24kV ET1 Removable AC Metal-enclosed Switchgear With VE24 Encapsulated Pole Vacuum Circuit Breaker

Similar documents
Powering business worldwide

XIRIA Green, Smart, Compact solution

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

40.5kV ET2 Removable AC Metal-enclosed Switchgear

E-VAC Series Medium Voltage Vacuum Circuit Breaker

12kV W-VACi Series Medium Voltage Vacuum Circuit Breaker

Vacuum Circuit Breaker VS1

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

W-VACi MV circuit breakers

Removable AC Metal-enclosed Switchgear

40.5kV W-VACi Series Medium Voltage Vacuum Circuit Breaker

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

12kV xdl Removable AC Metal-enclosed Switchgear

Medium voltage vacuum circuit breaker. E-VAC series

Unitole UP kv Primary substations Motor control centres

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Unitole UP kv Primary substations Motor control centres

E6X MCB series. More complete More value

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv Product Guide. W-VACi. for safety, reliability and performance

Gas Insulated Ring Main Unit RVAC. Professional solutions, Reliable power

Gas Insulated Ring Main Unit RVAC. Professional solutions, Reliable power

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

Product Specification

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

Innovac SVS/08 - SVS/ kv modular switchgear

Metal Clad Air Insulated Switchgear

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

CPG.0 Single busbar gas-insulated cubicles

36kV Gas Insulated Medium Voltage Switchgear

WOLUN. ZN63A-12 (VS1) Type. ZN63A-12 (VS1) Type Indoor High Voltage Vacuum Circuit Breaker. General Introduction. Technical Specification

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Instruction for Installation and Operation

the safe, reliable, and efficient choice for MV switchgear

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

NXPLUS C Single busbar. Maintenance-free for lifetime

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

PIX-H Metal-clad switchgear up to 17.5kV

Experience, innovation and reliability

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Gas Insulated Ring Main Unit RVAC. Professional solutions, Reliable power

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

MEDIUM VOLTAGE SWITCHGEAR

Metal Clad Switchgears

Xiria 24 kv Ring Main Unit

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

MESG 12 / 17.5 / 24 / 36 KV

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

B kv T&D GAS INSULATED SWITCHGEAR

Vacuum Circuit Breaker

Electrical sector solutions E Line family. Industry leading design in a compact package

Xiria 12 kv Ring Main Unit in IEC and ENATS design

Key features. DESIGNS: - Conservator type - Hermetically sealed

Modular medium-voltage switchgear. NorMax

This small footprint makes a BIG impact

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Medium Voltage Products Table Of Contents

33KV INDOOR SWITCHGEAR

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

SafeGear TM Motor Control Center Arc resistant metal-clad construction

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Medium Voltage Products Table Of Contents

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Capabilities Brochure

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Medium Voltage Metal-Enclosed Switches

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Gas Insulated Metal-clad Switchgear, HMGS!

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Solar Power Switchgear & Energy Storage Renewable Energy Systems

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Medium Voltage Metal-Enclosed Switches

Power Systems PU. HYOSUNG MV Gas Insulated Switchgear. ProGIS[MV GIS]

Solid Dielectric, Three Phase Reclosers CATALOG VS11

8DJ. Maintenance-free for lifetime

Extensible Unit - VCE2a

Transcription:

