GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Similar documents
PT Guna Era Manufaktura. Catalogue GAE TPS \ Medium Voltage Switchgear 12kV - 24kV \ M GAE TPS. Medium Voltage Switchgear 12kV - 24kV

GAE MCC Modular-C. Catalogue Standardized Motor Control Centres. PT Guna Era Manufaktura

Metal Clad Air Insulated Switchgear

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Metal Clad Switchgears

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Unitole UP kv Primary substations Motor control centres

Vacuum Circuit Breaker

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Unitole UP kv Primary substations Motor control centres

Air-insulated switchgear UniGear type ZS1

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

CPG.0 Single busbar gas-insulated cubicles

Gas Insulated Metal-clad Switchgear, HMGS!

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Vacuum Circuit Breaker VS1

MESG 12 / 17.5 / 24 / 36 KV

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

PIX-H Metal-clad switchgear up to 17.5kV

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

the safe, reliable, and efficient choice for MV switchgear

PowerCube type PB series A complete solution for OEMs

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

UniGear. Technical Guide

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Gas Insulated Switchgear

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

ZX2 Gas-insulated medium voltage switchgear

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

NXPLUS C Single busbar. Maintenance-free for lifetime

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

UniGear type ZS1. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

FIXED VCB AIR INSULATED SWITCHGEAR

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

36kV Gas Insulated Medium Voltage Switchgear

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

CM5-03. Medium voltage air insulated arc proof metal clad Switchgears MINIVER/C

Power IT Air Insulated Cubicle Uniswitch

Modular medium-voltage switchgear. NorMax


TECHNICAL MANUAL AND APPLICATION GUIDE. Engineering Your Power

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

Innovac SVS/08 - SVS/ kv modular switchgear

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

ZX-Family Gas-insulated medium voltage switchgear

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

Epoxy Technology Embedded Poles

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

with Vacuum Circuit Breaker HAF

MEDIUM VOLTAGE SWITCHGEAR

Documents and Addresses

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kv, Gas-Insulated

CBGS-0. Medium voltage distribution

Prüffeld der Schaltwerke

40.5kV ET2 Removable AC Metal-enclosed Switchgear

MCSG 12kV / A

Benefits, typical uses

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Report No.: MS/E Copy No.: 0 Contents: 140 sheets

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Adak Behin Niroo. co.com

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

Metal Clad VCBs ~ Mk1

33KV INDOOR SWITCHGEAR

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

STANDARDIZED LOW VOLTAGE SWITCHBOARDS UP TO 690V-6300A-100KA

AIR INsULATeD switchgear >> PIX. up to 24 kv. Air-insulated switchgear with vacuum circuit-breaker. system configuration.

This small footprint makes a BIG impact

8DJ. Maintenance-free for lifetime

IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

Transcription:

GAE CLAD \ METALCLAD SWITCHGEAR up to 24 kv \ M600204.15 PT Guna Era Manufaktura Catalogue 2015 GAE CLAD Vacuum Circuit Breaker With Embedded Poles Metal - Clad Switchgear Up To 24 kv

General Description Introduction Gaeclad series is metal clad type switchgear, designed, assembled and tested to comply with the latest IEC standards. Gaeclad have been tested for resistance to internal Arc fault IAC AFLR as per IEC 62271-200. Gaeclad have been designed and manufactured with functionality and safety in mind by using VCB that excel in breaking performance. The switchgear contribute to energy conservation in power receiving/distribution facilities of power generating station and their substation, industrial plants, building, and railway power. Features 1. Modular design for easy interfacing with existing switchgear 2. Breaker can be operated in service position and test position 3. Circuit breaker mounted in withdrawable cassette 4. Mechanical interlock for safety operation 5. Longmaintenance free operating time 2 Gae Clad \ Metalclad Switchgear Up To 24 Kv \ M600204.15

Technical Data Electrical Data Description Data Switchboard GAECLAD GC 630 GAECLAD GC 24 Type of construction Metal-clad Metal-clad Rated voltage (kv) 24 24 Insulation levels (kv) 24/50/125 24/50/125 Rated frequency (Hz) 50 60 50 60 Rated main busbar current (40 C) (A) 630/1250/1600/2000/2500 630/1250/1600/2000/2500 Rated branch connection current (40 C) (A) 630 2000 Rated short time current (ka) 25 25 Arcing proof withstand current (ka) 25 25 Tested according to IEC standards IEC standards Dimensions & Weights Description Data Switchboard GAECLAD GC 630 GAECLAD GC 24 Height mm (h) 2200 2200 Width mm (w) 1000 1000 Depth mm (d) 1900 1900 Weight (kg) 950 1250 D B A GaeClad front & cross section view A Busbar compartment C B C D Circuit Breaker compartment Cable compartment Low Voltage compartment Gae Clad \ Metalclad Switchgear Up To 24 Kv \ M600204.15 3

