Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

Similar documents
FC-27W 7 dome housing. Installation Instructions

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

INSTALLATION GUIDE. S-Type COOLDOME ENCLOSURE

INSTALLATION GUIDE KT-CDR2 & KT-CDR3. For COOLDOME ENCLOSURE SERIES

Transmission Guardian

Installation Power Management Unit Battery Cables and Battery Harness

PVI 60KW, PVI 82KW, PVI 95KW

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

INSTALLATION GUIDE COOLDOME ENCLOSURE SERIES

II DISTRIBUTION & SUBSTATION TYPE C

DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

END USER TERMS OF USE

Thermaltake Warranty / Support Information

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Installation Guide. Marine Filter SURT023M SURT024M

Broadband PowerShield. CP27U Models. User Manual

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Manual Transfer Switch

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Cabling for power, control, and video must be run to the installation site before the mount is installed.

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

MaxLite LED Linear HighBay Fixtures

DC to AC Power Inverters

DC to AC Power Inverters

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

PSX-240 Enclosed Autotransformer Installation Manual

INSTALLATION/OWNERS MANUAL

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Installation Instructions

SIDE-WIND, A-FRAME TRAILER JACK. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Installation Instructions

CTFRP Series Power Supplies

Installation Instructions

Installation Instructions

Installation Instructions

BP1204 INSTALLATION/OWNER'S MANUAL

Spare Parts, Instruction and Maintenance Manual for SPANCO Model 301 Jib Cranes

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

Installation Instructions

ADI-125/750 ADI-125/1500 ADI-125/2500

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

XP88 & XP89 Series Quick Start

Installation Instructions

OWNERS MANUAL JANUARY 2007 ISO

MIL-24/2600Q MIL-24/3200DQ

Cordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

Installation Instructions

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Installation Instructions

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Installation Instructions

ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. User s Manual. Model ACS

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

INSTALLATION/OWNERS MANUAL XNBP BANDPASS SERIES. Bandpass Enclosures

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

Rig Master Power by Mobile Thermo Systems Inc.

Air Curtain. Installation, Operating and Maintenance Instructions

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

PUSH BUTTON KEY CABINET

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Installation Manual & Warranty

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Users Guide for Ac-sync

Installation Instructions

CLEAN POWER TM CPS Series Operator s Manual

INSTALLATION INSTRUCTION & OWNER S MANUAL

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

DCCB. Installation Guide. Sine Wave Plus DC Conduit Box (DCCB)

MaxLite StaxMax LED Flood Lights

LU27 Series Quick Start

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

MODEL TC400 TIRE CART. Installation, Operation & Repair Parts Information REV P/N:

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

OWNERS MANUAL JANUARY 2007 ISO

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

DC Distribution Panel User Guide # S

StormPro BA Series Sump Pump

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Owner s Manual. OutCast 1.2. The Ultimate Outdoor Speaker System

DSP led gaming monitor USER MANUAL

ActuLink ABS Module - ABS-MOD-400

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

Nature s Generator Power Panel

Transcription:

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS User Manual Revision June 2008

