STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

Similar documents
ATHLETIC STADIUMS AND SPORTS ARENAS

STABILOY BRAND FeeDeR SOLuTIONS

Primary, Secondary, Post-Secondary Education Facilities

HOSPITAL AND HEALTHCARE

RENEWABLE ENERGY. Alcan cable solutions

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs


The Reliable Choice. Field Pocket Guide

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

NEC 2014 Code Changes

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

TC-RHH/RHW-2 USE-2 Copper

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Variable Frequency Drive (VFD) Cable Solutions

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

MC, THHN/THWN-2 Copper

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

Wired for Power Generation

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

Mecklenburg County Common Code Defects

Medium Voltage Power Cables

SECONDARY 600 VOLT CABLES

TUNNELING POWER CABLES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Section 02: Pre-Installation Procedures

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

MC or MV-105 Copper, TR-XLPE Insulated

Variable Frequency Drive (VFD) Cable Solutions

PART A General Conductor Requirements

MEDIUM VOLTAGE

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

Section 8. Portable Cordage & Power Cable

Code Calculations. for an Off-Grid PV System

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

C-L-X Aluminum Sheath Type IEC

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

CHAPTER V RESIDENTIAL WIRING

KALAS ENTERTAINMENT CABLE

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

HW250 REV 8/16 TYPE SOOW. 600 Volt UL/CSA, -40 C to 90 C Black Jacket Flexible Copper Conductors

E R C. R E R C ; ; W T E C

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Introducing. Paralleled

Easier! Faster! Safer!

A. Submit manufacturer's literature and technical data before starting work.

High Voltage Copper, Smooth Aluminum Shield/Sheath

IEEE 1580 TYPE T/N CABLE

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Category # 1 - Overhead, Primary, & Secondary Conductors

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

Busway Construction. Bus Bars

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

2016 Photovoltaic Solar System Plan Review List

Electrical Design/Build Guide

Battery Cables. Wire & Cable

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

PHOTOVOLTAIC SYSTEMS

ANSI/NEMA WC ICEA No. S Portable and Power Feeder Cables for Use in Mines and Similar Applications

Connector Installation Guide Compression and Mechanical Connectors

ELE CTR IC UT ILI TY

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Generator Fire Safety: Generator assemblies should be located outside the building.

New Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Photovoltaic Solar Plan Review

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018

Protecting the oil & gas industry for more than half a century!

Automotive Cables. The Global Cable Solutions Company

Detailed Specifications & Technical Data

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

Microlectric Meter Sockets. Smart solutions that save you time and money

SINGLE PHASE WIRING SPECIFICATIONS

Spring Test 10 due 05/11/2013

Transcription:

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

Introduction When it comes to feeder cables, General Cable keeps industries of all types humming with cost savings on total installation, shortened installation timeframes and miles upon miles of installed cables. That is why our STABILOY Brand aluminum alloy feeder cables are installed with confidence in a variety of industrial applications in North America including: Aerospace and Defense Automotive Chemicals Electronics and Technology Food and Beverage Metals and Engineered Products Mining Pharmaceuticals Waste Water Treatment Plants The STABILOY Brand of products includes MC Cable, FeederPlex HS XHHW-2 cable, and single conductor WIDESTRIPE HS XHHW-2 cable, which are designed to distribute power throughout the building. Each of these cable solutions provides significant cost savings and reliable performance. STABILOY Brand MC Cable offers a durable interlocked aluminum armor to protect the electrical conductors from damage, while allowing flexibility in construction and design. The all-in-one assembly of MC Cable makes it a cost-effective solution for electrical retrofits in existing buildings. STABILOY Brand single conductor WIDESTRIPE HS XHHW-2, a phase-identified, low coefficient of friction cable, can be used in EMT, PVC or other types of conduit. Our FeederPlex HS XHHW-2 cable is a factory-plexed assembly of XHHW-2 conductors that allows for fast and easy cable pulls while eliminating the need to pull multiple conductors from separate reels. So whether you are installing in conduit or not, STABILOY Brand aluminum alloy feeder cables offer you a safe, reliable and cost-effective solution for distribution feeder applications. Quality is never a question with STABILOY Brand cables. In fact, General Cable tests every foot of every aluminum alloy feeder cable that it manufactures. Each STABILOY Brand single conductor and FeederPlex HS assembly is tested using state-of-the-art AC spark testing technology to ensure product quality. The superior performance of STABILOY Brand aluminum alloy cables has been validated by independent research. The Georgia Power Research Laboratory conducted a study comparing STABILOY Brand feeders to copper conductors. The results of the study show that connections installed on AA-8030 aluminum alloy performed as well as or better than connections installed on copper conductors of equivalent ampacity in the current cycle submersion test. STABILOY Brand aluminum alloy is readily available, infinitely recyclable and is manufactured in an environmentally responsible manner. STABILOY Brand feeders contain no heavy metals and are RoHS* compliant, and the cable jackets are free of lead and cadmium stabilizers. General Cable XHHW-2 insulation provides a longer life than THHN/THWN-2, thereby extending the total life of the installation and reducing waste. There s no question: green construction is the building trend of the decade. However, in today s tough economy, it is crucial to cut costs while considering the environmental impact of our building material choices. By including STABILOY Brand MC Cable in your project specifications, the savings you realize can be used to defray the cost of energy-saving devices and accelerate the payback of your green building. *Denotes compliance to RoHS, Directive 2002/95/EC. For more information on General Cable, please call toll-free at 1-855-720-2792.

