Graf Aqua Controller Programming & Setup to use with 3- way valve for backup systems

Similar documents
RS4000 Setup. Before you install the RS4000 system, check to ensure that nothing was damaged or lost during shipping.

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Tracer VM with User Interface

SKD62UA Series Electronic Valve Actuator, Advanced Features

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

Pre-plumbed Blowdown Assembly ½ Model

Inlet Controller SB3500 USER'S MANUAL

TC62D Installation Instructions

Installation and Operation

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

Quarter Master Chief Series 92 Actuator

Electric Actuator Instructions

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Installation. Part A, Section 3. This section covers the following unit configurations. Voltage 1, 2, 3. Vista Standard (V) A3EN-04-[3V-A-AAXV]-11

Mill/Drill Conversion to Three Phase and installing a VFD

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Installation Instructions

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

IRRIGATION CONTROLLER

Installation Instructions

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

BSR Magic Box Digital ignition control for 4, 6, or 8 cylinder engines

i n s t r u c t i o n m a n u a l

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Model 550 Series Vibration Switches

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

5000TOC Sensor Service Manual

DCC-2500 Digital Climate Control for Vintage Air GEN-IV systems

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

PRO REMOTE Series CAPACITANCE PROBE

Instruction Manual MINI IRRIGATION CONTROLLER.

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

LevelMaster II-C. Installation and Operational Manual. Blade control system for Grader and Dozer Applications

SmartX MF and MS

Deans Switch Microfluidics

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

GPS AutoSteer System Installation Manual

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

ON DEMAND INSTALLATION GUIDE

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

CENTRIFEEDER ELECTRONICS

SAX Electronic Valve Actuator

Dodge Ram 09-Current CS-DTR SERIES BACKUP CAMERA INSTALLATION

Transformer Installation, Operation, and Maintenance Manual

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

PIRANHA 5 INSTALLATION GUIDE

One- Touch Installation Instructions

PRODUCT INFORMATION BULLETIN

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, P/N: , Revision 1

Motorized Stainless 2-Way Valves

Application Note. Monitoring Bearing Temperature with ProPAC

WEM-MX-333mV. Integrated Meter Installation Guidelines

TV Lift System Model L-75i Installation Instructions

Vission 20/20 micro-controller. Operation and service manual

Eco-Propel TM Variable Speed Pump Kit Instruction and Operation Manual, p/n Revision 0

Self-Testing Industrial Series

AUTOMATIC SPRINKLER TIMER

ChargePoint Gateway Installation Instructions

INTRODUCTION 2EZHM DESCRIPTION

Sidel Therm & CO 2 Counter Instruction & Installation Manual

Signet Pressure Transmitter

OWNER'S MANUAL FOR 135LB STAINLESS STEEL SPREADER SNOWRATOR

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

Tracer VMA with AutoReg

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

S-2300 Pneumatic Selector Switch

INSTALLATION INSTRUCTIONS

Signet Pressure Transmitter

Signet Temperature Transmitter

SKD U Electronic Valve Actuator

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

I-BFV.KIT Butterfly Valve Gear Operator Replacement

OpenAir Electronic Damper Actuators GLB Series Enhanced Non-spring Return Rotary

INSTALLATION AND OPERATION INSTRUCTION

SKD U Electronic Valve Actuator

Cold Air Intake Installation Instructions

GPS AutoSteer System Installation Manual

mygrid Installation Notes

Accessory Fitting Instructions

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

IntelliTouch Expansion Center Kit

920i Programmable HMI Indicator/Controller Deep Enclosure Installation Instructions PNs 82455, 82456, 82457, 82458, 82459, 82460

Manifold QF. Contents. Description. Installation & Setup Guide. Safety 3. Introduction 3. Installation Standards 4. Specifications 5.

WirelessAIR Advanced Integrated Remote

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

PowerView PV380-R2 Mechanical Configuration

Transcription:

Graf Aqua Controller Programming & Setup to use with 3- way valve for backup systems

Back-up System Overview The Graf Aqua Control and Three way valve combined will automate the operation of a backup water supply in a rainwater collection system. When the level in the tank is low the valve will automatically switch to the municipal water supply. The Graf Aqua control uses an electronic level sensor and sensor control box mounted in the tank. The sensor and sensor control box detect the level of water based on the sensor length. The controller translates that signal and in turn is used to produce a graphical display of the water level from 0 to 100 %. The controller has several programmable functions based on that percentage that can then be used to provide signals to connected devices via 24vac output terminals labeled 1, 2, 3 and 4 in the controller. 2 3/27/2018 Add a footer

3 3/27/2018 Add a footer

4 3/27/2018 Add a footer

5 3/27/2018 Add a footer This is the Graf Aqua Controller Box

6 3/27/2018 Add a footer

Box contents include: Graf Aqua Controller display unit, Sensor control box, tank level sensor, transformer power supply 24VAC, and fittings/parts bag. 3-Way valve shipped separate. 7 3/27/2018 Add a footer

