Design and study of distributed photo-voltaic power generation system in sewage treatment plant

Similar documents
Combination control for photovoltaic-battery-diesel hybrid micro grid system

Mathematical Modeling Analysis of Operation Strategy after External Transmission Line Series Compensation

Wind Energy System.

TECHNICAL PAPER ON SOLAR PV INSTALLATION & DESIGN AT IIT BHUBANESWAR

Where. Where there s sun. there s SUNGEN.

Shkel Photovoltaic Parks in Albania. August 2017

MPPT Control System for PV Generation System with Mismatched Modules

Design of solar supply system for water quality improvement equipment. used in the pond

2. The Type, Structure and Technical Characteristics of 2 Box Type Substation

Design and Installation of A 20.1 kwp Photovoltaic-Wind Power System

Development of the Single Phase PV Inverter SANUPS P61A

Advances in Engineering Research, volume 93 International Symposium on Mechanical Engineering and Material Science (ISMEMS 2016)

Introduction to Solar PV. Basics

LAYOUT REPORT OF GROUND MOUNTED PROJECT

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city

LAYOUT REPORT OF ROOFTOP PROJECT. For 115 kwp. Order No. # Date 13 October, Name of Place California.

O&M Requirements for Utility-Scale Solar PV and Energy Storage. Nicholas Jewell, Ph.D., PMP Sr. Research Engineer Research & Development LG&E and KU

GRIDCON ACF ESS GREAT COMBINATION ACTIVE FILTER AND ENERGY STORAGE.

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

Airports Going SOLAR! Michael Shonka

Onix Structure Private Limited. Solar PV Power Generation System Detailed Project Report

Research on the Structure of Linear Oscillation Motor and the Corresponding Applications on Piston Type Refrigeration Compressor

PV Generation System. Solar Charge Controller SPECIFICATION

Modeling and Analysis of Vehicle with Wind-solar Photovoltaic Hybrid Generating System Zhi-jun Guo 1, a, Xiang-yu Kang 1, b

P H O T O V O LTA I C

String Monitoring and Control System for Solar Photo Voltaic Power Plants

Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.

Development of Pumped Storage Power Station in China

Solar Powered System - 2

IEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE

Mini-Grid PV Installations

Integrated Monitoring System Design of Hybrid Aircompressors

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

Chengdu, , China. Shanghai, , China. Keywords: Transmission Line; Online Monitoring; Energy-Saving

Solar Energy Opportunities for New Schools July 10, School Board Work Session

Design of Large-Capacity Battery Energy Storage System and Its Application in Coal Mine

Research on PV and battery control system with energy management technology in stand-alone DC micro grid

A starting method of ship electric propulsion permanent magnet synchronous motor

Title Goes Here and Can Run Solar Photovoltaic up to 3 lines as shown here Systems as you see

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

New Central Grid-tied PV Inverters. 500kW/1MW 3-level T-type modular inverters 1MW/2MW PV power containers

ESCI 61- PV Cells Modules and Arrays April 21- Week 3 Agenda

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

2016 Photovoltaic Solar System Plan Review List

Next Generation of UHVDC System. R. Montaño, D Wu, L. Arevalo, B. Jacobson ABB - HVDC Sweden

Development of the 3-phase PV Inverter SANUPS P83D

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

SOLAR ENERGY ASSESSMENT REPORT. For 115 kwp. Meteorological Data Source Meteonorm. Date 18 October, Name of Place California.

LOT Kwp Solar PV Power Solution with Battery Backup

Application of PLC in automatic control system in the production of steel. FAN Zhechao, FENG Hongwei

PV SYSTEMS. The main components of a PV system are an array of PV panels and an inverter.

