B-1125 DANKO STOCK. DANKO XL SKID UNIT UPF Defender Poly Tank

Similar documents
DANKO STOCK B DANKO XL SKID UNIT 250 Gallon UPF Defender Poly Tank

DP A. 75 Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Phone : Fax :

DP Hector St., P.O. Box 90, Pierreville (Québec) Canada J0G 1J0 Phone : Fax :

OPTIONS SLIP-ON FIREFIGHTING UNITS

Darley UHP-HV Diesel Specification 1

Portable Pumps Transportable MaxStream Diesel Floating Pumps Pro Kit Skid and Trailer

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

BRUSH TRUCK. CET Quick Attack Unit. Ford Cab & Chassis Unit is to be installed on a Ford F350, 2 Doors Regular Cab, 4 x 4.

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

B Pump Mounting. Page 1 of 7

BRUSH TRUCK. CET Quick Attack Unit. Ford Cab & Chassis Unit is to be installed on a Ford F450, Ext. Cab, 4 x 4.

COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF CONSERVATION & NATURAL RESOURCES BUREAU OF FORESTRY DIVISION OF FOREST FIRE PROTECTION

HIGH VELOCITY PUMP PUMP END

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

DANKO STOCK Q-0410 DANKO FLATBED 60" CAB TO AXLE DUAL REAR WHEELS

SPECIFICATIONS FOR DIESEL DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

BRUSH TRUCK. CET Quick Attack Unit. Ford Cab & Chassis Unit is to be installed on a Ford F550, XL Regular Cab, 4 x 4

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

DANKO STOCK T DANKO PUMPER/TANKER 3,000 Gallon Dryside Poly Tank

DANKO STOCK T DANKO PUMPER/TANKER 1,600 Gallon UPF Poly Tank

STRIKERTM SERIES STRIKER-3 HIGH PRESSURE 3-STAGE FIRE PUMP. Features and Benefits. Applications DATA SHEET

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs

Centrifugal End Suction Fire Pumps

DANKO STOCK T DANKO PTO DRY SIDE TANKER 3,000 Gallon UPF Poly Tank

FOR YOUR SKID SPRAYER?

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-D

DARLEY PUMPS CAF SYSTEMS DAVEY PORTABLES DIESEL PORTABLE FAST ATTACK SKIDS

Fire Protection. FP-XA End Suction

Lightweight Aluminum Alloy Adapters

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

SPECIFICATIONS FOR GASOLINE ENGINE DRIVEN DUAL COMBINATION 1. LANCE: ULTRA HIGH PRESSURE PIERCING 2. BLITZ: ULTRA HIGH PRESSURE FOG

ADAPTERS & VALVES CAPS GASKETS STORZ ADAPTERS THREADED ADAPTERS. /adapters 2 1 /2" 3" 4" 4 1 /2" 5" 6" AC728: Male

PB18-G Series Portable Pump Service Parts List

Albemarle County Virginia Brush Fire Truck Specification

Oil & Light Fluid Pumps

Goulds Small Capacity Double Suction Pump

Draft Commander 3000 Mobile Fire Pump Testing & Training Specifications Municipal/County/Rural/Commercial/Industrial

BRUSH TRUCK. CET Quick Attack Unit. Ford Cab & Chassis Unit is to be installed on a Ford F550

Low Pressure Series - Accessories. High Pressure Series - Accessories

ERWC RM Shown with Optional Akron Brass Junction Box and Guide Roller

VERSAX SERIES VERSAX SELF-PRIMING 2-STAGE FIRE PUMP PORTABLE & WRAP-AROUND. Applications. Features and Benefits DATA SHEET

2017 PRV Demo Toyne Inc. == '16 PRV Pumper == CORPORATE OWNERSHIP OF MANUFACTURER

340 Series Double Suction Split Case Pumps

BELL FIRE ENGINEERS PVT. LTD.

Climas y Proyectos Leyco, S.A. de C.V.

The purchaser shall not place the apparatus into active emergency service until fully compliant with NFPA 1901.

Operation and Maintenance. S100 Series Centrifugal Fire Pumps. Table of Contents. Visit us at F /22/02 6/21/18

The purchaser shall not place the apparatus into active emergency service until fully compliant with NFPA 1901.

