Technical data. Standards: IEC/EN thermoplastic tightening force on nut 22 mm A/F max. 300 Ncm Protection class: IP 67 to EN 60529

Similar documents
Technical data. Standards: IEC/EN chromated and painted Protection class: IP 67 to EN 60529

Technical data. Standards: IEC/EN BG-GS-ET-15

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556S form A contact (normally open) for PCBs

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Microswitches M series

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H. form A contact (normally open) for PCBs

Miniaturized limit switches

AZM 161SK 12/12RKED/TU 024

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Safety door-handle system STS

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Prewired position switches FF series

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Comepi Limit Switches

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Ordering Information. Text PCB Power Relay G5LE

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Prewired position switches FF series

Safety rope switch without reset for simple stop

Position switches FR series

Micro Contactor MA Series

Plug-in relays Mini ISO relays

3RG4 BERO Inductive Proximity Switches

Climax Pneumatics Cnomo NFE Cylinders

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

SOLENOID VALVES AND PNEUMATIC VALVES

Climax Pneumatics. Cnomo NFE Cylinders Easley, South Carolina

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Single foot switches PX and PA series

SOLENOID VALVES PIV.M 15 mm

Floor and fine adjustment switches

Hinged Safety Door Switch

Thermal Overcurrent Circuit Breaker 3120-F...

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Industrial Contactors CTX 3 3P 185A - 800A

Single foot switches PX and PA series

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

Magnetic and Hydraulic-Magnetic Circuit Breaker

Microswitches MK series

Thermal Overcurrent Circuit Breaker 3120-F...

Climax Pneumatics. ISO 6432 Interchangeable Cylinders Easley, South Carolina

Safety rope switches with reset for emergency stop

AC/DC2-wire Type Cylindrical Proximity Switches

Safety Switches with Separate Actuator SKC

Solenoid interlock AZM 200 The non-contact interlock.

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Magnetic and Hydraulic-Magnetic Circuit Breaker

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

AF series contactors (9 2650)

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

AZM300 More than just a solenoid interlock

Command and signalling E 250, E 259 selection table

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Cable Plug acc. to DIN EN , Form A

AG Series Angular Grippers

Thermal Overcurrent Circuit Breaker 3120-F...

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Hour Meter Series HM36

55 Series - Miniature General Purpose Relays 5-10 A

WLA General Purpose LED Light - PWM Dimmable

Inductive Proximity Sensor

Automotive Relays PCB Single Relays. Micro Relay K (THT THR)

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Magnetic and Hydraulic-Magnetic Circuit Breaker

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

AF40... AF96 3-pole contactors Technical data

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

VALVES SERIES 70, SOLENOID/PNEUMATIC

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

Specification. Model MCRPL MCRPLF. Acting type Double acting Double acting. Tube I.D.(mm) , ,40,50 63

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Position switches FD series

SFS-UFS Single Foot Switches

Safety switches for hinged doors

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

ISO Cylinders Compact Cylinders TC08 Series Plastic Finger Tight Fittings

Switches with manual reset

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Small Limit Switch D4V

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Limit Switch - Prewired Type Metal Body

Proportional pressure relief valve, directly operated, rising characteristic curve

Metal tube variable area flowmeter for gases, liquids and steam

Transcription:

B /V Ø 20 0 5 60 Pg 00 22 3 Actuation from front Thermoplastic enclosure Central mounting Long life on-contacting principle Pre-wired cable available, cable length 1 m Protection class IP 6 When the switches and actuators come together, the colours must coincide: Red () to red () and green () to green (). This does not apply to the bistable contact. Ø 13 Technical data tandards: IEC/E 60-5-1 Design: cylindrical Enclosure: glass-fibre reinforced thermoplastic tightening force on nut 22 mm A/F max. 0 cm Protection class: IP 6 to E 6052 Termination: cable H03VV-F 2 x 0.5 mm 2, A03VV-F 3 x 0.5 mm 2, length 1 m Mode of operation: magnetic witching voltage: max. 0 VAC B -rz/v: max. 2 VAC/DC witching current: max. 3 A B -rz/v: max. 1 A witching capacity: max. 0 VA/W B -rz/v: max. 60 W Dielectric strength: > 600 VAC (50 Hz) B -rz/v: > 350 VAC (50 Hz) witching speed: max. 1 m/s witching frequency: max. 0/s B -rz/v: max. 200/s witching time Close : 0.3 ms - 1.5 ms witching time Open : max. 0.5 ms Bounce duration: 0.3... 0.6 ms max. 3 ms Ambient temperature: C + 5 ºC Mechanical life: 1 billion operations Electrical life: 1 million - 1 billion operations, depending on load Resistance to shock: g on sine wave B -rz/v: g on sine wave Resistance to vibration: g on sine wave B -rz/v: g on sine wave Resistance to vibration: 55 Hz, amplitude 1 mm witching point accuracy: ± 0. mm, T = constant Contact variants 1 O contact B -z/v with actuating magnet 1 C contact B -01z/V with actuating magnet 1 bistable contact B -rz/v with - actuating magnet Approvals C B -➀z/➁V o. Replace Description ➀ 01 1 C contact 1 O contact r 1 bistable contact ➁ With bias magnet /1 Without bias magnet ote A 3,0 2,0 1,5 1,0 0 0 0 0 2200 V witching capacity ote The opening and closing functions depend on the direction of actuation, the actuating magnets and the polarity of the actuating magnets. The actuating magnets are not included in delivery. To choose the appropriate actuating magnets, please use the tables on page 2-0. 2-1