Solar Pump System. Shenzhen Veichi Electric Co., Ltd. Suzhou Veichi Electric Co., Ltd. Service hotline :

World Scientific Research Journal (WSRJ) ISSN: Multifunctional Controllable and Detachable Bicycle Power Generation /

Glossary. * Credit for glossary starter: Florida Solar Energy Center. August 2015 PV Installer's Course: Glossary 1

Microinverter - The new PV technology upgrade

Tabuchi Electric Inverter Quality & Reliability Overview February 2017

TANZANIA BUREAU OF STANDARDS

Micro-grid Case Study in China

Solar Photovoltaic (PV) Design Considerations & Issues. By Paul M. Williams, President & CEO

GRID CONNECTED 400kWp SOLAR ROOF TOP POWER PLANT NET METERING AT KARNATAKA STATE CRICKET ASSOCIATION M. CHINNASWAMY STADIUM, BENGALURU

Technical standard for AC, DC and street light systems

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

Design and Simulation of Grid Connected PV System

Power Grid and Alternating Current Distribution Research of Renewable Energy Generate Electric Power s Village System

Off-grid Power for Wireless Networks. Training materials for wireless trainers

Measurement of Tank Cooling Airflow Based on Array Sensors

Research on Bill of Engineering Quantity and Calculation Standard for Power Grid Marketing Project Bin ZHU 1, Yun HE 1 and Zhang-hua CAI 2

Solutions. for large buildings and power plants

Capabilities Brochure

EXPERIMENTAL INVESTIGATON OF SOLAR PANEL PERFORMANCE AT VARIOUS ENVIRONMENTAL CONDITIONS

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

SI30 Series Solar Pump System

The Modeling and Simulation of DC Traction Power Supply Network for Urban Rail Transit Based on Simulink

PRESENTATION ON HYBRID SOLAR SYSTEM BASED ON SUN SINE SMART MICRO INVERTERS

SPG-400. Solar-powered generators

Wind-Solar Hybrid Power Generation Systems. Energy Pvt. Ltd.

Technology and Application of Centralized DC Power Supply for LED Street Lamp

Research And Development Of Variable-Speed Scroll Compressor

Solar Photovoltaic Panels

Power Voltage Transformers for Air Insulated Substations

Analysis and Design of the Super Capacitor Monitoring System of Hybrid Electric Vehicles

Concepts and Installation of Grid Connected PV Systems NIUE, July 2009

WOLUN. ZN63A-12 (VS1) Type. ZN63A-12 (VS1) Type Indoor High Voltage Vacuum Circuit Breaker. General Introduction. Technical Specification

CALB CALB CALB. A leading company devoted to li-ion battery for various applications.

Site Visit to Green Electric Energy Park at Curtin University, Perth, Western Australia. Institution of Engineers Sri Lanka Western Australia Chapter

Grounding systems for power supply facilities

off-grid Solutions Security of supply Basics: Off-grid energy supply

Current Automation Catalogue

Final Report. Competitive Analysis: Levelized Cost of Electricity (LCOE) Rev C: January 24, 2008

100kW GROUND MOUNTED SOLAR PHOTOVOLTIC POWER PLANT DETAILED PROJECT REPORT AERO SPACE MATERIALS PVT LTD

Energy Saving by Implementation of Intelligent Systems in Lighting Abstract 2. Analysis of Outdoor Lighting Systems 1.

Distribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world

OFF GRID SOLAR INVERTER

The design and implementation of a simulation platform for the running of high-speed trains based on High Level Architecture

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

Micro-Inverter. Corporate and Product Presentation. AEconversion GmbH & Co. KG. Micro vs. String. Product Details. USPs. Market Overview.

Photovoltaic Solar Plan Review

ABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition

Transcription:

