Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Similar documents
Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work.

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

Control Parts. AquaLink Touch Replacement Parts 2011 ZODIAC POOL SYSTEMS CATALOG 141. Control Parts

poollux Power plx-pw60 & plx-pw100

IntelliTouch Expansion Center Kit

Installation and User Guide

IntelliTouch Pool and Spa Control System Load Center and Power Center

AquaPure Ei TM Series Replacement Kits

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation and User Guide

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

WARNING. Important Notice

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR

SAFE REPLACEMENT BREAKERS BUILT TO LAST

MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

POOL BARON Nicheless Color Changing LED Pool Light

A B C D E F. Tools Required (supplied by others)

30A SMART ENERGY MANAGEMENT SYSTEM TM

PVM 220 Installation Guide

FLO Home TM G5 Model. Installation guide

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

WF-8500 Series Power Centers

SynergEX Panelboards for Hazardous Locations

The LED Driver Expert

NEC Codes if more current shall supercede this manual

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

Underwater Pool Color-Changing LED Light

Electric Range installation manual

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

MC-351, 421, 431, MC-4311

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N )

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

LOW-VOLTAGE TRANSFORMER INSTALLATION GUIDE. Models: VTR-100SL-SS, VTR-150SL-SS, & VTR-300SL-SS

INSTALLATION M ANUAL

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

WARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES

SURFACE TRACK (120/250V) SPECIFICATIONS

Lumination TM LED Luminaire LUR Series

Terminator TM DL Lighted Power Connection/End Termination Kit INSTALLATION PROCEDURES. For Power Connection or End Termination Applications

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

A WORD ABOUT PROPER GROUNDING

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

5600 Series Power Operator Installation and Instruction Manual

SAVE THESE INSTRUCTIONS

fastfax Rock Solid TM Load Centers General Information

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

Instruction Bulletin. Jockey Pump Controller

PVM 220 Installation Guide

Model Numbers SAVI-NOTE75, SAVI-NOTE150

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

PVM 220 Installation Guide

INSTRUCTIONS. Power Panel. Installation Instructions

Installation and Operation Manual

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

Installation Manual. CS9300 Professional Series Landscape Lighting System

Eylander Electric Inc

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

PDX and PX Retrofit Series

Dry Contact Closure Interface

INTELLIBRITE 5G COLOR POOL AND SPA LIGHTS

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

AquaLuminator Light and Return Water Flow for Above Ground Pools Owner's Manual

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

MODEL WBG WISHBONE BARRIER GATE OPERATOR

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Lighting and Power Distribution Panelboards

Meter Mounting Equipment DTE Energy Area

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Installation Guidelines

FLO Home TM X5 Model. Installation Guide

Transcription:

WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL LISTED Conforms to ANSI/UL STD 508 Certified to CSA STD C22.2 No. 14 3091594 79-15054-00 REV D4 www.srsmith.com Page 1 of 22

The WPC-2 consists of the following parts: Item Qty. Component part No. Description 1 1 - WPC-2 Enclosure 2 1 94-15089-00 WPC-2 Enclosure Door 3 1 37-15000-00 Relay 4 1 41-15004-08 8 Position Terminal Block 5 1 42-15032-00 Timer 6 1 02-15269-00 Load Center Cover Plate 7 2 02-15267-00 WPC-2 Mounting Bracket 8 1 41-15003-00 Grounding Bar 9 1 94-15255-00 WPC Receiver 10 8 10-15086-04 Load Center Cover Plate, Switch Bracket, and Mounting Bracket Screws 11 2 10-15089-06 Terminal Block Mounting Screw 12 2 10-15060-01 Relay Mounting Screw 13 8 10-15089-03 Timer and Receiver Mounting Screws 14 2 A11526 3-Position Toggle Switch 15 1 94-15257-00 WPC Repeater 16 2 10-15089-02 Freeze Device Mounting Screw (Optional equipment) 17 1 20-15013-00 Strain Relief 18 1 02-15270-00 Switch Bracket 19 1 17-15005-00 Latch 20 2 10-15089-01 Latch Mounting Screws Accessory Items: FP 1/2 WE-65 WPC-2/3 ST DL-HUB TC-2 WPC-12V Temperature Freeze Device 65 ft Repeater Cord Extension Kit GFCI Mounting Kit Direct Light Hub Connection Kit Additional Timeclock/Dust Cover 12V Transformer for SR Smith Light Streams LED Products 2 16 15 10 9 10 7 10 18 11 13 4 20 13 5 14 10 12 3 8 17 1 19 10 6 79-15054-00 REV D4 www.srsmith.com Page 2 of 22

