Ampgard medium voltage motor control renewal parts

Similar documents
Ampgard The name motor applications rely on

Instructions for AMPGARD 400A medium voltage starter

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Cutler-Hammer. AMPGARD MV Motor Control Vacuum Break SJ Series II II. Renewal Parts. r II li I. Pages. Contents. Effective: March 2000 Page 1

CR193 B,C,D and E Vacuum Limitamp * Contactors

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

A200 NEMA Contactors and Starters A200

Auxiliary Contact Rating Induction Motor 1750 HP 2250 HP 3000 HP 4500 HP Voltage (Max)

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

T300MVi JK OEM POWER CELLS MEDIUM VOLTAGE VACUUM CONTACTOR. Reliability in motion. Reliability in motion

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Medium Voltage Metal-Enclosed Switches

TABLE I. AMPGARD EQUIPMENT RATINGS

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Medium Voltage Metal-Enclosed Switches

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

NEMA Vacuum Break Contactors and Starters

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Switches Unlimited Phone: * Fax:

Metal-enclosed medium-voltage power factor correction system

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Page 2-4 Page 2-8. Page Page 2-13

Single-phase pad-mounted step voltage regulator

C1000 Series Automatic Cap Bank

Compact Circuit Protector (CCP)

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Air-insulated switchgear UniGear type ZS1

Description. Positive safety relays

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Quick selector reference guide. Motor Control Center Aftermarket Buckets

JOSLYN CLARK VACUUM CONTACTOR FEATURES

JOSLYN CLARK VACUUM CONTACTORS

Vacuum Contactors and Starters

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Application Description

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Submersible Vacuum Fault Interrupters

Metal-enclosed medium voltage power factor correction system

smissline Description

Reduced Voltage Motor Starters

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

Multi-Pak Group Control

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Industry s most comprehensive medium voltage circuit protection

Modular integrated transportable substation (MITS)

SDS Enclosed Star-Delta Starter User Guide

Bolted contact switches. Pringle switches

Instructions for Replacing

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors

SECTION 16349X MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

3. Coils shall be of molded construction

Open Chassis Star-Delta Starter User Guide

Components for EEx e Panels

CM52 Network protector

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Powering business worldwide

Compact Circuit Protector

Technical Information

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Instruction sheet WARNING. October, 2014

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Horizontal Circuit Switchers

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

CP Automatic capacitor bank

Thermal Overload Relays

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

Definite purpose contactors

Medium Voltage 400A Contactor - Series E and F Allen-Bradley Parts

Electric vehicle auxiliary fuses 500 Vdc, A

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

ABB s new control and protection devices

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Digitrip Retrofit System for BBC LKD 8 Breakers

PowerPact B. Molded case circuit breakers and switches from A

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Enclosures. See Section Typical Description

Short form catalogue. Motor protection & control

Ktec Contactors and thermal overloads

Transcription:

Technical Data TD020001EN Contents Description Page General information.... 2 3 400A starter design.... 4 9 800A starter design.... 10 15 Control and potential transformers.... 16 Current transformers.... 17 Fuses.... 18 21 Solid-state reduced voltage.... 22 24