24 ET1 Removable C Metal-enclosed Switchgear With VE24 Encapsulated Pole Vacuum Circuit Breaker

utomotive Powering business worldwide erospace Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing world. We help our customers worldwide manage the power they need for buildings, aircraft, trucks, cars, machinery and entire businesses. nd we do it in a way that consumes fewer resources. Truck Hydraulics Electrical Next generation transportation Eaton is driving the development of new technologies from hybrid drivetrains and emission control systems to advanced engine components that reduce fuel consumption and emissions in trucks and cars. Higher expectations We continue to expand our aerospace solutions and services to meet the needs of new aviation platforms, including the high-flying light jet and very light jet markets. Building on our strengths Our hydraulics business combines localised service and support with an innovative portfolio of fluid power solutions to answer the needs of global infrastructure projects, including locks, canals and dams. Powering Greener Buildings and Businesses Eaton s Electrical Group is a leading provider of power quality, distribution and control solutions that increase energy efficiency and improve power quality, safety and reliability. Our solutions offer a growing portfolio of green products and services, such as energy audits and real-time energy consumption monitoring. Eaton s Uninterruptible Power Supplies (UPS), variable-speed drives and lighting controls help conserve energy and increase efficiency. 1

MV switchgear technology is in our DN Eaton Corporation is a worldwide leader in the design, manufacture, and sale of safe, reliable and high-performance medium voltage power distribution equipment in accordance with GB and NSI standards. Complete Global Medium Voltage Switchgear Solutions Eaton, a premier leader in designing and manufacturing power distribution and protection equipment in the electrical industry, offers a comprehensive range of medium voltage (MV) solutions to meet the needs of virtually every application. From products that feature cutting-edge design that allow for easy access, maintenance and space savings, to arc-resistant products that enhance safety, Eaton s medium voltage solutions provide a variety of products for every need. dditionally, Eaton s global service network provides maximum customer support in all regions of the world. s one of the few completely vertically integrated and diversified industrial manufacturers in the world, Eaton designs not only MV assemblies, but also the key components that comprise the MV solutions from steel housing and circuit breaker compartments to vacuum interrupters, circuit breakers, bus systems and fuses. Eaton s MV heritage, strengthened by acquisitions such as Westinghouse DCBU, Cutler Hammer, MEM and Holec, has resulted in breakthrough MV technologies and numerous international patents over the years. Part of Eaton s complete electrical PowerChain Solutions which help businesses minimize risks while realizing greater reliability, cost efficiencies, capital utilization and safety Eaton s medium voltage equipment meets all applicable standards and certifications such as NEM / NSI, GB, UL, IEEE, KEM and CS. When it comes to medium voltage solutions, you can trust the one name with a long history of proven performance: Eaton. 2

24 ET1 Removable C Metal-enclosed Switchgear 24 ET1 Removable C metal-enclosed switchgear With VE24 Encapsulated pole VCB 24 ET1 switchgear with advanced technology Safe and reliable Metal-clad and fully enclosed structure doption of balanced electric filed, with main conductors using thermal shrinkage material for insulation, providing higher dielectric performance LV compartment is separate from each HV compartment Fast closing earthing switch is used for earthing and provides short-circuit current closing capacity ll operations can be conducted when the door panel is closed, including breaker switching on and off, breaker trolley s drawing in or out, as well as earthing switch s switching on and off. Reliable latch device is used to effectively prevent misoperation Through the front and rear observation windows in the door panel, breaker s switching status, trolley position, mechanism energy stored status, earthing switch switching position and cable end connection status can be clearly viewed In line with GB3906 and China power industry standards Highly practical Enclosure protection degree is IP4X can prevent sewage and little animals from entrance VCB trolley is maintenance free and the equipped operating mechanism requires only a little maintenance Good interchangeability of trolleys, very easy to replace circuit breakers Secondary wire is laid in ample wire casing, neat and convenient for inspection Wide application Can be used for incoming and outgoing of cable and busbar or mixed incoming and outgoing of cable and busbar Normal standard cable end can be used Can be connected to several cables 3

