Transformer Disconnects Specifying Product Catalog Numbers

Similar documents
Transformer Disconnects

50 Series. Features. Suffix Suffix Series Voltage Combinations

FUSES 8.1. Questions? Answers at Western US: CED-ELEV

Engineered solutions for power and the environment

Bulletin A 1497B 1497D Type Control Circuit Transformer Machine Tool Transformer Control Power Transformer General Purpose Transformer

UL489 or UL1077? What are your Circuit Protection Requirements?

Bulletin 505 Full Voltage Reversing

TA Ta VA CTRL-XFRMR

Industrial Control Transformers

Totally Enclosed Non-Ventilated

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

Compact Circuit Protector (CCP)

Jim Baker President, Electro-Matic Products, Inc.

FUSIBLE DISCONNECT SWITCHES

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Three-Phase Ventilated

UL248 North American Low Voltage Fuses

D I D /240 I. D x /240 I D / x x /24 I. D x /120

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

overvoltage solutions

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

General Purpose Buck - Boost Wiring Diagrams... 86

Midwest Dry Type Transformers

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Overload Relay Heater Tables

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

HPS TITAN HPS TITAN. Three Phase. Single Phase

PULLOUT DISCONNECT SWITCHES

CPT Series Control Transformers

V217276J /2 ATDR4-1/2 Z217786J 10 5 ATDR5 K218302J 10 6/10 ATDR5-6/10 Z218821J 10 6 ATDR6

Elevator Parts and Accessories

Tanning Bed Transformers

Equipment Protection. Transformers 600V or Less

Industrial Control Transformers

Table of Contents General Information Fuseholders NEW Power Blocks NEW Heavy Duty Terminal Blocks Single and Double Row Terminal Blocks

Application Information Need to know how? You ve turned to the right place...literally.

Dry Type Distribution Transformers

Transformers 6. Gross Automation (877)

Jefferson Electric Class I Division 2 Transformers for hazardous locations

Dry Type Distribution Transformers

Multi-Pak Group Control

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

CLASS J 600 Volt Fuse Blocks

NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric

Installation Instructions

Application Information

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B

Reduce Downtime With Quick Access to the Right Replacement Fuse

Dry Type Distribution Transformers

General information about motor protection

Consumer Aftermarket Product Catalog Glass and Ceramic Tube Fuses

SECTION PANELBOARDS

Product Guide. NEMA pump controls.

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Bulletin 1497A Machine Tool Transformers

Low Voltage Fuses For Motor Protection

Single-Phase Ventilated

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Compact Circuit Protector (CCP)

GMA GDB/GDA MDL MDA. Fuses SMALL DIMENSION. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price. Item Number Amps Price

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Electrical Design/Build Guide

Dry-Type Transformers Mini-Power Centers

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Move to modern enclosed disconnect switch technology. Enclosed disconnect switches eot Manual motor controllers

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Transformer Disconnects

HPS Fusion General Purpose Enclosed Transformer

NEMA Contactors & Starters (Freedom)

HPS Titan. Encapsulated Transformers for Harsh Environments

Industrial Control Transformers

The easiest and fastest way to select and specify the right control circuit fuse

AREA OF WORK ENERGY

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Industrial Control Transformers

Dry Type Distribution Transformers

Variable Transformers Series to Amperes

SPEEDFAX TM 2011 Disconnect Switches Contents

Medium Voltage Metal-Enclosed Switches

footprint of traditional fusible switches

Compact Circuit Protector (CCP)

SURFACE TRACK (120/250V) SPECIFICATIONS

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Fuses Contents. Fuse Information 30. Fuse Cross Reference Table 32. British Standard Fuses 34. Miniature Fuses 46. Cartridge Fuses 56

Product Specification Sheet #3LD2.1

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

Customer Requirements Downtown Secondary Network Service

Receptacles & Wall Boxes with Integral Circuit Protection

Inexpensive as. Applications

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Installation and Construction Notes for EVSE4

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Compact Circuit Protector (CCP)

Installation Instructions

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Transcription:

SPECIFYING PRODUCT CATALOG NUMBERS Transformer Disconnects Specifying Product Catalog Numbers When ordering, specify the following information: Class, Type, VA rating, Enclosure, Voltage code, and Form(s). Sample Catalog Number Class Type VA Rating Enclosure Voltage Code Form(s) 9070 SK 1000 A2 D1 N3 Forms are added after the voltage code in alphabetical order: For example, to order a 1000 VA, A2 enclosure with the following options: Electrostatically-shielded, duplex receptacle, NEMA 3R Use this catalog number: 9070SK1000A2D1N3 5

NEMA 1 Transformer Disconnects NEMA 1 TRANSFORMER DISCONNECTS Standard NEMA 1 Offering (G1 and G2) G1 G2 250 3000 VA block requires: 1-1/2-inch x 13/32-inch rejection-style primary fuses Conveniently located 1/2-inch to 3/4-inch knockouts External mounting flanges with slotted holes for hook and hang mounting D A B C ON E OFF 1/2-3/4-inch Knockouts G 90 I J F H 1/2 3/4-inch Conduit Table 1: Enclosure Dimensions VA Enclosure A B C D E F G H I J 250 1000 G1 10.80 1.70 6.00 11.80 9.40 8.96 16.81 2.09.32.32 1500 3000 G2 13.80 1.70 10.00 14.80 13.40 12.21 23.06 2.09 1.00 1.00 Table 2: Factory Available Options for Standard 9070 SK Units (Enclosures G1 and G2) 55 C rise transformer C ** Primary fuse block 5-inch x 13/16-inch * F30 Two duplex receptacles, door-mounted * G16, with strain relief P2 * Available on G2 enclosures only. If required on 250 1000 VA, change G1 to G2 in catalog number ** Not available on 3000 VA 6 2003 2005 Schneider Electric All Rights Reserved 04/2005

NEMA 1 Transformer Disconnects Standard NEMA 1 Offering (G4) Voltage 480 to 120 (D9) 5000 VA G4 block requires: 1-1/2-inch x 13/32 rejection-style primary fuses 3-inch x 3/4-inch secondary fuses Conveniently located 1/2-inch to 3/4-inch knockouts External mounting flanges with slotted holes for hook and hang mounting 60 Hz only 1.50 18.20 17.13 13.50 16.90.32 1.00 28.60 14.50 Table 3: Factory Available Options for Standard 9070 SK Units (Enclosure G4) 2.40 Primary fuse block 5-inch x 13/16-inch Two duplex receptacles, door-mounted, with strain relief F30 G16 P2 7

NEMA 1 Transformer Disconnects Mini NEMA 1 Offering (G0) G0 100 500 VA block requires: 1-1/2-inch x 13/32-inch rejection-style primary fuses Conveniently located 1/2-inch to 3/4-inch knockouts External mounting flanges with slotted holes for hook and hang mounting 11.30 10.30 2.00 2.65 ON 7.00 OFF 1/2 3/4-inch Knockouts 90 15.25 7.81 2.09 1/2 3/4-inch Conduit Table 4: Factory Available Options for Mini 9070 SK Units (Enclosure G0) 8 2003 2005 Schneider Electric All Rights Reserved 04/2005

NEMA 1 Transformer Disconnects New Compact NEMA 1 Offering (G3) 750 3000 VA G3 block requires: 1-1/2-inch x 13/32-inch rejection-style primary fuses (750 1000 VA) 5-inch x 13/16-inch rejection-style primary fuses (1500 3000 VA) Conveniently located 1/2-inch to 3/4-inch knockouts External mounting flanges with slotted holes for hook and hang mounting designed to be installed in standard 12-inch control panel 14.80 13.80 1.70 10.00 13.40 1.00 21.06 10.21 2.09 Table 5: Factory Available Options for Compact 9070 SK Units (Enclosure G3) Two duplex receptacles, door-mounted, with strain relief G16 P2 9

NEMA 12 Transformer Disconnects NEMA 12 TRANSFORMER DISCONNECTS Standard NEMA 12 Offering (A2) 250 3000 VA A2 block requires: 1-1/2-inch x 13/32-inch rejection-style primary fuses Table 6: Factory Available Options NEMA 12 (Enclosure A2) 55 C rise transformer C ** Primary fuse block 5-inch x 13/16-inch F30 Two duplex receptacles, door-mounted G16 Convert to NEMA 3R enclosure N3, with strain relief P2 ** Not available on 3000 VA 10 2003 2005 Schneider Electric All Rights Reserved 04/2005