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply LIMITED WARRANTY FOR DOTWORKZ SYSTEMS INC. PRODUCTS DOTWORKZ SYSTEMS INC. warrants this Product to be free from defects in material or workmanship, as follows: PRODUCT CATEGORY PARTS LABOR All Enclosures and Electronics One (1) Year One (1) Year Power Supplies One (1) Year One (1) Year Accessory Brackets One (1) Year One (1) Year During the labor warranty period, to repair the Product, Purchaser will either return the defective product; freight prepaid, or deliver it to Dotworkz Systems Inc. San Diego, CA. The Product to be repaired is to be returned in either its original carton or a similar package affording an equal degree of protection with a RMA # (Return Materials Authorization number) displayed on the outer box or packing slip. To obtain a RMA# you must contact our Technical Support Team at 866-575-4689, Dotworkz Systems will return the repaired Product freight prepaid to Purchaser, Dotworkz Systems is not obligated to provide Purchaser with a substitute unit during the warranty period or at any time. After the applicable warranty period, Purchaser must pay all labor and/or parts charges, The limited warranty stated in these product instructions is subject to all of the following terms and conditions: 1. NOTIFICATION OF CLAIMS: WARRANTY SERVICE: If Purchaser believes that the Product is defective in material or workmanship, then written notice with an explanation of the claim shall be given promptly by Purchaser to Dotworkz Systems but all claims for warranty service must be made within the warranty period. If after investigation Dotworkz Systems determines that the reported problem was not covered by the warranty, Purchaser shall pay Dotworkz Systems for the cost of investigating the problem at its then prevailing per incident billable rate. No repair or replacement of any Product or part thereof shall extend the warranty period as to the entire Product. The specific warranty on the repaired part only shall be in effect for a period of ninety (90) days following the repair or replacement of that part or the remaining period of the Product parts warranty, whichever is greater 2. EXCLUSIVE REMEDY: ACCEPTANCE: Purchaser's exclusive remedy and Dotworkz System s sole obligation is to supply (or pay for) all labor necessary to repair any Product found to be defective within the warranty period and to supply, at no extra charge, new or rebuilt replacements for defective parts 3. EXCEPTIONS TO LIMITED WARRANTY: Dotworkz Systems shall have no liability or obligation to Purchaser with respect to any Product requiring service during the warranty period which is subjected to any of the following: abuse, improper use: negligence, accident, lightning damage or other acts of God (i.e., hurricanes, earthquakes), modification, failure of the end-user to follow the directions outlined in the product instructions, failure of the end-user to follow the maintenance procedures recommended by the International Security Industry Organization, written in product instructions, or recommended in the service manual for the Product. Furthermore, Dotworkz Systems shall have no liability where a schedule is specified for regular replacement or maintenance or cleaning of certain parts (based on usage) and the end-user has failed to follow such schedule; attempted repair by non-qualified personnel; operation of the Product outside of the published environmental and electrical parameters, or if such Product's original identification (trademark, serial number) markings have been defaced, altered, or removed. Dotworkz Systems excludes from warranty coverage Products sold AS IS and/or WITH ALL FAULTS and excludes used Products which have not been sold by Dotworkz Systems to the Purchaser. All software and accompanying documentation furnished with, or as part of the Product is furnished "AS IS" (i.e., without any warranty of any kind), except where expressly provided otherwise in any documentation or license agreement furnished with the Product. 4. PROOF OF PURCHASE: The purchaser s dated bill of sale must be retained as evidence of the date of purchase and to establish warranty eligibility. DISCLAIMER OF WARRANTY EXCEPT FOR THE FOREGOING WARRANTIES, DOTWORKZ SYSTEMS HEREBY DISCLAIMS AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUI NOT LIMITED TO ANY AND/OR ALL IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND/OR ANY WARRANTY WITH REGARD TO ANY CLAIM OF 1NFRINGEMENTTHAT MAY BE PROVIDED IN SECTION 2-312(3) OF THE UNIFORM COMMERCIAL CODE AND/OR IN ANY OTHER COMPARABLE STATE STATUTE. DOTWORKZ SYSTEMS HEREBY DISCLAIMS ANY REPRESENTATIONS OR WARRANTY THAT THE PRODUCT IS COMPATIBLE WITH ANY COMBINATION OF NON-V1DEOLARM PRODUCTS OR NON-DOTWORKZ SYSTEMS RECOMMENDED PRODUCTS PURCHASER CHOOSES TO CONNECT TO PRODUCT. LIMITATION OF LIABILITY THE LIABILITY OF DOTWORKZ SYSTEMS, IF ANY, AND PURCHASER'S SOLE AND EXCLUSIVE REMEDY FOR DAMAGES FOR ANY CLAIM OF ANY KIND WHATSOEVER, REGARDLESS OFTHF I FGAI THEORY AND WHFTHFR ARISING IN TORT DP CONTRACT. SHALL NOT RE GREATER THAN THE ACTUAL PURCHASE PRICE Of THE PRODUCT WITH RESPECT TO WHICH SUCH CLAIM IS MADE. IN NO EVENT SHALL DOTWORKZ SYSTEMS BE LIABLE TO PURCHASER FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION, REIMBURSEMENT OR DAMAGES ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS OR FOR ANY OTHER REASON WHATSOEVER. IMPORTANT SAFEGUARDS 1 Read Instructions - All the safety and operating instructions should be read before the unit is operated. 2 Retain Instructions -The safety and operating instructions should be retained for future reference. 3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to. 4. Follow Instructions -All operating & user instructions should be followed. 5. Electrical Connections - Only a qualified electrician should make electrical connections. 6. Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards 7. Cable Runs - All cable runs must be within permissible distance 8. Mounting -This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight of the unit. Accordingly: a. Installation should be made by a qualified installer. b. Installation should be in compliance with local codes c. Care should be exercised to select suitable hardware to install the unit, taking into account both the composition of the mounting surface and the weight of the unit. Be sure to periodically examine the unit and the supporting structure to make sure that the integrity of the installation is intact. Failure to comply with the foregoing could result in the unit separating from the support structure and falling, with resultant damages or injury to anyone or anything struck by the failing unit, CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT EXPOSE COMPONENTS TO WATER OR MOISTURE The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of non-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance SERVICE If the unit ever needs repair service, customer should contact Dotworkz Systems +1 (619) 224-LIVE (5483) for return authorization & shipping instructions UNPACKING Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper. Be sure to save 1.The shipping carton and packaging material. They are the safest material in which to make future shipments of the equipment. 2. These Installation and Operating Instructions.

