FlowScanner 6000 SGIM-1 and SGIM-2 Strain Gauge Interfaces

Similar documents
Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System

AMS ValveLink SNAP-ON Applications

Zero Point Calibration HART Communicating Fisher FIELDVUE DVC6200 Digital Valve Controllers

ValveLink SNAP-ON Application

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

QSS Installation & Calibration. Presented by: Joe Gomes Field Service Manager

Tissue Machine Bearing Failure and PeakVue Problem Resolution

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Baumann Sanitary Angle Control Valve

Eddy Current Displacement Transducer Specifications

Eddy Current Displacement Transducer Specifications

Pressure control solutions for your industry. Aerospace & Defense

Fisher TBX Steam Conditioning Valve

diagnose valve DIAGNOSE VALVE PROBLEMS

DeltaV SIS TM Auxiliary Components

Expand your vibration program to new heights.

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

Innovation in actuation.

Fisher SS-263 Volume Booster

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Baumann Way Control Valve

Rosemount Orifice Series Differential Pressure Flow

Fisher 3024C Diaphragm Actuator

Fisher 3024C Diaphragm Actuator

Monitoring Health of External Solenoid Valve (SOV) with FIELDVUE DVC6200 SIS Digital Valve Controllers

Fisher ENVIRO SEAL Packing System for Rotary Valves

Fisher 685 Piston Actuator

Baumann 24000S Stainless Steel Control Valve

ABB life cycle services Uninterruptible power supplies

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Fisher 480 Series Yokeless Piston Actuators

WARNING. Mounting Instructions D103778X012 June 2013

Application Note. Monitoring Bearing Temperature with ProPAC

Highly Engineered, Quality Locomotive Products. Ingenuity in Motion

Triple offset technology for lower pressures.

Baumann Pneumatic Actuators

Fisher 656 Diaphragm Actuator

KTM PNEUMATIC ACTUATORS AW, AWN SERIES (FOR LARGE SIZED VALVES)

Baumann Little Scotty Bronze Control Valve

Fisher 2506 and 2516 Receiver Controllers

Fisher 657 and 667 Diaphragm Actuators

Baumann Corrosion Resistant Control Valve

Type 289RC Exhaust Booster

CML Electric Actuator for Baumann Series

E-training. Positioners (Pneumatic, Electro pneumatic, I to P converters) Pneumatically actuated valves can be positioned in a number of ways.

Control Valves Positioner

Control Valves Positioner

Fisher 2052 Diaphragm Rotary Actuator

Baumann 24000CVF Carbon & 24000SVF Stainless Steel Flanged Valve Instructions

Fisher FIELDVUE DVC6000 Digital Valve Controller Dimensions

The FMM force tester can be controlled using L1 software for limit, cycling, hold and coefficient of friction testing.

Fisher TBX Hydro Plug Fixture

Fisher 9500 Butterfly Control Valve

Fisher CVX Hydro Plug Fixture

Baumann Mikroseal Control Valve

Type 310A-32A Pressure Reducing Regulator

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Fisher 546 Electro Pneumatic Transducer

Fisher 3660 and 3661 Positioners

Pull-Off Adhesion Tester

KTM PNEUMATIC ACTUATORS AK SERIES (FOR SMALL AND MIDDLE SIZED VALVES)

Fisher 685SE and 685SR Piston Actuators

Fisher eplug complete Rotary Control Valve and Actuator Package

Electric Modulating Actuator Installation, Operation & Maintenance Manual

Type 289P Pilot-Operated Relief Valve

Valve Positioners Offer Improved Control Valve Performance White Paper

GUIDE OF CHANGE MANAGEMENT. Replacement of Fisher POSI-SEAL A81 High-Performance Butterfly Valve with Fisher 8580 High-Performance Butterfly Valve

Bettis M11 Manual Hydraulic Override System Operating Instructions for HD, T, and G Series Pneumatic and Hydraulic Actuators

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

6.0 SPECIFICATIONS CONTENTS. Calibration. According to factory procedureeeeeeeeeeeeeee Accuracy*

DeltaV SIS TMAuxiliary Components

Fisher VBL Volume Booster

Thermal Considerations: Assuring Performance of Vicors Maxi, Mini, Micro Series High-Density DC-DC Converter Modules

D-Series Rack & Pinion Pneumatic Actuators

All of the control valves that we install the Mk. 16IQ positioner on are factory calibrated for proper operation prior to shipment.

TECHNOLOGY AND SIMPLICITY.