SAVE THESE INSTRUCTIONS! IMPORTANT SAFETY INFORMATION Basic safety precautions should be observed when operating the WPC-2 product and other associated equipment. 1. A qualified electrician must install the WPC-2 in accordance to the National and Local Electrical Codes. 2. The WPC-2 must not be less then 5 feet (3 meters in Canada) from inside edge of pool. ONLY USE COPPER CONDUCTORS. 3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors. 4. For the bonding, grounding, installing, and wiring of underwater lights to the WPC-2, refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code. 5. This device should never operate an equipment that could cause property damage, bodily injury, or death should it be activated unexpectedly. 6. Never allow children to operate the WPC-2 unsupervised. ELECTRICAL RATINGS Do not exceed the maximum electrical ratings of the WPC-2. A circuit breaker rated at 20Amps at 120VAC must installed in the breaker panel to connect to the WPC-2 power input. Circuit 1 and Circuit 2 are each rated for use of up to 8Amps @ 120VAC. The Pump Relay is rated at a maximum of 3HP @ 240VAC. SUITABLE LISTED BREAKERS CIRCUIT BREAKER M ANUFACTURER SINGLE DOUBLE TWIN QUAD GFCB FILLER PLATE Thomas & Betts TB TB TBBD TBBQ GFB FP-1C-TB Cutler-Hammer BR BR BRD BRD GFCB BRFP Square D HOM HOM HOM T HOM T HOM -GFI HOM FP Murray MP-T MP-T MH-T MH-T MP-GT LX100FP Siemens/ITE QP QP QT QT QPF QF-3 Challenger C - A-CT - HAGF # FC-1C Westinghouse or Bryant BR - BQ - GFCB FP-1 Crouse Hinds MP - TRIPLEX - MP-GF - GE Regular THOP - - - THOP-GF TQLFP-1 Wiring Information - Copper Conductors Only Terminal Torque* General Wire Size 75 C min. Supply Circuit Breaker Line and Neutral Main Neutral and Max Motor Load (Continuous Duty) General Purpose Branch Circuit Breaker Purpose Branch Circuit Maximum Current Insulation Rating Lugs Ground 120V 240V Rating Capacity AWG AMP LB-IN LB-IN HP HP AMP AMP 14 15 3 5 2 0 1/ 2 1 15 12 12 20 35 20 1 2 20 16 10 30 35 20 11/2 3 30 24 8 50 40 25 2 5 40 32 6 65 45 35 - - 60 44 4 85 45 35 - - - - 3 100 50 - - - - - 2 100/125 50 - - - - - 79-15054-00 REV D4 www.srsmith.com Page 3 of 22

