CRE15-01 A-F-A-E-HQQE 1x HZ

Similar documents
CRE10-02 A-A-A-E-HQQE 1x HZ

CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

CRE45-1 A-F-A-E-HQQE 3x HZ

Grundfos pump

CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

CRE A-F-A-E-HQQE 3x HZ

CRE32-3 AN-F-A-E-HQQE 3x HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CRNE15-03 A-FGJ-G-V-HQQV 3x HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRE A-F-A-E-HQQE 3x HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CRE20-08 A-F-A-E-HQQE 3x HZ

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

CR A-F-A-V-HQQV 3x400/ HZ

NB80-160/161 A-F2-A-BQQE

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CR A-F-A-V-HBQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN15-03 A-P-G-V-HQQV 3x400D 50 HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

CRN A-F-G-V-HQQV 3x400/ HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CR A-F-A-E-HQQE 3x400D 50 HZ

CR45-3 A-F-A-E-HQQE 3x400/ HZ

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

NBE50-250/205 A-F2-A-BAQE

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

CR15-01 A-F-A-E-HQQE 3x230/ HZ

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR15-14 A-F-A-E-HQQE 3x400/ HZ

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRN3-7 A-P-G-E-HQQE 3x230/400 50HZ

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

CR1-4 A-A-A-E-HQQE 3x230/400 50HZ

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

CR5-9 A-A-A-E-HQQE 3x230/400 50HZ

CRN10-02 A-P-G-E-HQQE 3x230/ HZ

NKE80-160/175A2F2AE-SBQQE

TPED /4-A-F-A-BQQE 3X400 50HZ

CRN A-F-G-V-HQQV 3x400/ HZ

NB /193 A-F2-A-BAQE

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

TP /2-A-F-A-BQQE 400D 50HZ

NK /310A2F1AE-SBAQE

TPE /4-A-F-A-BAQE 3X400 50HZ

CRN5-22 A-P-G-V-HQQV 3x400D 50HZ

TPE /2-S-A-F-A-BAQE 3X400 50HZ

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

Hydro MPC-E 2CRIE L GNL

TP /4-A-F-A-BQQE 400Y 50HZ

CRN5-5 A-FGJ-G-V-HQQV 3x230/400 50HZ

TP /2-A-F-A-BAQE 400D 50HZ

TPED /4-S-A-F-A-BAQE 3X400 50HZ

NBE40-125/139 AS-F2-A-BAQE

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ

CRNE AN-F-G-E-HQQE 3x HZ

NB /263 AS-F2-A-BAQE

TPE N-A-F-A-GQQE

TPE N-A-F-A-GQQE

NB /438 A-F1-A-GQQE

Transcription:

GRUNDFOS DATA BOOKLET CRE15-1 A-F-A-E-HQQE 1x22-24 5 HZ Grundfos Pump 96512684 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/cre15/96512684/cre-15-1-a-f-a-e-hqqe.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CRE 15-1 A-F-A-E-HQQE Product No.: 96512684 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. The pump head and base are in cast iron all other wetted parts are in stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via DIN flanges. The pump is fitted with a 1-phase, fan-cooled asynchronous motor. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. Further product details An external sensor can be connected if controlled pump operation based on for example flow, differential pressure or temperature is required. A control panel on the motor terminal box enables setting of required setpoint as well as setting of pump to "Min." or "Max." operation or to "Stop". The control panel has indicator lights for "Operation" and "Fault". Communication with the pump is possible by means of the Grundfos GO Remote or the R1 remote control (accessories). The remote controls enable further settings as well as reading out of a number of parameters such as "Actual value", "Speed", "Power input" and total "Power consumption". Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. 1/8

The pump head, pump head cover and flange for motor mounting is made in one piece. The pump head has a combined 1/2" priming plug and air vent screw. The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: EPDM (ethylene-propylene rubber) EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils. The shaft seal is screwed into the pump head. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The base is made of cast iron. The flanges and base are cast in one piece. The discharge side of the base has a drain plug. The pump is secured to the foundation by four bolts through the base plate. Motor 2/8

