Blast Valves for HVAC Ducting

Similar documents
Concrete blast door NORFO TBS

Electromotoric Actuators

Blast Protection Damper

SECTION AXIAL HVAC FANS

The Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

PROJ. NO SECTION HYDRONIC PUMPS

SECTION CENTRIFUGAL HVAC FANS

S200-P Passport Series Fire Pump Service Parts List

REBAR CONNECTION SYSTEM

Instruction Manual (B)

Oil Pan Replacement Buick Regal

Octave Water Meter Installation Manual

Actuators for Fire Protection Dampers

(This Instruction Manual)

SINGLE DUCT TERMINAL UNITS

Crankshaft Position Sensor

CURTAIN TYPE FIRE DAMPER

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Instruction Manual (B)

Page 1 - Gearbox & Bearing Housing. Page 2 - Wet End - Rotor Case & Rotors (Part 1) Page 3 - Wet End - Rotor Case & Rotors (Part 2)

Surge arrester POLIM-H..SD

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Non Return Damper, Type RK-E20

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

A Member of the. Integrated Metering Technologies

CERTIFICATE OF APPROVAL No CF 249. Yung Chi Paint & Varnish Mfg. Co., Ltd

Surge arrester POLIM-H.. ND

Insertion magnetic inductive flowmeter

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

ACETARC ACETARC FOUNDRY LADLES ENGINEERING. General design specification

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Operator Instructions for Tension Links

Pan and Tilt Head CDD2416-T

VALVES WITH NA ELECTRIC ACTUATOR

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

CERTIFICATE OF APPROVAL No CF 557 JOTUN PAINTS (EUROPE) LIMITED

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

EXHAUSTEX The EXHAUSTEX 2000 is shipped fully assembled except for the Legs, Over Spray Shield and Gun stand

LABOUR ESTIMATE GUIDE

INSERTION flow sensor for continuous flow measurement

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

SECTION HVAC POWER VENTILATORS

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

CERTIFICATE OF APPROVAL No CF 681 INTERNATIONAL PAINT LIMITED

DVAX-ARS. Roof-mounted unit for mechanical smoke extract

MPA Chassis for Multi-Probe Magnetic Transducers

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Electromotoric Actuators

Ropox Shower & Changing Bed

AC Commercial Fans Edition. ErP ready

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

TERWA REBAR CONNECTION COUPLERS. CARES Technical Approval 5058 TA1B

TL210/TL310/ TL410 -WCS SERIES

HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE

HARDWARE KIT INSTALLATION GLOVES

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

XeteX, Inc. All Rights Reserved.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Fitting instructions for all. SitaAttika roof outlets and accessoires

TECHNICAL SPECIFICATION

Surge arrester POLIM-C.. HD

POSITIVE DISPLACEMENT FLOWMETERS

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

CERTIFICATE OF APPROVAL No CF 574. Sika Deutschland GmbH

Cold Air Intake Installation Instructions

SRT1000 Series THERMAL FLOWMETER

Tubular Screw Conveyor Capacity: Objectives:

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Materials : Cast iron body EN GJL-250

TECHNICAL SPECIFICATION

PCR 6. Operators Manual. Vertical Laminar Airflow Cabinet with U.V. Sterilisation. Issue 05 September 2013

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

FLANGES PRODUCT: STANDARD FLANGE CLASSIFICATION: PRESSURE CLASS CLASIFICATION:

Electromagnetic Flow Meter Owner s Manual HARDWARE

STT280 SEALED TILT SENSOR

High performance safety valve for the protection of large boilers and superheaters, certified to ASME Section I.

USER MANUAL. TSK and TSK V.

DIAMOND POINT VIBRATING PROBES

REBAR CONNECTION SYSTEM

Table of Contents. Page 2 of 10 HEIL/DOC/14-15/WAR_R0

CONSTRUCTION PRODUCT CATALOGUE.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

METAL DETECTOR AND REJECTION SYSTEM FOR PIPELINE APPLICATIONS

Automatic Roof Door Vents

Features. Marathon SL TECHNICAL CHARACTERISTICS. Sliding bushes: made of friction free and wear free material.