Technical Data TD020001EN General Information Ampgard renewal and replacement parts The present design of AmpgardT medium voltage starters was introduced in 2005. Additional ratings and features have been continuously introduced over the years. This renewal parts guide will provide the proper identification of standard parts which may be required for the repair or maintenance of Eaton Ampgard starters. s identified in this document may not be the same as style numbers on the original equipment. The renewal part styles in this document may be in a kit form and include subassembly, carton, installation instructions, etc. Identifying your equipment The following can help you in identifying which version of Ampgard you have. The current version of Ampgard as shown in the bottom illustration on page 3, has the low voltage door/compartment located on the front of the medium voltage unit in a separate isolated compartment. In addition, the non-load break switch (isolation switch) is located to the right of the low voltage compartment. The previous style of Ampgard, referred to as Classic Ampgard, has the low voltage compartment to the right of the medium voltage compartment as shown in the top illustration on page 3. The isolation switch is located on the top of the medium voltage compartment. This document addresses the current generation of Ampgard. For earlier designs, please contact your local Eaton representative. There are numerous variations in Ampgard starters. Most of the parts listed in this guide are included in the more common variations. 400A starters are available with contactors that use bolted or finger connections. Fuses may be clip-in or bolt-in. Contactors are modified for high-altitude (above 2000m). There are many variations of phase barriers. Common reasons for these variations include the use of special current transformers or other optional equipment, or special provisions for customer cable connections. Dimensions are shown for each of the barriers offered in this guide. Insure that the replacement barriers match the size of those originally supplied. If the original barriers are of a different size, contact Eaton for identification of the correct replacement part numbers. 800A contactors were the SJ series through March 2014. The contactors were changed to the SL series beginning April 2014. The specific parts used in the two contactors are different, but the complete contactor assemblies are interchangeable. Parts detailed in this document will specify if they are for the SJ version or the SL version of the contactor. Replacement vacuum interrupters are not available for the SJ version. Complete replacement contactors will be the SL series only. Additional service Should you experience difficulty in determining needed parts for repair or determining existing starter condition, contact your local Eaton representative. We can provide qualified technical personnel on site to: Identify and recommend replacement parts for damage caused by short-circuit of fault Remove damaged parts and install replacements Retrofit vintage motor-starting equipment with new components Evaluate condition of existing equipment Test components Provide a recommended spare parts list Upgrade horsepower rating 2

Technical Data TD020001EN Isolation switch 400A starter LV compartment Figure 1. Classic Ampgard 400A starter 800A starter LV compartment Isolation switch Figure 2. Current Ampgard (covered in this guide) 3

Technical Data TD020001EN 400A starter design Bolted connection Figure 4. 400A contactor with bolted connection Finger connection Figure 5. 400A contactor with finger connection Vacuum interrupters Control board Auxiliary contacts Figure 6. 400A contactor (bottom view) Figure 3. 7.2 kv, 400A, 2-high 4

Technical Data TD020001EN Table 1. 400A contactors (7.2 kv and below) Figure 7. Stab connection Figure 8. Bolted connection 400A bolt-in main contactor (120 Vac, 130 ms dropout a) b 400A stab-in main contactor (120 Vac, 130 ms dropout a) b 400A bolt-in reversing contactor (120 Vac, 130 ms dropout a) b 400A stab-in reversing contactor (120 Vac, 130 ms dropout a) b 400A bolt-in latched contactor (120 Vac close and trip) b 400A stab-in latched contactor (120 Vac close and trip) b a Dropout time is field adjustable. b Standard altitude contactor. For high altitude applications (>2000m) contact factory. SL72B4SH3LANL7MNR25 SL72S4SH3LANL7MNR25 SL72B4SH3LANL7VNR25 SL72S4SH3LANL7VNR25 SL72B4SH3LAL45MNR25 SL72S4SH3LAL45MNR25 5

Technical Data TD020001EN Table 2. 400A lower fuse phase barriers single barrel fuse (qty. 4) Table 5. 400A motor load phase barriers (qty. 4) 5.50 (139.7) 9.25 (235.0) 12.25 (311.2) 5.10 (129.5) 400A 54A1310G02 Table 3. 400A fuse phase barriers double barrel fuse (qty. 4) 400A 54A1310G01 8.20 (208.3) Table 6. 400A isolation switch barrier double barrel (qty. 4) 9.25 (235.0) 6.80 (172.7) 8.40 (213.4) 400A 54A1310G05 Table 4. 400A contactor load stab barriers (qty. 4) 400A 54A1300G20 4.40 (111.8) 4.90 (124.5) 400A 54A1302G20 6

Technical Data TD020001EN Table 7. 400A contactor line stab and lower fuse-mount assembly for bolt-in contactor Table 10. 400A contactor line stab and lower fuse-mount assembly for stab-in contactor Bolt-in fuse 54A1301G03 (order barriers separately) Bolt-in fuse Clip-in fuse 54A1301G01 (order barriers separately) 54A1301G02 (order barriers separately) Clip-in fuse 54A1301G04 (order barriers separately) Table 8. 400A contactor load stab assembly for bolt-in contactor Table 11. 400A contactor load stab assembly for stab-in contactor 400A SL 54A1302G01 (order barriers separately) 400A SL 54A1302G02 (order barriers separately) Table 9. 400A motor load connection assembly (T1, T2, T3) 400A load 54A1306G01 (order barriers separately) 7