Owner's Manual. Model: ( ) (150 Gallon, 5.5 HP Skid Sprayer) Technical Specifications. General Information. Warranty/Parts/Service

DARLEY PUMPS CAF SYSTEMS DAVEY PORTABLES DIESEL PORTABLE FAST ATTACK SKIDS

FELD 2000 GALLON TANKER DELIVERY AND INITIAL INSPECTION

S Series PACER Pumps. PACER Pumps 5/91 Page 1 of 5. Dultmeier Sales for Omaha, NE or for Davenport, IA

SPECIFICATIONS FOR PTO DRIVEN ULTRA HIGH PRESSURE PIERCING AND FIRE FIGHTING SYSTEM L 1000 W-P SPECIFICATIONS FOR FIRE FIGHTING SYSTEM

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

8/6/2013 LX-30 MACHINES: COPYRIGHT 6/10/10 ALL RIGHTS RESERVED

The American Road Machinery Company 17, 25, 30 CUBIC YARD CHASSIS OR ROLLOFF MOUNT LEAF COLLECTOR June 2015

SECTION A. OVERALL DESIGN CHARACTERISTICS

P773-2 For Model: M773LW2 PARTS MANUAL. Marine Generators Marine Diesel Engines Land-Based Generators

CALL FOR OPTIONS AND PRICING

The following is intended to provide the basic instructions for installation, operating and maintenance of the Severe Duty Monitor.

PARTS LIST FOR AIR COMPRESSORS AC-SH20-2 AC-SV20-2 ENGINE OIL GRADE: HONDA: SAE 10W-30. Below 40 F=SAE 10W-30 ENGINE OIL CAPACITY:

The TARCO Highlander JR is heavy-duty type material spreader that can be used for a variety of light to medium duty truck applications.

S/N 1H019H - 1H310H Page 1 of 33 46" Cutting Deck Assembly

Line Body Canopy and Accessories:

You Can t Buy A Better Reel. Home Fuel Delivery In-plant Refueling Marine Refueling Off-road Vehicle/Equipment Refuelings

FITTINGS COUPLINGS BAUER TRAVIS PATTERN CLAW VICTAULIC STRAINERS MUFF STEAM & GROUND JOINTS STORZ QRT CFA MFB & NSW FIRE BRIGADE

Superior Performance

HEAVY-DUTY VALVES. *Limited to Manufacture Defects. Operating Pressure (psi) " Stainless Steel " Polymer

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

70-35-GP Portable CAFS Unit Service Parts List

SYRACUSE FIRE DEPARTMENT RFP SPECIFICATIONS FOR 3000 GALLON WATER TENDER

CRANE-DEMING VERTICAL IN-LINE INDUSTRIAL BULLETIN 3180 SECTION 38

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

Advertisement to Bidders (1) Brush Fire Truck Watertown Fire Rescue

CL Series Centrifugal Fire Pumps Installation Instructions

OWNER S MANUAL. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/5.5 HP Engine, 4-Roller Pump & Deluxe Handgun) Assembly Instructions

Agricultural & Industrial Sprayers, Utility Vehicle Sprayer Brochure

BB-4 DIESEL BB-4-D902 VEHICLE MOUNT HIGH PRESSURE 4-STAGE FIRE PUMP. Applications. Features and Benefits DATA SHEET

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

32 quarts Transmission Allison HT 740 Automatic Fluid

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

AURORA 3500 SERIES MODEL 3550 ASME/ANSI B73.1 INDUSTRIAL PROCESS PUMPS

4500C Series Vortex Pumps

SUGGESTED SPECIFICATIONS

Designing a UTV FIRE or RESCUE or FIRE RESCUE UNIT To Fit Your Departments Needs!

PB18 Series Portable Pump Assembly Service Parts List

Wilo CO-Helix Pressure Boosting Systems. Engineering Specification

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER

SEA PORT MARINE CORP.

1100 Series Multi-Stage Vertical Turbine Pumps

Repair Parts Coulter Applicator Repair Parts

NEW! BOOSTER PUMPS. HBP/HBPS series 4" horizontal booster pumps. booster pumps

Parts Manual PZ Please read the operator manual carefully and make sure you understand the instructions before using the machine.

Stackable Storage & Dispensing Systems

FLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C

PISTON RING SET STANDARD 2-1

Flippen Float Valves

Transcription:

