GA PLUS Ordering Information. Earth Leakage Motor Protection Relay Kits

Similar documents
Series Motor Protection

KD LV Motor Protection Relay

LA Motor Protection. A South African Company to be Proud of

Electromagnetic Industries LLP

DIGITAL EARTH LEAKAGE RELAY

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

ampcontrol s Hard rock relay range

Signal Power Supply Monitoring & Restoration

DEEP SEA ELECTRONICS PLC

Metering Products. Metering Products Protection Units April 1, Price List. Price List. With effect from April 1,

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

Heat Tracing Sales Mt. Airy, Maryland Controls

SURE-TRIP OEM RELACEMENT TRIP UNIT

M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

SURE TRIP RETRO KITS

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Metering Products Protection Units Current Transformers. April 1, 2015

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

RVS-DN Digital Reduced Voltage Motor Starter

Programmable Logic Controller. Mat Nor Mohamad

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Bulletin 825 SMM Smart Motor Manager

ELD Earth Leakage Protection Relay

3 - Protection components Motor circuit-breakers

ELM V2 EARTH LEAKAGE PROTECTION RELAY User Manual. Revision: 1, JULY/2018 Designed and manufactured in Australia by Ampcontrol Pty Ltd

DEEP SEA ELECTRONICS PLC

Government Polytechnic Muzaffarpur Name of the Lab: Electric Traction-II Lab

Technical Journal September 2012

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Instruction Manual. Q Series 2 Motor Control Modules - OEM

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

WESTINGHOUSE / CUTLER HAMMER DS POWER BREAKERS

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Industry Automation Control Components

DPX moulded case circuit breakers

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Residual current devices

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

ASYN205B Central Synchronizing Controller

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Protection and control P. 1 /2. Smart earth leakage protection

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

CONTENTS. Earth leakage and overload/short circuit protection systems with self-reclosing Associated breaking element

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

Job Sheet 1 Electrical Panel Familiarization

825-P Modular Protection System for motors Specification Guide

Effective discrimination of protective devices

Transformer Protection

Residual Current Circuit-breaker (RCCB) FH 200 Series

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

CHAPTER 4 PROTECTION REQUIREMENTS

Case Study on On EHV Circuit Breaker Flashover NTPC-SINGRAULI

New range of reclosing systems

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

USERS MANUAL MCD REMOTE OPERATOR

RVS-DX Digital Reduced Voltage Motor Starter

mgard-10 microprocessor-based relay

SECTION MOTOR CONTROL

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

Part # Features & Applications Specifications Cross Reference

Phoenix Multi Inverter/Chargers

Product selection table

GP/GPA GROUND FAULT PROTECTION

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Deep Sea Electronics Plc

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

DEEP SEA ELECTRONICS PLC

EE042: Practical Power System Protection for Engineers & Technicians

Latching SPST EPIC Sealed Contactor Amp Power Switching RoHS Compliant, all date codes

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Controls and Instruments

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

P.1 CONTENTS. Industrial Earth Leakage Protection. Page

Application Description

COMPLETE SOLUTIONS FOR POWER PROTECTION

Power System Solutions (PSS)

Issue Abbreviated MSP numbering system AUMA MATIC Types AM. Uncontrolled copy! EWH-25 GB-10. Quality Management System AUMA-Group

Transcription:

PLUS Ordering Information Earth Leakage Motor Protection Relay Kits

About The NewElec Earth Leakage relay provides earth leakage protection also known as ground fault protection designed to protect personnel and equipment by rapid disconnection of main supply to faulted equipment a unique feature is the integrated distinguishing between Earth leakage and Earth fault routing trips to incoming circuit breaker rather than the fault level limited main circuit contactor. Pioneers of the harmonic suppression circuit characteristics, the Earth Leakage protection relay enables more sensitive earth leakage protection of high kilowatt motors started direct-on-line as well as variable speed drive applications without nuisance tripping, this is achieved utilising band pass filters as well as incorporation of a screen winding on the CBCT to ensure even flux distribution under high starting current conditions The Plus comes fitted with an integrated earth leakage test push button connected to the test winding on the CBCT allowing one to test functionality of Plus and trip circuits a rear accessed RS232 interface allowing customers to configure output trip relay configuration options, including Latched or Non-latching main trip contact, or Non options, as well as 110V-220V or 380V-525V A.C. auxiliary supply voltages. The trip contact current rating is a sturdy 6A at 220V and 3A at 525V A.C. A latched contactor trip change-over contact can only be reset by pressing the control panel mounted pushbutton. Sensitivities range from 30mA to 1000mA with user selectable instantaneous or IDMT curve selection while using the same earth leakage core. Features Include: or non fail-safe option Earth Leakage Protection Earth Fault Protection 110V / 220V A.C.or 380V / 525V A.C. supply or non-latching trip contact Instantaneous or IDMT curve selection Latched contactor trip C/O contact Harmonic Suppression Adaptor plate to fit 71 x 94mm cut-out Intergrated Earth Leakage Test Push button User programmable options ( MA selection, or Non-, Failsafe or Non-Failsafe, 110/220V or 380/525V)

Ordering Details 1 - P L U S - 0 2 5 0-3 - 4-5 Standard = 0 ELX Model 4 - or Non- Main Trip 380V / 525V A.C. = D Example: -A-0500-B-0-D 126 mm 126 mm 146 mm 62 mm 56 mm 66 mm 86 mm

C.B.C.T Selection BTX0015 C.B.C.T 400 BTX0014 C.B.C.T 200 BTX0013 C.B.C.T 190 mm BTX0012 C.B.C.T 150 mm BTX0011 C.B.C.T 63 mm ID BTX0010 C.B.C.T 43 mm Product Code FPR0932 BTXxxxx Description 0-PLUS-0250-0-0-0

Earth Leakage Motor Protection Solution to Suite: 30mA Sensitivity Product Code Description FPR0931 0-PLUS-0030-0-0-0 BTX0010 C.B.C.T. 1100/1 PLUS 43mm ID Ordering Information: 1 - P L U S - 2-3 - 4-5 Standard = 0 ELX Model 4 - or Non- Main Trip 380V / 525V A.C. = D

Earth Leakage Motor Protection Solution to Suite: 250mA Sensitivity Product Code Description FPR0932 0-PLUS-0250-0-0-0 BTX0010 C.B.C.T. 1100/1 PLUS 43mm ID Ordering Information: 1 - P L U S - 2-3 - 4-5 Standard = 0 ELX Model 4 - or Non- Main Trip 380V / 525V A.C. = D

Earth Leakage Motor Protection Solution to Suite: 375mA Sensitivity Product Code Description FPR0933 0-PLUS-0375-0-0-0 BTX0011 C.B.C.T. 1000/1 PLUS 63mm ID Ordering Information: 1 - P L U S - 2-3 - 4-5 Standard = 0 ELX Model 4 - or Non- Main Trip 380V / 525V A.C. = D

Earth Leakage Motor Protection Solution to Suite: 500mA Sensitivity Product Code Description FPR0934 0-PLUS-0500-0-0-0 BTX0011 C.B.C.T. 1000/1 PLUS 63mm ID Ordering Information: 1 - P L U S - 2-3 - 4-5 Standard = 0 ELX Model 4 - or Non- Main Trip 380V / 525V A.C. = D

Earth Leakage Motor Protection Solution to Suite: 1000mA Sensitivity Product Code Description FPR0935 0-PLUS-1000-0-0-0 BTX0012 C.B.C.T. 1000/1 PLUS 104mm ID Ordering Information: 1 - P L U S - 2-3 - 4-5 Standard = 0 ELX Model 4 - or Non- Main Trip 380V / 525V A.C. = D

Physical Address: 298 Soutter Street, Pretoria West www.newelec.co.za sales@newelec.co.za