Before replacing LED light ensure the unit is switched off, when you want to

Similar documents
RA-7730SS RA-7736SS RA-7742SS RA-7748SS. For residential and indoor use only.

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

MoJack Pro Assembly Instructions

PATRIOT INSTRUCTION MANUAL FMGRID-16, FMGRID-24, FMGRID-30 ELECTRIC GRIDDLES

INSTALLATION INSTRUCTIONS TOP MOUNT SINKS

INSTALLATION INSTRUCTIONS

CAUTION: Do not install damaged parts!!!

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

CAUTION: Do not install damaged parts!!!

Installation Instructions Model: AB Single-Lever Pull-out Kitchen Faucet

WARRANTY POLICY FOR LD SERIES LABEL DISPENSERS REPAIR POLICY

INSTALLATION INSTRUCTIONS UNDERMOUNT SINKS

Harley Davidson FL Touring Current Xtreme

INSTALLATION & OWNER'S MANUAL

Installation Instructions Model: AB Single-lever Pull-down Spray Faucet

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

Operation Manual RANGE HOOD

PROFESSIONAL WALL HOODS PH30ZS, PH36ZS, PH42ZS, PH48ZS, PH54ZS

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER C (GUN METAL GRAY FINISH) 2016 VW Jetta 1.

EXT DUCTLESS FUME HOOD

CAUTION: Do not install damaged parts!!!

INSTALLATION INSTRUCTIONS TOP MOUNT SINK CH366

Stainless Steel Kick Bucket and Stand

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

SUPERPLUS WATER FILTRATION SYSTEM

INSTALLATION INSTRUCTIONS

Installation Operation Maintenance Troubleshooting Version 1, Oct/09. Palm Beach

HARDWARE KIT INSTALLATION GLOVES

ASSEMBLY AND INSTALLATION INSTRUCTIONS

OPERATION AND ASSEMBLY MANUAL HIGH JACK STANDS Models: RJS-1T RJS-1TF RJS-2TH

INSTALLATION INSTRUCTIONS

Air Knight REME by RGF

Effective June 1, 2013 This guide supersedes all previous versions

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

GW-120 Bar Glass Washer

INSTALLATION INSTRUCTIONS. PART NUMBER C (Gun Metal Gray Finish) 2016 HYUNDAI TUCSON 1.6 Turbo

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

Standard Gauge Switch

36 & 48 ISLAND AND WALL CANOPY RANGE HOODS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Remove 4 circled pins. Route wiring along dashed line. Remove the 2 9mm nuts and black retaining plate that secure extractor.

WARNING!!! READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE PROCEEDING. MAKE SURE THAT YOU HAVE ALL TOOLS AND PARTS BEFORE BEGINNING THE INSTALLATION.

1416 Cabinet Unit. Installation Operation Maintenance Troubleshooting Version Dec/17

INSTALLATION INSTRUCTIONS

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

CAUTION: Do not install damaged parts!!!

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

2015 & 2018 Fender Brace Installation Instructions

INSTALLATION INSTRUCTIONS PART NUMBER:

ADI-125/750 ADI-125/1500 ADI-125/2500

HSB21 Battery Burnisher

INSTALLATION INSTRUCTIONS PART NUMBER: AUDI A4 L4-2.0L C.A.R.B. E.O. # D-670-2

RYDIS UV-C Vacuum Cleaner U60 / U60 Pro MANUAL

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PART NUMBER C (Gun Metal Grey Finish)

INSTALLATION INSTRUCTIONS PART NUMBER C (Gun Metal Gray Finish)

MODEL HLY-2001 rev. B TANK MOUNT SPEEDOMETER/TACHOMETER INFORMATION SYSTEM

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

PACIFICA Shower Cabin Installation Instructions

INSTALLATION INSTRUCTIONS PART NUMBER C (Gun Metal Gray Finish)

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

Swing Arm Magnifying Lamp

In Sump Cone Protein Skimmer 400

LIBERATOR USER MANUAL

MP/MTFL LIGHT FIXTURE (Dimming)

Measurements and Diagrams Installation Overview: A B C A Qty: 6 PCS (For sheet rock only) B Qty: 6 PCS Mounting Bracket Re-circulating kit exhaust (Re

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

Cookshack Pellet Fired Charbroiler Models: CB012 CB024 CB036 CB048

22427 SWAY BAR SET 2002-UP SUBARU WRX WAGON

PASS THROUGH WINDOWS

ME AGS Auto Gen Start System for Coach Generators. Operator s Manual.

Installation and Operation Manual

Installation & Operation Manual Chef Base

INSTALLATION INSTRUCTIONS

User Manual HomeGrid 5000 HD

Air Lift. Kit PERFORMANCE INSTALLATION GUIDE Scion xb

IN SUMP PROTEIN SKIMMER TOP QUALITY & HIGHLY EFFICIENT INCLUDES NEEDLE WHEEL PUMP 1 YEAR WARRANTY

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER: DS (Plastic tube)

INSTALLATION INSTRUCTIONS PART NUMBER

Installation Instructions / Warranty

WARNING!!! READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE PROCEEDING. MAKE SURE THAT YOU HAVE ALL TOOLS AND PARTS BEFORE BEGINNING THE INSTALLATION.

