Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Similar documents
2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Fincor Series 2230 MKII/2240

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

MaxPak Plus Analog DC V S Drive

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

CONTROL FEATURES AVAILABLE OPTIONS

17429X.00 SERIES MODELS:

TABLE OF CONTENTS SPECIFICATION CHART...8 RATIOPAX DCX/DCXplus BETA II BETAplus VEplus

Boston Gear Ratiotrol

Installation & Operation Manual

Boston Gear Ratiotrol DC Motor Speed Control

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

DC3N Non-Regenerative DC Drives

SAFTRONICS DF8 PLUS SERIES

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

DC Drive Selection Guide

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

Boston Gear Ratiotrol

Boston Gear Ratiotrol DC Motor Speed Control


Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Filtered PWM Speed Control for Permanent Magnet DC Motors

Boston Gear Ratiotrol

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

Description 1/8-7.5HP

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol

Installation and Operation Manual. *See page 6 for CE Information

WARNER ELECTRIC. Quadraline 7000 DC Drives SERVO CONTROLS STEPPER CONTROLS VOLTAGE CONDITIONING ENGINEERED SYSTEMS AC/DC DRIVES

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

DC Variable Speed Drive Panel

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

SDC,Inc. SCR-Regenerative Ac Drive

5001TCP SPEED CONTROLLER

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

Boston Gear. Adjustable-Speed Regenerative DC Motor Controllers. Installation and Operation Manual. Doc. No RBA-RG VEA-RG Series

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

Stock Variable Speed AC & DC Motor Controls & Accessories. KB Electronics, Inc. Selection Guide GS-118A

5001TCP SPEED CONTROLLER

BC141, BC142, BC142-5 & BC142-6 DC Control

TABLE OF CONTENTS WARRANTY. 1 INTRODUCTION. 2 CONTROL FEATURES. 2 HEATSINK DIMENSIONS. 2 SPEEDPOT KIT ASSEMBLY. 3 MOUNTING PROCEDURE.

Boston Gear RB Series

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

RVS-DN Digital Reduced Voltage Motor Starter

MELLTRONICS DRIVES. Single Phase Regenerative DC Drives ¼ HP TO 7½ HP INSTALLATION OPERATION MAINTENANCE

CABINET REEL OPERATING INSTRUCTIONS

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

500 CONTROL SERIES. Instruction Manual Variable Speed DC Control. Phone (317) Fax (317)

An American Control Electronics Brand. RG6xU SERIES USER MANUAL RG60U RG61U.

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

BLAZER D.C. MOTOR CONTROL

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

Series 5 Inverter NEMA 4X, IP-65 Installation and Operating Manual

KBAC SERIES Adjustable Frequency Drives for 3-Phase AC Motors NEMA-4X / IP-65

RVS-DX Digital Reduced Voltage Motor Starter

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

Installation and Operating Manual

Installation and Operation Manual

RG500 SERIES USER S MANUAL. SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

WARNER ELECTRIC. Bronco II 160 Series DC Drives SUPPORTED BY DANA CORPORATION

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

CTi Automation - Phone: Fax: Web:

Copyright 2013 Automationdirect.com Incorporated All Rights Reserved

KBIC SCR DC Motor Speed Controls

The 500 Manual Table of Contents

AC & DC Adjustable Speed Controls and Motors. MTY (81) MEX (55) QRO (442)

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

XP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

WarninG TraDeMarkS Copyright 2013, 2018 Automationdirect.com Incorporated All Rights Reserved

Focus 3N ¼ to 5HP Single Phase, Uni-Directional Non-Regenerative DC Drive

KBMD-240D MULTI-DRIVE

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

CABINET REEL OPERATING INSTRUCTIONS

PALLET MASTER (PMD) OPERATING INSTRUCTIONS

Transcription:

DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific options. Series 2230,, and drives offer many features not found on competitive drives. These features promote safety and improved performance. They include: Isolated Regulator protects internal control circuits from the AC power source, operators and equipment. The control reference input common may be grounded or connected without additional isolation to additional drives or grounded external sources. Isolation eliminates the common condition of line voltage to ground potential being present at the operator station potentiometer. External DC Signal Follower includes isolation and impedance matching circuitry to interface an externally supplied grounded or ungrounded, isolated or non isolated 0-5 VDC, 0-10 VDC or 4-20 ma DC signal source, with the motor controller reference input. This provides a linear transfer of the external signal to motor speed. TYPICAL APPLICATIONS Extruder Reliable Conveyor Rugged AC Line Starting (Auto-Restart) selection simplifies restart control wiring requirements. This selection also permits run-stop control of unidirectional models by using an external AC line contactor. Smooth starting capabilities are included. Conveyor Simple DC Tachometer Feedback provides wider speed range, improved speed regulation with load changes and reduced sensitivity to operating conditions such as line voltage variations, ambient temperature changes, motor field heating and other operating variables. The controller will automatically transfer to counter EMF voltage feedback to prevent run away if the tachometer circuit is disconnected. Tachometers producing 7 to 150 VDC at maximum motor speed may be used. Mixer Flexible 2230 Analog DC Drive 1/8 to 5 hp (115-230 VAC) Non-Regen and Regen Models, Bookshelf or NEMA 4/12 Tachometer or Armature Feedback Complete Motor Solutions Contact factory for Operator Stations 284

CHOOSE NON-REGEN OR REGENERATIVE Non-regenerative drives are used when friction or a dynamic brake stopping is adequate. A contactor may be used to achieve reversing operation. Non-regen drives are less expensive than Regen drives when reversing is not required. Regenerative drives include static reversing and are used when you need four quadrant control or Forward & Reverse operation from a bidirectional control signal (+/- 10 VDC). It will stop the load smoothly and faster than a dynamic brake for fast stop or emergency stop requirements and it will regenerate power to the supply if the load is overhauling (wanting to go faster than the motor set speed). CHOOSE DRIVE SERIES Now choose the drive series from either Non-Regen or Regen product pages. The chart below compares features and horsepower ratings, with the simplest and least expensive drive at the top and highest horsepower range and flexibility towards the bottom. Order String 2 x x x x x x Operator : 0 = No 1 = Speed Pot, Run-Stop-Jog 2 = Speed Pot, Run-Stop-Jog, & Fwd-Rev Switch Reversing 3 = Speed Pot, Run-Stop-Jog, & Fwd-Rev Contactor Reversing 7 = Speed Pot, Run-Stop-Jog, & Auto-Manual Enclosure: No Letter =, P = Enclosed (top cover) Armature Contactor: No Letter = None, A = Armature Contactor Reversing with DB, B = Armature Contactor with DB Current Step Drive Series Revision Level 1 = 2120 Ultra Compact, 2 = 2230 Regen Feature Rich, 3 = Non-Regen Full Featured, 6 = Non-Regen Feature Rich 2 = Single Phase Input Drive Model Single Phase DC Selection Chart Series 2120 Non-Regenerative Basic Drive Non-isolated Speed Input Full Featured Isolated Speed & Torque Input Feature Rich Isolated Speed & Torque Input with Monitoring Output 2230 Regenerative Feature Rich Isolated Speed & Torque Input with Monitoring Output Horsepower Contact your local Distributor, Control Techniques Representative or see for upgrade and cross reference information regarding Focus, Puma or Lynx series DC drives. 285

Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor. These drives may provide speed or torque control from a potentiometer or unidirectional (0-10 VDC or 4-20 ma) control signal. Reversing requires a switch or contact closure to initiate the change. Upon the reversing signal, the drive will allow the motor to coast to a stop (or perform a control stop under a decel ramp with control stop option) or utilize a dynamic braking resistor to pull it to a stop before switching the motor leads with a contactor and starting the motor in the opposite direction. Series 2120 Series 2100 drives feature compact size and lowest pricing. units are dimensionally interchangeable with many competitive units and are ideal for the OEM or panel builder who builds a custom system by integrating the drive into an enclosure with special logic or auxiliary control devices. NEMA 1 enclosed units are complete selfcontained packages ready for wall or machine mounting. 2122H 2121 & 2122 Enclosed 1/8 to 3 hp (115-230V) Budget Priced Speed Control Current Limit UL Listed 2123 RATINGS: 1/8 TO 3 hp (115-230 VAC) Series 2100 Non-Regenerative DC Drives Model Motor Input Output - HP 2 DC Volts Amps AC Volts Amps Order Code Arm Field Arm Field 1/8-1/2 115 8.7 90 50/100 5.4 1.0 2121 1/8-1/2 115 8.7 90 50/100 5.4 1.0 1/2-1.0 230 8.8 180 100/200 5.5 1.0 2122 1 1/8-1.0 115 15 90 50/100 10.5 1.0 2122H 1/8-1.0 115 15 90 50/100 10.5 1.0 1/2-3.0 230 24 180 100/200 16 1.0 2123 NEMA 1 Enclosed 1/8-1/2 115 8.7 90 50/100 5.4 1.0 2121P1 1/2-1.0 230 8.7 180 100/200 5.4 1.0 2122P1 (2) Units may be easily recalibrated using trimpots for any standard rating within the hp range. Option Description Knob and Dial Plate Kit This option provides a knob and a dial face graduated 0-100% for use with the potentiometer provided with Series 2120 chassis drives. External Signal Follower/Isolation For use with isolated or non isolated 4-20 ma DC, 0-10 VDC signals. Includes a scaling potentiometer for offset adjustment. Dimensions 1.5 (38) X 3.38 (86) X.75 (19). Order Code 106409401 2067109 286