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

SHOCK ABSORBER/DAMPER TESTING MACHINE

MS Application. Features. Proportional Valve Actuator General Instructions

Fisher 377 Trip Valve

Top Mount Installation for DP Flowmeters in Steam Service

BAS Construction Checklist

SCHMIDT ManualPress. From 1.6 kn to 22 kn

Fisher 2052 Diaphragm Rotary Actuator

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

EEL Project Design Report: Automated Rev Matcher. January 28 th, 2008

POSITIONERS and Controls for Complete Valve Automation

IMTS 2012 Valve Control

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

DEMOUNTABLE CONCEPTS, INC. RailTrailer Instruction Manual and Maintenance Guide

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

MoistureMatch A next generation grain tester

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 5: DC MOTORS WARNING:

Fisher D4 Control Valve Assembly

Crane Electronics Ltd The force in torque management. tjrs Opta Threaded Joint Rate Simulator Bench

Baumann Series Flexsleev Control Valve Instructions

This section covers the comprehensive range of Torque Calibration equipment manufactured by Gedore Torque.

openrobotics Drive the robot with your machine control makes the difference in integration

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Transcription:

FlowScanner 6000 SGIM-1 and SGIM-2 Strain Gauge Interfaces D103178X012

The SGIM-1 and SGIM-2 Strain Gauge Interfaces for the FlowScanner 6000 The FlowScanner 6000 is a powerful valve diagnostic tool that helps you evaluate the condition of most Air Operated Valves and analyze operating forces from measured actuator pressure. In certain situations, you may want the added ability to measure forces more directly through strain gauge sensors attached to the valve stem. Adding a Strain Gauge Interface to your FlowScanner 6000 will give you that capability. The interface is well matched to the high resolution and range of the FlowScanner 6000 input channel it will give you a low-noise signal that can measure and graph the range of loads on the stem from light friction up to full seating forces. The SGIM-1 and SGIM-2 are designed for easy integration and use. They mount in the accessory pocket of the FlowScanner 6000 operating case and draw power from the FlowScanner 6000 no external power source is required. The SGIM-1 is a single-channel interface for QSS-type sensors only, and the SGIM-2 is a dual-channel interface for use with both QSS and c-clamp type sensors. The sensor cable can be integrated with other valve connections in a common cable and tubing tether. Because this single, short tether carries the control signal, the travel signal, four pressure lines, and the strain gauge signal, you ll only need to run one line from the FlowScanner 6000 to the valve assembly. The cable is well suited to the vast majority of AOVs. For AOV assemblies requiring more pressure or auxiliary signal lines, you can use a second bundle or individual lines. For added convenience, you can leave the cable tether attached to the FlowScanner 6000 during normal use, and then simply coil it inside the top cover for transport and storage. The strain gauge sensor cable can also remain connected to the interface. Figure 1. The FlowScanner 6000 housed in its convenient padded canvas operating bag, with the Interface module integrated into the accessory pocket (left). Shown with cables coiled and ready for transport (below).

The SGIM-1and SGIM-2 Interfaces Offer Unique Features Complete, compact integration These Strain Gauge Interfaces are designed for easy integration and use with the FlowScanner 6000. Simply slip the interface module into the accessory pocket of the FlowScanner 6000 s operating case, and you ll have a compact, highly portable field kit. Shared power system Unlike generic interfaces that require external power sources, the integrated SGIMs draws power directly from the FlowScanner 6000 a truly battery powered solution. The SGIM-2 features reduced power consumption for extended battery life. Direct connection to Teledyne QSS stem sensors With both the SGIM-1 and SGIM-2, you can use a standard connection with the popular Teledyne QSS sensors. An interface cable is provided with the module. The cable can be interchanged with the Teledyne system for MOVs, which allows for easy field replacement. Use with c-clamp sensors- The SGIM-2 has a second input for use with c-clamp sensors, with calibrates LEDs to simplify the required pre-tensioning of these sensors. An adapter cable is available to connect the c-clamp sensors to the SGIM-2. Low-noise, high accuracy circuitry Thanks to the modular circuitry and the clean power provided by the FlowScanner 6000, strain signals from the interfaces are exceptionally clean and usually do not require filtering. You can be confident of the full rated accuracy of the strain gauge sensors: each interface is tested to confirm accuracy of at least 0.05% FS. Easy bridge balancing adjustment- The SGIM-1 has a push-to-turn balance pot to zero the output before testing. The SGIM-2 automatically balances and zeros the output on power up. Full software support The FlowScanner 6.1 software fully supports the use of the SGIM- 1 with QSS sensors. Using stem material properties, the software allows you to read forces directly, as well as graph and analyze for forces, such as friction and seat load for sliding stem valves and operating torque for rotary valves. The software also gives you automated calculation and retest capabilities.