24 ET1 Removable C Metal-enclosed Switchgear Technical data ET1-24 switchgear technical data Main switchgear technical data Rated voltage 24 24 Rated frequency Hz 50 50 Rated 1min power frequency withstand voltage Rated lighting impulse voltage(bil) 1 1 Power frequency voltage of auxiliary control circuit V 2000 2000 Rated current 630,10,1600,2000,00,3150 630,10,1600,2000,00,3150 Rated short-time withstand current (4s) Rated peak withstand current 63 80 Rated short-circuit breaking current Rated short-circuit making current 63 80 Rated voltage of auxiliary control circuit V DC/C 110/220 DC/C 110/220 Protection degree IP 4X (compartment: IP2X when breaker door is open) IP 4X (compartment: IP2X when breaker door is open) Dimension (W*D*H) *1800*20, x2200(2300)x20 *1800*20, x2200(2300)x20 Weight kg 8-14 8-14 Main technical data of VE24 VCB Rated voltage 24 24 Rated frequency Hz 50 50 Rated 1min power frequency withstand voltage Rated lighting impulse voltage(bil) 1 1 Rated current 630,10 630,10,1600,2000,00,3150 Rated short-time withstand current (4s) Rated peak withstand current 63 80 Rated short-circuit breaking current Rated short-circuit making current 63 80 Rated short-circuit operating sequence O-0.3s-CO-180s-CO O-0.3s-CO-180s-CO 4

24 ET1 Removable C Metal-enclosed Switchgear Structure and operating principles Structure overview 24 ET1 switchgear is composed of cubicle and removable parts (so called trolley). The cubicle is separated into several functional compartments by metal sheet, including busbar compartment, circuit breaker compartment, cable compartment and LV compartment. Switchgear removable parts can be equipped with VCB trolley, voltage transformer trolley, lightning arrester trolley and fuse trolley. Pressure relief device Pressure relief devices are installed above trolley compartment, busbar compartment and cable compartment. Special sealing ring on the door seals the panel door. In case of faults inside the compartments resulting in arc, the pressure is going up inside the switchgear and the pressure relief equipped on the top will open automatically, to release pressure and high temperature gas. In this way, it can ensure the safety of operating staff and the switchgear. Secondary plug and trolley position interlo cking The secondary connection of the switchgear and trolleys are conducted via secondary plug coordination. The secondary plug is connected to trolleys through a nylon bellow. The plug is located on the upper right side of switchgear s trolley compartment. Only when the trolley is on Test position, the secondary plug can be plug in or out. When the trolley is on Operating position, the plug is locked. Electrical indication device The switchgear can install electrical indication device in primary circuit. The device includes high voltage sensors and an indicator, and can indicate high voltage circuit electrical status. It can also cooperate with electromagnetic lock to conduct compulsory latching on operating handle, cubicle door and adjacent cubicles. Thus, it can prevent from withdrawing isolation trolley with loads, prevent earthing switch from energized closing, and prevent from entrance of energized compartment. In this way, it can increase prevention performance of the equipped products. Prevention of condensation In order to prevent condensation in high humidity or dramatically changed temperature environment, electrical heater is installed separately in circuit breaker compartment and cable compartment, to avoid dielectric accidents in the above conditions. Earthing device Cable compartment installs additionally 60*5 mm 2 earthing copper bus which goes through adjacent cubicles and with good connection to cubicles. The copper bus is used for direct earthing components. Since the whole cubicle is joint by aluminum zinc coated steel plates, the cubicle is in good earthing status, thus ensuring safety of operating staff. Structural diagram of 24 ET1 switchgear 83 20 1800 5