FIRE PUMP DANKO XL SKID UNIT UPF Defender Poly Tank A Waterous 2515LE pump shall be provided and bolted directly to the specified engine and capable of the following performance: Max Pressure - 75 GPM @ 135 PSI Max Flow - 150 GPM @ 90 PSI NOTE: The above manufacturer performance rating is based on maximum full throttle with a flooded suction prior to the installation of associated piping. The impeller shall be high strength corrosion resistant bronze, fully enclosed, double hubbed to balance hydraulic thrust, and mechanically balanced to eliminate vibration. The volute shall be constructed of high strength aluminum alloy, anodized for superior corrosion resistance. A drain valve shall be located on bottom of the pump volute. The pump shall have a two (2) year warranty covering material and workmanship. Normal wear items (packing, anodes, mechanical seals, etc.) are not covered by this warranty. The pump shall be firmly mounted to the skid frame or platform behind the water tank. PUMP ENGINE A Briggs and Stratton model 356447 Vanguard V-Twin 90 OHV 18 HP engine shall be supplied and mounted to the pump. The engine shall be air cooled, constructed of Dura-Bore cast iron cylinder sleeves. It is designed to deliver a maximum output of 18 HP (13.4 kw) @ 3600 RPM. The engine shall also feature a full pressure lubrication system with an automotive style oil filter and an oil fill tube with dipstick. The engine controls shall be mounted directly on the engine and consist of a keyed electronic start/stop ignition with backup manual recoil start, manual choke, and throttle control. DISCHARGE PRESSURE GAUGE There shall be one (1), discharge pressure gauge installed in line with the plumbing. The gauge shall be a minimum of 2-1/2" in diameter with a white face and black text. PUMP ENGINE OIL DRAIN An engine oil drain valve shall be provided and installed on the engine. The oil drain valve shall have a nipple to accept 3/8" ID hose to allow draining of the engine oil. 02/14/18 Page 1 of 6

PUMP ENGINE FUEL TANK A five (5) gallon outboard fuel tank shall be supplied for the pump engine and mounted near the pump. The fuel tank shall be constructed of black high-density polyethylene (HDPE) and connected to the pump engine with an in-line carbon canister to provide low evaporative emissions in order to meet both the California Air Resource Board and EPA. PUMP PRIMER No pump primer shall be provided. PUMP SYSTEM CERTIFICATION The pump shall be tested after the pump and all its associated piping and equipment have been installed on the skid unit by the apparatus manufacturer. PLUMBING Plumbing shall be a combination of heavy duty stainless steel pipe and fittings, and high pressure rubber hose. A Danko XL stainless steel manifold shall be used for all discharge's. The Danko XL manifold is engineered to allow adding a foam system or additional discharge's easy and fast. The high pressure rubber hose is designed to handle air, mild chemicals and water and is resistant to abrasion and UV protected. The stainless steel pipe and fittings shall have a polished natural mill finish. DISCHARGE MANIFOLD A stainless steel welded pipe manifold shall be attached to the pump discharge with four (4) 1/4" bolts to facilitate all outlets and reduce friction loss. The manifold assembly shall be constructed of 2 round tubing and capable of accommodating up to two (2) 1 discharges and three (3) 1-1/2 discharge outlets. SUCTION MANIFOLD A stainless steel welded pipe manifold shall be attached to the suction side of the pump with a Victaulic clamp for easy removal for service and maintenance. The manifold shall have a tee to facilitate a 2 tank to pump and 2-1/2 intake. VALVES All valves, unless otherwise specified, shall be brass Watts full flow quarter-turn valves. 02/14/18 Page 2 of 6

TANK TO PUMP The tank to pump shall be equipped with a 2" Watts full flow, quarter turn ball valve with a flexible hose to reduce vibration of the pump engine. PUMP TO TANK/RECIRCULATE VALVE One (1) 1" tank fill/recirculate line with a 1" Watts full flow, quarter turn ball valve shall be plumbed directly from the pump discharge to the tank with a flexible hose to reduce vibration of the pump engine. INTAKE One (1) 2-1/2" male intake shall be mounted to the pump inlet. The intake shall terminate with a chrome plated 2-1/2" NPT female x 2-1/2" NH male bushing. A zinc screen will be provided to prevent foreign objects from entering the pump. CAP WITH CHAIN One (1) 2-1/2 NH vented chrome plated cap with chain shall be supplied for the intake. 1-1/2 DISCHARGE One (1) 1-1/2" NH discharge shall be provided with a 1-1/2 Watts full flow, quarter-turn valve. The discharge shall terminate with a chrome 1-1/2 NPT male x 1-1/2 NH male fitting and be directed to the rear. CAP WITH CHAIN One (1), 1-1/2" NH vented chrome cap with chain shall be supplied for the discharge. BOOSTER REEL One (1), Hannay model EF4040-17-18 steel electric booster reel(s), with a capacity of 150' of 1" booster hose shall be supplied. The reel(s) shall be painted graphite in color. A 1" Watts full flow, quarter turn valve shall be plumbed from the pump discharge and connected to the booster reel with a flexible hose to reduce vibration from the pump engine. The booster reel(s) is equipped with a standard 1" 90 degree ball bearing swivel joint with 1" female NPT threads and a standard outlet with 1" male NST threads. The reel(s) shall be capable of withstanding pressures to 1000 psi and temperature ranges from -60 F to 250 F. One (1), set of chrome guide rollers shall be mounted high on the left side of the hose reel. The rollers shall provide assistance in pulling the hose off from the reel and guiding it on after use. One (1), booster reel rewind switch shall be located on the left side of the skid unit. 02/14/18 Page 3 of 6