Design and study of distributed photo-voltaic power generation system in sewage treatment plant Zhang Mingsheng 1,Wu Hesong *2,Wan Wenkui 1,Feng Peilei 3 1 Kunming University of Science and Technology Oxbridge College Kunming, China 2 Diqing Grid Bureau, Yunnan Grid Corporation Limited, Diqing StateDiqing, China 3 School of Electrical and Information TechnologyYunnan Minzu University Kunming, China Abstract.With the rapid development of the global economy, solar photovoltaic power generation has attracted wide attention all over the world. With the rapid development of all kinds of new energy in the world, photovoltaic power generation has a huge international market and broad prospects for development. This paper analyzes the feasibility of the distributed photovoltaic power generation system in this city, based on the actual situation of a photovoltaic power generation project in a certain place. Through the type selection of a variety of solar cell groups, component installation, operation mode selection, and inverter selection, Therefore, a more reasonable PV module and electrical part(the design and study of the first part, the two part of the electrical system and the lightning protection measures) are designed. The research shows that the comprehensive value of photovoltaic power is very high, and the distributed photovoltaic power station can be built in the areas where the geographical conditions are suitable and the light is sufficient. After the completion of the above power generation projects, the local solar energy resources will be fundamentally transformed into economic advantages. 1 Introduction With the rapid development of the global economy, the demand for electricity in every country in the world is increasing year by year. The clean and green energy such as solar energy, wind energy and geothermal energy has been widely recognized and concerned worldwide [1]. At present, the core technology of photo-voltaic power generation has been slowly mature track, the rapid development of solar photo-voltaic power generation technology to the national economy played a crucial role in the global energy highly stressful situations, this technology can also meet the people of new energy demand. Taking a city in China as an example, the city is one of the most developed areas of China's solar energy resources. The transparency in the atmosphere is relatively high, and its total radiation value is basically in a certain range. Solar energy can be sustained output, and fully meet the necessary conditions for solar energy development. The city carries out the planning and construction of the photo-voltaic power plant project, which will vigorously promote the high speed development of the local distributed photo-voltaic power plant construction [2]. 2 Research On Pv Distributed Generation System 2.1 Solar cell assembly The solar cell component is the most basic structure unit in the distributed generation system. single solar cell is rarely used for power supply. Instead, the batteries are connected in series or in parallel to be packaged into different power solar photo-voltaic components. As the core part of the system, the quality and cost of solar cell components represent the basic parameters of grid connected power generation system to a large extent. The solar photo-voltaic components with reliable quality, stable performance and good encapsulation can work for 20 years in a wet and humid environment [3]. 2.1.1 Types and properties of solar cells The performance of various types of photo-voltaic cells is different, and the performance of each type of solar cells is more detailed in Table 1. The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

Component conversion efficiency Table 1. Three kinds of common so lar battery control Crystal silicon Thin film solar solar cell cell Amorphous silicon solar cell 14% 6% Less than 14% Land area /1MW Less than 30 mu More than 40 mu Comprehensive cost low Middle high Life long Middle short contaminated nothing Metal pollution nothing It can be seen from table 1: crystalline silicon solar cell has longer operation life than thin film solar cell and amorphous silicon, and the cost is relatively low and no pollution. It is more economical and reliable for large and medium-sized photo-voltaic power station. 2.1.2 Selection of solar cell components Large photo-voltaic grid connected power plants should choose the types of PV modules with mature technology, high conversion efficiency, large-scale production and widely applied engineering. They are mainly monocrystalline silicon photo-voltaic modules and polycrystalline silicon photo-voltaic modules. The main difference between the two components in the engineering application is that the photoelectric conversion efficiency of the monocrystalline silicon cell is slightly higher, and the layout aspect is slightly more economical. In practical applications of photo-voltaic power stations, monocrystalline silicon cells and polysilicon batteries are available. The total installed capacity of the project is 4.9218MWp, and the area of the project is tense. It is appropriate to choose the high About 35 Mu efficiency double side component as far as possible. In addition, this area is located in the southern region, with more humid and hot climate. In addition, PV modules are arranged above the anaerobic pond and sedimentation tank of the sewage treatment plant. The PV modules are in a high temperature and high humidity environment for a long time. The use of double glass modules can effectively prevent the generation of PID. Therefore, this article selects 300Wp (positive power) /60P double double glass component. 2.2 Type selection of inverters Table 2. Comparison of the parameters of two inverters Inverter Parameters Centralized Inverters String Inverters Grid connected inverter plays a very important role in the conversion efficiency and reliability of the system. In order to improve the efficiency of the system, the cost of power generation should be reduced to a minimum[4].the internal structure of the inverter and its control method are studied, which is one of the differences between the grid connected inverters and the other inverters. The parameters of the two inverters are compared as shown in Table 2. Rated output power 100-500kw 10-50kw Protection grade Indoor IP20, outdoor IP54 IP65 Cooling method Air blast cooling Natural heat dissipation system composition Step by step confluence Non fuse design, external fan From table 2, it can be obtained: By comparing group string and centralized application scenarios in distributed photo-voltaic. Centralized, series type and inverters can meet the requirements of the power grid access. In terms of reliability, the series inverter has high protection level, no fuse, no external fan free maintenance design, easy maintenance, small failure influence surface, and it can bring more benefits. Therefore, this project selects a series of series inverters. According to the characteristics of the project, the 50kW series inverter is used in this photo-voltaic power generation project, and the inverter should have the anti PID device. 2.3 The design of a photo-voltaic array The solar cell components often used in the photo-voltaic power station include a fixed bracket, an inclined single axis tracking bracket, a horizontal single axis tracking support, and so on. This project is located in the South and near the regression line, and the effect of the tilting fixed lifting slope radiation is low. Because the project is to use the sewage treatment plant's anaerobic pond, sedimentation tank, discharge area and other areas, flexible support is used to arrange photo-voltaic modules over it, so the installation and adjustment of components is very difficult. In consideration of the project, it is recommended to use fixed array operation mode. 2.3.1 Unit system scheme and configuration The total station consists of four sets of series inverter power generation units, each of which is composed of a 2