WARNING TURN OFF INCOMING POWER BEFORE SERVICING EQUIPMENT. ALL INSTALLATION AND MAINTENANCE WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL PERSONELL ONLY. VERIFY ALL ELECTRICAL RATINGS BEFORE INSTALLATION IS COMPLETE. LOCATION Install the WPC-2 enclosure using the mounting plates included with each enclosure. The WPC-2 is housed in a Type 3R rainproof enclosure and can be mounted anywhere between the pool equipment and the breaker panel. WIRING INSTRUCTIONS FOLLOW PROPER WIRING PRACTICES IN ACCORDANCE WITH ALL LOCAL REGULATORY REQUIREMENTS. Power Connections: To wire the WPC-2 use insulated COPPER wire only, 12 gauge minimum. Run a ½ to ¾ conduit from the main breaker panel to the WPC-2. Pull appropriate wires from the main breaker panel to the WPC-2 unit. To make power connections remove 3/8 inches of insulation from wire ends. Connect bare wires to the Load Center as illustrated. Tighten terminal screws firmly (20 lb-in minimum). Connect the common to the Neutral bar (tighten to 20 lb-in minimum). Install a 20 Amp circuit breaker and wire to the 120V LINE and the T/C POWER of the terminal block. Wire the Neutral and T/C terminals to the Neutral bar on the Load Center. T/C POWER T/C GROUND LINE - PRIMARY LINE - SECONDARY 79-15054-00 REV D4 www.srsmith.com Page 4 of 22

Power Connection with external GFCI To wire the WPC-2 with the use of a GFCI, punch out the GFCI knockout on the Load Center Cover Plate of the WPC-2. Install a GFCI with appropriate hardware. Using COPPER wire only, 12 gauge minimum, connect the GFCI from the LOAD side to the 120V LINE terminal. Connect the from the LOAD side of the GFCI to the terminal. Connect the GROUND of the GFCI to the EQUIP. GND. bar. Wire the HOT from the GFCI s LINE side to the 20Amp circuit breaker. Connect the from the GFCI s LINE side to the Neutral bar on the Load Center NOTE: DO NOT connect the T/C POWER and T/C to the GFCI s LOAD side. T/C POWER T/C HOT LINE SIDE HOT LOAD SIDE LOAD SIDE GFCI LINE SIDE GROUND INSTALL GFCI USING APPROPRIATE HARDWARE 79-15054-00 REV D4 www.srsmith.com Page 5 of 22

Power Connection with external GFCI To wire the WPC-2 with the use of a GFCI, punch out the GFCI knockout on the side of the WPC-2 enclosure. Install an outdoor rated GFCI. Using COPPER wire only, 12 gauge minimum, connect the GFCI from the LOAD side to the 120V LINE terminal. Connect the from the LOAD side of the GFCI to the terminal. Connect the GROUND of the GFCI to the EQUIP. GND. bar. Wire the HOT from the GFCI s LINE side to the 20Amp circuit breaker. Connect the from the GFCI s LINE side to the Neutral bar on the Load Center. NOTE: DO NOT connect the T/C POWER and T/C to the GFCI s LOAD side. T/C POWER T/C HOT LOAD SIDE LOAD SIDE GFCI LINE SIDE HOT LINE SIDE GROUND 79-15054-00 REV D4 www.srsmith.com Page 6 of 22

Hooking up Lights to Circuit 1 and Circuit 2 To connect a lighting product to the Circuit 1 and Circuit 2 switch, pull wires from the products to the WPC-2 through conduits connected to the bottom of the WPC-2. As illustrated, connect lights that will be operated by the Circuit 1 Switch to the Circuit 1 terminal. Connect the Neutral to the Terminal Block marked Neutral. Connect the Ground to the Equip. GND. bar. Repeat for Circuit 2. Do not exceed 8Amps per circuit. LOAD GROUND LOAD GROUND To Lights for use on Circuit 1 To Lights for use on Circuit 2 If this product is used to connect underwater lights directly, refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. 79-15054-00 REV D4 www.srsmith.com Page 7 of 22

Connecting Jazz, Jazz-Spa, System 6004, and System 6004-AS* For proper operation of these products both Circuit 1 and Circuit 2 must be wired so that the power is controlled through Circuit 1 and the color wheel functions are controlled through Circuit 2. Follow each products installation manual for proper installation. Run appropriately rated wires from the light to the WPC-1 no less than 12 Gauge COPPER wires. Connect the Power to the Circuit 1 terminal at one end and to the BLACK wire on the light. Connect the neutral to the terminal in the WPC-1 and to the WHITE wire on the light. Connect the grounding cable to the EQUIP. GND. and on the other end to the GREEN cable. Finally, for synchronization operation, connect the C/W CONTROL cable to the Circuit 2 terminal and on the other end to the RED wire on the light. You may connect up to 8Amps of supply current to Circuit 1 or Circuit 2. POWER C/W CONTROL GROUND If this product is used to connect underwater lights directly, refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. * Or other two button Power/Color system, ie. Pentair, Supervision, Fiberworks 79-15054-00 REV D4 www.srsmith.com Page 8 of 22

