Watermaster Exterior Socket (Part Number ES1001 or ES5001) Vehicle Wall Outside Caravan. Dust Cover. Water Container

Similar documents
Exterior Pump Range INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

To the Fitter: Ensure all relevant personnel read the points listed below and that a copy is passed on to the end user.

INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

BP3000 / BP3010 / BP3020

Gusher 30. Ease of use easy grip handle. Ease of operation extra long handle

Gusher Titan. Tough and Lightweight Polypropylene Models GUSHER TITAN combines powerful performance and lightweight design

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Gusher 10. Easy grasp handle. Durability long life LM6 diecast alloy. Easy maintenance designed for instant access

Diaphragm* Service Kits

DC Master 24/ A

Model &

Elmdene International Ltd

Technical Data 12HD.K 12V/24V DC DUAL VOLTAGE FUEL TRANSFER PUMP KIT. Please read carefully before commencing installation

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

Intelligent Water Systems for Intelligent Boats

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Whale - Electric Bilge Pump Range From the Experts in Bilge Pumps experience in electronics

Technical Data 12HD.K 12V/24V DC DUAL VOLTAGE FUEL TRANSFER PUMP KIT. Please read carefully before commencing installation

HALLMARK INDUSTRIES INC

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

SUBMERSIBLE DIRTY WATER PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Peristaltic Cased Tube Pumps

Battery Charger JCB-FCH20LI2

GL1200T Cut & Seal. (GL1200 Seal only)

Installation Operation Parts

AC Anywhere. User Manual. Power Inverter. (Class II product) Please read the installation and operations instructions before using the Power Inverters

MODEL H INSTALLATION INSTRUCTIONS

Installation, Operating, Maintenance and Safety Instructions JABSCO & Series 1 40 SIZE UTILITY Pump

EC400 Power Control System

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

airbox User Manual VARIFLOW/VARIFLOW 8 telephone: +44(0) web:

6L Oil-less Air Compressor 53103

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW)

Peristaltic Pump Operating Instructions

MICROFLOCKER. Operating Instructions

SELF PRIMING CHEMICAL SERVICE PUMPS

Embedded Rack Slide-out System

Battery Charger JCB- SCH20LI.2

EC200 ELECTRONIC CONTROL SYSTEM

OPERATION MANUAL, POWER MODULE-CHARGER SYSTEM. Man Occup. Machine Occup. Cycle Time Setup Time Batch Qty. Equipment Manufacturer Qty

JABSCO & Series 1½ 80 SIZE UTILITY Pump

Table of Contents 文管中心 發行章

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

10A / 15A / 20A Solar Charge Controller. PU1024 / PU1524 / PU2024 series INSTRUCTION MANUAL

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

Matala. VersiFlow Series. Instruction and Maintenance Manual

Melody 1 Platform Lift

Operating instructions

SUPER PUMP OUT SYSTEM

PETROL GENERATOR SPG2200, SPG3000, SPG6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Original Language Version VS4021 Issue: 1-08/06/12

DEEP SEA ELECTRONICS PLC

SUBMERSIBLE WATER PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

ADVANCED ELECTRONIC ACCELEROMETER TRAILER BRAKE CONTROL

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

c-go 24V/6A 24V/8A 24V/12A

Smart Battery Charger

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

ESE Series Cast Iron Sewage Pumps

User Manual. Solar Charge Controller 3KW

INSTALLATION INSTRUCTIONS SERVICE KIT - MONSOON EXTRA S1.4 bar SINGLE Part No MONSOON EXTRA U1.4 bar SINGLE Part No.

GeyserMax-Flow Series

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Model Number: CM-046. QUATTRO Handset Installation guide and user information. Ref: CM-046 UK-Rev.C.

OPERATION & MAINTENANCE INSTRUCTIONS

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Installation and Operating Instructions

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

LAWN SPRINKLER, IRRIGATION PUMP

Artesian2 Owners Manual

Rev: Flow Max 115V AC Fluid Pump

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

PETROL GENERATOR PGH2200, PGH3000, PGH6500 OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Electric Hi Lo Screen lift Trolley Mount 8960

Installation instructions

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

OPERATION & MAINTENANCE INSTRUCTIONS

POSITIVE DISPLACEMENT FLOWMETERS

TPAK Series COOLANT PUMP

Installation & Technical Guide. Domestic & Commercial.