Series 2120 SPECIFICATIONS: Operating Conditions Horsepower 1/8 thru 3 hp, Trim Pot Selectable Line Voltage 115-230 VAC ±10%, Bi Voltage Input* Rated Frequency 50/60 Hz ±2% Enclosure, NEMA 1 Ambient Temperature 0 40 C (32 F - 104 F) (Enclosed) 0 55 C (32 F - 131 F) () Altitude 1000 m (3,300 ft) Relative Humidity 95% Non condensing Overload Capacity 150% for 1 minute DIMENSIONS Weight ().5 lb..23 kg 2121 & 2122 Enclosed 1.64 (42 mm) Weight (Enclosed) 1 lb..45 kg 3.00 (76.2 mm) Regulator Function Power Conversion Field Supply Protection Speed Regulation Standard Features Speed Regulated 2 SCR plus Freewheeling Diode Full Wave MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse Armature or DC Tach Feedback* 3.55 (90 mm) Variable Speed DC Drives 9.00 (228.6 mm) Control Control Logic Power Common for Maintained Switch Speed Potentiometer 5K Ohms, ½ Watt Input Reference 0 10 VDC Speed Regulation 2% with Armature Feedback (95% Load Change) 1% with Tachometer Feedback* 2122H Weight ().5 lb..23 kg 2 (50.8 mm) FUSE TYPE MDA10 10A, 250V 3.12 (79.25 mm) Adjustments Maximum Speed Minimum Speed Current Limit IR Compensation Acceleration/Deceleration 60% 100% of Motor Base Speed 0% 40% of Motor Base Speed 0 150% of Full Load 0 100% Boost 0-4 Seconds* Weight () 1.87 1 lb..45 kg (48 mm) Controller (only) 98% With Motor (typical) 85% Efficiency 3.55 (90 mm) UL and cul Approvals & Listings * The 2121, 2121P1 and 2122P1 are single input voltage (115, 115 & 230 VAC respectively), do not offer DC Tach Feedback, and have fixed acceleration and deceleration rates. 2123 7 (178 mm) 287

Series Series drives features a fully isolated regulator using surface mount technology. It includes an isolated customer run contact, low voltage operator control circuitry, and full wave power conversion. Bookcase 1/8 to 5 hp (115-230V) Fully Isolated Regulator Speed or Torque Control 0-10 VDC or 4-20 ma Input Signal Fused Input Line Start (Auto Restart) Dual Field Supply Tachometer Input standard Enclosed Open RATINGS: 1/8 TO 5 hp (115-230 VAC) Series Non-Regenerative DC Drives Model w/o Operator Bookcase w/o Operator NEMA 4/12 w/o Operator NEMA 4/12 with Integral Operator Motor HP AC Volts Input Amps DC Volts Output Amps Arm Field Arm Field 1/2-3.0 230 22 180 100/200 15.1 1.0 1/2-3.0 230 22 180 100/200 15.1 1.0 Run-Stop, (Basic) Run-Stop, Arm. Cont. DB Run-Stop, Arm. Cont., Rev. & DB Order Code Order Code Order Code 2331 2331B 2331A 2332 2332B 2332A 2335 2235B 2235A 2336 2336B 2336A 2331P0 2331BP0 2331AP0 2331P1* 2331BP1* 2331AP3 2331P2* Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230VAC but may be reconnected for 115VAC. * P1, BP1, & P2 have additional Jog controls. 2331P2 includes switch reversing (not contactor) without DB. 288

