Engine 3 Installation

Similar documents
Installing Power Components

Power and Cooling. Chassis Power System

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

SAVE THESE INSTRUCTIONS

UNPWM-U-Type Universal Wall Mount Patch Panel Instructions

WaltZilla TM Installation and Operation Guide

UNP-U-Type Universal Panel Instructions

Sky FactoryTM. Classic w/ EcoSlim Electrical Instructions (HLG) Installation Instruction includes:

TOF Low Voltage System Review. October 6, 2006 V. Ghazikhanian 1

TEK Brief July Is there a difference in installation requirements between communications cables with and without the LP designation?

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

3 Phase Power Systems - Designed for Canada

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

INSTALLATION GUIDE AND USER MANUAL

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Dimmer Doubler User Manual

FLO Home TM X5 Model. Installation Guide

530 Power. Grounding. Line voltage. Caution. A proper earth ground is required for GC operations.

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Enphase M215 PRODUCTIVE SIMPLE RELIABLE. Enphase Microinverters

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

PV Vault Yielding safety quickly

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Generator Fire Safety: Generator assemblies should be located outside the building.

PDX and PX Retrofit Series

INSTALLATION GUIDE AND USER MANUAL

EVO AT SERIES BATTERY CHARGER

FLO Home TM G5 Model. Installation guide

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

Fuse holders and fuses

AT SERIES EVO BATTERY CHARGER

Electric Vehicle Charging Station

INSTALLATION. **Microprocessor Status LED:

Bulletin 1489 Circuit Breakers. Selection Guide

I n s t a l l a t i o n M a n u a l. f o r T E D

Series L9 UL-489 Miniature Circuit Breakers

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

TELETOM PREINSTALLATION MANUAL

QuickSpecs. HP 480/277 Volt Solutions. Overview

Smart-UPS On-Line Lithium Ion UPS 230V. Single-phase, double conversion online UPS with Li-Ion batteries and advanced management features

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

DATA. Over POWER. DMX RGBW Controllable. 2 Core Data over Power. Data over Power distribution to the fixtures. MaxiPENDANT 64mm Series DMX RGBW IK07

InfraStruXure PDU Power Cable

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

BLACK BOX. Fully assembled, ready-to-use wallmount cabinets. Elite Wallmount Cabinet User s Manual. Customer Support Information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

DUALBRITE Motion Sensing Coach Light

1-Phase Intelligent ATS

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

ATevo SERIES BATTERY CHARGER

RACK SYSTEMS Racks, Rack Enclosures, Cable Managers, Shelves & Accessories

SynergEX Panelboards for Hazardous Locations

Assembly Instructions Retrofitting

6890 Power Related Information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371

Installation and Service Manual for Residential Series EVSE (Electric Vehicle Supply Equipment)

POWER WAVE S350 CE & S500 CE

Liebert PowerSure PSI UPS

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

Mid-Power Remote Unit (MRU) Outdoor Enclosure MIMO Assembly Quick Installation Sheet

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Standard Charging Carts, Intelligent Charging System

PATCHMAX GS3, GS6 and PowerSUM Modular Panels

1489-M Circuit Breakers

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

PDI PowerWave 2 Bus System

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Features MICRO-0.25-I MICRO-0.3-I PRODUCTS PANEL

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part#

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

15 Watt Low-Profile Wall Plug-In, Single Output, 5-24 VDC Switching Power Supply: N.A., Universal Input, ITE, Class II, Energy Star

Features and Benefits

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate.

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

Transcription:

Issue 2, July 2014 Engine 3 Installation General The Redwood engine powers and communicates with Redwood gateways, sensors, and wall switches to provide intelligent lighting control and building intelligence. The engine provides a sophisticated level of control w h i c h significantly reduces energy consumption. Multiple engines can be linked together to power and control hundreds or thousands of fixtures. The engine provides communications and control for all types of lighting including LED, fluorescent, CFL and HID. In the case of LED lighting, the engine also provides centralized AC to DC power conversion. It takes high voltage 200 250 VAC or 277 VAC input power, converts it to low-voltage DC, and distributes the power to all fixtures via Redwood adapters and gateways using Class 2, low-voltage cabling. The engine can be located on a rack or wall mounted in an electrical or telecom closet. Ordering information is listed below: Part No. ENG-3-4834-250 ENG-3-4834-277 PowerCord-NA-120-250 PowerCord-NA-277 PowerCord-AUS-120-250 PowerCord-EU-120-250 PowerCord-UK-120-250 WallMount-Tray-1G TRM-RJ45-18AWG-NA-50 TRM-RJ45-18AWG-NA-8 TRM-RJ45-18AWG-EU-50 TRM-RJ45-18AWG-EU-8 Description Engine 3 model 4834 200 VAC 250 VAC Engine 3 model 4834 277 VAC North America - 8ft (2.44m) North America - 10ft (3m) - NEMA L7-15P - Included with ENG-3-4834-277 Australia - 12ft (3.66m) Europe - 10ft (3m) United Kingdom - 10ft (3m) Engine wall mount kit RJ45 to 18AWG Terminator - North America - 50 Pack RJ45 to 18AWG Terminator - North America - 8 Pack RJ45 to 18AWG Terminator - Europe - 50 Pack RJ45 to 18AWG Terminator - Europe - 8 Pack Redwood Engine 3 Model 4834 For RoHS Inquiries: CommScope Inc. Corke Abbey, Bray 2014 CommScope, Inc. All rights reserved Page 1 of 7 Co. Dublin, Ireland Attn: Legal Department

How to Contact Us To find out more about CommScope products, visit us on the web at / For technical assistance: - Within North and South America, contact your local technical manager or technical support at 1-800-840-0709 (Option 2). Outside North and South America, contact your local technical manager or technical support at +1 510-270-5360 (Option 2). - Technical support for Redwood products is available Monday through Friday from 8 AM to 5 PM (PST), excluding holidays. - An email can also be sent to RedwoodSupport@commscope.com for technical support. Important Notes and Recommendations For installations in Canada, no un-insulated live parts in the output from the Redwood engine shall be readily accessible, as defined by the Canadian Electrical Code (CES). Accessibility shall be determined using the risk of shock accessibility criteria such as use of the finger probe from the CSA standard(s) cited for the category associated with the c-ul Mark. Access to such parts should also be considered when removing panels that do not require the use of tools when removed. Insulated parts, such as wire or cabling with outer insulation or jacket that are certified and carry a sufficient voltage rating (>60V) are permitted to be accessible to contact. If a fixture requires more than one channel for power, use additional wiring (see each fixture s specification for requirements). Note that all additional channels for a 2- or 3-channel fixture must be connected to the same engine. Wiring for an individual fixture cannot be spread across multiple engines. It is recommended that the fixtures in a single space be interleaved across engines. This provides another level of redundancy in the event of an electrical failure affecting an engine, only a portion of the lights in a room would turn off. 18 AWG (1mm) cable installations will be wired as with category cable, except that each 18AWG cable pair will be terminated with a Redwood RJ45-18AWG terminator. These terminators will allow the 18AWG pair to be connected to the RJ45 jack with no other modifications required. Multi-pair 18AWG can be used with multiple Redwood RJ45-18AWG terminators attached. The Redwood engine, director, sensors, gateways and wall switches are designed for commercial use only and are not for household use. Page 2 of 7

860576982 Preparation 1. Determine location for all fixtures and Redwood dimmers. 2. Determine location for all Redwood engines. The engine is a 1.5U rack mountable system and can be installed in a standard server rack using supplied rack-mounting L brackets, or to the wall with a Redwood wall mount kit. 3. Run low-voltage cable from engine location to each fixture location. 4. Run low-voltage cable from the engine location to each Redwood dimmer location. 5. Options for connector preparation: If using the RJ45 connector, it can be wired as T568A (straight through) or T568B (crossover). If using 18 AWG (1mm) wiring to connect to the engine, use a Redwood RJ45 terminator on the 18 AWG wire. 6. Install third-party light fixtures according to vendor s installation instructions. Installation Rack Mount Instructions 1. Attach the two rack mount brackets to each side of the engine using 3 screws provided on each side as shown. 2. With power disconnected, install engine in a standard server rack, using mounting brackets (included). Ensure that air vents are not blocked and that the conditions support the ambient operation temperature of 32 F to 122 F (0 C to 50 C). 3. Connect the cables. Page 3 of 7