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

Rental Industry Safety Tester Safe Check 5s

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing.

ATD WATT INVERTER

Sinergex. PureWatts Elite 150. User's Manual. Sinergex Technologies L.L.C. (USA) Website:

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

1901 Thermostatic Shower Mixer

Hybex Microsample Incubator

GARDEN HOSE UTILITY PUMP

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

PRESSURE BOOSTER 150

Transcription:

High Flow Watermaster Pump with Intelligent Control (IC) EP1632 INSTALLATION & USER INSTRUCTIONS Thank you for purchasing this Whale product. For over 60 years, Whale has led the way in the design and manufacture of freshwater and waste systems including: pumps, plumbing faucets, showers for low voltage applications. The company and its products have built a reputation for quality, reliability and innovation backed up by excellent customer service. Typical Installation The Watermaster IC is designed for use in recreational vehicles to simplify the supply of freshwater to caravans and motorhomes, where a Whale High Flow Watermaster pump is used to supply the taps and showers. Please note that caravan water systems and domestic water systems differ. Please exercise caution when using the hot water supply. It is possible to get unmixed hot water when the tap or shower is initially opened. The Watermaster socket (already installed or available separately) must be mounted so that the rear of the socket is accessible from within the vehicle.ensure at least 30mm clearance below the socket to allow for wiring. Watermaster Exterior Socket (Part Number ES1001 or ES5001) Watermaster Easi - Push Plug Vehicle Wall Outside Caravan Dust Cover Watermaster Exterior Socket (Part Number ES1001 or ES5001) Rear of Socket Inside Caravan Watermaster Easi - Push Plug Watermaster High Flow Pump Water Container Vehicle Wall Outside Caravan Fig 1: Pump Location Fig 2: Socket Location Following a simple calibration process the Watermaster IC:- removes the need for adjustment of the pressure switch removes the requirement to have a surge damper in the system switches off the pump when it runs dry. For information on our full product range visit: www.whalepumps.com This product is designed for use with freshwater. If it is intended for use with any other liquid, it is the user s responsibility to ensure that the materials are fully compatible with the liquids to be used and that a system of safe working practice is applied to installation, use and maintenance. 1

SPECIFICATION Product Codes Voltage Nominal Current Recommended Fuse Size Weight Materials Accessories Service Kits Performance Data @ 13.6V Discharge Head - 0 m (0ft) 1 m (3ft) 3 m (9ft) Compatible Pumps EP1632 Voltage range 9.5V d.c. to 14.5V d.c. (normal operation) Voltage range 8.5V d.c. to 9.5V d.c. (limited operation) Operating 3.7 Amps Standby 0.007 Amps 5 Amp automotive 0.65kg Pump Body: ABS, Seals: Nitrile, Strainer: Polypropylene Impeller: PBT, Cable: PVC, Grease Seal: Nitrile Wire: PVC insulated copper, Hose: PVC, Plug: PBT Watermaster IC: Polycarbonate WF1230 inline water filter (available separately) Watermaster IC is not a serviceable part EP1612 - Replacement High Flow plug and pump kit Flow Rate Per Minute / Current Draw - 15.8 ltrs / 3.8 amps 14.8 ltrs / 3.7 amps 12.8 ltrs / 3.5 amps For use with Whale High Flow Watermaster (EP1612) only Operating Temperature Range 3ºC to 40ºC Storage Temperature Range -30ºC to 60ºC Whale s policy is one of continuous improvement and we reserve the right to change specifications without prior notice. 1. PRINCIPLES OF OPERATION The Watermaster IC is a means of control for the Whale Watermaster High Flow pump, which allows it to operate without the need for pressure switch adjustment. It offers three key features:- eliminates rapid water pulsation, ensures that the pump turns off at low battery voltages and also in a run-dry situation when the water supply runs out. This Intelligent Control is achieved as the pressure switch turns the pump on when the pressure drops to a low level and the microprocessor turning off the pump at programmed current levels. These current levels are set during the simple calibration process. This calibration process may have to be repeated if the pump is replaced. To the Fitter: Check that the product is suitable for the intended application, follow these installation instructions and ensure all relevant personnel read the points listed below. Also ensure that these operating instructions are passed on to the end user. 2