Detailed Information Automated calculations and re-test capabilities Automation is one of the hallmarks of the interfaces. To calculate scaling factors, you simply use the Sensitivity Worksheet to enter the stem diameter and the gauge factors marked in the QSS, and select the stem material from the list. Then, based on the material properties of the valve stem/shaft, the FlowScanner automatically scales electrical signals from voltage to accurate force displays. (Materials properties can also be entered directly from engineering documentation, if required by plant practices.) A snapshot of the completed worksheet can even be saved with the Valve TAG in the database. (When c- clamp sensors are used with the SGIM-2 they are normally used for proof of seat contact, and scaling to force is not used.) Once gauge factors are calculated, they can be saved as devices in standard test setups. Each time a valve is retested, you can select the gauge from a list the calibrated channels are selected automatically when you start to test a valve with the gauge mounted. The software eliminates the need to go through the calculation each time a valve is retested, saving field technicians valuable time. Figure 2. The Sensitivity Worksheet (left) calculates force displays automatically. The Auxiliary Scaling window (below) shows devices available for certain channels. To achieve highly accurate results that are comparable with the analysis from traditional FlowScanner 6000 pressure recordings, the QSS stem sensor should be glued in place on the valve stem following the Teledyne Qualified procedures. Clamp-on sensors can also be used to verify seating contact.

Figure 3. The convenient, two-part field kit: the FlowScanner 6000 operating case and the toolkit/laptop bag. Convenient, field-kit solution for field operation Because the Strain Gauge Interface integrates into the FlowScanner 6000 and draws power directly from it, there s no need to carry extra equipment into the field. You ll still only carry two items: the FlowScanner 6000 operating case and the tool-kit/laptop bag. This unique, highly portable, battery-operated solution is ideally suited for plant environments. Simple pre-tensioning of c-clamp sensors The SGIM-2 incorporates automatic offset for c-clamp sensors and indicating LEDs for adjusting the clamp tension. Simply connect the c-clamp to the interface, power on the FlowScanner, and tighten the c-clamp on the valve stem until one LED is illuminated and one is off. Slowly tighten until the second LED lights up; then back off until it just goes out. The pre-tension is then in the recommended range. Figure 4. Simply adjust c-clamp pre-tension until both LEDs illuminate, and then loosen until one just goes out. No special software or complex procedures are needed.

Enhanced Diagnostics Capability Most of the time, you ll be able to adequately diagnose air-operated valves without attaching strain gauges. There are certain instances, however, when this practice can be beneficial. You can use the Strain Gauge Interface with your FlowScanner 6000 to: Determine whether a valve construction has been set up incorrectly, contacting the lower actuator stop instead of the valve seat. Obtain independent confirmation of seat load for regulatory compliance. Obtain a primary measurement for seat load or friction if the actuator area is unknown. Determine whether friction problems are caused by the actuator or the valve trim. Test open/close valves that have no controlled ramp capability. Evaluate rotary valves with complex linkages.

Using the Strain Gauge Interface in Special Circumstances Determining whether a valve construction is contacting the valve seat Although it s generally more accurate to determine force by actuator pressure than by strain gauge results, you can use a combination of both signals to get a more complete picture of a valve s condition. Figure 5 shows a plot of a strain gauge analysis overlaid on the Net Pressure plot used for traditional FlowScanner 6000 force analysis. Plotting in reference to travel gives you consistent, easy-to-correlate results. The actuator pressure plot (red-blue) shows spikes on both ends where the travel stops are contacted. The stem strain plot only shows a spike on the closed position end, since stem strain is not affected by the upper actuator stop. This analysis gives you positive verification that the valve is closed and seating as indicated by the FlowScanner 6000. Figure 5. Strain gauge analysis overlaid on a net pressure plot. (Obtained using the SGIM-1 Strain Gauge Interface and the FlowScanner 6000 using a Teledyne QSS stem sensor.) Measuring seat load Because the FlowScanner 6000 uses conservative actuator effective area figures, the seat load analysis based on pressure tends to be up to 5% conservative. When measured by a strain gauge, the load tends to be slightly higher because the calculations do not try to be conservative. Typically the results of the two different analyses bracket the actual load obtained. Strain gauge sensors such as the Teledyne QSS claim about +/- 8% accuracy, so results will vary between the two methods.