24 ET1 Removable C Metal-enclosed Switchgear Dimension Interlock devices to prevent misoperations 24 ET1 switchgear has a series of interlock devices to fundamentally prevent dangerous situations and misoperations which may result in serious consequences, and thus effectively ensuring safety of operating staff and the switchgear itself. The detailed interlock includes: When circuit breaker and earthing switch are in opening position, the trolley can move from TEST/isolation position to SERVICE position. If the circuit breaker is in closing condition and is racked, the trolley will trip automatically when moving from TEST/isolation position to SERVICE position. Reverse movement has the same result (mechanical interlock) Only when the trolley is completely engaged in TEST or SERVICE position, the circuit breaker can close (mechanical interlock) If the trolley is in TEST or SERVICE position without control voltage, the circuit breaker can not close. It can only be manually opened (mechanical interlock) If the trolley is in SERVICE position, the control plug is locked and can not be pulled out. When the earthing switch is closed, the trolley can not move from TEST/isolation position to SERVICE position; when the trolley is in SERVICE position, the earthing switch can not be closed (mechanical interlock) Switchgear s mounting basis and base plate cutout dimension diagram 1800 1172 385 218 2200 1172 385 Ø13 Ø13 1200 1200 3 1200 790 890 Front - Rotate 1800 0 Installation basic Schematic(1800mm) 890 790 3 1200 Front - Rotate 2200 0 200 200 1500 Front 100 1500 Front 100 10# Channel 10# Channel 1800 385 1172 8-14x24 100x200 790 750 Secondary cable hole Switchgear bottom carting (1800mm) 2200 218 385 1172 150 8-14x24 100x200 790 750 Secondary cable hole 450 150 450 500 900 Switchgear bottom carting (2200mm) Installation basic Schematic(2200mm) 6

VE24 VCB VE24 VCB Standards GB 1984-2003 HV C Circuit Breaker JB 3855-1996 3.6-.5 Indoor C HV Vacuum Circuit Breaker DL/T 3-2000 12-.5 HV Vacuum Circuit Breaker Ordering Technical Conditions 7 VE 24 VCB is Eaton s new generation of indoor vacuum circuit breaker with integrated encapsulated pole, with ratings of 24, 630 to 3150 / to. VE24 VCB is an indoor circuit breaker of 3-phase, 50Hz and 24 rated voltage. It is applicable for protection and control units of power grid equipment, industrial and mining power equipments. The product is equipped with unique advancing mechanism and thus become a trolley unit. Its primary circuit is encapsulated by epoxy resin useing PG technology to prevent vacuum interrupter and other main circuit parts from collision, dust and condensation. VE24 VCB is used in circumstances which require frequent operation of rated operating current or repeatedly switching of short-circuit current. It is also used in harsh environmental applications. Normal service condition: mbient temperature: Maximum temperature: + C Minimum temperature: -15 C mbient humidity: Daily average RH: 95% Monthly average RH: 90% Daily average vapor pressure: 2.2*10-3 Mpa Monthly average vapor pressure: 1.8 *10-3 Mpa ltitude: Not more than m Seismic intensity not over 8 degree Surrounding air is not polluted by dust, smoke, corrosive and/or combustible gas, steam or salt fog Technical features VE24 adopts proved PG technology to make vacuum interrupter and main conduction circuit embedded into insulating cylinder. In this way, it solves the problem that the insulation parts are influenced by environment with reduced withstand voltage level, ensuring that the VCB can be applicable in harsh environment. VE24 uses China s top-class vacuum interrupter with high breaking capacity and high reliability. It meets actual operation requirements, with primary section of maintenance free. Proven spring mechanism provides stable and reliable performance and long service life. It is easy to operate with superior anti-corrosion capacity, requiring only very little maintenance within its lifetime. Type tests are conducted, according to GB1984-2003 s extended electrical life of E2 level, extended mechanical life of M2 level and capacitive current switching of C2 level with very low re-strike probability. Products are assembled to guarantee product consistency. Before products are delivered, push-in tests are conducted for standard panels, ensuring interchangeability and universality. ll products have passed hundreds of mechanical operation run-in tests before delivered in factories, ensuring product performance at its most stable stage. dvance imported testing equipments are used to make records of empty load mechanical features for each product, and to provide users with concerned characteristic curves. In this way, it ensures reliability of product quality.