Vacuum Circuit Breakers Introduction The GV series embedded pole circuit breaker can be universally applied within suitable cubicles installed in power plants, substations, petrochemical plants, metallurgical industries, manufacturing industries, airports and residential areas. The GV series is available in a nearly complete series for medium voltage and for all commonly used rated currents, from 630A to 4000A, and for rated breaking current of up to 50 ka. The embedded poles of the GV series are manufactured only with high-grade epoxy resin, using APG casting technology. Thus, the vacuum interrupter is totally separated from all environmental hazards, which gives the circuit breaker its high level of operational safety, even under adverse conditions. Embedding in epoxy resins also help to reduce dimensions and so saves space. 4 Gae Clad \ Metalclad Switchgear Up To 24 Kv \ M600204.15

Technical Data of Vacuum Circuit Breakers Rated voltage Description Unit Parameter Rated short time power frequency withstand voltage (1min) Rated lightning impulse withstand voltage (peak) kv 12 24 42 65/50 75 125/125 Rated Frequency Hz 50/60 50/60 Rated current A 630/1250/1600/2000/2500/3150/4000 630/1250/1600/2000/2500/3150 Rated short circuit breaking current Rated short time withstand current ka 20/25/31.5/40 20/25/31.5 20/25/31.5/40/50 20/25/31.5 Rated peak withstand current 50/63/80/100/125 50/63/80 Rated short circuit making current (peak) 50/63/80/100/125 50/63/80 Rated short circuit duration time s 3 3 Mechanical endurance op 30.000/20.000 10.000 Rated capacitor bank making surge rated single/back to back capacitor bank breaking current ka 12.5 (frequency 1000Hz) 12.5 (frequency 1000Hz) A 630 / 400 630 / 400 Rated electrical endurance Compliance with Class E2 Compliance with Class E2 Secondary circuit power frequency withstand voltage V 2000 2000 Rated operating voltage AC220, AC110, DC220,DC110 AC220, AC110, DC220,DC110 Rated operating sequence * 0-0.3s - CO - 180s - CO 0-0.3 s - CO - 180 s - CO Charging time s 15 15 Contact distance 9 ± 1 13 ± 1 Contact travel mm 3 ~ 5 3 ~ 5 Central distance between phases 150 ± 1.5, 210 ± 1.5, 275 ± 1.5 210 ± 1.5, 275 ± 1.5 contact bounce at closing 3-phase opening/closing simultaneity ms 2 2 2 2 Average opening speed 1.-~1.5 1.2-~1.7 m/s Average closing speed 0.6~1.0 0.7~1.1 Closing time 30 ~ 60 30 ~ 60 ms Opening time 20 ~ 50 20 ~ 50 Contact bounce at opening 3 3 mm moving/fixed contact abrasion 3 3 * Rated short-circuit breaking current <40kA, Ɵ=0.3s ; Rated short-circuit breaking current 40kA, Ɵ=180s Gae Clad \ Metalclad Switchgear Up To 24 Kv \ M600204.15 5

Single Line Diagram of Typical Units Incoming Outgoing Outgoing LBS Fuse Coupler Bus VT & ES Bus VT 6 Gae Clad \ Metalclad Switchgear Up To 24 Kv \ M600204.15

Certificates SPM GAECLAD 630 SPM GAECLAD GC24 ISO 14001:2004 OHSAS 18001:2007 ISO 9001:2008 INTERNAL ARC REPORT Gae Clad \ Metalclad Switchgear Up To 24 Kv \ M600204.15 7

GAE CLAD \ METALCLAD SWITCHGEAR up to 24 kv \ M600204.15 PT Guna Era Manufaktura JI Jati Raya Blok J2 No 1-3 Newton Techno Park, Lippo Cikarang Bekasi 17550 Indonesia T +62 21 8990 7620 F +62 21 8990 7959 E info@gae-gae.co.id W www.gae.co.id