The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with tapped-hole flange (FT). Motor mounting designation in accordance with IEC 634-7: IM B 14 (Code I) / IM 361 (Code II). Electrical tolerances comply with IEC 634. The motor requires no external motor protection. The motor control unit incorporates protection against slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. The terminal box holds terminals for these connections: - pump start/stop input (potential-free contact) - remote setpoint setting via analog signal, -1 V, (4)-2 ma - 1 V voltage supply for setpoint potentiometer, Imax = 5 ma - one analog sensor input, -1 V, (4)-2 ma - 24 V voltage supply for sensor, Imax = 4 ma - one analog output - three digital inputs - one potential-free fault signal relay with changeover contact, reporting "Fault", "Operation" or "Ready" - RS-485 GENIbus connection. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Materials: Pump housing: Impeller: Water 253.. 393 K 293 K 998.2 kg/m³ 2789 rpm 17 m³/h 9.5 m HQQE CE,TR Cast iron EN-JL13 ASTM A48-3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 16 bar / 12 C 16 bar / -2 C Flange standard: DIN Pipe connection: DN 5 Pressure stage: PN 16 Flange size for motor: FT1 Electrical data: Motor type: 8B Number of poles: 2 Rated power - P2: 1.1 kw Power (P2) required by pump: 1.1 kw 3/8

Position Qty. Description Mains frequency: 5 Hz Rated voltage: 1 x 2-24 V Rated current: 8,2-6,8 A Cos phi - power factor:,97 Rated speed: 36-284 rpm Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Others: Minimum efficiency index, MEI :.7 Net weight: 45 kg Gross weight: 48 kg 4/8

96512684 CRE 15-1 5 Hz H [m] 14 CRE 15-1, 1*23 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 13 1 % 12 11 1 1 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 25 % 1 2 4 6 8 1 12 14 16 18 2 22 P [kw] 1.2 Q [m³/h] NPSH [m] 6 1. P1 5.8.6 P2 4 3.4 2.2 1. 5/8

Description Value Product name: CRE 15-1 A-F-A-E-HQQE Product No: 96512684 EAN number: 57396616391 Technical: Speed for pump data: 2789 rpm Rated flow: 17 m³/h Rated head: 9.5 m Impellers: 1 Shaft seal: HQQE Approvals on nameplate: CE,TR Stages: 2 Pump version: A Model: A Materials: Pump housing: Impeller: Material code: Code for rubber: Cast iron EN-JL13 ASTM A48-3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 A E Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 16 bar / 12 C 16 bar / -2 C Flange standard: DIN Connect code: F Pipe connection: DN 5 Pressure stage: PN 16 Flange size for motor: FT1 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253.. 393 K 293 K 998.2 kg/m³ Electrical data: Motor type: 8B Number of poles: 2 Rated power - P2: 1.1 kw Power (P2) required by pump: 1.1 kw Mains frequency: 5 Hz Rated voltage: 1 x 2-24 V Rated current: 8,2-6,8 A Cos phi - power factor:,97 Rated speed: 36-284 rpm Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Motor protec: PTC Motor No: 8575515 H [m] 13 12 11 1 9 8 7 6 5 4 3 2 1 P [kw] 231 4 1..5. 9 1 % 25 % 5 1 15 2 Group 3 167 178 NC C ND N PE L Group 2 13 176 3 ø18.1 2 215 256 ø65-1 V ø125 1:Digital input ø165 CRE 15-1, 1*23 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 4 x ø13.5 9:GND (frame) /4-2 ma 4-2 ma 8:+24 V Group 1 7:Sensor input /1 B:RS-485B Y:Screen B Y A 1 9 8 7 A:RS-485A STOP 6:GND (frame) RUN 5:+1 V 4:Setpoint input /4-2 ma -1 V 3:GND (frame) 1K Q [m³/h] 2:Start/stop P1 P2 6 5 4 3 2 eta [%] 1 9 8 7 6 5 4 3 2 1 NPSH [m] 1 5 Others: Minimum efficiency index, MEI :.7 Net weight: 45 kg Gross weight: 48 kg Config. file no: 9659463 6/8

96512684 CRE 15-1 5 Hz 13 176 3 215 256 ø65 4 x ø13.5 9 2 ø125 ø165 167 178 ø18.1 4 231 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 7/8

96512684 CRE 15-1 5 Hz NC C ND Group 2 N PE L Group 3-1 V /4-2 ma 4-2 ma 1:Digital input 9:GND (frame) /1 1 9 8 7 B Y A 8:+24 V 7:Sensor input B:RS-485B Y:Screen A:RS-485A Group 1 STOP /4-2 ma -1 V RUN 1K 6:GND (frame) 5:+1 V 4:Setpoint input 3:GND (frame) 2:Start/stop 6 5 4 3 2 Note! All units are in [mm] unless others are stated. 8/8

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89