INSTALLATION INSTRUCTION W Track Suspension system

Similar documents
INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

The lever must be placed at the lower position, when the track head is intended to be use in a one-circuit track system.

IMPORTANT SAFETY INSTRUCTIONS

GEMINI HOUSING SPECIFICATIONS

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

MOUNTING SYSTEMS SPECIFICATIONS

Alphabet By Ledra Brands

RECESSED TRACK (120V) SPECIFICATIONS

SURFACE TRACK (120/250V) SPECIFICATIONS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

INTEGRID TRACK (120V) SPECIFICATIONS

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

NT-300 Series Single Circuit Track System & Accessories

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

INSTALLATION INSTRUCTIONS

Track Accessories. Single Circuit Track. L Connector T Connector X Connector. Mini Connector Floating Canopy End Feed Kit.

EMERY SKY SUSPENDED LED LUMINAIRE

ASSEMBLY INSTRUCTIONS

Installation Instruction

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

SURFACE CONTROLTrack SPECIFICATIONS

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

Installation Instructions 4 Gravity Enhanced Color Adjustable

HBDBM High Bay Series

4 ft 8 ft 12 ft. straight factory bent. End Cap for Recessed Track Mount for Bruck s GEO track. Offered in white, matte silver or black.

Installation Instructions: Eco Linear High Bay

IMPORTANT SAFEGUARDS

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

Elle Surface Mounting Instructions

High Bay Luminaire Series

Luminaire Support Location Cable Mounting Kit. Non-Power Feed

INSTRUCTION MANUAL SINKER. By HAY

ZIP LIGHT LED LUMINAIRE

Circa Ambient Interior Luminaire

The installation must only be performed by a licensed electrician. Disconnect power before installing the product or servicing it.

QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC)

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

12 INCH WAREHOUSE BARN PENDANT LIGHT

Cetra. Ceiling Power Entry Installation (AEC1, AEC14, or AEC16)

MOONRING 1.5 MOONRING 3

SAVE THESE INSTRUCTIONS!!

HP-2 / HP-6 Direct Installation Instructions Overview

Installation and Maintenance Manual (2014)

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Installation Instructions MX LED Enhanced Color Adjustable

Catalog # Project. Comments. Prepared by. L653 L =12'Nominal Actual length: 140-1/8" [3559mm] W=1 3/8" [3559mm] H =11/16" [17.5mm]

COMPACT BUSWAY 40 & 60 AMP HOUSING

PDI PowerWave 2 Bus System

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Potenza Commercial Pendant Compact Fluorescent, Incandescent, HID Medium, Large

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

Ceiling Star Installation Instructions

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

Installation Guide DO NOT CUT WIRES

General Installation Instructions LED

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Installation Instruction ALG Series LED Area Light Version: 3.1

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Use and Care Guide. Item #

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

Elle Surface Mounting Instructions

Q-04: Replace Brake Shoes/Adjust Brakes

INSTALLATION INSTRUCTION MANUAL

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Product Selection Guide

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

PIL0478 ISSUE 01/ 07/16

Juno Trac-Lites System A complete and customizable track system with an array of features

INSTALLATION & MAINTENANCE MANUAL HBL

LHBC Commercial-Grade High or Low Bay Luminaire

Project. Comments. Prepared by. 20-1/8" [511mm] 44-1/8" [1121mm] 92-1/8" [2340mm] 140-1/8" [3559mm]

Installation Manual Infinity LED Light

SafeLite Installation Steps For a 2 x 2 Light Fixture

ALL W INSTALLATION INSTRUCTIONS

LED SMD CANOPY FLAT FIXTURE

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

PGA Parking Garage Luminaire

SDx Pendant Semi-Direct

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

98PF-P-I Perforated Pendant Indirect. Ordering Guide. Key Features 98-P-I-PF. Fixture Type: Project Name: Quick Find litecontrol.

