MEDIUM VOLTAGE
MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators, transformers, motors, capacitor banks. The switchboards are composed combining the various typical standard cubicles. TYPICAL USES Utilities and Power Plants Power Stations Generator switchgear Transformer stations Main and auxiliary switchboards Industry Metallurgy Pulp and Paper Cement Chemical Rolling mills Automotive Petrochemical Oil and gas STANDARD CEI 17-6 Italian standard IEC 62271-200 International standard IEC 60-298 (replaced by IEC 62271-200) DPR 547 Italian accident prevention Standard IEC 60129 switches IEC 60694 High voltage switchgear IEC 62271 Circuit breakers These switchboards have performed all relevant tests carried out by qualifi ed laboratories. Marine applications Drilling platforms Off-shore oil rigs Ferries and ships Services Hospitals Infrastructures Data center Transports Airports The company is qualified to supply standard ENEL type units. Ports Railways 2 3
FEATURES General Characteristics According to the international standard IEC 62271-200 Circuit-breaker: earthing of circuit-breaker is ensured on circuit-breakers, instrument transformers and terminals are readily accessible for inspection and maintenance purposes. the CE-B switchboards are classifi ed for loss of service continuity category as LSC2B with partition class PM (Metallic Partitions). The optional version CE-BA is also foreseen fully withstanding to internal arc fault: Internal arc classifi cation (IAC) the whole isolating stroke by means of a sliding jaw type contact on the copper conductor which is directly connected with the earthing bus-bar. Components: all main components such as CTs, VTs, etc., are positively earthed. Easy inspection and maintenance: through easy access to the equipment in the various compartments by hinged doors or removable bolted panels and through the isolation and withdrawal on truck of circuitbreakers, VT, fuses. Accessibility type: A (restricted to authorized personnel only) F (Front) L (Lateral) R ( Rear) Doors: are connected to the frame by a 25 mmq. cross section fl exible braids. bus-bar: the earthing bus-bar in copper with a normal 350 mmq. cross section runs along the length of the switchboard, thus ensuring maximum safety for personnel Easy installation and connection: the cubicles are factory assembled and tested before being shipped to site, therefore they only need to be secured to the fl oor, coupled together and connected to the external circuits. and equipment. Mechanical characteristics Enclosure: Under normal operation the degree of protection is of IP 31 for metal enclosure and IP2X in the LV instrument compartment. The individual structures are made of die-bended galvanized sheet steel elements of no less than 2 mm thickness. The external coloured panels are realized with carbon steel painted with electrostatic epoxy powder, the standard colour is light grey RAL 7035 smooth (all RAL scale colours or specifi c colours can be realized on request). Standard painting minimum thickness of 60 +/- 10 microns is guaranteed. Structure: all structural parts are solidly fastened together by special screws ensuring a good electrical contact between Access and limited overall dimensions: the overall dimensions are particularly restricted if compared with the high performances achieved for the insulation level, rated busbars current and short-circuit current. Optionally only front access could be required for installation and maintenance. Versatility and fl exibility: any single line diagram can be realized to meet the most varied technical requirements. Special and customized adaptation units allow easy extension of existing switchboards even from supplied by other suppliers or not jet in production. Maximum service reliability: reinforced Personnel safety ensured by: positive earthing on the entire switchboard structure earthing of circuit-breaker frame throughout racking-in or withdrawing operations; metal shutters automatically operated during circuit breaker truck movement; metal shutters automatically operated during VTs truck movement; insulating protections and coatings are available for live parts; easy access to low voltage apparatus and control wirings without any risk of accidental contact with medium voltage parts; set of mechanical and electromechanical interlocks; various signalling and control devices. Standard routine factory tests: Visual inspection and check. Mechanical sequence operations. Cabling check. Electrical sequence operations. Insulation test. the connected parts. Nuts and bolts used to assemble structure and enclosure are galvanized and passivated with minimum thickness of 12 microns. insulation of all live parts minimizes the occurrence of faults between phases or to earth. The various compartments of each cubicle are fully segregated and can, besides, be simply and rapidly inspected. As a matter of fact, equipment such as No fi re risk: metal partitions of compartments and use of self-estinguishing insulating material prevent fi res from spreading. 4 5