ORBINOX S.A. Pol. Ind. s/n ANOETA (Spain) Tel.: Fax:

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Silvertel. Ag9912M Ultra Miniature PoE Module. 1. Features. 2. Description. Tiny SMT package (14mm x 21mm) IEEE802.3af compliant.

Transcription:

Blast Valves for HVAC Ducting Introduction European EMC Products Ltd was established in July 1996 to supply high quality products and services to the Electro- Magnetic Compatibility (EMC) market. Quality European EMC Products are registered to BS EN ISO 9000:2008, certificate No. FS 38901. License scope: The design, assembly, servicing and testing of RF Shielded structures and equipment including EMI shielding and thermal management materials; Gas tight doors; and specialised mobile electromagnetic pulse protected (EMPP) containers. Blast Valves EEP s Modular Blast Valves are used when a large airflow is required through rectangular HVAC ducts and openings in blast resistant walls. They are suitable for both inlet and exhaust air and have been designed to with-stand loads of 1.0 MPa (10 Bar) from both sides. The modular blast valves can with-stand temperatures of up to 150 C. Design & Materials The valve consists of modules fitted into wall frames. The valves can be installed both vertically and horizontally. The valve closes on impact of the blast and also during the reverse pressure phase. When the blast has passed, the valve returns to its open position. The frames are made from steel and are designed for casting into concrete. If required they can also be supplied for bolting onto or welding into steel walls. The modules are made from aluminium alloy. Modular blast valve block designed to allow any size blast valve wall to be constructed. Blast valve NORMAL position Blast valve CLOSED position during blast wave POSITIVE phase Blast valve CLOSED position during blast wave NEGATIVE phase Page 1 of 5

Surface Treatment The frames are primed for a high level of corrosion protection. Other finishes are available on request. Air Flow Capacity The air volume at the required pressure drop will determine the total number of valves. The chart on the following page shows flow rates relating to one valve. The airflow/pressure drop is the same for both inlets and outlets. Blast Rating The valves have been designed and tested to withstand loads of up to 2.0MPa, and short duration loads of up to 10MPa. Accessories The wall frames can be fitted with particle filters and shields for protection against weather and shrapnel. Page 2 of 5

Sequence of Operation Overpressure Let through pulse Over pressure P + Under pressure Time T s T + Ts = Valve closing time (s) T+ = Overpressure duration (s) P+ = Maximum blast pressure at valve (Mpa) Page 3 of 5

Installation The blast valve is normally supplied in 2 parts: 1. Item A. Blast valve frame. 2. Item B. Blast valve. PRODUCT DATASHEET The frame (Item A) can be cast into concrete, or bolted to a steel frame. Item B is used after the frame is fixed. Actions before fitting the frame (Item A): Remove the packing from the frame. Check for transport damages. Check the label on the frame for drawing reference and serial number. Turn the frame to make the arrow point in the right direction. Check that the frame is turned with the side exterior in the right direction. Lift the whole unit into its position in the formwork, or into the steel mounting frame. Ensure that the frame is correctly aligned and fixed. Fix the frame properly by welding the anchor bars to the reinforcement. Or bolt into the mounting frame. Do not weld anything to the valve frame, as this will damage the surface treatment. Blast valve module in frame for casting into concrete. The formwork is to be firmly fixed to the valve unit preventing concrete between the valve and the formwork ensuring that the valve flanges will be at the face of the barrier. Seal any gaps between the valve frame and the formwork with suitable sealant. Blast valve module (Item B) with fixings Page 4 of 5

Pour the concrete, if applicable. Check the frame for concrete stains and clean it from concrete after the formwork has been removed. Make paint repairs. Take item B unit to the place of installation Remove the packing and check for any transport damages. Place the first valve at the bottom of the frame and fix it to the frame with 4 bolts and nuts. Mount the following valves modules on top of each other in the frame fixing them to the frame in the correct installation order. The bolts are tightened with 13 mm socket to a torque of 25 Nm. It is important that the frames are properly treated for corrosion protection before the blast valves modules are installed. Blast Module Component parts Mounting blast valve module (Item B) into frame (Item A) Tightening blast valve unit (Item B) into the frame (Item A) Page 5 of 5