To the User: Please read the following carefully before installation Removes the need for adjustment of the pressure switch, and removes the requirement to have a surge damper or inline pressure switch in the system. Watermaster IC is pre-programmed and must initially be calibrated before use - see Section 6. When the system has shut down due to running out of water, reset by turning the pump isolation switch off and back on after refilling the tank. If the battery voltage is very low (8.5V and 9.5V), the Watermaster IC is designed to shut down after approximately 30 seconds operation to prevent the battery being drained further. Restart the system by turning the pump isolation switch off and back on. This can be repeated to provide a limited operating mode but the battery should be recharged as soon as possible. Please remember that caravan water systems differ from domestic water systems and for this reason it is important to exercise extreme caution when using the hot water supply as it is easier to get unmixed hot water when the tap or shower is initially opened. 2. APPLICATION Please note that Watermaster IC is designed to work with the Whale Pressure Switched Socket (Part Number ES1001 or ES5001), and with the Whale High Flow Watermaster pump kit ONLY. It is not compatible with other sockets or pump systems For users with other Whale or non-whale products, their systems may be upgraded to IC by purchase of the Whale product codes - socket ES1001 or ES5001 and Pump & Watermaster IC Kit (EP1632). 3. WARNINGS This product is not designed for any other purpose than supplying water to a caravan or other recreational vehicle system. Please note that caravan water systems and domestic water systems differ. Please exercise caution when using the hot water supply. It is possible to get unmixed hot water when the tap or shower is initially opened. Always disconnect power sources before installing or making connections. Wiring must comply with applicable electrical standards and include a 5 Amp automotive fuse or circuit breaker. Improper wiring can cause a fire resulting in injury or death. Suggested wiring information is given as a guide only. Please note that incorrect installation may invalidate the warranty. The Watermaster IC is designed to work in conjunction with a 5 Amp automotive fuse (see fuse box for fuse marked pump ). The Watermaster socket (already installed or available separately) must be mounted so that the rear of the socket is accessible from within the vehicle.ensure at least 30mm clearance below the socket to allow for wiring. Please note that incorrect wiring will result in a blown fuse. Please note that Watermaster IC is designed to work in conjunction with the Whale Watermaster 12V d.c High Flow Pump with Easi - Press Plug (EP1612) and the Whale Watermaster Pressure Switched Socket (ES1001 or ES5001) ONLY and will not operate with any other Whale products. Please note that the Watermaster IC Pump Controller MUST be calibrated to the High Flow Pump that will be used with the van. If the pump is replaced, the Watermaster IC Pump Controller MUST be recalibrated to the new pump. 3

With all applications it is important that a system of safe working practice is applied to installation, use and maintenance. Please note that the Watermaster IC controller unit is enclosed to protect the electronics. Opening the unit will result in damage and will invalidate warranty. Do not use the pump in water temperatures above 40ºC (100ºF). It is best to stand the pump vertically in the tank. Contact Whale Support on 028 9127 0531 for additional advice on this product or its installation. 4. PARTS LIST Qty 1 Qty 1 Qty 1 Watermaster IC Control Unit Securing screw Watermaster 12V d.c. High Flow Pump with Easi - Press Plug 5. OPTIONAL EXTRAS Part Number (Available Seperately) GP1652 Description Whale Watermaster High Flow Pump EP1612 Whale Watermaster High Flow Pump with Easi - Press Plug EP1632 Whale Watermaster IC Kit - includes Watermaster IC Control Unit and Watermaster 12V d.c. High Flow Pump with Easi - Press Plug 6. INSTALLATION Please note - The manufacturer cannot be held responsible for claims arising from incorrect installation, unauthorised modification or misuse of this product. Before installing, please check that the submersible pump can reach the bottom of the water container (see Fig. 1) and that there is access to the back of the socket (see Fig. 2). Ensure that the system is fully drained before starting the installation. To do this open and close all outlets to expell water and air. CONNECTING THE IC CONTROL UNIT (to the back of socket) Step One - Switch off the 12V d.c. supply at the main panel (isolator switch). Step Two - Unplug the 3 electrical spade connections (Negative, Positive and Pump Running Light) at the bottom the water inlet socket. Please ensure that you note the order of wires for reconnection to the Watermaster IC Control Unit (see Fig. 1 & Fig. 2 below). Pressure switch adjusting screw & locking nut (Remove as per Step 3) Fig. 3 Wiring connections Watermaster socket 3 Fig. 4 Watermaster IC features