Series SPECIFICATIONS: Horsepower Operating Conditions 1/8 thru 3 hp, Jumper Selectable Line Voltage 115-230 VAC ±10%, Jumper Selectable Rated Frequency 50/60 Hz ±2% Ambient Temperature Enclosure, Bookcase, NEMA 4/12 Altitude Relative Humidity Overload Capacity Isolated Regulator Circuit Regulator Function Power Conversion Field Supply Protection Speed Regulation Line Start Diagnostic LED Option Connector 0 40 C (32 F - 104 F) (Enclosed) 0 55 C (32 F - 131 F) () 1000 m (3,300 ft) 95% Non condensing 150% for 1 minute (UL Listed Motor Overload Protection) (120% Timing Threshold) Standard Features Grounded I/O signals possible Speed or Torque selectable 4 SCR plus Freewheeling Diode Full or Half Wave MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse Armature or DC Tach Feedback Selectable for Auto Restart Green Normal Red Current Limit Connects Additional Option Boards DIMENSIONS Weight (Enclosed) 3 lbs. 1.56 kg 5 (127 mm) Enclosed 5.25 (133 mm) 9.5 (231 mm) Control Logic Power Speed Potentiometer Input Reference Control 24 VDC for Maintained Switch or Push button Operation 5 KOhms, ½ Watt 0 10 VDC or 4 20 ma Speed Regulation 2% with Armature Feedback (95% Load Change) 0.5% with Tachometer Feedback Bookcase Weight (Bookcase) 1 lb..45 kg 1.75 (43 mm) Weight () 3 lbs. 1.36 kg 5 (127 mm) Adjustments Maximum Speed Minimum Speed Current Limit IR Compensation Acceleration/Deceleration 50% 100% of Motor Base Speed 0% 40% of Motor Base Speed 0 150% of Full Load 0 100% Boost 0.2 30 Seconds 8.85 (218 mm) 9.5 (241 mm) Controller (only) 98% With Motor (typical) 85% Efficiency UL and cul Approvals & Listings 289

Terminal Diagram: Series TB1 TB2 Minimum Speed Speed Ref Input Speed Ref Pot Motor Armature Half Wave Field +10V Ref Ext Current Ref Input Current Loop Follower Input Tachometer Fdbk Input Run Enable Input (+24 VDC) +24 VDC Run Relay N.O. Contacts Run Relay N.O. Contacts 4-20 ma Torque Ref Pot Terminal Description TB1 L1 Line Voltage Input 115 or 230 VAC J1 Selectable L2 Line Voltage Input 115 or 230 VAC J1 Selectable F+ Field Voltage Output +100 VDC @ 115 VAC or +200 VDC @230 VAC Input F/2 Field Voltage (Half-Wave) Output +50 VDC @ 115 VAC or +100 VDC @230 VAC Input F- Field Voltage Output Field Minus Output A1 Armature + Output 0 to +90 VDC @ 115 VAC or 0 to +180 VDC @ 230 VAC Input A2 Armature - Output Armature Minus Output TB2 1 Speed Reference Pot 0 End With On-board Min Speed Pot Active 2 Speed Reference Input 200 KΩ Input Resistance 3 +10V Reference Output 5mA max 4 External Current Reference Input FWD Refer to DIP Switch SW3-5 Isolated From Line Can be connected to Earth 6 Current Loop Follower Input Refer to DIP Switch SW3-2 (1 5 ma, 4 20 ma, 5 50 ma) 7 Tachometer Input (Speed Feedback) Polarity Insensitive for Reversing Applications (3-30 Vdc, 31-175 VDC) 8 Enable Input (+24 VDC) Run Relay 24 VDC @ 6ma Input 9 +24 VDC For drive enable use only 10 Run Relay N.O. Contacts Form A Contact Rated 0.5 A @ 115 VAC 11 Run Relay N.O. Contacts or 2 A @ 30 VDC 290