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

Museum Alkmaar - Alkmaar, Netherlands

LED Utility Wrap Fixture

LSI 20 Series 30A, 120V Surface Busway Components 1

POOL BARON Nicheless Color Changing LED Pool Light

When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

Transcription:

SAFETY INSTRUCTIONS: - Suspension mounting system should be installed by a qualified electrician only. - System is intended for installation in accordance with National Electric Code, local and - Federal code specifications. - To reduce the risk of fire, electrical shock, and injuries to persons: Read all instructions. Turn off power at main switch before installing or modifying the system. Do not install within six inches of any curtain or combustible materials. Do not install less than 5 feet above a floor. Do not install in damp or wet locations. Do not install concealed, or extended through building walls. Do not attempt to energize anything other than a track light fixture. Do not load to more than 20 amps per circuit. Do not exceed 4 feet between mounting points. These systems are suitable for WT/WHT track system only. Save these installation instructions and refer to them when additions or changes to the track configuration are made. OVERALL CONFIGURATION: WMPC WPC WHPC

SUSPENSION MOUNTING OPTIONS: Generally, for any mounting method, do not exceed 4 feet between each mounting point, and do not exceed 6 inches (for 4 feet track or less in length) or 12 inches (for track that is greater than 4 feet) from each end of the single track section. Always use two or more mounting supports for each track length. Mounting system shall be capable of being mounted to flat, sloped or T-bar ceiling structures. Mounting stems shall be capable of being field cut to length. All cable systems are adjustable. All stem systems shall be available in either 6 inch, 12 inch, 24 inch, 36 inch, 48 inch or 96 inch standard lengths. All cable systems shall be available in either 48 inch or 96 inch standard lengths. Space the suspension supports evenly along the track. Recommended: (2) per 4 feet of track, (3) per 8 feet of track, and (4) per12 feet of track, additional suspension supports may be added for heavier loads. FIG.A. INSTALLATION STEPS FOR HANGER CLIP ATTENTION: It is the user s responsibility to ensure the electrical, mechanical and thermal compatibility of the track system and the fittings. The mounting stem should be inserting completely through the hole of the hanger clip.

Fig B: Stem mounting with self-tapping screw or butterfly nut to flat ceiling Fig C: Cable mounting with self-tapping screw or butterfly nut to flat ceiling Fig D: Stem mounting with T-bar clip to T-bar ceiling Fig E: Cable mounting with T-bar clip to T-bar ceiling

Fig F: Stem mounting with self-tapping screw to sloping ceiling Fig G: Cable mounting with self-tapping screw to sloping ceiling POWER FEED WIRE COUPLING: Make sure power is off before wiring. Note the polarity indicator and connect wire to track connector first (Refer to the specifications of WT/WHT track system). Power can be fed down to an End Feed or any other track connector, except the mini coupler (WPC/WHPC). 1. Loosen canopy screws, separate canopy plate and base plate. 2. Remove knock out and route wires through base plate. 3. Connect two live wires (black) from building to black system wires. Connect two neutral wires (white) from building to white system wires. The green wire is the ground wire to be connected with the ceiling ground wire. 4. Secure all connections with wire nuts and tuck excess wire back into the junction box. 5. Secure the base plate to the junction box, with two screws through the slotted holes. 6. Replace the canopy and secure to the base plate. N1 (White) (Green) N2 (White) OR: Used Flexible Conduit Power Feed L1 (Black) L2 (Black) Stem Flexible Conduit Fig H: Power feed wire coupling MOUNTING DEVICES FOR SUSPENSION: Mounting devices for suspension shall be capable of being mounted for mechanical strengthening or power feed, except WMED which is only for power feed and WMPC which is only for mechanical strengthening mounting.

WMIC WMTC WMXC OR: Fig I: Used for stem/cable mechanical mounting Fig J: Used for power feed MAXIMUM LOAD: The drawings show the maximum permissible mechanical load by 2-circuit WT/WHT track for luminaires or other loads in relationship to the fixation or suspension point. It includes both weights of the track systems. Fig K: Maximum mechanical load