Welcome to the Dekati/ExIS/ Pegasor seminar Peter Ahlvik

Similar documents
Application of the. to NRMM. Alois Krasenbrink European Commission

Future Powertrain Conference 24 th February C 2016 HORIBA Ltd. All rights reserved.

PMP HD Validation Exercise and Round Robin

Update on the UN-ECE GRPE Particle Measurement Programme Spring 2009

Investigation of the Feasibility of Achieving Euro VI Heavy-Duty Diesel Emissions Limits by Advanced Emissions Controls

Update on the UN-ECE Particle Measurement Programme (PMP)

Performance of HORIBA-SPCS in the PMP LDD ILCE

Automotive Particle Emissions: an update of regulatory Euro 6/VI and UNECE developments

First results of vehicle technology effects on sub-23nm exhaust particle number emissions using the DownTo10 sampling and measurement system

TSI PTI-Prototype for PN- Periodic Technical Inspection

PMP Comparison Study of Particle Measurement Systems

AECC Non-Road Mobile Machinery (NRMM) Test Programme: Particle Measurement and Characterisation

AVL Particle Measurement System Aviation

Real Driving Emissions and Test Cycle Data from 4 Modern European Vehicles

Euro VI Programme and Emissions Results on European Cycles

Dekati Solutions. Engine Emissions

Development & Implementation of Particle Number Measurement for Vehicle Emissions Regulation

Real Driving Emissions

14 th ETH-Conference on Combustion Generated Nanoparticles Zurich, Switzerland August 1 st -4 th 2010

Correlation between Pegasor Particle Sensor and Particle Number Counter Application of Pegasor Particle Sensor in Heavy Duty Exhaust

AECC HEAVY DUTY NRMM TEST PROGRAMME: PARTICLE MEASUREMENT AND CHARACTERISATION

Reducing diesel particle emissions by particle oxidation catalyst

76th UNECE GRPE session

Solid Particle Emissions of HDV Euro 3 DPF Euro 4 PM-Kat Euro 5 SCR

Harmonised and Non-road Cycles from

Product Portfolio Nanoparticle. (Stand: April 2016)

Study of Fuel Oxygenate Effects on Particulates from Gasoline Direct Injection Cars

Particulate emissions from vehicles: contribution of research to EU policy development

Particle Emission Reduction in a SI-DI Vehicle by an Open Channel Filter

Transient high sensitive soot measurement. AVL Micro Soot Sensor. Manfred Linke

SUREAL-23 UNDERSTANDING, MEASURING AND REGULATING SUB-23 NM PARTICLE EMISSIONS FROM DIRECT INJECTION ENGINES INCLUDING REAL DRIVING CONDITIONS

Development of vehicle emission factors using PEMS

Particle number emission limits for Euro 6 positive ignition vehicles (PI)

Testing of particulate emissions from positive ignition vehicles with direct fuel injection system. Technical Report

EU-PEMS PM EVALUATION PROGRAM - First Report

COMPARISON OF FULL FLOW DILUTION, PARTIAL FLOW DILUTION, AND RAW EXHAUST PARTICLE NUMBER MEASUREMENTS

SOOT SENSOR FOR EMISSION ONBOARD CONTROL SYSTEMS

2018 HORIBA, Ltd. All rights reserved. 1

New Catalytic Stripper System for the Measurement of Solid Particle Mass, Number, and Size Emissions from Internal Combustion Engines

European Emissions Legislation Update

74th UNECE GRPE session

Real time measurements of ash particle emissions. David Kittelson, David Gladis, and Winthrop Watts

Test procedure and Specifications for Particle Number Portable Emissions Measurement Systems (PN-PEMS)

UPDATE PTI PROCEDURE FOR DPF TESTING

Prospects of meeting EU number emission standards with a diesel engine without a DPF