Series Series drives feature a fully isolated regulator using surface mount technology. It includes additional inputs and outputs with advanced control capabilities. Enclosed 1/8 to 5 hp (115 230 VAC) Fully Isolated Regulator Speed or Torque Control 0 10 VDC or 4 20 ma input signal PID / Speed Trim Control Monitoring Output (0 10 VDC or 4 20 ma) Line Start /Auto Restart Enable/Disable Dual Field Supply DC-Tachometer Input RATINGS: 1/8 TO 5 hp (115-230 VAC) Series Non-Regenerative DC Drives Model Bookcase w/o Operator NEMA 4/12 w/o Integral Operator NEMA 4/12 with Integral Operator Motor HP Input Output Open Run-Stop, (Basic) Run-Stop, Arm. Cont. DB Run-Stop, Arm. Cont., Rev. & DB AC Volts Amps DC Volts Amps Order Code Order Code Order Code Arm Field Arm Field 1/2-3.0 230 22 180 100/200 15.1 1.5 1/2-5.0 230 32 180 100/200 25 2.0 1/2-5.0 230 32 180 100/200 25 2.0 1/2-2.0 230 15.8 180 100/200 10.5 1.0 1/2-5.0 230 32 180 100/200 25 2.0 1/2-2.0 230 22 180 100/200 15.1 1.5 1/2-5.0 230 32 180 100/200 25 2.0 2611 2611B 2611A 2612 2612B 2612A 2613 2613B 2613A 2615 2615B 2615A 2611P0 2611BP0 2611AP0 2613P0 2613BP0 2613AP0 2611P1* 2611BP1* 2611AP3* 2613P1* 2613BP1 2613AP3* 2611P7 2613P7 2611BP7 2613BP7 2611P2* Manual / Auto Switch. Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230 VAC but may be reconnected for 115 VAC. * P1, PB1, AP3, P2 have additional Jog controls. 2611P2 includes switch reversing (not contactor) without DB. 291

Series SPECIFICATIONS: DIMENSIONS 2613Px Enclosed and 2613 see page 293 Horsepower Line Voltage Operating Conditions Rated Frequency 50/60 Hz ±2% Ambient Temperature 1/8 thru 5 hp, Jumper Selectable 115-230 VAC ±10%, Jumper Selectable Enclosure, Bookcase, NEMA 4/12 Altitude Relative Humidity Overload Capacity Isolated Regulator Function Regulator Function Power Conversion Field Supply Protection Speed Regulation Line Start Controlled Stop Zero Speed Indication Speed Regulation Node Speed Outputs Torque Outputs Diagnostic LED Option Connector 0 40 C (32 F - 104 F) (Enclosed) 0 55 C (32 F - 131 F) () 1000 m (3,300 ft) 95% Non condensing 150% for 1 minute (UL Listed Motor Overload Protection File # E184521) (120% Timing Threshold) Standard Features Grounded I/O signals possible Speed or Torque selectable 4 SCR plus Freewheeling Diode Full or Half Wave MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse Armature or DC Tach Feedback Selectable for Auto-Restart Provides ramp to stop function Open Collector Active Low External PID Input or Speed Trim 0 10 VDC and 4 20 ma 0 10 VDC and 4 20 ma Green Normal Red Current Limit Connects Additional Option Boards Enclosed Weight (Bookcase) 1 lb..45 kg 1.75 (43 mm) Weight (Enclosed) 3.25 lbs. 1.48 kg Weight () 3 lbs. 1.36 kg 5 (127 mm) 5 (127 mm) 5.25 (133 mm) 9.5 (241 mm) Control 8.85 (218 mm) Control Logic Power 24 VDC for Maintained Switch or Push button Operation Speed Potentiometer 5 kohms, ½ Watt Input Reference 0 10 VDC or -10 +10 VDC Speed Regulation 2% with Armature Feedback (95% Load Change) 0.5% with Tachometer Feedback Adjustments Maximum Speed 50% 100% of Motor Base Speed Minimum Speed 50% 40% of Motor Base Speed Current Torque Limit 0% 150% of Full Load IR Compensation 0 10% Boost Acceleration/Deceleration 0.1 30 Seconds Voltage (Speed) Stability Speed Gain Fine Tune Current (Torque) Stability Current Gain Fine Tune 2615 Bookcase 9.5 (241 mm) Controller (only) 98% With Motor (typical) 85% Efficiency 292 UL and cul Approvals & Listings