PRODUCT INSTALLATION PRECAUTIONS WARNINGS ADDITIONAL INFORMATION (RETAIN THIS DOCUMENT) For technical questions or product returns call: Dotworkz Customer Service (866-575-4689) Assistance Available Monday thru Friday 8:00 AM to 5:00 PM (PST) A technician will contact you as soon as possible. Read and familiarize yourself with all instructions prior to installing enclosure to avoid damage to product, or harm to installer. Fully understand all wiring requirements before installation. The External Nut on All electrical wire feed Glands must be tightened to create a weather tight seal prior to putting enclosure in service. Failure to create this seal may result in water incursion into enclosure. This may lead to electrical shock, product failure and damage to electrical systems installed within enclosure, including but not limited to damage to camera, heater and blower circuitry, cooling circuitry and other systems installed in unit. All Latches on hinged lid must be secured to create seal on enclosure prior to putting enclosure into service. Failure to create this seal may result in water incursion into enclosure. This may lead to electrical shock, failure and damage to electrical systems installed within enclosure, including but not limited to damage to Power Supply circuitry and other systems installed in unit. Do not over tighten any Screws, Seals, or other fasteners on this unit. Failure to heed this warning may cause damage or failure to the enclosure.

Installation Guidelines for CoolDome Power Supply Enclosure: Never apply high voltage power directly to the CoolDome Enclosure Inputs. The S-250-12 is pictured below on the side of its Terminal Block. S-250 Power Supply The internal circuitry of the D2 & Static CoolDome Enclosures were engineered for 12 VDC input ONLY. (24 VDC input Models available by special order.) Each Cool Dome is supplied with an external high voltage power supply, the Dotworkz/ MeanWell S-250-12 Power supply, which converts the power to a low voltage 12 vdc output. This allows you to use high voltage to Externally convert to low voltage power to send to the CoolDome. It is a highly durable, heat tolerant, A/C to D/C Power converter. Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply, Product Code: NM-CDPS, was designed to allow this power supply to be mounted in outdoor locations. It comes integrated with the S-250 power supply & has a thermally controlled exhaust fan. Customer must Supply wiring for A/C input, and DC output. To reduce the effects of Low Voltage Line Drop, Please keep Low Voltage DC runs from power supply to the CoolDome as short as possible Please be especially attentive to wire using the Proper Polarity, so as not to damage the internal components, or damage your camera within. High Voltage A/C Typical Conventions, single phase: Color Symbol Description Black L Line Conductor, aka: Hot wire White N Neutral Conductor Green G, Ground Wire, Chassis Ground Low Voltage conventions, D/C, direct current: Color Symbol Description Red V+ Positive conductor Black V- Negative conductor