AECC/Concawe 2016 GPF RDE PN Test Programme: PN Measurement Above and Below 23nm

Roadworthiness Test Investigations of Diesel Particulate Filters

WNTE: A regulatory tool for the EU? GRPE Meeting of the Off-Cycle Emissions Working Group. Geneva, June 2006

EVALUATION OF THE EUROPEAN PMP METHODOLOGIES USING CHASSIS DYNAMOMETER AND ON-ROAD TESTING OF HEAVY- DUTY VEHICLES

Particle Sensor Performance & Durability for OBD Applications & Beyond

Overview of Laboratory Testing for Engine Certifications

Scientific Publications

Particulate Emissions from Typical Light-Duty Vehicles taken from the European Fleet, Equipped with a Variety of Emissions Control Technologies

AVL EMISSION TEST SYSTEMS International sight of future emission programs K. Engeljehringer AVL List GmbH, Graz, Austria

Particle Sensor Performance & Durability for OBD Applications & Beyond

Introduction to Particulate Emissions 1. Gasoline Engine Particulate Emissions Introduction 3. References 7 About the Authors 8

DaimlerChrysler Alternative Particulate Measurement page 1/8

Technical Committee Motor Vehicles 15 September RDE 3 discussion

Implementation and Challenges of RDE with BSVI Norms

Introduction of measurement technics regarding mass emissions and real time fuel consumption using direct exhaust gas flow meter

Real Driving Emissions of a GPF-equipped production car

Paper-Abstract Form. Title: Reduction of exhaust nanoparticles by retrofitted after-treatment systems in diesel passenger cars

Characterization of particle emissions from a marine diesel engine: Influence of sampling temperature on particle number, size, and morphology

PEMS-PM Pre-Pilot Program

EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL

New results from a 2015 PEMS testing campaign on a Diesel Euro 6b vehicle

Technology (CE-CERT), Riverside, CA Minneapolis, MN 55455

Heavy-Duty Diesel Engine Trends to Meet Future Emissions Standards (Euro VI)

CHARACTERIZATION OF ATMOSPHERIC DISPERSING EXHAUST PLUME DURING ON- ROAD OPERATION OF LATEST TECHNOLOGY HEAVY-DUTY TRUCKS

Diesel exhaust nanoparticle volatility studies by a new thermodenuder with low solid nanoparticle losses

Subject: ACEA proposal for Euro 6 OBD and Euro 6 PN limit for gasoline direct injection engines.

Technologies for Heavy-duty Engines

New TSI Instrumentnanoparticle emissions tester is a tool for measuring the total solid number concentration of particulate matter from combustion

Swedish In-Service Testing Program

RDE PN emissions from a GDI vehicle without and with a GPF

Particle Size Distribution Measurements from Early to Late Injection Timing Low Temperature Combustion

E. Rodt 2 UBA Berlin Berlin Germany. EU / GRPE: "Particulate measurement program" (PMP)

Fuel Properties Effects on Current Diesel Vehicle Technology Emission

DETERMINATION OF A PRECONDITIONING PROTOCOL TO STABILIZE NOx AND PN EMISSIONS FOR EURO 6 ENGINE CERTIFICATION

On-Road Measurements of Spark Ignition Nanoparticle Emissions

Sousuke Sasaki, Yoshio Tonegawa Japan Automobile Research Institute. 17th August th International ETH-Conference on JARI

PARTICULATES Plenary Meeting

The Future of Vehicle Emissions Regulation in the EU and Internationally

expectations towards Euro VI AECC Technical Seminar Brussels, 25 th October 2007

Black Carbon Emissions From Diesel Engines - Technical And Policy Options For Reduction. Dr Richard O Sullivan 22 March 2012

Emissions from Tractors and Non-Road Mobile Machinery Engines

EU emissions regulations: An Update

TEST REPORT. Swedish In-Service Testing Programme 2010 on Emissions From Heavy-Duty Vehicles

Recent Advances in Measurement Technology for Low Particulate Emissions in A Legislative Framework