Geopump Peristaltic Pump Installation and Operation Manual

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

CAUTION: Do not install damaged parts!!!

advanced FLOW engineering Instruction Manual P/N: / Make: BMW Model: Z3 (E36/37) Year: Engine: L6-2.8L

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER:

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

EXT HEPA/CARBON FUME HOOD

3V SERIES SOLENOID VALVE

/08. Holiday Central G Gauge Owner's Manual. Adult Assembly Required

OWNERS MANUAL JANUARY 2007 ISO

400E Steam Locomotive

Bus Station. PLEASE READ BEFORE USE AND SAVE

INSTALLATION INSTRUCTIONS PART NUMBER: C (Gun Metal Gray Finish)

Stealth Power i-tilt

/04. Lionel Mainline Auto Crossing Gates Owner s Manual

OCTA FLUORESCENT 7 SOCKET FIXTURE

Transcription:

I. Replace the LED Light Before replacing LED light ensure the unit is switched off, when you want to change the LED light, please always wear working gloves.. Using suitable tool (small slotted screw driver) gently pry off the LED light set.. Taking off the wire connecter with LED light set. 3. Replace a new LED light set and reconnect the wire to the connector.. Before push back the original LED light position, test the LED light. LED driver: Model: HP500-36 input: 00~0vdc output: 3.6vdc=500maH LED light: W Model: HP-5A NOTE : For LED light replacement, you may not find the appropriate LED lights from market, please contact with distributor(s)/dealer(s). 3

J. Maintenance Instruction. Maintenance should be important than repair. Please take care of the needed maintenance in order to secure and extend the excellent functions and using life. Note: Before repairing the range hood. Disconnect the power source.. After using the machine, wipes the machine by neutral detergent in order to keep it clean and maintain the appearance with brightness and sanitation. 3. When the level of dirty oil of the collector reached /5 of height, it has to be removed in order to avoid overflowing and pollution. K. Troubleshootings Symptom Fan are not operatable. Correction A. Check power source to see if it is normal. B. Check power inlet plug to see if it is plugged firmly into it's socket. Illuminating LED light does not word A. Disconnect the power source. B. Check LED light, replace it with a new one if it is burned out. Hood vibrates. A. Check for damaged vanes. B. Check if exhaust duct is secured.

L. Use and Care Note: Operate switches (Fig.) Switch : LED Fan speed indicator. - Low speed - High speed Switch : Speed switch (Three speed fan) 3 Switch 3 : Light switch Switch : Power switch and delay switch. Fig. Push once : Delayed shut off. Push twice : Immediate shut off. Note: Range hood should be turn on either before or the same time when cooking begins. After cooking, range hood should be kept on for about 3 more minutes for complete ventilation of cooking odor. Care Instruction: Please always pull the plug out before cleaning or dismantling, wear 'Safety gloves' to reduce the risk of any injuries. Exterior: Can be clean with any type of non-abrasive detergent and a clean cloth. "Green Pad" or any metal type cleaning pad is not recommended for exterior. 5

M. Parts layout diagrams MODEL : RA-3330C RA-3336C 3 5 6 7 8 9 0 RA-3330C RA-3336C -. Duct cover-mounting bracket 7. Control board. Duct cover (Optional) 8. Processor board 3. Hood-Mounting bracket 9. LED driver. Rubber stand 0. Capacitor 5. Hood casing. Squirrel cage 6. LED light. Aluminum filter (-) 6

MODEL : RA-330B RA-336B 3 5 RA-3B RA-38B 6 7 8 9 0 RA-330B RA-336B 3-3- RA-3B RA-38B - 3- -3 3-3. Duct cover-mounting bracket 8. Processor board. Duct cover (Optional) 9. LED driver 3. Hood-Mounting bracket 0. Capacitor. Rubber stand. Squirrel cage 5. Hood casing. Stainless steel spacer 6. LED light 3. Baffle filter 7. Control board 7

MODEL : RA-3530B RA-3536B RA-35B RA-358B 3 5 7 6 8 0 9 RA-3530B RA-3536B - - RA-35B RA-358B - - -3-3. Duct cover (Optional) 7. Capacitor support. Duct cover-mounting bracket 8. LED driver 3. Hood casing 9. Capacitor. LED light 0. Squirrel cage 5. Control board. Stainless steel spacer 6. Processor board. Baffle filter 8

N. Circuit Diagrams Fig.3 Details the internal electrical circuit of this range hood unit. Any faults with this unit should only be attended to by a qualified technician. White Yellow Orange Red Brown Black White Blue Gray Red White Capacitor Brown Yellow Brown Yellow Motor Blue Gray Red Motor Brown Black LED driver Black Red LED light Black White Power Ground Fig.3 Electrical Schematic Diagram 9