Step Three - Unscrew and remove the pressure switch adjusting screw and locking nut (see Fig 1 above). Step Four - Remove securing screw (see Fig. 5 below) Fig. 5 Removing Securing Screw Step Five - Take the Watermaster IC Control unit and place countersunk screw (Included) into screw hole on the Watermaster IC Control unit (see Fig. 4 below). Fig. 6 Place Securing Screw into Watermaster IC Control Unit Step Six - Plug Watermaster IC Control Unit onto socket (see Fig. 5 below) and tighten screw (N.B Do not over tighten) Fig. 7 Insert screw into Watermaster IC Step Seven - Reconnect the 3 electrical spade connectors, ensuring correct order of wires (as per Step One). 5

CONNECTING YOUR PLUG AND PUMP KIT Prior to using your water system for the first time, the system will need to be primed and the Watermaster IC unit will need to be calibrated by following the simple steps below. To Prime the Water System Step One - Place the pump into a full water container. Ensure the pump can reach the bottom (as shown in Fig. 1). Step Two - Insert Easi - Push Plug into socket and close lid to lock into place (see Fig. 8a & 8b below). Fig. 8a & 8b Insert Easi - Push Plug and Lock in Place Step Three - Adjust dust cover over opening in container (please note dust cover should not be secured to water. container as air must be allowed to enter container to replace water being pumped out). Step Four - Switch on 12 volt supply at main panel (Isolator switch) - the pump should start to run. Step Five - Open the cold shower mixer (or the outlet furthest from the Watermaster IC Control Unit in the van). Step Six - After trapped air has been expelled, by following Step Five, water will flow from the open outlet. Step Seven - When air has been expelled turn off shower, the pump should turn off after approximately 10 seconds. To Calibrate Your Watermaster IC Control Unit To ensure successful installation and optimum performance of the Watermaster IC Control unit, you must follow the 5 simple steps below:- Step One - Press and hold the calibration button until the green LED starts to flash after 1-3 seconds (see Fig. 9). Green calibration LED Fig. 9. Calibrating the system Step Two - Open the cold shower and the pump should start (there may be a short delay). Step Three - After approximately 30 seconds, turn off the shower. Step Four - After approximately 10 seconds, (the pump should still be running), press and hold the calibration button again until the LED turns solid green and the pump will stop after approximately 10 seconds. Step Five - The green LED should turn off and blink briefly every 5 seconds. The system is now calibrated. 6

The Watermaster IC is now installed and ready for use. During normal use you will only need to recalibrate if you use a different pump. Simply repeat the steps above to calibrate a new pump. Please Note: When the tap is first opened a small drop in water pressure is normal until the pump starts running. Please Note: In normal operation the pump may run for up to15 seconds after the tap is closed. Handy Hint: Pump hose can be inserted into groove on plug to keep pump off ground while refilling water container. (Fig. 10). The plug must always be removed before moving the caravan/motorhome. Fig. 10. Handy Hose Holder Removing the Pump: Step One - Lift the lid to unlock the plug (See Fig. 11). Step Two - Pull out plug from socket using hand grip (See Fig. 11). Step Three - Shut lid. 7. INSTRUCTIONS FOR PUMP STORAGE WHEN NOT IN USE The plug must always be removed from the external water socket before moving the caravan/motorhome and stowed in a clean, dry place. 8. MAINTENANCE Fig 11. Removing Pump This IC control unit (located on the back of the socket) is designed to be service free and does not contain serviceable parts. Please note that the unit is enclosed to protect the electronics. Opening the unit will result in damage, and will invalidate warranty. For information on service kits, please visit www.whalepumps.com 7