REAL WORLD DRIVING. Fuel Efficiency & Emissions Testing. Prepared for the Australian Automobile Association

An Analysis of DISI Particle Morphology

Test Engine. torque [Nm] power [kw] speed [rpm] Liebherr Dieselmotor 934 S A6 4 Cylinders Turbodiesel, intercooler, unit pump, EDC

Gasoline LDV. Toyota Corolla 1.8 (Euro III) Peugeot 106 (Euro I) Golf TDI 1.9 w/ cat (Euro II) With adapted test protocol for traps

on Emissions from Non-Road Mobile Machinery

UNECE HDDF-TF status report

Real-Driving Emissions test programme results from a Plugin Hybrid Electric Vehicle (PHEV)

The new Iran Heavy Duty Diesel Environmental Regulation

GDI measurements with a Fast Particulate Spectrometer

Expected Light Duty Vehicle Emissions from Final Stages of Euro 6

I. Ježek et al. Correspondence to: I. Ježek and G. Močnik

Transcription:

Welcome to the Dekati/ExIS/ Pegasor seminar 2010-05-24 Peter Ahlvik

ExIS AB Exhaust Instruments Scandinavia ExIS AB is a Swedish-based company that offers equipment for particle measurements and measurement and consultant services on the Scandinavian market 2010-05-24 Legislation and trends 2

Partners and network Instrument and equipment suppliers Control Sistem, Italy CVS (full, mini, micro), driving robot Dekati, Finland Particle instruments & dilution Ecomesure, France Distributor, PMP instrument Grimm Aerosol, Germany Particle instruments Matter Engineering, Switzerland Dilution and particle instruments Pegasor, Finland Pegasor Particle sensor (PPS) Topas, Germany Aerosol generators, filter testing 2010-05-24 Legislation and trends 3

Automotive legislation and market trends Peter Ahlvik

PM (mg/km) Overview of measurement technologies Legislative test methods R&D purpose PM PN CPC Σ 5.0 4.0 3.0 2.0 1.0 0.0 4.3 NEDC Various principles Real-time PM, PN, Size distribution Volatile/solid Elemental composition PAH content etc 2010-05-24 Legislation and trends 5

Direct injection for otto engines Wall and air motion guided A/F prep. Late injection, stratified charge. Early injection, homogenous charge Spray controlled A/F prep. Late injection, stratified charge 2010-05-24 Legislation and trends 6

Particle mass emissions in the PMP test programme Euro 5: 4,5 mg 2010-05-24 Legislation and trends 7

Particle number emissions in the PMP test programme Euro 5-6: 6x10 11 2010-05-24 Legislation and trends 8

HD Euro VI (Reg. (EC) No 595/2009) some open issues New driving cycles (WHTC, WHSC), April 2010 Technical Regulation (comitology) not ready OBD system to control real-world emiss. Tamper-free consumable reagent system NO 2 component of NO X (if applicable) Retrofitting issues (e.g. NO 2 of NO X ) PN limit (April 2010) and measurement methodology Off cycle emissions & PEMS 2010-05-24 Legislation and trends 9

Emission limit values for HD Euro VI Cycle and engine type Limit values (mg/kwh, ppm, #/kwh) CO THC NMHC CH 4 NO X NH 3 PM PN ESC (CI) 1,5 130 400 10 10 Set by ETC (CI) 4,0 160 400 10 10 April 2010 ETC (PI) 4,0 160 500 400 10 10 WHSC --- Set by April 2010 --- WHTC --- Set by April 2010 --- 2010-05-24 Legislation and trends 10

Particulate Measurement Programme PMP Peter Ahlvik

Particle number (PN) emission limits Mass limit not considered sufficient The Particle Measurement Programme (PMP) was initiated by EU to develop new measurement methods and set limits Solid particle total number limit was desired due to anticipated health effects Enforced gradually in Euro 5 & 6 limits in the timeframe 2009-2015 (diesel first) 2010-05-24 Legislation and trends 12