20 100 Series 2613 & 2233 5 hp drive dimensions The new 5 hp rating in the 2613 non-regenerative series and the 2233 regenerative series combine industry leading electronics with the Control Techniques Focus series enclosure to achieve more customer value. Standard features include a fully isolated circuit board using surface mount technology, speed or torque control, PID/Speed Trim control, Monitoring Output, and DC Tachometer Input. Please see the respective series and 2230 series sections for specifications and more details regarding these drives.. DIMENSIONS 2613 2233 Enclosed 2613 2233 40 60 0 80 293

Terminal Diagram: Series TB1 TB2 Motor Armature Terminal Description Half Wave Field Min Speed Speed Ref Input +10V Ref Ext Current Ref Input Current Common Current Loop Follower Input Tachometer Fdbk Input Run Enable Input (+24 VDC) +24 VDC Run Relay N.O. Contacts Run Relay N.O. Contacts Controlled Stop Input Zero Speed Output Speed Reg Node Input Cur. (4 to 20 ma) Output Speed 0 to +10 VDC Output Speed Cur. (4 to 20 ma) Output Torque 0 to +10 VDC Output Torque Speed Ref Pot Torque Ref Pot 4-20 ma Controlled Stop K 294 TB1 TB2 L1 Line Voltage Input 115 or 230 VAC J1 Selectable L2 Line Voltage Input 115 or 230 VAC J1 Selectable F+ Field Voltage Output +100 VDC @ 115 VAC or +200 VDC @230 VAC Input F/2 Field Voltage (Half-Wave) Output +50 VDC @ 115 VAC or +100 VDC @230 VAC Input F- Field Voltage Output Field Minus Output A1 Armature + Output 0 to +90 VDC @ 115 VAC or 0 to +180 VDC @ 230 VAC Input A2 Armature - Output Armature Minus Output 1 Speed Reference Pot 0 End With On-board Min Speed Pot Active 2 Speed Reference Input 200 KΩ Input Resistance 3 +10V Reference Output 5ma max 4 External Current Reference Input Refer to DIP Switch SW3-2 (1 5 ma, 4 20 ma, 5 50 ma) 5 Isolated From Line Can be connected to Earth 6 Current Loop Follower Input Refer to DIP Switch SW3-2 (1 5 ma, 4 20 ma, 5 50 ma) 7 Tachometer Input (Speed Feedback) Polarity Insensitive for Reversing Applications (3-30 VDC, 31-175 VDC) TB2 Continued 8 Enable Input (+24 VDC) Run Relay 24 VDC @ 6 ma Input 9 +24 VDC For drive enable use only 10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115 11 Run Relay N.O. Contacts VAC or 2A @ 30 VDC 12 Controlled Stop Input (+24 VDC) Momentary +24 VDC Input to Initiate Controlled (Ramp) to Stop 13 Zero Speed Indication Output Open Collector, Active Low, Rated 24 VDC @ 50 ma 14 Speed Regulator Node Input Speed Trim or External PID Input (Bypasses Accel/Decel Ramps) 15 Current Loop Output 4 to 20 ma Speed (Arm Volts) 16 Current Loop Output 4 to 20 ma Speed (Arm Volts) 17 Voltage Output 0 to 10 VDC Speed (Arm Volts) 18 Voltage Output Common Isolated From Line Can be connected to Earth 19 Current Loop Output 4 to 20 ma Torque 20 Current Loop (Arm Amps) 21 Voltage Output 0 to 10 VDC Load (Arm Amps) 22 Voltage Output Common Isolated From Line Can be connected to Earth

