTICAL TOP POSITION HORIZONTAL SIDE POSITION

TROUBLESHOOTING PROBLEM CAUSE REMEDY Main valve fails to open. Valve does not close. Insufficient pressure at valve inlet. Pilot is not opening. (2)* Manual selector is closed. (10)** Punctured diaphragm. Foreign substance on sealing seat. Faulty pilot. Check inlet pressure, increase as needed. No spring compression - tighten adjusting screw. Open manually. Replace diaphragm. Refer to I.D. number. Dismantle, clean and reassemble. Disassemble and remove obstructions. Replace internal parts or pilot. Valve does not regulate. Unstable performance. Incorrect connections. Wrong spring in pilot. Inlet pressure too low. Clogged filter. Faulty pilot. Extreme low flow or high pressure differential. Change according to schematics. Change according to supporting material. Increase pressure. Clean or replace. Clean pilot or replace. Install dripper or needle valve at vent port of the pilot. *See #2 callout on exploded drawing on Valve Description page. **See #10 callout on exploded drawing on Valve Description page.

VALVE DESCRIPTION PRESSURE REDUCING VALVE, PVC FOR MINING, PART NUMBER 61PRXPLS-YM 9 2 5 5 8 11 4 7 6 12 10 6 7 13 3 6 1 NO. QTY. MODEL DESCRIPTION 1 1 61B*XPL-S Valve Basic *X PVC Slip Connection 2 1 61PILPLSSS Pilot PR/PS Blue Stainless Steel 3 1 61SF25P In-line Filter Plastic 1 /4 x 2 3 /8 4 1 55P4684802 Plastic Male Connector 8MM x 1 /8 5 4 55P4694802 Plastic Male 90-Elbow 8MM x 1 /8 6 3 55P4694804 Plastic Male 90-Elbow 8MM x 1 /4 7 3 15CONT-8-I PE Control Tube 8MM 8 1 55P1200202 Plastic Adapter 1 /8 Male x Female 9 1 NA** Adjusting Bolt 10 1 NA** Manual Selector 11 1 NA** 1/8 Male x 8mm x 1 /8 Male 12 1 55P1220204 Plastic Nipple 1 /4 13 1 55P4714802 Plastic Male Branch Tee 8mm x 1 /8 x 8mm *X indicates size of valve. **For more information call Netafim Customer Service at 888-638-2346.

NETAFIM USA 5470 E. Home Ave. Fresno, CA 93727 CS 888 638 2346 www.netafimusa.com M044 03/13