9. HELPFUL HINTS If at any stage the user experiences less than optimum performance from the Whale Watermaster IC, recalibrate the system as per steps above in Section 6. To obtain efficient running and maximum pump life, ensure the following: There is sufficient water in the container. Maximum pumping period is not more than 15 minutes. All hose connections are firm and water tight. The power supply is adequate - low performance could result from a weak battery or reduced voltage due to undersized wiring (we recommend wiring should be a minimum thickness of 2.5mm²). When replenishing the water supply, it is possible to create an air lock in the pump. As a result, the pump will run noisily and give no discharge. To remedy, unplug from the socket while keeping the pump submerged to dislodge the air pocket in the pump. Also shaking the dual hose gently may dislodge the air pocket in the pump, or switch off pump at main panel, open a tap outlet and switch pump on again at the main panel. 10. TROUBLE SHOOTING PROBLEM POSSIBLE SOLUTIONS Check at least one tap is open Check the battery condition Check the mains isolator switch is on Pump will not run Check the pump isolator switch is on Check the contacts in the plug and socket are clean and making contact Check wiring connections Check fuse (see fuse box) Turn the pump isolation switch off and on again Check for air or water leaks in taps and piping The pump cycles on/off with all taps and shower closed Check that the non return valve in socket is free from grit by pushing a suitable blunt object, for example a ballpoint pen into the socket nipple against the non-return valve holding the valve open to dislodge trapped grit Check within 1 year warranty. Contact retailer and replace pump Runs continuously and does not stop after 30 seconds Check all connections in pipework 8

Diagnostic Codes To aid with troubleshooting the LED on the back of the Watermaster IC has a number of different flash codes as described in the table below LED State Description Green Constant On Tap open, pump running Green Fast Flash (< 1 sec) In Calibration Mode Green 200ms blink every 5 sec Calibrated and ready for use Green 200ms blink every 10 sec Un-calibrated Green 200ms blink every 15 sec Suspended due to dry run need to turn pump switch on and off Green 200ms blink every 20 sec Suspended due to low battery voltage, turn pump switch on/off, need to charge battery 11. WINTERISING Watermaster IC does not require any additional winterising. For details of how to drain your water system for winterising please visit www.whalepumps.com/rv 12. SERVICE SUPPORT DETAILS For installation or serviceable parts advice please contact Whale Customer Support: Tel: +44 (0)28 9127 0531 Email: info@whalepumps.com www.whalepumps.com 13. EU DECLARATION OF CONFORMITY, STANDARDS & APPROVALS Declaration no.: EU-753.133-000 We the undersigned: Name of manufacturer: Munster Simms Engineering Ltd Address: 2 Enterprise Road, Bangor, BT19 7TA Country: Northern Ireland Declare under our sole responsibility that the following apparatus: Product description: Pump controller Model name and no.: Watermaster IC EP1632 Brand name: Whale Is in conformity with the following relevant EU Legislation: EMC directive 2004/108/EC LVD directive 2006/95/EC Based on the following harmonized standards: EN55014-1:2000 EMC Emissions EN55014-2:1997 EMC Immunity And therefore complies with the essential requirements of those directives. Additional information: Technical file number: TF-753.133-000 9

Location of technical file: Munster Simms Engineering Ltd, 2 Enterprise Road, Belfast, BT19 7TA Year mark first applied: 2012 Limitations of use: For use with EP1612 12V submersible pump only Name and position of person binding the manufacturer or authorized representative: Signature: Name: Richard Bovill Function: Engineering Director Location: Munster Simms Engineering Ltd 2 Enterprise Road, Belfast, BT19 7TA Date of Issue: 27.03.12 14. PATENTS AND TRADEMARKS CE marked Watermaster IC is protected by the following pending Patent Application. Patent UK patent application no. 1017025.6 Whale, Whale Watermaster, Watermaster and Intelligent Control are registered trademarks of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale. 15. WARRANTY This product is protected by a 1 year warranty, for full details of our warranty statement please see enclosed leaflet. Copyright Whale 2016 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE is a registered trademark of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale. Whale s policy is one of continuous improvement and we reserve the right to change specifications without prior notice. Illustrations are for guidance purposes only. Please note that by contacting Whale Support you will be indicating your consent to receiving product updates, recall information, help guides and appropriate marketing messages from us via post, email or telephone unless you indicated an objection to receiving such messages. Munster Simms Engineering Ltd. 2 Enterprise Road, Bangor, N. Ireland BT19 7TA Tel: +44 (0)28 9127 0531 Email: info@whalepumps.com Web: www.whalepumps.com 10

Ref: 180.156_v4_0616_ah_db