CONNECTING A 240VAC PUMP Connect the 240VAC pump to the relay as illustrated. Connect a 240VAC Circuit Breaker to the Load Center. Wire the Relay from the 240VAC Circuit Breaker as illustrated. 240V Circuit Breaker 240VAC Pump 79-15054-00 REV D4 www.srsmith.com Page 9 of 22

CONNECTING A 120VAC PUMP To wire a 120VAC pump to the Relay, connect the LOAD wire from the pump (as illustrated) to the Relay and a 120VAC power from an appropriate circuit breaker using no less then a 10 gauge COPPER wire. Connect the from the pump directly to the bar at the breaker panel (as illustrated). Alternately, you may connect the from the pump to the Relay and from the Relay to the bar. 120VAC Neutral 79-15054-00 REV D4 www.srsmith.com Page 10 of 22

FOR TEMPERATURE FREEZE PROTECT SWITCH OPTION FOR USE ON WPC-2 AUXILIARY RELAY KIT 79-15054-00 REV D4 www.srsmith.com Page 11 of 22

Repeater Mounting The WPC-2 is equipped with a signal repeater that can be mounted up to 10 feet from the WPC-2 unit. This repeater receives signals from the wireless remote and sends that signal to the WPC-2 via the 10 foot cable. Establish a location for the Repeater that is in line of sight from where the wireless remote will be used most frequently and that is no more then 75 feet from furthest where the remote will be used. NOTE: If extension is needed, use SR Smith part number 94-15098-00 and follow installation instructions supplied with the Repeater Extension. To mount the Repeater, carefully insert a small flathead screwdriver into groove between the Dome and Base approximately where the locking dimples are located. Pry the Dome out of the locking dimples. Then carefully insert the small flathead screwdriver into the groove between the Dome and the Base in an adjacent locking dimple and pry the Dome out. Then separate the Dome from the Base by hand. Using the supplied self-drilling screws, locate a suitable mounting surface and screw the base to this surface. Note that the marking TOP must be in the 12 o clock position and the wire slit must be in the 6 o clock position. Do not over tighten the screws as it may damage the Repeater base. Realign the Repeater Dome to the Base and ensure that the wire is exiting the base through the slit and the Locking Dimples are aligned with the locking holes. Apply enough pressure so that the Dome snaps into the base. NOTE: Do not stuff the remainder of the Repeater wire into the WPC unit. Flathead Screwdriver Repeater 10 feet Dome/Base groove Locking Dimple Mounting Screws Orientation Marker Mounting Holes Repeater Dome Base Slit for Repeater Wire Repeater Base 79-15054-00 REV D4 www.srsmith.com Page 12 of 22

OPERATING INSTRUCTIONS WPC-2 TOGGLE SWITCH OPERATION The WPC-2 receiver box houses two toggle switches. For operation with the wireless transmitter, the switches need to be in the DOWN or REMOTE position. To manually turn ON the devices connected to either Circuit 1 or Circuit 2, flip the toggle switches UP or to the ON position. When a circuit is in the ON position, the Wireless Remote will not be able to turn OFF the respective circuit. To turn OFF the devices manually, flip the respective toggle switch to the MIDDLE or OFF position. NOTE: In the OFF position, the wireless remote operation will be bypassed. To re-enable the wireless remote operation, flip the toggle switch back to the BOTTOM or REMOTE position. NOTE: If the units turn ON when the switch is returned to the REMOTE position, simply use the wireless remote to turn OFF the units if desired. NOTE: Circuit 1 is in the ON position and Circuit 2 is in the REMOTE position WIRELESS REMOTE OPERATION NOTE: The toggle switches on the WPC-2 must be set to REMOTE for wireless operation. The POWER ON/OFF buttons control the individual circuits independently. With each push of the button, the WPC-2 toggles the individual circuits from ON to OFF and vice versa. For Synchronization operation, simply push the SYNC ON/OFF button. NOTE: If all circuits are off when the SYNC ON/OFF button is pressed, all circuits will be turned to ON. If any one of the circuits are in the ON state by the wireless remote, then when the SYNC ON/OFF button is pressed all circuits will be turned OFF and the SYNC ON/OFF must be pressed to turn all circuits on simultaneously. Circuit 1 control For Synchronization of Circuit 1 and Circuit 2 Circuit 2 control 79-15054-00 REV D4 www.srsmith.com Page 13 of 22