Technical Data TD020001EN Table 12. 400A vacuum bottle assembly (qty. 3) Table 15. 400A control circuit board (includes mounting bracket and hardware) 400A SL 2147A58G02 400A SL 2147A58G03 Table 13. Auxiliary contact assembly (2NO/2NC) Table 16. 400A dual coil kit 400A SL 2147A58G04 400A SL 2147A58G11 Table 14. 400A contactor mechanical interlock kit Table 17. 400A mechanical latch assembly Main Reversing Run or start 87C0600G01 87C0600G02 87C0600G03 24 Vdc coil and diode 2147A58G25 48 Vdc coil and diode 2147A58G26 125 Vac/Vdc coil and diode 2147A58G27 250 Vac/Vdc coil and diode 2147A58G28 Mechanical assembly 2147A58G24 8

Technical Data TD020001EN Table 18. 400A isolation switch fixed portion Table 20. 400A isolation switch removable portion Isolation switch fixed portion 54A1300G01 Table 19. Handle mechanism (contact factory for kirk key option) Bolt-in fuse Bolt-in fuse with blown fuse bar Clip-in fuse 54A1300G02 (order barriers for double barrel fuses separately) 54A1300G03 (order barriers for double barrel fuses separately) 54A1300G04 (order barriers for double barrel fuses separately) 400A full voltage 400A reduced voltage (with two door interlock pins) 54A1305G01 54A1305G02 9

Technical Data TD020001EN 800A starter design L64 auxiliary contacts L63 contact (economizing) Figure 10. 800A SJ series contactor (front view) Vacuum interrupters Figure 11. 800A SJ series contactor (rear view) Figure 9. 7.2 kv 800A Figure 12. 800A SL series contactor (front view) 10

Technical Data TD020001EN Table 21. 800A SL series complete replacement contactors 800A SL series standard stab-in contactor (120 Vac, 130 ms dropout, interchangeable with SJ series) 800A SL series reversing stab-in contactor (120 Vac, 130 ms dropout, interchangeable with SJ series) 800A SL series latching stab-in contactor (120 Vac close and trip, interchangeable with SJ series) SL72S8SH3LANL7MNR25 SL72S8SH3LANL7VNR25 SL72S8SH3LAL45MNR25 11

Technical Data TD020001EN Table 22. 800A lower fuse phase barriers (qty. 4) Table 25. 800A motor load phase barriers (qty. 4) 8.20 (208.3) 9.25 (235.0) 12.50 (317.5) 800A 54A1310G07 5.10 (129.5) Table 23. 800A isolation switch barriers (qty. 4) 800A 54A1310G01 6.80 (172.7) Table 26. 800A contactor load stab phase barriers (qty. 4) 8.40 (213.4) 5.40 (137.2) 7.50 (190.5) 800A 54A1300G20 Table 24. 800A motor load connection assembly (T1, T2, T3) 800A 54A1302G21 Table 27. 800A contactor load stab assembly 800A SL 87C0599G01 (order barriers separately) 800A SL 87C0598G07 (order barriers separately) 12

Technical Data TD020001EN Table 28. 800A contactor line stab and lower fuse-mount assembly Table 31. 800A SJ series L-64 auxiliary interlocks 1NO/1NC 2NO 2NC 843D943G21 843D943G22 843D943G23 800A SL 87C0597G05 (order barriers separately) Table 32. 800A SJ series contactor dual main coil assembly Table 29. 800A SJ series magnetic assembly (complete with coil and springs) 120 Vac 2147A88G11 240 Vac 2147A88G12 Table 33. 800A contactor mechanical interlock kit (SJ or SL) 120 Vac 2147A88G02 240 Vac 2147A88G03 Without coil 2147A88G04 Table 30. 800A SJ series L-63 interlock (coil circuit) Interlock kit 87C0726G01 Interlock 578D461G03 13