photo-voltaic array, a inverter and a confluence device. In the series inverter power generation unit, every seven photo-voltaic groups are connected by 1x4mm2 photo-voltaic cable to a series of series inverters. Every six sets of series inverters are connected by a 3x25 cable to an AC confluence box. Every 4/6 AC junction box is connected by 3x150mm2/3x240mm2 cable to 1 box changes. The group series inverter is distributed evenly in the PV array and installed on the outdoor photo-voltaic scaffold. In order to save the cable and reduce the loss, the box type substation is arranged in each unit near the overhaul road [5]. 2.3.2 Series parallel connection scheme of PV module The maximum allowable input voltage Udcmax of the PV grid inverter is 1100V, and the input voltage MPPT operating range is 200~1000V. The rated open circuit voltage of PV module is Voc 39.6V, and the open circuit voltage and temperature coefficient is -0.29%. The rated peak power and voltage Ve is 32.9V, and the peak power and working voltage temperature coefficient is 0.38%. The maximum allowable system voltage is 1100V. According to the calculation, the number of photovoltaic components in this project should be less than 25 and more than 8. For example, table 3: Table 3. Group number calculation range N <= 25.80379 7.5523944 <= N <= 27.71003 The number of group strings should be even 18, 20, 22, 24, etc. The operating voltage range of the group is all within the voltage range of the inverter MPPT, which is helpful to improve the efficiency of the inverter. For example, table 4: Table 4. Series voltage calculation table 20 21 22 23 24 Open circuit voltage of minimum ambient temperature group(v) 852.6 895.2 937.8 980.5 1023.1 Maximum ambient temperature group working voltage(v) 531.6 558.2 584.8 611.4 638 Maximum ambient temperature group working voltage(v) 721.7 757.8 793.9 830 866.1 It is visible from the data in Table 4: When twenty-four components are selected in series, the open circuit voltage of the photo-voltaic group string is 1023.1V. The voltage value is less than the maximum DC voltage 1100V of the inverter, but it is higher than the maximum insulation tolerance voltage 1000V of the PV module. When twenty-two components are selected in series, the open circuit voltage of the photo-voltaic group string is 937.8V. The voltage value is less than the maximum voltage 1100V of the DC side of the inverter and the maximum insulation withstand voltage 1000V of PV module, and the inverter and PV module can work normally. Therefore, the selection of twenty-two photo-voltaic components in series in this project has the best technical and economic performance. The number of parallel circuits of solar cell string: Calculation of rated power capacity of each component in series is 300Wp * 22=6600Wp, Each series of series inverter is parallel to seven sets of series, each photo-voltaic area is equipped with a 35~37 power inverter with a power of 50kW, and each 4/6 inverter is connected to a confluence box. Each photo-voltaic area is arranged with 244~252 clusters, and the single area capacity is respectively: 244x6600=1.6104MWp; 252x6600=1.6614MWp; 250x6600=1.65MWp. 2.4 Design of square array connection 2.4.1 Array layout The design of connection principle of series boost, two stages parallel converge, in-situ inverter and local boost are adopted to photo-voltaic module. The connection of the series connection should pay attention to the matching of the working current of each photo-voltaic module in the loop. The working current is mainly influenced by the solar irradiance. The working current of the PV module on the same oblique plane at the same time is the same. The parallel connection should pay attention to the matching of the working voltage of the series circuit. The working voltage is mainly influenced by the working temperature of the battery. The working voltage of the series circuit is also affected by the voltage loss on the wiring cable. In order to reduce the difference in the working voltage of the series circuit, the series circuit with similar position is parallel in parallel. When the series inverter is arranged, it is considered in the middle position of the series circuit. 2.4.2 PV module wiring The total station consists of 3 series of series inverter power generation units. Each square array of photo-voltaic cells is composed of a photovoltaic group string, a inverter device and a confluence device. In the series inverter power generation unit, every 7 photo-voltaic groups are connected by 1x4mm2 photo-voltaic cable to 1 series of series inverter. Every 6 sets of series inverters are connected to 1 AC confluence boxes from 3x25 cable. Every 4/6 AC junction box is 3