TIMER OPERATION Set time to current time. In the example below, the current time is set for 9:00pm. NOTE: Only turn the Timer dial clockwise or the timer will be damaged. Once the time has been set to the current time, set the hours of the Pump operation by snapping the timer tabs inwards towards the center. NOTE: Each tab represents 15 minutes of operation and tabs set inwards towards the center is for OFF operations and ON when the tabs are set outwards as illustrated. In the example below, the Pump will be off from 12:00pm to 11:45pm. Once the time and time of operation has been set, ensure that the Timer function switch is set to Auto for timer control of the Pump as illustrated below. To turn off timers automatic functions, set the Timer function switch to OFF. To manually turn on the Pump, set the Timer function switch to the ON position. NOTE: When in the ON position, the Pump will continue to run until the Timer function switch is set to Auto where the tabs at the Set Point is in the OFF position or if the Timer function switch is rotated to the OFF position. Timer Function Switch Position UP MIDDLE DOWN Timer tabs set to ON position Timer tabs set to OFF position Timer dial rotation direction indicator Current time and Timer function switch set point PM hours AM hours Timer function switch Timer dial 79-15054-00 REV D4 www.srsmith.com Page 14 of 22

CODE ADJUSTMENTS If it is necessary to change the transmission code on the WPC-2 an adjustment to the receiver AND the transmitter DIP switches must be performed. RECEIVER DIP SWITCHES Turn OFF power to the WPC-2 from the circuit breaker on the Load Center or from Main Power. Open the enclosure door. Unscrew and remove the Load Center Cover Plate. Place the Cover Bracket in a safe location. Unscrew and remover the Switch Bracket. Disconnect the Molex connector that connects the Switch Bracket controls to the receiver unit and set the Switch Bracket in a safe location where it will not be bent, scratched, or impact forces applied to the components or the face plate itself. Unscrew the four (4) screws holding the receiver to the base of the WPC-2 control box. Unscrew the four (4) screws located on the back of the receiver to release the cover. NOTE: Take notice of how the wires enter and exit the receiver. Remove the cover and look on the PCB to locate the DIP switch as illustrated. TRANSMITTER DIP SWITCHES Remove all screws from rear of remote. Separate the bottom cover from the top cover. DIP SWITCH ADJUSTMENT The four DIP switches have an ON and an OFF position. Changing just one DIP switch will change the code. MAKE SURE BOTH THE RECEIVER AND TRANSMITTER HAVE THE SAME DIP SWITCH SETTINGS. Molex Connector Receiver Mounting Holes Switch Bracket Rear screws DIP Switch Load Center Cover Plate Mounting Screws DIP switch Receiver screws 79-15054-00 REV D4 www.srsmith.com Page 15 of 22

Note: Sample shown is of Channel 9 DIP SWITCH 1 2 3 4 Channel 1 OFF OFF OFF OFF Channel 2 ON OFF OFF OFF Channel 3 OFF ON OFF OFF Channel 4 ON ON OFF OFF Channel 5 OFF OFF ON OFF Channel 6 ON OFF ON OFF Channel 7 OFF ON ON OFF Channel 8 ON ON ON OFF Channel 9 OFF OFF OFF ON Channel 10 ON OFF OFF ON Channel 11 OFF ON OFF ON Channel 12 ON ON OFF ON Channel 13 OFF OFF ON ON Channel 14 ON OFF ON ON Channel 15 OFF ON ON ON Channel 16 ON ON ON ON CHANNEL 1 5 9 13 2 6 10 14 3 7 11 15 4 8 12 16 DIP Switch 79-15054-00 REV D4 www.srsmith.com Page 16 of 22