WALL HOOD OPERATION MANUAL RA-33 Series RA-3 Series RA-35 Series Please read and save this guide through before using your range hood Storetheguideawayinasafeplacesothatyouwillknowwhereitis when you want to refer to it O. Accessories Spare Parts Contents Spare Parts Contents Item Part Description Spec. Q'ty Item Part Description Spec. Q'ty Manual Screws Øx3 3 Round Collar Toggle Bolts 6"/7" #3/6"x3" Screws package Screws Plastic Screws Ø3/6" x3" /" P. Specifications Specifications Revolutions Consumption - Motor Consumption - Lamp Rotation Diameter Exhausting Duct Voltage Appearance Treatment RA-3330C / RA-3336C RA-330B / RA-336B / RA-3B Low - 590 50 R.P.M. High - 650 50 R.P.M. 80W Wx/3.6Vdc/500maH Squirrel Cage 6 " / 7" Round Outlets adapter 0V/60Hz Brushed Stainless Steel RA-38B x3 Specifications Revolutions Consumption - Motor Consumption - Lamp Rotation Diameter Exhausting Duct Voltage Appearance Treatment Low - 690 RA-3530 / RA-3536 / RA-35 50 R.P.M. High - 660 50 R.P.M. 80W * Specifications subject to change without prior notice. Wx/3.6Vdc/500maH Squirrel Cage 6 "/ 7" Round Outlets adapter 0V/60Hz Brushed Stainless Steel RA-358 x3 0

Q. Diagrams 0.6. 5 5 6 /3 6 Min: 9.7 Max: 35. 9-3/ (RA-3330) 35-3/ (RA-3336) 9-3/ (30 ) 35-3/ (36 ) Model:RA-3330:W9-3/" xd" xh6" RA-3336:W35-3/" xd" xh6"

9 0.6. /3 9 Min: 9.7 Max: 35. 9-3/" (RA-330) 35-3/" (RA-336) -3/" (RA-3) 7-3/" (RA-38) RA-330B RA-336B RA-3B RA-38B Model : RA-330:W9-3/" xd" xh9" RA-336:W35-3/" xd" xh9" RA-3:W-3/" xd" xh9" RA-38:W7-3/" xd" xh9"

3.5 9-3/" (RA-3530) 35-3/" (RA-3536) -3/" (RA-35) 7-3/" (RA-358) RA-3530B RA-3536B RA-35B RA-358B Model : RA-3530B : W 9-3/" x D " x H 8" RA-3536B :W35-3/" xd" xh8" RA-35B :W-3/" xd" xh8" RA-358B :W7-3/" xd" xh8" 3

Limited Warranty Windster Hoods Inc. warrants this product against defects in material or workmanship as follows: ) Labor: For a period of one () year from the date of purchase, if this product is determined to be defective, Windster will repair or replace the product, at its option, at no charge. After the warranty period, you must pay for all labor charges. During the labor warranty period there will be no charge for labor. ) Parts: In addition, Windster will supply, at no charge, new or rebuilt replacements in exchange for defective parts for a period of two () years. After the warranty period, you must pay for all parts costs. During the parts warranty period, there will be no charge for parts You must carry-in or mail-in your product during the warranty period. This warranty only applies to products purchased and serviced in the United States or Canada. What Is Not Covered By These Warranties: ) Conditions and damages resulting from any of the following: Improper installation, delivery, or maintenance. Any repair, modification, alteration or adjustment not authorized by the manufacturer or an authorized service dealers. Misuse, abuse, accidents, or unreasonable use. Incorrect electric current, voltage or supply. Improper setting of any control. Improper chemical cleaning. ) Light Bulbs 3) Products purchased for commercial or industrial use (such as in a hotel, office, restaurant, or other business) ) Damage due to earthquake, flood, storm, etc.

Defective Products: All products will be inspected, tested, and carefully packed by the manufacturer before shipping to customers. Products that are damaged during transit can only be exchanged for the same product, under the condition that the customer must get a RMA (Return Merchandise Authorization) from Windster. When products are received defective, you must notify us within the 3 business days of receiving the package. Replacement products are only shipped when the RMA is issued. NO EXCEPTIONS. Return Policy Windster offers only the best and highest quality products. If you are not satisfied with your purchase, please contact us within 3 business days of product arrival to obtain a Return Merchandise Authorization (RMA). Returns sent without a RMA will not be accepted. There will be a 5% re-stocking fee for every returned items. Shipping fee will also be deducted from the original purchase price. When returning a package, please include a copy of your purchase receipt. Use the original shipping box and packing materials and completely remove or cover the original shipping label. Make sure that products are in brand new condition, uninstalled, un-drilled, and contain everything that came with the package as when you first received it. If any parts or manuals are missing, we have the right not to accept the return. We suggest that you use a traceable and reputable carrier of your choice to ship your return. Your credit or refund will be processed within 0- business days from the date we receive your return.