Wall Mount Instructions Note: The Redwood engine can be installed flush against a wall using a Redwood wall mount kit as shown above. The wall mount kit contains two pieces, a wall mount tray and a drip pan. Use a ¾" (19mm) plywood backing board (purchased locally). Plywood must be taller and wider than the wall mount tray and wide enough to span the wall studs. 1. Attach the ¾" (19mm) plywood backing board to the wall studs using screws (not provided) that can hold at least 125 lbs (57kg). For a typical situation where the drywall is 5/8" (16mm) thick, a 2" (51mm) or longer drywall screw on each corner of the plywood is recommended. 2. Attach the wall mount tray to the plywood backing board using provided screws. 3. With power disconnected, attach the engine to the wall mount tray using provided screws. Mount the engine with the input power connection facing up and the port connectors facing down. 4. Attach the drip pan to the wall mount tray using the provided screws, and rotate it to the position shown in the installed view of the wall mount assembly. 5. Connect the cables. View of Completed Installation Page 4 of 7

860576982 Cabling 1. Using a conventional method, connect the category cable wiring from the gateway to the punch down side of patch panel. 2. Use an RJ45 jumper cable (or patch cable) to connect the corresponding ports from patch panel. 3. Connect each engine to AC power and turn on AC power using the circuit breaker. Confirm that the engine power light comes on. 4. Connect all engines to the local network via Ethernet ports marked LAN. Note: The category cable should be punched down at the patch panels according to T568A or T568B standards, which are straight through or crossover arrangements. Engine Power Requirements 1. To ensure the engines operate continuously as designed, a dedicated branch circuit for the engines is recommended, preventing other loads on the same circuit from drawing too much current from the branch circuit. Provide the engine with a suitable disconnect in the input power distribution so that AC power is safely removed during servicing. The wiring must meet all NEC, state, and local electrical codes and needs to be installed by a qualified electrician. 2. Redwood engines are available as 200 250 VAC and 277 VAC power input versions. For the 277 VAC version, the engine requires a maximum of 8A of current from the branch circuit to which it is connected when operating at full power. At a minimum, a 10A branch circuit is required for a single engine, given the standard 80% de-rating. The socket-outlet shall be installed near the equipment and shall be easily accessible. AC input: 277 VAC/8A, 50 60Hz Max power consumption: 2,200W Page 5 of 7

For the 200 VAC 250 VAC version, the engine requires a maximum 12A of current from the branch circuit to which it is connected when operating at full power. At minimum, a 15A branch circuit is required for a single engine, given the standard 80% de-rating. AC input: 200 220 VAC/12A, 50 60Hz 230 VAC-250 VAC/10A, 50 60Hz Max power consumption: 2,200W Note: Redwood does not furnish any pigtails, plugs, receptacles, conduit, or flex cable. Engine LED Indicators The engine has a series of LEDs on the front panel to communicate the system s status. These LEDs provide information on the engine s operation and the status of port communication. Power Indicator Status: Power LED Indicator Off Blinking green Solid green Solid amber Engine Status No power is delivered to the engine. The engine is booting. Redwood manager software is not yet running. The engine is on and functioning normally. The engine is experiencing a problem. Call Redwood support. Page 6 of 7

860576982 Port Indicator Status: Each port on the engine has a multi-color LED to communicate status for that port. After a period of inactivity, the LEDs are turned off to save energy. To activate the lights, press the Show Status button on the engine faceplate. Engine Port LED Indicator Status Off Solid green Blinking green Solid amber Port Status No device connection is detected on the port. The engine recognizes the device connection. The engine is upgrading the firmware of a gateway. The engine is in the process of discovering a fixture. Alternately, an error has occurred after discovery. Ethernet Indicator Status: Ethernet Status Indicator Off Blinking green Ethernet Status An Ethernet connection is not detected on this port. The engine recognized the Ethernet connection. Page 7 of 7