Technical Data TD020001EN Table 34. 800A SL series main coil Table 37. 800A SL series auxiliary interlocks 2NO/2NC 54A1307G22 Coil 54A1307G18 Table 38. 800A SL series vacuum bottle assembly (qty. 3) Table 35. 800A SL series control circuit board 800A SL 54A1307G19 800A SL 54A1307G24 Table 39. 800A SL series load finger assembly (qty. 3) Table 36. 800A SL series line finger assembly (qty. 3) 800A SL 54A1307G13 800A SL 54A1307G20 14

Technical Data TD020001EN Table 40. 800A isolation switch removable portion (blown fuse indicator (BFI) optional) Table 42. Handle mechanism (contact factory for kirk key option) 800A full voltage 54A1305G05 Without BFI With BFI 54A1300G12 (order barriers separately) 54A1300G13 (order barriers separately) Table 41. 800A isolation switch fixed portion Fixed portion 54A1300G11 15

Technical Data TD020001EN Control and potential transformers Table 43. Standard 750 VA control transformer, 60 Hz Table 46. 2 kva control transformer, 60 Hz 2300/120V C7.5A1D1F2 4160/120V C7.5E1D1F2 2300/120V C20A1D1F2 4160/120V C20E1D1F2 Table 47. Ground fault current transformer Table 44. Potential transformer 100 VA three-phase, 60 Hz, open delta 2400/120V PT3A0F6 4200/120V PT3E0F6 Table 45. Vacuum interrupter wear gauge 50/5 ratio 54A1314G02 400A (.020) 800A (.060) 5259C11H01 5259C11H02 16

Technical Data TD020001EN Current transformers Table 48. Current transformers three-phase donut type with leads Table 49. Current transformers single-phase donut type (qty. 3) Ratio 100/5 54A1303G01 150/5 54A1303G02 200/5 54A1303G03 250/5 54A1303G04 300/5 54A1303G05 400/5 54A1303G06 500/5 54A1303G07 600/5 54A1303G08 800/5 54A1303G09 1000/5 54A1303G10 Ratio 50/5 a 75/5 b 100/5 2147A13G04 150/5 2147A13G05 200/5 2147A13G06 250/5 2147A13G07 300/5 2147A13G08 400/5 2147A13G09 500/5 2147A13G10 600/5 2147A13G11 750/5 2147A13G12 800/5 2147A13G13 1000/5 2147A13G14 1200/5 2147A13G15 a Use style number 2147A13G04 and double loop primary leads. b Use style number 2147A13G05 and double loop primary leads. 17

Technical Data TD020001EN Fuses Table 50. Clip-in fuses, 5.0 kv maximum (qty. 3) Rating CLS 400A motor starter 30A 1R 2A98253G01 70A 2R 2A98253G02 100A 3R 2A98253G03 130A 4R 2A98253G04 150A 5R 2A98253G05 170A 6R 2A98253G06 200A 9R 2A98253G07 230A 12R 2A98253G08 390A 18R a 2A98253G09 450A 24R a 2A98253G10 HLE 400A feeder starter 10E 2A98253G41 15E 2A98253G42 20E 2A98253G43 25E 2A98253G44 30E 2A98253G45 40E 2A98253G46 50E 2A98253G47 65E 2A98253G48 80E 2A98253G49 100E 2A98253G50 125E 2A98253G51 150E 2A98253G52 200E 2A98253G53 250E 2A98253G55 300E a 2A98253G56 350E a 2A98253G57 400E a 2A98253G58 450E a 2A98253G59 a Double barrel. 18

