Installation Instructions F-440N. Model No. F F F F F F F /16 157mm. Inline.

Similar documents
Distributed by: M&M Control Service, Inc Installation Instructions F-440N

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

DIGIFLO ELECTRONIC FLOWMETER

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

F300 - PITOT TUBE ACRYLIC FLOWMETERS

CHEM-FEED. Engineered Skid Systems. ProSeries. by Blue-White Ind.

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

KOBOLD KSK FLOWMETER. User Instructions

7430 Series Hastelloy / Monel / Stainless Steel Installation Instructions

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

UNIVERSAL. Flow Monitors Inc. INSITE Series PX - IS - TX Flow Rate Indicators and Switches

Chem-Feed Installation Instructions

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

DAKOTA INSTRUMENTS OPERATING MANUAL ACR ACRYLIC FLOW METERS

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Full View Flow Indicator

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

KOBOLD DF-MA Flow Transmitter. User Instructions

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

KOBOLD DF-WM Flow Monitor. User Instructions

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

Camlocks. Snaplock Camlock Couplings. The original Snaplock quick release coupling. Applications

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

PVDF TURBINE HOUSING

Page 1 of 12. Part# /30/2016

INSTALLATION AND OPERATION

100 Series Flow Switches Technical Reference Manual

200 Series Flow Meters

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

PORTER FLOWMETERS & FLOW CONTROLLERS. Technology you can trust

CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

KOBOLD DAA FLOW INDICATOR. User Instructions. DAA_manual_12-13

SERIES 8100 HAND-OPERATED PRESSURE CALIBRATION UNITS

EZ-View. Flow Meters ISO CERTIFIED 9001

Thank You. for purchasing an Edelbrock Nitrous Oxide Injection System. Please take the time to read and understand the following.

Operating Instructions for Plastic Flow Meter. Model: KSK

PULSATION DAMPENERS OPERATION & MAINTENANCE MANUAL

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

S P R AY E R VA L V E S AND C O N T ROL S C AT A L OG

See Installation Guide

Thermoplastic. Order Online. Specialists in. Since Piping systems. fwwebb.com/plastics Flowmeters & Process Control.

PVDF TURBINE HOUSING

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Natural Gas Manifolds M6A, M6T, M6TA 5-Valve Manifolds

KDG/KDF - Flow Meter and Flow Switch

Owner s Manual FS-10/FreshSpa

CONTACTING CONDUCTIVITY GENERAL PURPOSE SENSORS Instruction Manual

SETRA Operating Instructions Series DPT 230 Pressure Transducers

SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

150 PSI ILLUMINATED DASH PANEL GAUGE KIT

Data Sheet 11.1 Issue A

Table of Contents. Page. See Catalog and Product Updates on our Website

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

King Instrument Company opened its doors in 1983 with one major goal:

Intended Use: Explanation of Signal Word Consequences

Installation & Operator s Manual

Glass Tube Full-View Flowmeters

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD. Operator s Manual and Installation Instructions

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

OMP Positive Displacement Flowmeters

PP1 Series Piping Packages for VG1000 Series Ball Valves

Positive Displacement Flowmeters GM020 series instruction manual

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

Owner s Manual WARNING

SAFETY INFORMATION & INSTRUCTION MANUAL

DIAPHRAGM METERING PUMPS

General Design Features

Innovative and reliable coupling designs for over twenty years. Coupling body. Coupling insert

8700 Series 8900 Series Rolling Air Jacks

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

ONBOARD AIR HOOKUP KIT

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

Iron Gate Air Pump System Manual

SOLUTION STATION Instruction Manual

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD CTD-310-K. Operator s Manual and Installation Instructions

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

SAVE FOR CONSUMER INSTALLATION / OWNER S MANUAL. Includes: Tools: Mystic - Pull-Out Kitchen Faucet LKMY1041CR LKMY1041NK LKLFMY1041CR LKLFMY1041NK D 1

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Installation Instructions

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

EBS PRODUCTS

Single Pump Station with Delay, 10HP/1PH DU PS2001C-PG

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

MULTIPOSITION AIR CYLINDER

MODEL 5120 Tire Repair Station

Distributed by: M&M Control Service, Inc

High Pressure Equipment High Pressure Valves, Fittings and Tubing

Corrosion Coupon Rack Operations & Maintenance Manual

PRODUCT IDENTIFICATION & COMPANY

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Transcription:

F-0N B A F-0NE B Installation Instructions F-0N C D A Model No. F-0 F-0 F- F- F-00 F-0 F-0 Inline Elbow Adjustable F-0E F-0E F-E F-E F-00E F-0E F-0E F-0EA F-0EA F-EA F-EA F-00EA F-0EA F-0EA Dim A Dim B Dim C Dim D -/ mm -/ 9mm 8mm 8mm 8-/8 0mm 8mm 8 /8 0mm -/ mm mm ½ mm ½ mm /8 mm mm mm N/A N/A -/ mm mm mm -/ mm mm N/A N/A mm -/ mm -/ mm -/ mm -/ mm F-0NEA B C Meter Body: Polysulfone Float: SS, Hastelloy C-, PVDF, or Teflon (based on model) Guide rod: # Stainless (opt. Hastelloy C-) Adapters: Polysulfone O-Rings: Viton (optional EP) Scale: Permanent, dual scale silkscreen (black ink) Max. PSIg: PSIG / BAR at 0 F/ C Max. Temp: F / 00 C at 0 pressure Accuracy: ± % of full scale reading A D Your Blue-White F-0 Series Your Blue-White flowmeter was designed to be easy to install. Please read the Instruction Guideline on the next page before installing your flowmeter. This flowmeter is an instrument, special care should be taken when handling and installing. Inspection of the Flowmeter and Compatibility Carefully inspect the meter for any damage that may have occurred during shipping. Remove the plastic tubing that has been inserted during packaging for shipping reasons. Make sure your pressure, temperature, fluid and other requirements are compatible with the meter before installation. The maximum temperature capability decreases as the pressure increases. The max PSI decreases as the temperature increases. See the chart on the following page. Although the meter may be suitable for other chemicals, Blue-White meters are tested with water. If you are unsure of the meters compatibility with your chemical, please consult the factory. Blue-White warranties the flowmeter for use with air and water only. R Blue-White Industries, Ltd. 80000-0 00009

Caution: Follow these instructions to avoid failure. Installation Guideline Ceiling Danger: Wear eye protection when installing or removing flowmeter.. Misalignment will damage the meter! Flowmeter must be installed in an exact vertical plane to ensure accuracy. Be certain of proper plumbing alignments. Misalignment may cause the o-ring seals to leak. The meterbody material can be damaged by UV rays. Do not install in direct sunlight.. Pipe dope and glue will damage the meter! Use only Teflon tape on the threaded adapters. Polysulfone meter body and fittings cannot tolerate PVC Glue and/or pipe dope. Even fumes can cause severe damage. If you are installing your flowmeter to a glued pipe configuration, install the flowmeter Floor after all glued fittings are dried and lines are purged of all fumes. Never hold the meter body with pliers or like tools. Union nuts should be hand tightened only. DO NOT OVER-TIGHTEN!. Vibration and heavy loads will damage the meter! Wall, floor and ceiling mounts and supports must be carefully aligned with the meter body and sturdy enough to support the plumbing and prevent vibration. Never allow the flowmeter to support the weight of related piping.. Solenoid valves will damage the meter! Avoid a system that will impose a sudden burst of flow to the meter. Such a burst will cause the float to impact the float stop with destructive force. Solenoid valves, or other quick opening valves cannot be used unless meter is protected against sudden bursts of flow.. High pressures and temperatures will damage the meter! The maximum acceptable temperature and pressure is interdependent. The maximum acceptable working pressure is dependant on the actual fluid temperature. The maximum acceptable fluid temperature is dependant on the actual working pressure. (see Temperature Vs. Pressure chart).

Temperature Temperature vs. Pressure F/00 C 90 F/8. C 0 F/. C 0 F/. C 0 F/. C 0 F/. C 90 F/. C 0 F/. C 0 psi 0 bar 0 psi. bar 0 psi.bar 90 psi. bar 0 psi 8. bar 0 psi 0. bar psi bar Pressure and Temperature Pressure and temperature limits are inversely proportional. At the maximum suggested pressure the temperature should approach 0 F /. C; at the maximum suggested temperature the pressure should approach zero psi. We cannot guarantee our flowmeters will not be damaged either at or below the suggested limits simply because of many factors which influence meter integrity; stress resulting from meter misalignment, damage due to excessive vibration and/or deterioration caused by contact with certain chemicals as well as direct sunlight. These situations and others tend to reduce the strength of the materials from which the meters are manufactured. Application Note Flowmeters are tested and calibrated for water or air only. Although meters may be suitable for other chemicals, Blue-White cannot guarantee their suitability. It is the responsibility of the user to determine the suitability of the flowmeter in their application. Maintenance The Exploded View drawing illustrates assembly of the F-0 series meter. If your flowmeter needs to be cleaned refer to this drawing when reassembling the unit. The tapered tube may be cleaned with a soft bottle brush. Use a MILD soap and water solution for cleaning purposes. Hard water deposits can be removed with a % acetic acid solution (vinegar). Note the floats up position. R Blue-White Industries, Ltd.