AC Power Hook- Up The input to the provided external power supply follows standard A/C wiring conventions, and is to be mounted nearby indoors, or outdoors in a weather rated enclosure.. It can be powered by single phase 110 VAC, or 220 VAC. It must be manually set to the correct input voltage range (110 VAC or 220 VAC), by moving and setting the slide switch on the side of the power supply, before powering up. A Nema rated outdoor power supply Enclosure (NM-CDPS). The output of the S-250-12 external power supply, can be adjusted up and down 10%. It is recommended to keep the voltage at the enclosure adjusted to at least 11.5 vdc, but no more than 13.0 vdc. By running the enclosure higher than 13.0 vdc may cause premature component failure. It is best to check and tune the voltage at the CoolDome with a voltage meter at the time of installation, and use the adjustment screw, located on the S-250-12, to the right side of the terminal screws, to raise or lower the output voltage. For all outdoor wiring, always use an outdoor rated wiring, or wiring in weather rated conduit, out from power supply, into the Cool Dome. Follow all local and applicable wiring and safety standards. Low Voltage Wiring Hook Up Please keep D/C wire runs short, to reduce low voltage line drop. Also, the suggested wiring gauge table is provided to further prevent low voltage line drop, and to guide you in selecting the proper wire gauge for the dc run from the power supply to the cool dome. The two ways to reduce this voltage line drop, is keep the DC power run as short as possible. The second way is to use as heavy gauge wire as feasible, to reduce low voltage resistance, and thus voltage drop, in the wire conductors. Note that the voltage drop will only show on a long wire run under near fully loaded conditions. Unloaded voltage measurement will show very little voltage drop at enclosure. Only when the CoolDomes thermostat engages, and cooling unit is running, will the wiring be loaded to show full line drop across wiring run. (See Table 2 on next page for wire AWG guidelines for wire run lengths). Inside the Static CoolDome, we have provided a convenient white Screw cage clamp style terminal blocks to wire the 12 vdc low voltage wire run (customer supplied wiring), from the external power supply, to connect the power to the static CoolDome. Remember low voltage wiring color coding convention: positive (V+) +12 VDC (red), and the 12 vdc Negative (V-) (black) terminal. Please strip the insulation off the last 3/8 of the wires and fasten wiring securely to terminal, using a small blade screwdriver to tighten the caging mechanism on the terminal blocks. See CoolDome User Manual for Line Drop Tables, or visit website line drop website as follows. A non-affiliated link that is helpful for line drop calculation is below. This is handy to quickly calculate wire drops on low voltage circuits. http://nooutage.com/vdrop.htm Dotworkz Customer Service For technical inquiries, Product Support, or product returns, Contact: Online customer service (8:00 AM to 5:00 PM, PST): Support@dotworkz.com View latest Manuals and Support Materials from our Website: http://www.dotworkz.com/customer_service/manuals_datasheets.asp Or, by phone in the USA, (7:30 AM to 4:30 PM, PST): Dotworkz Customer Service Line: 1-866-575-4689 Phones outside USA, please call: +1-619-224-5483

Dimensions & Specifications Overall Inside Mounting Hole Enclosure H x W x D A x B x C E x F J K L M N Dia. Weight 11.62 x 9.41 x 4.25 9.73 x 7.73 x 3.98 10.75 x 6 3.5 8.25 6.25 0.25 11.35 0.31 7.5 lbs. (295 x 239 x 108) (247 x 196 x 101) (273 x 152) (89) (209) (159) (6) (288) (8)