Sensor box wiring and installation in tank Sensor and sensor control box are installed as shown in this photo. Once wired install sensor box cover. The sensor box should be mounted a minimum of 4 inches from the highest possible water level in tank. 8 3/27/2018 Add a footer Sensor should be installed so the stainless steel sensor weight is suspended 1 inch from bottom of tank. You will need to measure the length of the wires from the sensor box to the sensor weight for control sensor calibration. (explained on slide 22)

9 3/27/2018 Add a footer

Once sensor is installed in tank the data wire (2 strand, shielded, 18 gauge, outdoor rated) should be routed to the Aqua Controller. This wire should be run to the Aqua Control unit in its own conduit. Running the data cable in another high voltage conduit can cause interference with the signal. Graf Aqua Controller should be mounted indoors or in a similar dry location. If outdoor installation is required a weather rated enclosure can be purchased from RainHarvest Systems. 10 3/27/2018 Add a footer

11 3/27/2018 Add a footer The knockouts used for wiring grommets should be scored all the way around with utility knife and remove for wiring. Then install the included grommets and tighten as shown.

The 3-way valve should be located in an upright position and in a protected enclosure not more than 150 from the controller. An 18 gauge or heavier, 3 strand SOOW (outdoor) type wire, should be used to run between the controller and the valve. Remember, the longer the distance the larger the wire. Voltage drop must be taken into consideration when sizing wire. The water tight grommets should be utilized on the valve to avoid any moisture from entering the housing. There is more than one terminal strip in the Bonomi valve. The terminal strip needed for valve turning operation is labeled F and 1 2 3. The wiring from the Aqua Control will be connected to these terminals. The other terminal strips are for signal outputs and will not be used. Tinning all wires is recommended if you have the ability to do so. 12 3/27/2018 Add a footer

Manual control knob. Valve can be rotated 360 degrees with this knob. 3-way valve plumbing Valve position pointer indicates the state of the connection directly below. In this example, the right hand side is open to the output. Either rainwater supply or municipal water supply Either rainwater supply or municipal water supply Output to irrigation system or other 13 3/27/2018 Add a footer

Making Connections Inside 3-Way-Valve Loosen (4) screws to remove 3-way valve cover Remove red dial with 2.5mm hex wrench 14 3/27/2018

Remove one of the grommet nuts and slide over the wires before inserting wires into valve Strip wires back roughly half an inch. Wire size should be 16 or 18 gauge SOOW type wire to ensure water tight seal. 15 3/27/2018 Add a footer

Pull wires through roughly 4 inches Connect black wire to terminal 1 Connect white wire to terminal 2 Connect green wire to terminal 3 16 3/27/2018 Add a footer

Tighten grommet onto black wire Use a bolt or other fitting to seal the unused side opening to prevent any moisture from getting inside 17 3/27/2018 Add a footer

Wiring Of Aqua Control Wiring power supply transformer and sensor box to Aqua Control display unit Sensor Box wiring to display unit. Easier to wire before the others 18 3/27/2018 Add a footer

3-way-valve wiring to Aqua Control display unit 3 wire connection from 3-way valve at display unit. Note: Green and black wires may need to be reversed depending on orientation of municipal and rainwater connections on 3-way valve. 19 3/27/2018 Add a footer

20 3/27/2018 Add a footer Programming Controller for use with 3-way Valve

Start-up screen Press and hold menu button for 5 seconds Use arrows to scroll to DEVICE ADJUSTMENT Press OK 21 3/27/2018 Add a footer

First setting is language, English is default, scroll to next setting, which is UNITS and default is inches. MEASURING LENGTH: Press OK and the number will flash indicating selection, enter tank sensor length taken from measuring the sensor wires in tank. Then press OK once length is correct. After setting the length and pressing OK scroll to OPERATION TERM.1 and press OK. 22 3/27/2018 Add a footer

The default setting of PUMP NO will be flashing. Using arrow keys change to BACKUP NC and press OK. Scroll to OPERATION TERM.2 where the default setting is BACKUP NC, change this to BACKUP NO, press OK. This completes the DEVICE ADJUSTMENT settings. The controller uses the BACKUP function to control the 3 way valve operation. This function has two states, BACKUP ON (which when activated, is indicated on the front of the unit by an LED located beside the spigot icon) and BACKUP OFF. The default settings for this function are on at 10% and off at 12%, but you can make these settings any logical amounts you need in the SWITCHING POINTS menu. When the level in the tank reaches 10%, the backup function is activated and will energize terminal 1 and that will cause the 3 way valve to rotate. Conversely, when the water level moves up to 12%, the backup function will turn off, terminal 2 will be energized and the valve will rotate in the opposite direction. Important note: If the BACKUP ON and BACKUP OFF percentages need to be raised it will be necessary to change the REFILL OFF setting to a number higher than what the desired BACKUP ON setting is. 23 3/27/2018 Add a footer