Locating friction problems The FlowScanner 6000 friction analysis based on pressure readings gives the total valve and actuator friction, while the stem strain sensor does not include any actuator friction. As a result, the strain gauge friction numbers tend to be lower, especially on an actuator that has seals on the actuator stem. Comparing the difference between the total assembly friction (pneumatic results) to the valve friction (stem sensor results) can help you locate where the friction is occurring. Testing open/close valves When testing AOVs that operate from a switched pressure signal instead of controlled pressure, the strain gauge method can simplify testing because you don t need to use a temporary I/P converter to obtain accurate pressure measurements. The strain signal and travel can simply be recorded while the valve is switched open/closed, and the results plotted for analysis. Results can even be obtained when it is not feasible to tap into the actuator pressures. The valve stroking speed, however, does affect the friction readings (Figure 6). In Figure 6, the controlled ramp test (red) shows lower friction than the stepped stroke test (blue). As long as the same method is used in repeat testing, the changes in condition can still be adequately trended. Figure 6. Overlay of a stepped open/close stroke compared to a controlled ramp stroke.

Evaluating rotary valves Some rotary valves have a complex linkage between the actuator and valve that reduces the accuracy of determining torque values from actuator pressure. The QSS stem sensor can be applied directly to the shaft of a rotary valve, which delivers a direct readout of torque that eliminates linkage errors. As with sliding stem valves, the strain reading accuracy is not affected by rapidly changing pressures, so even valves with uncontrolled stroke speed can be analyzed. Figure 7 shows a plot of torque vs. travel for a rotary valve with a QSS sensor mounted on the shaft. The plot shows the increasing torque needed to overcome a seating restriction due to foreign material in the valve throat. While the plot clearly shows that about 50 in-lb torque is needed to overcome the seating resistance, you cannot quickly determine how close this may be to the maximum torque available from the actuator. In other words, you don t know how much worse the friction can get before the valve fails to close. Figure 7. Plot of torque vs. travel for a rotary valve with QSS sensor. A combination of the strain plot and the traditional actuator pressure plot, shown in Figure 8, provides a more complete picture. It shows you that at the point of maximum resistance, there is less than one psi of additional pressure available to overcome any additional resistance that may develop. You can also see that simply increasing the supply pressure a few psi would give enough additional reserve force to assure operation. Figure 8. Strain and actuator pressure plots.

Recommendation The use of the SGIM-1 or SGIM-2 Strain Gauge Interface and strain gauge sensors on AOVs do provide enhanced diagnostics capability in many cases. Whenever feasible, however, they should be used along with the traditional FlowScanner 6000 pneumatic analysis to obtain a complete picture of the valve condition.

Specifications Power Powered by the FlowScanner 6000 12Vdc accessory output Operating Temperature Limits Operating temperature: -40 to 155º F (-40 to 70º C) Operating humidity checks: 95% non-condensing Input Standard QSS 4-pin Lemo connector for 4-wire full bridge strain gauge devices such as the Teledyne QSS Input range -- SGIM-1: +/- 3 mv/v; SGIM-2: +/- 3.5 mv/v Output Direct connection to FlowScanner 6000 Auxiliary channel H Output range SGIM-1+/- 5 VDC; SGIM-2 +/- 10VDC Sensitivity SGIM-1: Nominal 0.6 mv/v/v; SGIM-2 Nominal 0.35 mv/v/v Effective Gain SGIM-1: Nominal 6.0; SGIM-2 Nominal 3.5 (for FlowScanner software worksheet calculation) Controls SGIM-1: Push-to-turn balance pot to zero output (SGIM-2 automatic zero) Housing Plastic case sized to fit accessory pocket of FlowScanner 6000 operating case Included Accessories QSS connection cable Optional Accessories c-clamp connection cable Accuracy +/- 0.05% FS Ordering Information To order the FlowScanner 6000 SGIM-1 or SGIM-2, contact your local Emerson representative, or call Emerson Instruments Valve Services in Columbia, SC, at 803-736- 3101.

As the largest supplier in North America, Emerson's can help you avoid unplanned costs and unscheduled maintenance through our comprehensive startup, diagnostic, repair, and maintenance services. We are one of the offerings of Emerson Process Management's Asset Optimization Division that combines world-class services with innovative technologies to improve the availability and performance of production assets. Our knowledge of factory design, engineering, and specifications enables us to resolve problems quickly, maximizing your uptime. Put us to work today, and you'll discover that we're your best choice as a services partner. For more information or to schedule service, please call your local Emerson Process Management sales representative or the North American Response Center at 1-800-654-7768. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. All rights reserved. PlantWeb are marks of one of the Emerson Process Management group of companies. The Emerson logo is a trademark and service mark of Emerson Electric Company. All other marks are the property of their respective owners. Emerson Process Management 2003 Emerson Process Management 205 South Center Street All Rights Reserved. The Emerson logo is a Marshalltown, IA 50158 trademark and service mark of Emerson Process Management.