TECHNICAL DATA DIMENSIONS Electrical Data Rated voltage kv 12 17,5 24 Rated power frequency withstand voltage (1min) kv 28 38 50 Rated lightning impulse withstand voltage kv 75 95 125 Rated frequency Hz 50/60 50/60 50/60 Rated short-time withstand current (3 sec) ka 50 50 40 Peak current ka 125 125 100 Internal arc withstand current IAC-FLR (1sec)* ka 50 50 40 Rated current max. A 3150 3150 2500 Rated current with forced ventilation ** max. A 4000 4000 4000 Rated current with two breakers in parallel ** max. A 5000 5000 4000 Note * Internal arc withstanding in option ** Type tested Rated voltage 12KV 17,5KV 24KV Normal Service Conditions Maximum ambient temperature C +40 Minimum ambient temperature C -5 Depth (mm) 1625 1860 2060 Height (mm) 2325 2325 2325 Height (mm) - IAC 2780 2780 2780 Width (mm) 600 800 1000 800 1000 800 1000 Height m a.s.l. 1000 Maximum relative humidity % 95 Rated current up to (A) 630 1600 4000 1600 4000 1600 2500 For different conditions contact our offi ces. Dimensions could be affected by specifi c equipment and confi guration. 6 7
CONSTRUCTION SAFETY INTERLOCKS Typical composition: A Instrument compartment All the low voltage equipment can be housed in the instrument compartment, which is usually placed above the circuitbreaker compartment B Circuit-breaker compartment This compartment is designed to accommodate the circuitbreaker, contactor or link complete of its withdrawable truck and all mechanical parts required for the extraction. The device is provided with auxiliary switches for signalling the connected position and disconnected/test position. C Feeder compartment The feeder compartment, accessible from the rear of the cubicle by removing the panel or by opening the eventual door. D Busbar compartment This compartment contains the main bus-bars which are directly supported by the lower fi xed isolating contacts of the circuit-breakers and isolator supports fi xed on the structure. E Wiring duct for interconnections On the cubicle roof front side, a wiring duct is provided to hold the auxiliary connections between the various cubicles and towards the external installation. F Voltage transformer compartment (VT compartment) This compartment can contains the fi xed or draw-out version voltage transformers and the related fuses The draw-out version allows VTs and fuses replacement in safe conditions even with switchbord on voltage. This compartment can be located in incoming or outgoing feeder cubicles as well as in bus tie cubicles. The device could be provided with auxiliary switches for signalling the racking-in and racked-out position. G switch The unit can be equipped with Casagrande Elettrocostruzioni CE-SEZ earthing switch. The switch is activated with an high speed rotating snap, sized to conduct the rated short circuit making current when close to under load. The speed of the snap action closing operation is independent of controls. A manual switch operating lever is provided on the front of the switchbord. The device is provided with auxiliary switches for signalling the open and closed positions. H Gas exhaust duct (Optional) The gas exhaust duct, positioned on the top of the cubicles, collects and ejects outside the safety area the gas resulting by the eventual internal arc fault. switch Mechanical lock to prevent the earthing switch closing if the circuit-breaker is in connected position On the circuit-breaker Mechanical lock to prevent the connection or disconnection of the circuit breaker when closed Mechanical lock to prevent the circuit breaker connection when the earthing switch is in closed position Mechanical lock to prevent the disconnection of auxiliary connector with circuit breaker in connected position Mechanical lock to prevent the manual opening of the shutters when the circuit breaker is removed from the compartment. The shutters can only be operated by the circuit breaker truck. Mechanical protection (IP20) form live parts even with door open is always maintained with circuit breaker in connected and disconnected position. On the VT s compartment (if present) Mechanical lock to prevent opening of the door when VTs are in connected position. Mechanical lock to prevent the manual opening of the shutters when the VTs are removed from the compartment. The shutters can only be operated by the VTs truck. 8 9
VERSIONS AND CONFIGURATIONS Key lock permitting the key to be released with earthing switch open and locked in open position Electromechanical lock to prevent closing of earthing switch Mechanical lock to allow door opening only if circuit breaker Optional TYPICAL UNITS Special Versions Environment For special environments and temperature For indoor use with protection degree up to IP54 For outdoor use in metal box up to IP56 or NEMA 4X is in disconnected position Padlock facility on circuit breaker shutters in closed position Padlock facility to prevent circuit breaker connecting or disconnecting movement Padlock facility to prevent opening or closing of earthing switch Connection Padlock facility on circuit breaker door Incoming/outgoing by cables form the TOP Incoming/outgoing by bus duct form the TOP Command Motorized command for draw-out / draw-in circuit breaker trolley Options and accessories Available Locks Key locks permitting the key to be released with Circuit Breaker locked in open positions Key locks permitting the key to be released with Circuit Breaker locked in disconnected position Key locks permitting the key to be released with circuit Motorized command for earthing switch Accessories Light or pressure device to limit internal arc fault duration Circuit breaker trolley for handling when removed from the compartment Contactor trolley for handling when removed from the compartment breaker door closed Handle for circuit breaker / contactor connecting or Key lock permitting the key to be released with earthing disconnecting movement switch closed and locked in closed position Handle for earthng switch command Example of confi guration 10 11