NEMA 12 Transformer Disconnects New NEMA 12 Offering (A3) Door and handle can be locked with one lock 250 2000 VA A3 Square D disconnect switch (TCN30) 30 A, 600 V, 100,000 AIC rating when protected with block requires: 250 1000 VA: 1-1/2-inch x 13/32-inch rejection style primary fuses 1500 2000 VA: 5-inch x 13/16-inch rejection style fuses Table 7: Factory Available Options NEMA 12 (Enclosure A3) Primary fuse block 1-1/2-inch x 13/32-inch Convert to NEMA 3R enclosure F32 N3 11

Technical Information TECHNICAL INFORMATION Table 8: Primary Fusing To Meet NEC Code VA Primary Current Amperes 120 Volts 240 Volts 480 Volts 600 Volts Rating w/ Rating w/o Primary Current Amperes Rating w/ Rating w/o Primary Current Amperes Rating w/ Rating w/o Primary Current Amperes Rating w/ Rating w/o 25 0.21 1/2 1/2 0.10 1/4 1/4 0.05 1/8 1/3 0.04 1/10 1/10 50 0.41 1 1 0.21 1/2 1/2 0.10 2/10 2/10 0.05 2/10 2/10 75 0.63 1-1/2 1-1/2 0.31 6/10 6/10 0.15 3/10 3/10 0.13 3/10 3/10 100 0.83 2 2 0.42 1 1 1.21 1/2 1/2 0.17 4/10 4/10 150 1.25 3 3 0.63 1-1/2 1-1/2 0.31 6/10 6/10 0.25 6/10 6/10 200 1.67 4 4 0.83 2 2 0.42 1 1 0.33 8/10 8/10 250 2.06 5 3-2/10 1.04 2-1/2 2-1/2 0.52 1-1/2 1-1/4 0.42 1 1 300 2.50 6-1/4 4 1.25 3 3 0.63 2 1-1/2 0.50 1-1/3 1-1/3 350 2.92 7 4-1/2 1.45 3-1/2 3-1/2 0.73 2-1/2 1-8/10 0.56 1-4/10 1-4/10 500 4.17 10 5-1/4 2.03 5 3-2/10 1.04 3 2-1/2 0.83 2 2 750 6.25 15 10 3.13 7-1/2 5 1.55 3-1/2 3-1/2 1.25 3 3 1000 6.33 20 12 4.17 10 6-1/4 2.05 5 3-2/10 1.67 4 4 1500 12.50 N/A 15 6.25 15 10 3.13 7-1/2 5 2.50 6-1/4 4 2000 13.66 N/A 20 8.33 20 12 4.17 10 6-1/4 3.33 8 5 3000 N/A N/A N/A 12.50 N/A 15 6.25 15 10 5.00 12 6.25 5000 N/A N/A N/A N/A N/A N/A 10.42 25 15 8.33 20 12 Notes: 1 Recommended fuse sizes per NEC article 450-3. 2 Transformers with primary only, select protection at 125%. If standard size rating is not available, select next higher rating. 3 Transformers with primary only and current rating less than 9 A, select protection less than 167%. 4 5 Transformers with primary only and current rating less than 2 A, select protection less than 300%. Transformers with primary and secondary, select primary protection at no more than 250% and secondary at 125%. If a standard size rating is not available, go to next higher rating. Table 9: Sizing, Description, and Catalog Number (by Manufacturer) Size 1-1/2 x 13/52-inch Midget Description Time Delay, Rejection-Type, Class CC FNQ-R LP-CC Manufacturer Bussman Littlefuse Gould-Shawmut KLMR KLDR ATDR ATQR ATMR 1-1/2 x 13/52-inch Midget Time Delay FNM, FNQ FLQ, FLM, FLA ATQ, TRM, QM 1-1/4 x 1/4-inch Time Delay TDC-11, MDL, MDQ, MDA 3AG, 313/315, 3AB, 323/325 GDL 5 x 13/16-inch Time Delay FRS-R FLSR TRS 3 x 3/4-inch On Time NON NLN OT Notes: 1 These fuses are not supplied by Schneider Electric/Square D. 2 This table is provided for primary fusing recommendation only. fusing must be specified by the customer. 3 All primary fuse options offered by Schneider Electric/Square D require rejection-type fuses. 17