connected by 3x150mm2/3x240mm2 cable to 1 box changes. 2.4.3 Series connection and parallel connection For large photo-voltaic grid connected power generation system, in order to reduce the connection between PV modules and inverters, facilitate maintenance and improve reliability, two level confluence plans are generally needed. For group series inverter, it is two level AC confluence. The first stage confluence is located in the series inverters which there are the 8 circuit input circuit. The second level confluence is located at the exchange box [6]. 2.4.4 Series connection inverter connection The series inverter adopts single bus connection, which is more than one out. The main technical parameters and functions are designed as follows. 1) Input side (8 ways): The input side has a DC input switch which the rated current is 16A and the rated voltage DC is 1000V. The position signal of DC switch hopping switch are sent to the main control room. 2) Output side (1 way): The main circuit has 3 pole plastic case circuits breaker which the rated current is 80A and the rated voltage AC is 600V. The position signal of the jump lock of the plastic shell circuit breaker is sent to the main control room. 2.4.5 AC junction box wiring A single bus connection is used for the exchange box. The main technical parameters and functions of the confluence box components are designed as follows. 1) Input side (6 ways): There are 3 pole plastic case circuits breaker which the rated current is 80A and the rated voltage AC is 600V on input side. 2) Output side (1way): There are 3 pole plastic case circuits breaker which the rated current is 400A and the rated voltage AC is 600V on output side. 3 Electrical design part 3.1 Electrical primary connection In general, the electrical primary schematic diagram is shown in Figure 1. Figure 1. A schematic diagram of the primary principle of distributed photo-voltaic power generation system As shown in Figure 1, the city grid connected by the distributed photo-voltaic power system is based on its voltage level and access device [7]. An independent metering device for the power supply line of the distributed photo-voltaic power generation system is set up. There are 1 1.6104MWp, 1 1.6614MWp and 1 1.65MWp photo-voltaic power units in this PV power station. They set 3 double winding combination boxes change. Each 10kV box becomes separate to10kv PV line cabinet. They are 3 feeder cabinets. The ZC-YJV22-8.7/15kV- 3x50 cable is sent to the first class of the switch station, and then the 1 back line is connected to the total distribution room of the sewage treatment plant. 3.1.1 General layout of electric plane The general layout is clear, compact and reasonable. It is easy to make out the line, reduces the area of land and saves the investment. The PV array is a square array with each 1.6104MWp /1.6614MWp/1.65MWp, with a total of 3 square arrays. The series inverter is installed on the photo-voltaic support. The box is arranged in the middle of the photo-voltaic area and closes to the road layout, it convenient for transportation, maintenance and maintenance. Prefabricated cabin cloth is placed on the west side of the adding room, near the general distribution room. 10kV distribution device: A metal armored handcar of type switch-gear is arranged in a single prefabricated cabin Station power: this station has a 50kVA station transformer and one low voltage distribution screens in the first cabin. Lighting: in order to meet the night inspection requirements of the staff of the sewage treatment plant, this project increases the lighting lamp under the photo-voltaic support of the biological pool. The lighting and ventilation of the prefabricated and box changes are all provided by the equipment manufacturers. 3.2 Electrical part two In this project, 1 main control rooms are set up in the switch station, which is used to place measurement and control, protection, measurement, DC screen, operator workstation, microcomputer five workstation, video and environmental monitoring system, time synchronization system, AC uninterruptible power supply and two times screen cabinets. Each battery pack screen is arranged in the main control room. 10kV protection measurement and control device and meter are distributed in 10kV high voltage switch-gear. The monitoring method used in this photo-voltaic power generation system is centralized control. The main monitoring technology is computer network monitoring and control system of microcomputer protection device, which can complete the data acquisition of the whole station mechanical and electrical equipment. The collected data are used to monitor, control, measure, protect and so on. By uploading to a specific monitoring computer in the network, remote monitoring can be realized. The time 4