election table: Magnetic reed switches Actuating distances Actuating magnets B 0-z B 0-01z B 0-rz B 5-r B 3-z B 3-01z B 3-rz B 32- B 32-01 B 32-11 B 32-r B 32-11r B 3-r B -z B -z/1 B -01z B -rz B -z/v B -01z/V B -11z/V B -11z/1V B -rz/v B -11rz/V B 20-z B 20-20z B 20-01z B 20-02z B 20-11z B 20-rz B 20-2rz B 20-11rz Page 2- Page 2-2 Page 2-2 Page 2-2 Page 2-3 Page 2-6 Page 2-6 Page 2- Page 2- Page 2- Page 2-0 Page 2-0 Page 2-1 Page 2-1 Page 2-2 Page 2-2 BP 6-1 2- BP 6-22 BP 3-0-5 BP 2- BP 6-2- 2-5 5 5 BP 5 BP - 5-20 5 5 2 x BP -20 2-13 2-13 1 1 3 2 x BP 20 20 2 x BP -36 6-20 20 BP -1 2-6 6 6 BP 1 1 BP - 5-22 1 1 6 2 x BP -22 2-1 1 2 x BP 13-3 -2 2 x BP /2 1 1 2 x BP /2 22 1 1 22 2 x BP /2 22 1 1 22 BP 3 5-20 -20 BP 3 - - - - - BP 3 20-50 -0 - - - - 20-2 x BP 3-26 5-1 2 x BP 3 22-60 BP 20-0-1 20 20 BP 20 3-5-20 5-20 BP 20-3 3-2 3-5-20 5-20 BP 31-0-1 20 20 BP 31 3-5-20 5-20 BP 31-0 - 3-5-20 5-20 BP 11 22-2 2-16 -20 5-20 BP 11 5 BP 11 - -23 5 5 2 x BP 11 3-20 20 2 x BP 11 3-20 20 BP -32-20 - - - 20 BP 20 20 BP -3 5-20 20 2 x BP - - - - 5-2 2 x BP - - - - 5-20 BP 21-50 20-0 -50 5 BP 21-5 -0-0 -5 20-5 -35 BP 21-5 -0-0 -5-35 2 x BP 21 20-60 20-55 20-55 20-60 -50 2 x BP 21 20-60 20-55 20-55 20-60 20-55 -50 BP 22 BP 22 +BP 22 35 2 x BP 22-55 BE 20 20 20 BE 20 20 20 BE 20 20 20 6 2-0 2-1

ystem components ystem components ystem components 1, ø3,3 ø 5 BP 6 ø ø1 BP, ø 3,3 ø 11, 1 BP 51 ø1,5 ø,3 ø 0 ø 2 51 () 0 BP BP 20 / BP 20 () ø20 5 23,5 3 BP /2 BP 31 ø3 5,3 5 23,5 3 BP 3 BP 31 / BP 31 0 BP BP 20 BP 11 Unenclosed, - BP 6 Unenclosed, - BP Unenclosed, - BP Unenclosed, - BP thermoplastic enclosure, - BP Unenclosed, - BP /2 thermoplastic enclosure, - BP 3 metal enclosure, - BP 20 metal enclosure Al, BP 20 metal enclosure Al, BP 20 thermoplastic enclosure, - BP 31 thermoplastic enclosure, BP 31 thermoplastic enclosure, BP 31 metal enclosure Al, - BP 11 2-

ca. 00 Magnetic reed switches ystem components ystem components ystem components 0 3 0 0 0 3 20 BP 11 / BP 11 2x BP 11 / 2x BP 11 BP 1 0 50 6,5 1 1 0 2x BP / 2x BP,5 13 BP 21 35 BP 21 / BP 21 35 0 2x BP 22 / 2x BP 22 55 3 2,5 1 62 0 5 66 160 15 10 BP 22,5 35 BP 22 / BP 22 ø 6,5 BP / BP 2x BP 21 / 2x BP 21 BE 20 16,5 metal enclosure Al, BP 11 metal enclosure Al, BP 11 metal enclosure Al, 2x 2x BP 11 metal enclosure Al, 2x 2x BP 11 metal enclosure Al, - BP metal enclosure Al, BP metal enclosure Al, BP metal enclosure Al, 2x 2x BP metal enclosure Al, 2x 2x BP metal enclosure Al, - BP 21 metal enclosure Al, BP 21 metal enclosure Al, BP 21 metal enclosure Al, 2x 2x BP 21 metal enclosure Al, 2x 2x BP 21 metal enclosure Zn, - BP 22 metal enclosure Zn, BP 22 metal enclosure Zn, BP 22 metal enclosure Zn, 2x 2x BP 22 metal enclosure Zn, 2x 2x BP 22 Electromagnet, thermoplastic enclosure BE 20 2-5

pacer B 31/33 Terminal mounting H,5 ø5 13 3,5 1,5 ø M5 1 33 6 To mount the magnetic safety sensor and actuator on ferromagnetic material For B Material: thermoplastic Holder H1/1 Compensating coil K 1 ø 13 3 1,5 ca. 0 1,5 3 5,5 2,5 3 3,5 M16 x 1,5 For B Metal holder with 2 elastic bearings Provides high resistance to vibration Temperature range C + 0 ºC For cable lengths up to 0 m Cable H05V-K 1 mm 2, cable length 0 mm The bucking coil is to be wired in series with the reed contact Version for high temperature C + 0 ºC, ordering suffix -T Holder H2 Compensating coil K 2 ø 13 2 16 ca. 0 3 5 22 2,5 11 M16 x 1,5 5 For B Metal holder with rubber washer Temperature range C + 0 ºC For cable lengths up to 200 m or 2 x 0 m Cable H05V-K 1 mm 2, cable length 0 mm The bucking coil is to be wired in series with the reed contact 2-6