F-0 - In-Line No. Part No. Desc. F-N0 /8 Male NPT in-line adapter, Polysulfone F-N08 / Male NPT in-line, Polysulfone F-N / Male NPT in-line, Brass F-N / SWEAT in-line, Brass F-N09 / Male NPT in-line, Polysulfone F-N / Male NPT in-line, Brass F-N / SWEAT in-line, Brass F-N0 /8 Male NPT in-line,polysulfone, large body F-N0 ½ Male NPT in-line, Polysulfone, large body F-N0 /8 and / Half Union, Nylon F-N0AL /8 and / Half Union, Aluminum F-N0 / Half Union, Nylon F-N0AL / Half Union, Aluminum 9000- /8 and / O-ring seal, Viton 9000- /8 and / O-ring seal, EP 9000-08 / O-ring seal, Viton 9000-09 / O-ring seal, EP N/A Meterbody and Float not sold separately F-N /8 and / Guide Rod, Stainless Steel F-N / Guide Rod, Stainless Steel F-NH /8 and / Guide Rode, Hastelloy C- F-NH / Guide Rod, Hastelloy C- F-N00 /8 and ½ Guide Rod holder, Polysulfone F-N09 / Guide Rod holder, Polysulfone F-N0 Indicator, Red

F-0E - Elbow (Panel Mount) No. Part No. Desc. F-N0 /8 Male NPT 90 Elbow, Polysulfone F-N0 / Male NPT 90 Elbow, Polysulfone F-N / Male NPT 90 Elbow, Polysulfone F-N0 /8 and / Half Union, Nylon F-N0 / Half Union, Nylon F-A /8 and / Panel mount lock nut F-8A / Panel mount lock nut 9000- /8 and / O-ring seal, Viton 9000- /8 and / O-ring seal, EP 9000-08 / O-ring seal, Viton 9000-09 / O-ring seal, EP N/A Meterbody and Float not sold separately F-N /8 & / Guide Rod, SS F-N / Guide, SS F-NH /8 & / Guide Rod, Hastelloy C- F-NH / Guide Rod, Hastelloy C- F-N00 /8 and / Guide Rod holder, Polysulfone F-N09 / Guide Rod holder, Polysulfone F-N0 Indicator, Red

F-0A - Adjustable (Panel Mount) 8 0 9

F-0A - Adjustable (Panel Mount) No. 8 9 0 Part No. Desc. F-N0 /8 Male NPT 90 Elbow, Polysulfone F-N0 / Male NPT 90 Elbow, Polysulfone F-N / Male NPT 90 Elbow, Polysulfone F-N0 /8 and / Half Union, Nylon F-N0 / Half Union, Nylon F-A /8 and / Panel mount lock nut F-8A / Panel mount lock nut 9000- /8 and ½ O-ring seal, Viton 9000- /8 and ½ O-ring seal, EP 9000-08 / O-ring seal, Viton 9000-09 / O-ring seal, EP N/A Meter body and Float not sold separately F-N /8 & / Guide Rod, SS F-N / Guide, SS F-NH /8 & / Guide Rod, Hastelloy C- F-NH / Guide Rod, Hastelloy C- F-N09 / Guide Rod holder, Polysulfone F-N00 /8 and ½ Guide Rod holder, polysulfone F-N0- /8 M/NPT Valve Assm. Sm, Poly, Viton seal F-N0- ½ M/NPT Valve Assm. Sm, Poly, Viton seal F-N0- /8 M/NPT Valve Assm. large, Poly, Viton Seals F-N0- / M/NPT Valve Assm. large, Poly, Viton Seals F-N0- / M/NPT Valve Assm. large, Poly, Viton Seals 9000-00 O-ring, Viton 9000-009 O-ring, EP 9000-08 O-ring, Viton 9000-0 O-ring, EP F-N0 Indicator, Red

BLUE-WHITE INDUSTRIES LIMITED WARRANTY FLOWMETERS are warranted to be free of defects in material and workmanship for up to months from the date of factory shipment. Warranty coverage is limited to repair or replacement of the defective flowmeter only. Blue-White Industries does not assume responsibility for any other damage that may occur. This warranty does not cover damage to the flowmeter that results from misuse or alterations, nor damage that occurs as a result of: meter misalignment, improper installation, over tightening, use of non- recommended chemicals, use of non-reccomended adhesives or pipe dopes, excessive heat or pressure, or allowing the meter to support the weight of related piping. Flowmeters are tested and calibrated with water and air only. Although meters may be suitable for other chemicals, Blue-White cannot guarantee their suitability. Flowmeters are repaired at the factory only. Call or write the factory to receive a Return Authorization Number, carefully pack the flowmeter to be returned, including a brief description of the problem. Note the RA number on the outside of the carton. Website: www.blue-white.com E-mail: Sales@Blue-White.com Techsupport@Blue-White.com Phone: -89-89 Fax: -89-99 R Blue-White Industries, Ltd. 00 Business Drive Huntington Beach, CA 99