VE24 VCB Technical data Spring operating mechanism data Technical data of stored energy motor Item Rated operating voltage (V) Motor rated input power (W) Normal operating voltage range Stored energy time at rated operating voltage (s) Data C, DC110 ( 80 when over 00) 85%-110% of rated operating voltage 15 C, DC220 ( 80 when over 00) 85%-110% of rated operating voltage 15 Technical data of opening and closing coils Item Rated operating voltage (V) Rated operating current of closing coil () Rated operating current of opening coil () Normal operating voltage range Data C, DC110 2.0 1.8 Closing: 80%-110% of rated operating voltage Opening: %-120% of rated operating voltage; Not opening when 30% rated operating voltage C, DC220 1.0 0.9 Closing: 80%-110% of rated operating voltage Opening: %-120% of rated operating voltage; Not opening when 30% rated operating voltage Technical data of VE24 vacuum circuit breaker (phase-to-phase distance at mm) Rated voltage 24 24 Rated frequency Hz 50 50 Rated 1min power frequency withstand voltage Rated lighten impulse voltage 1 1 Rated current 630/10 630/10/1600/2000/00/3150 Rated short-time withstand current (4s) Rated peak withstand current 63 80 Rated short-circuit breaking current Rated short-circuit making current 63 80 Rated short-circuit operating sequence O-0.3s-CO-180s-CO O-0.3s-CO-180s-CO Conduction circuit resistance per phase µ 60(630) 50(10) verage closing speed verage opening speed Closing time Opening time Bounce time when contact closing Non-periodicity of 3-phase closing and opening Phase to phase center distance llowable wearing thickness of moving and fixed contacts m/s m/s ms ms ms ms mm mm 35(1600~2000) 0.8~1.2 1.1~1.7 35~70 20~50 2 2 3 (over 00) 0.8~1.2 1.1~1.7 35~70 20~50 2 2 3 8

VE24 VCB Dimension Dimension diagram of VE24 vacuum circuit breaker Cubicle width Rated current Rated short-circuit breaking current () P B C D F G J K N R S T 800 630 210 638 2 6 0 685 ø35 3 737 277 800 630 210 638 2 6 0 705 ø35 345 757 277 800 10 210 638 2 6 0 685 ø49 3 737 277 800 10 210 638 2 6 0 705 ø49 345 757 277 630 838 852 8 850 685 ø35 3 737 377 630 838 852 8 850 705 ø35 345 757 377 10 838 852 8 850 685 ø49 3 737 377 10 838 852 8 850 705 ø49 345 757 377 1600~2000 838 852 8 850 705 ø79 345 735 757 685 377 0 00~3150 838 852 8 850 781 ø109 345 735 8 685 377 0 9

VE24 VCB Wiring principle diagram Internal electrical wiring principle diagram of VE 24 vacuum circuit breaker S9: auxiliary contact (switching when breaker is on Operating position) S8: auxiliary contact (switching when breaker is on Test position) S2: auxiliary switch S1: auxiliary switch (switching after closing spring is energy stored QF: auxiliary switch (switching at switching on and off) HQ: closing coil TQ: opening coil R0-R1: resistance Y7-Y9: indirect Overcurrent tripping release (optional) Y1: latching coil (optional) V2-V4: bridge rectifier (cancelled at DC operation) M: stored energy motor JP1-JP11: jumper KO: tripping prevention relay (optional) Note: 1.The diagram shows circuit breakers at Test position, energy unsaved, closing status 2.When operating supply is DC, polarity in the virtual box is the same 10

Eaton is a power management company with 2014 sales of $22.6 billion. Eaton provides energy-efficient solutions that help our customers effectively manage electrical, hydraulic and mechanical power more efficiently, safely and sustainably. Eaton has approximately 99,000 employees and sells products to customers in more than 175 countries. For more information, visit www.eaton.com.cn/electrical. Eaton Corporation sia Pacific Headquarter No.3, Lane 280, Linhong Road, Changning District, Shanghai 200335 www.eaton.com.cn/electrical 2015 Eaton Corporation ll Rights Reserved Printed in China EECZ-MV-ET1-24-EN(2015-12) Eaton is a registered trademark of Eaton Corporation. ll trademarks are property of their respective owners.