Technical Data TD020001EN Table 51. Clip-in fuses, 7.2/8.3 kv maximum (qty. 3) Rating CLS 400A motor starter 70A 2R 2A98253G21 100A 3R 2A98253G22 130A 4R 2A98253G23 150A 5R 2A98253G24 170A 6R 2A98253G25 200A 9R 2A98253G26 230A 12R 2A98253G27 390A 18R a 2A98253G28 450A 24R a 2A98253G29 HLE 400A feeder starter 10E 2A98253G71 15E 2A98253G72 20E 2A98253G73 25E 2A98253G74 30E 2A98253G75 40E 2A98253G76 50E 2A98253G77 65E 2A98253G78 80E 2A98253G79 100E 2A98253G80 125E 2A98253G81 150E 2A98253G82 175E 2A98253G83 200E a 2A98253G84 250E a 2A98253G85 300E a 2A98253G86 350E a 2A98253G87 a Double barrel. 19

Technical Data TD020001EN Table 52. Bolt-in fuses, 5.0 kv maximum (qty. 3) Rating CLS 400/800A motor starter 30A 1R 54A1311G11 70A 2R 54A1311G12 100A 3R 54A1311G13 130A 4R 54A1311G14 150A 5R 54A1311G15 170A 6R 54A1311G16 200A 9R 54A1311G17 230A 12R 54A1311G18 390A 18R a 54A1311G19 450A 24R a 54A1311G20 CLS 800A motor starter 650A 36R a 54A1311G21 800A 44R a 54A1311G22 HLE 400/800A feeder starter 15E 54A1311G41 20E 54A1311G42 25E 54A1311G43 30E 54A1311G44 40E 54A1311G45 50E 54A1311G46 65E 54A1311G47 80E 54A1311G48 100E 54A1311G49 125E 54A1311G50 150E 54A1311G51 175E 54A1311G52 200E 54A1311G53 250E 54A1311G54 300E a 54A1311G55 350E a 54A1311G56 400E a 54A1311G57 450E a 54A1311G58 HLE 800A feeder starter 600E a 54A1311G59 750E a 54A1311G60 a Double barrel. 20

Technical Data TD020001EN Table 53. Bolt-in fuses, 7.2/8.3 kv maximum (qty. 3) Rating CLS 400/800A motor starter 100A 3R 54A1312G11 130A 4R 54A1312G12 150A 5R 54A1312G13 170A 6R 54A1312G14 200A 9R 54A1312G15 230A 12R 54A1312G16 390A 18R a 54A1312G17 450A 24R a 54A1312G18 HLE 400/800A feeder starter 15E 54A1312G35 20E 54A1312G36 25E 54A1312G37 30E 54A1312G38 40E 54A1312G39 50E 54A1312G40 65E 54A1312G41 80E 54A1312G42 100E 54A1312G43 125E 54A1312G44 150E 54A1312G45 180E 54A1312G46 200E a 54A1312G47 250E a 54A1312G48 300E a 54A1312G49 350E a 54A1312G50 a Double barrel. 21

Technical Data TD020001EN Solid-state reduced voltage 400A MV4S reduced voltage solid-state Digital control unit 54A1318G01 Figure 13. 400A MV4S starter (front view) Figure 14. 400A MV4S starter (doors open) 22

Technical Data TD020001EN Table 54. 400A MV4S solid-state truck assembly Table 55. 400A MV4S control door and control compartment Communications harness Communications harness 54A1318G31 Complete truck assembly 400A/4160V 400A/2300V 400A/3300V 200A/4160V 200A/2300V 200A/3300V Bypass contactor VI assembly (includes line side fingers) Bypass contactor complete Bypass contactor load finger assembly Power pole assembly (single-phase) 400A/4160V 400A/2300V 200A/4160V 200A/2300V Temperature board 54A1320G01 54A1320G02 54A1320G03 54A1320G04 54A1320G05 54A1320G06 54A1307G17 54A1319G01 54A1307G16 54A1318G200 54A1318G201 54A1318G300 54A1318G301 54A1318G09 23

Technical Data TD020001EN Table 56. 400A MV4S control compartment Transformer 54A1318G04 CPU and MCB 54A1318G02 CT board 54A1318G08 CT harness 54A1318G42 TCB board 54A1318G03 Fiber optics Fiber optics 4160V 2300V XP3 4160V 2300V 54A1318G22 54A1318G23 54A1318G24 54A1318G25 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2014 Eaton All Rights Reserved Printed in USA Publication No. TD020001EN / BC-201 October 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.