WPC2-2X1X-X Two Speed Pump with Time Clock Bypass on Circuit 2 Wiring instructions Hooking up Lights to Circuit 1 Note: Series WPC2-2X1X-X uses Circuit 2 for Low Speed and Timer Override function for High Speed operation. To connect a lighting product to the Circuit 1 switch, pull wires from the products to the WPC-2 through conduits connected to the bottom of the WPC-2. As illustrated, connect lights that will be operated by the Circuit 1 Switch to the Circuit 1 terminal. Connect the Neutral to the Terminal Block marked Neutral. Connect the Ground to the Equip. GND. bar. Do not exceed 7Amps per circuit. Hooking up the 2 Speed Pump. As illustrated, connect the Low Speed wire to the Low Speed Load terminal on the terminal block. Connect the High Sped wire to the High Speed Load terminal on the terminal block. Connect the 120V Primary from the 240V Circuit Breaker to the 120V PRI INPUT terminal. Directly connect the 120V Secondary from the 240V Circuit Breaker to the 2 Speed Pump. To Lights for use on Circuit 1 LOAD GROUND LOW SPEED LOAD HIGH SPEED LOAD 120VAC SEC INPUT 120VAC PRI INPUT NOTE: Pump Breaker MUST be turned OFF before servicing as 2 nd leg of 240V circuit is HOT at all time! If this product is used to connect underwater lights directly, refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. Note: Circuit 2 is pre-wired. There is no connections or external wiring. 79-15054-00 REV D4 www.srsmith.com Page 17 of 22

WPC2-2XXX-X Wiring instructions Two Speed Pump Hooking up a 2 Speed Pump to the WPC2-2XXX-X. Note: Series WPC2-2XXX-X runs the 2 Speed Pump on low speed continuously until Timer activates High Speed mode. As illustrated, connect the Low Speed wire to the Low Speed Load terminal on the terminal block. Connect the High Sped wire to the High Speed Load terminal on the terminal block. Connect the 120V Primary from the 240V Circuit Breaker to the 120V PRI INPUT terminal. Directly connect the 120V Secondary from the Circuit Breaker to the 2 Speed Pump. NOTE: The Secondary 120V must be directly connected to the pump for 240V operation. NOTE: Pump Breaker MUST be turned OFF before servicing as 2 nd leg of 240V circuit is HOT at all time! If this product is used to connect underwater lights directly, refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. 120VAC SEC INPUT LOW SPEED LOAD HIGH SPEED LOAD 120VAC PRI INPUT Note: Circuit 2 is pre-wired. There is no connections or external wiring. For Light wiring instructions, please see pages 7 and 8. 79-15054-00 REV D4 www.srsmith.com Page 18 of 22

WPC2-XX1X-X Single Speed Pump with Time Clock Bypass on Circuit 2 Wiring instructions Hooking up Lights to Circuit 1 Note: Series WPC2-XX1X-X uses Circuit 2 for Pump Override function. To connect a lighting product to the Circuit 1 switch, pull wires from the products to the WPC-2 through conduits connected to the bottom of the WPC-2. As illustrated, connect lights that will be operated by the Circuit 1 Switch to the Circuit 1 terminal. Connect the Neutral to the Terminal Block marke Neutral. Connect the Ground to the Equip. GND. bar. Do not exceed 7Amps per circuit. LOAD GROUND To Lights for use on Circuit 1 If this product is used to connect underwater lights directly, refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. Note: Circuit 2 is pre-wired. There is no connections or external wiring. For Pump wiring directions, please see pages 9 and 10. 79-15054-00 REV D4 www.srsmith.com Page 19 of 22