20 40 60 0 100 80 Regenerative DC Drives Regenerative adjustable speed drives also known as four-quadrant drives, are capable of controlling not only the speed and direction of motor rotation, but also the direction of motor torque. This is illustrated below. TYPICAL APPLICATIONS Material Payoff Performance The term regenerative describes the ability of the drive under braking conditions to convert the mechanical energy of the motor and connected load into electrical energy which is returned (or regenerated) to the AC power source. When the drive is operating in Quadrants I & III, both motor rotation and torque are in the same direction and it functions as a conventional non-regenerative drive. The unique characteristics of a regenerative drive are apparent in Quadrants II & IV. In these quadrants, the motor torque opposes the direction of motor rotation which provides a controlled braking or retarding force. A high performance regenerative drive, such as the Series 2230, is able to switch rapidly from motoring to braking modes while simultaneously controlling the direction of motor rotation. Conveyor Reliable QUADRANT II QUADRANT I MOTOR ROTATION QUADRANT III QUADRANT IV NOTE: TORQUE ARROWS SAME DIRECTION MOTORING (PULLING) ARROWS OPPOSITE DIRECTION BRAKING (HOLDING) Regenerative drives provide reversing without the use of a contactor. This reduces system cost while eliminating moving parts and greatly improving reversing and braking performance. Although the regenerative drive eliminates the requirement of a contactor for reversing or normal operational braking, a contactor is used if dynamic braking is still required. Although regenerative braking stops the motor and it s load faster under normal conditions, a dynamic brake may be required to stop the motor and it s connected load in emergency stop conditions such as drive failure or if the drive enable is removed before the motor comes to a complete stop. 295

Series 2230 Series 2230 regenerative drives are ideal for your more demanding application with ratings up to 5 horsepower. Regenerative drives handle reversing without contactors and are able to stop faster. They feature a fully isolated regulator using surface mount technology. 2230 Enclosed 1/8 to 5 hp (115-230V) Fully Isolated Regulator Speed or Torque Control 0-10 VDC or +/- 10 VDC Input Signal PID / Speed Trim Control Current Stability Adjust Speed or Current Monitoring (0-10 VDC or 4-20 ma) Fused Input Line Start / Auto Restart Enable / Disable Dual Field Supply DC Tachometer Input Diagnostic LED RATINGS: 1/8 TO 5 hp (115-230 VAC) Series 2230 Regenerative DC Drives Model w/o Integral Operator Book Case w/o Integral Operator NEMA 4/12 w/o Operator NEMA 4/12 with Integral Operator Motor HP Open Input Output Run-Stop- Jog * Bookcase Run-Stop-Jog, DB ** AC Volts Amps DC Volts Amps Order Code Order Code Arm Field Arm Field 1/2-2.0 230 15.8 180 100/200 11.6 1.0 1/2-3.0 230 22 180 100/200 15.1 1.0 1/2-5.0 230 32 180 100/200 25 2.0 1/2-2.0 230 15.8 180 100/200 11.6 1.0 1/2-3.0 230 22 180 100/200 15.1 1.0 1/2-2.0 230 15.8 180 100/200 11.6 1.0 1/2-5.0 230 32 180 100/200 25 2.0 1/2-2.0 230 15.8 180 100/200 11.6 1.0 1/2-5.0 230 32 180 100/200 25 2.0 2231 2231B 2232 2232B 2233 2233B 2235 2235B 2236 2236B 2231P0 2233P0 2231P1 2233P1 Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230 VAC but may be reconnected for 115 VAC. 2231BP0 2233BP0 2231BP1 2233BP1 296 * Run-Stop-Jog with Static (Contactor-less) Reversing using -100 to 100% Speed Potentiometer ** Run-Stop-Jog with Armature Contactor and Dynamic Braking. Reversing uses -100 to 100% Speed Potentiometer