Typical size distribution of exhaust aerosol 23 nm cutoff nuclei mode condensed Nuclei mode is highly variable with CVS sampling conditions accumulation mode Soot Coarse mode Source: Kittelson et al. 2002 2010-05-24 Legislation and trends 13

PMP sampling and dilution Dilution tunnel Venturi AC & HEPA PND2 cold Evaporation tube, 350ºC PND1 hot CPC VPR: Volatile Particle Remover 2010-05-24 Legislation and trends 14

PMP approach some intentions CVS tunnel preferred sampling point CVS sis well-know by industry and agencies Thermodenuder not preferred Losses would be too high Consumables (and risk of overloading) Thermodilution is the preferred solution! CPC preferred for number counting Highest sensitivity Early drafts: very detailed geometry requirements 2010-05-24 Legislation and trends 15

PMP outcome CVS, results o Losses in mini dilution systems lower than CVS o Micro dilution systems probably even better Thermodilution, results o Similar losses as a Thermodenuder w. RD (!!!) o High DR TD consumables would be low CPC still the only accepted option for counting o Needs very high DR due to low max. conc. o Alternatives cannot be used for homologation o Not suitable for on-board measurements (PEMS) Final: regulates function rather than geometry; recommendations have been included 2010-05-24 Legislation and trends 16

Particle penetration [%] Particle penetrations for various alternative PMP dilution systems 100% 95% 90% 85% P (30 nm) P (50 nm) P (100 nm) 95% 90% 88% 86% 83% 100% 98% 96% 80% 75% 70% 65% 71% 68% 65% 70% 71% 72% 60% 55% 50% 52% Competitor A Competitor B1 Competitor B2 EMPA homemade DEED Source: PMP ILCE_HD final report 2010-05-24 Legislation and trends 17

HD PMP test results on CVS and partial dilution background vs. engine PM 2010-05-24 Legislation and trends 18

Actual vs. real particle level Scematic impact of preconditioning (i.e. clean/dirty dilution tunnel) 300% 250% Clean tunnel Dirty tunnel 200% 150% 100% 50% 0% Time 2010-05-24 Legislation and trends 19

RS-PMP measurement system for automotive particle number meas. Based on proven components Substantial simplification Very low particle losses DR: 1:100 1:2 000 (1:10; 1:80 000) Pre-DPF sampling option Touch screen PC control with simple interface +AK protocol Successful tests at several sites Further developments... 2010-05-24 Legislation and trends 22

Trends in PMP measurements PN with size distr. instr., e.g.: ELPI: exclude < 30 nm channel DMS500: numerical data treatment DMM-230A: calibration Simpler principles: Nanomet III: Diffusion battery Pegasor: PPS-M Key point is that no CPC is used PN for PEMS measurements to be developed 2010-05-24 Legislation and trends 24

Some bold statements about PMP for further discussion Automotive manufacturers will invest in PMP instruments in every test cell Automotive manufacturers will only need a few instruments for homologation and research Increasing focus on otto (petrol) engine PN Pre-DPF measurements will be of increasing importance (DPF loading, reg. strategy, dur ). More information is needed (size, mass, etc ) AVL & Horiba will claim 90% of PMP market New: PEMS applications will come! 2010-05-24 Legislation and trends 25

Portable Emission Measurement Systems PEMS Peter Ahlvik

Candidate portable instrument systems Adopted from JRC presentation AVL Micro Soot Sensor Control Sistem Micro-PSS Dekati ETaPS Dekati DMM Horiba OBS-TPRM Sensors PPMD (MPS+QCM) 2010-05-24 Legislation and trends 27

Phase 1 - preliminary results Adopted from JRC presentation 2010-05-24 Legislation and trends 28