recording function of the computer monitoring system is completed by the GPS device. 3.3 Lightning shielding measures Solar photo-voltaic power generation has emerged as an environment-friendly power generation industry in recent years. There is no clear specification in China to explain how to carry out the lightning protection design of the photovoltaic power plant. The division of the lightning protection area is shown in Figure 2. power generation is 5.1976 million kw.h. 25 years of power generation accumulative 118.2452 million kw.h. The average power generation capacity of 25 years is 4.7298 million kw.h. The average annual use hour is 946.472 hours. Solar photo-voltaic power station has a large investment, low operating cost and high cost of power generation. According to China's national conditions, we can build photo-voltaic grid connected power stations in China with abundant solar energy resources, and appropriately increase the subsidy amount of grid connected photo-voltaic generation, so as to promote the development of all aspects of photo-voltaic industry, thus promoting the effective development of photo-voltaic power generation in China. References Figure 2. Division of lightning protection area A protected area can be divided into a different level of protection from outside to inside, and the most dangerous area is the outermost level zero. It is clear that the inverter room in the power station has only a layer of shielding, because it has only one wall between the area zero. The space in the complete set of machine rooms is defined as the area one. The outer shell of the electrical equipment in the machine room becomes a layer of shielding, and the space in the electrical equipment is defined as area two. A large number of cables in the solar cell array are exposed to the outdoors and are easily exposed to direct lightning, which can easily damage the cable. Therefore, within the scope of the actual circumstances, the cable should be laid along the cable slot box, the bridge frame and the bridge cover plate, which can be a good protection for the cable and prevent the strike of direct lightning [8]. 4 Conclusion The scale of the project is about 4.9218MWp, which belongs to the medium-sized photo-voltaic power generation project. The total solar radiation of the level of the project is 4338MJ/m2 a. The solar energy is rich and has the development conditions. After the photo-voltaic power station was built, the first year's 1. Wu Yaqiong. A brief discussion on distributed photovoltaic power generation system [A]. Chinese high-tech enterprises, 2016, 13. 2. Liu Zhang Qiang. A brief discussion on electrical system of large ground grid connected photovoltaic power station [J]. Power information, 2017:224-225. 3. Song hao ping. Selection of battery components for large grid connected photovoltaic power stations [J]. Gansu water conservancy and hydropower technology, 2015, 5 (10): 53-55. 4. Wang Wei. Selection and design of photovoltaic grid connected inverter [J]. Technology entrepreneur, 2012, 10. 5. Roger. Current situation and Prospect of grid connected photovoltaic power generation and its related technologies [J]. low carbon technology, 2016, 71-72. 6. Guan Rende, Li Jianquan, Zhang Rong and so on. System design of building photovoltaic grid connected power station [J]. High power converter technology, 2013, 15-20. 7. Ai Xin, Han Xiaonan, Sun Ying Yun. Photovoltaic power grid and its related technology development status and Prospect [J]. modern electric power, 2013, 30 (1) 1-2. 8. Zhu Lin. Brief discussion on the design of large grid connected photovoltaic power plant system [J]. Electronic world, 2012, 7 (18): 58-59. 5