Series 2230 SPECIFICATIONS: Operating Conditions Horsepower 1/8 thru 5 hp, Jumper Selectable Line Voltage 115-230 VAC ±10%, Jumper Selectable Enclosure, Bookcase, NEMA 4/12 Rated Frequency 50/60 Hz ±2% Selectable Ambient Temperature 0 40 C (32 F - 104 F) (Enclosed) 0 55 C (32 F - 131 F) () Altitude 1000 m (3,300 ft) Relative Humidity 95% Non condensing Overload Capacity 150% for 1 minute (UL Listed Motor Overload Protection File # E184521) (120% Timing Threshold) Isolated Regulator Circuit Regulator Function Power Conversion Field Supply Protection Speed Regulation Line Start Controlled Stop Zero Speed Deadband Zero Speed Indication Direction Indication Speed Regulator Node Speed Outputs Torque Outputs Diagnostic LED Option Connector Standard Features Grounded I/O signals possible Speed or Torque selectable 8 SCR Full Wave - Four Quadrant Full Wave MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse Armature or DC Tach Feedback Selectable for Auto-Restart Provides Ramp to Stop Function Selectable 2% or Off Open Collector Active Low Open Collector Active Low = FWD External PID Input or Speed Trim -10 10 VDC and 4 20 ma -10 10 VDC and 4 20 ma Green Normal Red Current Limit Connects Additional Option Boards Control Control Logic Power 24 VDC for Maintained Switch or Push button Operation Speed Potentiometer 5 kohms, ½ Watt Input Reference 0 10 VDC or -10 +10 VDC Speed Regulation 2% with Armature Feedback (95% Load Change) 0.5% with Tachometer Feedback DIMENSIONS 2230 Enclosure Weight () 3 lbs. 1.36 kg 5 (127 mm) 2230 2233Px Enclosed and 2233 see page 293 2230 9.5 (241 mm) Weight (Enclosed) 3 lbs. 1.36 kg 5 (127 mm) 2230 5.25 (133 mm) Weight (Bookcase) 1 lb..45 kg 1.75 (43 mm) 9.5 (241 mm) Maximum Speed Current Limit FWD Current Limit REV IR Comp/Tach Scaling Acceleration/Deceleration Voltage (Speed) Stability Current Stability FWD Current Stability REV Efficiency Controller (only) 98% With Motor (typical) 85% Adjustments 50% 100% of Motor Base Speed 0 150% of Full Load 0 150% of Full Load 0 10% IR or 0 100% Tach 0.1 30 Seconds Speed Gain Fine Tune Current Gain FWD Fine Tune Current Gain REV Fine Tune 2230 Bookcase 8.85 (218 mm) UL and cul Approvals & Listings 297

Terminal Diagram: Series 2230 Terminal Description TB1 TB2 L1 Line Voltage Input 115 or 230 VAC J1 Selectable L2 Line Voltage Input 115 or 230 VAC J1 Selectable F+ Field Voltage Output +100 VDC @ 115 VAC or +200 VDC @230 VAC Input F/2 Field Voltage (Half-Wave) Output +50 VDC @ 115 VAC or +100 VDC @230 VAC Input F- Field Voltage Output Field Minus Output A1 Armature Output -90 to +90 VDC @ 115 VAC or -180 to A2 Armature Output +180 VDC @ 230 VAC Input TB1 1 Speed Reference Pot 0 End Speed Pot Common for Unidirectional Operation 2 Speed Reference Input 200 KΩ Input Resistance 3 +10V Reference Output 5 ma max 4-10V Reference Output 5 ma max 5 External Current Reference Input FWD 6 External Current Reference Input REV 7 Tachometer Input (Speed Feedback) Refer to DIP Switch SW3-2 Refer to DIP Switch SW3-7 3-30 VDC, 31-175 VDC Speed Ref Input +10V Ref -10V Ref Ext Current Ref Input FWD Ext Current Ref Input REV Tachometer Fdbk Input Run Enable Input (+24 VDC) +24 VDC Run Relay N.O. Contacts Run Relay N.O. Contacts Controlled Stop Input Zero Speed Output Speed Reg Node Input Cur. (4 to 20 ma) Output Speed -10 to +10 VDC Output Speed Direction Output Cur. (4 to 20 ma) Output Torque -10 to +10 VDC Output Torque TB2 Continued TB2 Speed Ref Pot 8 Enable Input (+24 VDC) Run Relay Torque Ref Pot FWD 24 VDC @ 6 ma Input 9 +24 VDC For drive enable use only Torque Ref Pot REV Controlled Stop 10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115 11 Run Relay N.O. Contacts VAC or 2A @ 30 VDC 12 Controlled Stop Input (+24 VDC) Momentary +24 VDC Input to Initiate Controlled (Ramp) to Stop 13 Zero Speed Indication Output Open Collector, Active Low, Rated 24 VDC @ 50ma 14 Speed Regulator Node Input Speed Trim or External PID Input (Bypasses Accel/Decel Ramps) 15 Current Loop Output 4 to 20 ma Speed (Arm Volts) 16 Current Loop Output 4 to 20 ma Speed (Arm Volts) 17 Voltage Output -10 to 10 VDC Speed (Arm Volts) 18 Direction Indicator Output Open Collector, Active Low for FWD; Rated 24 VDC @ 50 ma 19 Current Loop Output 4 to 20 ma Torque 20 Current Loop (Arm Amps) 21 Voltage Output -10 to 10 VDC Load (Arm Amps) 22 Voltage Output Common Isolated From Line Can be connected to Earth K K 298