One (1), 1" x 150' section(s) of 300 lb. working pressure rubber booster hose coupled with 1" NH couplings shall be supplied for the booster reel(s). The booster reel shall be mounted lengthwise above the water tank and deploy to the side(s) of the apparatus. WATER TANK The water tank shall be a UPF Danko Defender XL Series tank with a capacity of 300 US gallons. (Approximate tank dimensions: 60L x 46W x 29H) The tank shall have a LIFETIME WARRANTY as supplied by the tank manufacturer. The tank shall be constructed of 1/2" thick UPF PT-2E polypropylene sheet stock with AccTuff resin. The material shall be of a certified, high quality, noncorrosive, stress relieved thermo plastic, black in color, and UV stabilized for maximum protection. The exterior of the tank shall be textured poly. All joints and seams are to be fully nitrogen welded and electronically tested for maximum strength. The unit shall incorporate transverse partitions manufactured of 3/8" UPF PT2E polypropylene (natural in color) which shall interlock with a series of longitudinal partitions constructed of 1/2" PT2E polypropylene (black in color). All swash partitions shall be so designed to allow for maximum water and air flow between compartments and are fully welded to each other as well as to the inside of the tank. The tank shall be equipped with a combination vent/overflow and manual fill tower. The fill tower shall be an 8" round by 6" high with a blue, molded cover. The cover shall be fastened to the tower with a tether to prevent loss. The tower shall be located in the rear passenger's side corner. There shall be a vent/overflow installed inside and to the extreme rear of the fill tower approximately 2" down from the top. This vent/overflow shall be schedule 40 polypropylene pipe with minimum ID of 3" and piped internally to exit out the right side tank wall. The tank cover shall be constructed of 1/2" thick PT2E polypropylene, black in color, UV stabilized, and flush mounted. The cover shall incorporate as standard two (2) mounting blocks that shall be to accommodate two (2) each sliding nut fasteners. These mounting blocks shall be welded to the cover running crosswise. The sump shall be milled into the tank floor and measure approximately 8" diameter and 1/2" deep. The sump shall not be visible from or protrude through the bottom of the tank. There shall be three (3), standard tank connections located in the rear wall of the tank. One (1), 2" NPT female tank to pump suction fitting, one (1), 1" NPT female tank fill/recirculate fitting with flow deflector, and one (1), 3/4" NPT female drain opening. 02/14/18 Page 4 of 6

TANK FLOOR PLATFORM BASE There shall be a full-width skid base manufactured of 3/4" PT2E polypropylene welded to the bottom of the tank. This base shall be 48" wide by 93" long and shall extend 31" past the tank in the rear to allow for pump mounting. The pump mounting area shall be supported by 1/2" PT2E polypropylene gussets 19" high by 29" long. The base shall have a mounted tab at the front and two (2) 1/2 drilled holes at the rear of the platform to secure directly to a truck bed without the need for any skid framework underneath. TANK DRAIN There shall be a 3/4" FNPT female tank drain located on the rear tank wall with a 3/4" stainless steel plug. VISUAL WATER TANK SIGHT LEVEL GAUGE There shall be an external visual sight gauge located on the rear wall of the tank. OPEN STORAGE COMPARTMENT There shall be an internal storage compartment built integral with the water tank and located on the left rear side of the tank. The compartment shall be open from the top of the water tank and be approximately 29" long x 11" wide x 9" deep with two (2) 1/2" drain holes. NOTE: This compartment may be converted to a 12-gallon foam cell. 12-VOLT ELECTRICAL All electrical components of the unit shall be wired to a terminal stud block with high temperature, copper, multi-strand, crosslink-coated wire enclosed in a protective loom. WORK LIGHT One (1), 12-Volt LED work light shall be mounted on the tank to light up the work area. An ON/OFF switch shall be located at the rear of the skid unit. BASIC LIMITED WARRANTY Danko Emergency Equipment Company shall warrant to each original purchaser that the apparatus is free of defects in material and workmanship for a period of one (1) year. 02/14/18 Page 5 of 6

STAINLESS STEEL PLUMBING WARRANTY Danko Emergency Equipment Company shall warrant to each original purchaser that the apparatus stainless steel plumbing shall be free of defects for a period of ten (10) years. DELIVERY The unit shall be picked-up by the purchaser at the factory FOB Snyder, NE unless other arrangements are made. 02/14/18 Page 6 of 6

BUILD DRAWING