PEMS approach by Control Sistem Starting from PSS-20 experience Control Sistem developed its portable version that can be used for on-road tests 2010-05-24 Legislation and trends 29

Standard PSS-20 vs Micro-PSS 1(2) 2010-05-24 Legislation and trends 30

Standard PSS-20 vs Micro PSS 2(2) Structure PSS-20 19 rack cabinet and minitunnel trolley Micro PSS Single box unit 25 x 20 x 14 Filter size 70 + 47 mm 47 mm Bypass line Filter, proportional valve, sampling valve Not present Pumps 240V AC, 10.000 nl/h 24V DC, 4.750 nl/h Flow meters Rotary piston G16 Rotary piston G16 Control unit Industrial PC on the main cabinet Laptop with TCP/IP I/O system Power supply 240V AC, 1.8 kw 24V DC, 20 A Weight 250 kg < 40 kg 2010-05-24 Legislation and trends 31

Micro-PSS main components Sample inlet Mixing zone Dilution air in Dilution tunnel Filter cartridge Filter holder Diluted gas out 2010-05-24 Legislation and trends 32

Micro-PSS main components Pumps Dil. air filter Gas flow meter Dil. Air heater Pumps drivers Air flow meter I/O system 2010-05-24 Legislation and trends 33

Exhaust flow [kg/h] Sample flow [g/h] Micro-PSS flow control Correlation coefficient = 0.985 ( >0.95) Standard error of estimate = 2.48% ( <5%) Intercept of regression = 0.33% ( < 2%) ETC cycle (simulated) Filter diameter 47 mm Filter face velocity 35 70 cm/s Filter temperature 47 ± 5 C 2000 600 1800 1600 500 1400 400 1200 1000 300 800 600 200 400 100 200 0 0 400 410 420 430 440 450 460 470 480 490 500 Time [sec] 2010-05-24 Legislation and trends 34

Sampling strategy The distance between the Micro-PSS and the tailpipe can vary depending on vehicle configuration Sampling probe on vehicle exhaust pipe < 2m particulate heated transfer line Auxiliary exhaust transfer pump Heated or insulated 5 m line. Sampling point near to the microtunnel SAMPLE TRANSFER LINE EXHAUST TRANSFER LINE VENT DILUTION AIR DILUTION AIR FILTER FILTER EXHAUST EXHAUST DILUTED GAS DILUTED GAS 2010-05-24 Legislation and trends 35

JRC installation for PEMS program 2010-05-24 Legislation and trends 36

Meeting at JRC, May 6 Control Sistem, Pegasor & ExIS All testing at JRC so far with PPS prototype; new tests in June with final production unit. Issues w. Micro-PSS to deal with: Sensitivity: high-sensitivity version Zero drift (?) JRC will make tests with final version Micro-PSS available for Round Robin PSS-20 with PPS-M to be exhibited at the Automotive Testing Expo Demo is possible at customer sites in Q3 2010-05-24 Legislation and trends 37

Pegasor signal (%) Pegasor integrated signal (%) Some JRC test results 3.0 2.5 Pegasor (%) Integrated (%) 120 100 2.0 80 1.5 60 1.0 40 0.5 20 0.0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 2010-05-24 Legislation and trends 38

Pegasor PPS-M will be the heart of many other measurement systems RS-PMP CVS-R03 Micro-PSS PSS-20 2010-05-24 Legislation and trends 39

PEMS (PM) summary & conclusions PEMS has focused on replicating lab meas. Laboratory testing in finished at JRC Next phase will be a Round Robin phase for onboard testing. Two candidate systems: Horiba: OBS Control Sistem: Micro-PSS PEMS will also be interesting for non-highway vehicles and (presumably) light-duty vehicles JRC contemplates about PEMS for PN Production version of Micro-PSS & PSS-20 2010-05-24 Legislation and trends 42

This concludes the presentation Thank you for your attention! More information available at: www.exisab.com 2010-05-24 Legislation and trends 43