WPC2-XX2X-X Single Speed Pump with Time Clock Bypass Wiring instructions and JVA Valve Control on Circuit 2 Hooking up Lights to Circuit 1 Note: Series WPC2-XX2X-X uses Circuit 2 for Pump Override function and JVA activation. To connect a lighting product to the Circuit 1 switch, pull wires from the products to the WPC-2 through conduits connected to the bottom of the WPC-2. As illustrated, connect lights that will be operated by the Circuit 1 Switch to the Circuit 1 terminal. Connect the Neutral to the Terminal Block marked Neutral. Connect the Ground to the Equip. GND. bar. Do not exceed 7Amps per circuit. 24V Valve Wiring. To connect a 24V Valve, follow diagram as shown. Connect one leg of the 24V common to the 24V to Valve terminal. Connect the Close wire to the NC Load terminal and the Open wire to the NO Load terminal. You must also connect the second 24V leg directly to the valve for 24V operation. 24V to Valve NC Load to Valve NO Load to Valve LOAD GROUND If this product is used to connect underwater lights directly, refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. To Lights for use on Circuit 1 Note: Circuit 2 is pre-wired. There is no connections or external wiring. For Pump wiring directions, please see pages 9 and 10. 79-15054-00 REV D4 www.srsmith.com Page 20 of 22

WPC2-XX3X-X Booster Pump on Circuit 2 Wiring instructions Hooking up Lights to Circuit 1 Note: WPC2-XX3X-X uses Circuit 2 for Booster Pump operation. To connect a lighting product to the Circuit 1 switch, pull wires from the products to the WPC-2 through conduits connected to the bottom of the WPC-2. As illustrated, connect lights that will be operated by the Circuit 1 Switch to the Circuit 1 terminal. Connect the Neutral to the Terminal Block marked Neutral. Connect the Ground to the Equip. GND. bar. Do not exceed 7Amps per circuit. Hooking up the Filter Pump and the Booster Pump. Connect the 240VAC Filter Pump to the relay as illustrated. Connect a 240VAC Circuit Breaker to the Load Center. Wire the Relay from the 240VAC Circuit Breaker as illustrated. Repeat for the Booster Pump. To Lights for use on Circuit 1 LOAD GROUND 240V Circuit Breaker 240V Booster Pump 240V Filter Pump If this product is used to connect underwater lights directly, refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. Note: Circuit 2 is pre-wired. There is no connections or external wiring. 79-15054-00 REV D4 www.srsmith.com Page 21 of 22

WPC2-XX3X-2 Wiring instructions Booster Pump on Circuit 2 with Auxiliary Time Clock and Relay Hooking up Lights to Circuit 1 Note: WPC2-XX3X-2 uses Circuit 2 for Booster Pump operation. To connect a lighting product to the Circuit 1 switch, pull wires from the products to the WPC-2 through conduits connected to the bottom of the WPC-2. As illustrated, connect lights that will be operated by the Circuit 1 Switch to the Circuit 1 terminal. Connect the Neutral to the Terminal Block marked Neutral. Connect the Ground to the Equip. GND. bar. Do not exceed 7Amps per circuit. Hooking up the Filter Pump, Booster Pump and Pool Cleaner. Connect the 240VAC Filter Pump to the relay as illustrated. Connect a 240VAC Circuit Breaker to the Load Center. Wire the Relay from the 240VAC Circuit Breaker as illustrated. Repeat for the Booster Pump and the Pool Cleaner. To Lights for use on Circuit 1 LOAD GROUND 240V Circuit Breaker 240V Pool Cleaner 240V Filter Pump 240V Booster Pump If this product is used to connect underwater lights directly, refer to 1999 NEC 680-21(b), 2002 NEC 680-24(b) or CEC 68-060, 062 and 066 for details. Note: Circuit 2 is pre-wired. There is no connections or external wiring. 79-15054-00 REV D4 www.srsmith.com Page 22 of 22