APPLICATION STABILOY Brand feeder cables are UL Listed and can be used for services and feeders. Service and feeder conductors to the main distribution center in a variety of industries including: facilities, warehouses, administrative buildings, factory operations and other support buildings. Feeder conductors for power distribution to the panel throughout a variety of building constructions including: wood stud, metal stud, concrete poured and cinder block. Feeder and branch circuits for a variety of specialized equipment and HVAC services. Temporary services for power throughout the construction phase. Our Metal Clad cable with PVC jacket can be used in exterior locations including wet locations and those exposed to sunlight. PROJECTS LIST EnerSys Battery Manufacturing Warrenton, Missouri Caterpillar Hydraulic Excavator Plant Oxford, Mississippi Electrolux Corporation, Plant #2 Memphis, Tennessee Horseshoe Generator Twin Falls, Idaho Cargill Flour Milling Inc. Ogden, Utah Pratt Industries Manufacturing Plant Macungie, Pennsylvania Hilmar Cheese Company Plant Dalhart, Texas SPECIFICATIONS Field Application Engineers are on staff to help you navigate the electrical specification process including takeoffs and voltage drop calculations. FAEs also serve as a resource for specification changes, value engineering proposals and technical questions. To gain the maximum value benefit on your project, specify STABILOY Brand 8000 Series aluminum alloy as an alternative in the Master Electrical Specification. A sample specification is included below for reference. 600-VOLT INSULATED CONDUCTORS A. All branch circuit conductors and feeder conductors 10 AWG and less shall be soft-drawn annealed copper with conductivity of not less than 98% IACS at 20 degrees C (68 degrees F). Conductors greater than 10 AWG copper may be converted to aluminum at the contractor s option. The contractor shall be responsible for increasing the conductor and conduit sizing, if necessary, when aluminum conductors are substituted for copper. The ampacity of the aluminum conductor shall be adequate for the load served and sized appropriately for the overcurrent device. The conduit fill shall not exceed NEC requirements. B. Conductors 10 AWG and smaller shall be solid and conductors 8 AWG and larger shall be stranded. Minimum wire size shall be 12 AWG unless otherwise noted on the drawings. C. All wire and cable shall be permanently marked to indicate size, voltage, type and temperature rating in accordance with NEC Article 310 and applicable product standards. D. Provide factory colored insulation for phase conductors 10 AWG and smaller. Larger insulated phase conductors may be factory identified with an approved field applied tape. E. Aluminum conductors shall be as follows: Type XHHW-2: For dry and wet locations, maximum operating temperature 90 C. The conductor shall be compact stranded AA-8000 series aluminum with black cross-linked polyethylene insulation. The cable shall meet the requirements of Federal Specification JC-30B. The conductor shall comply with ASTM Standards B800 and B801 or B836. ALUMINUM CONNECTORS AND TERMINATIONS A. All connectors and terminations shall be UL Listed for use with aluminum conductors. All connectors and terminations shall comply with UL Standard 486A-B and be marked AL, ALCU, AL7CU or AL9CU for 90 C circuits. B. All connections and terminations shall be made in accordance with the connector or equipment manufacturer s recommendations. C. Tighten electrical connectors and equipment, including screws and bolts, in accordance with manufacturer s published torque tightening values. Where manufacturer s torquing requirements are not indicated, tighten connectors and equipment to comply with tightening torques specified in NEC Annex I.

STABILOY Brand Aluminum Feeder Cable The Value of Aluminum: Superior Conductivity, Insulation & Termination Did YOU Know? STABILOY Brand aluminum feeder cables are the hardest working conductors on the market. Conductivity When it comes to conductivity, aluminum conductors carry twice the current per pound as copper conductors, giving STABILOY Brand aluminum alloy conductors a distinct performance advantage. Insulation STABILOY Brand aluminum alloy conductors feature a superior crosslinked polyethylene (XPLE) insulation that performs better in cold impact, wet locations and long-term aging tests compared to other types of conductors. This makes it a better insulation for every building wire application. Termination STABILOY Brand aluminum alloy conductors terminate safely with industry standard dual-rated aluminum alloy lugs. The similar metals connection eliminates thermal expansion mismatch, which translates into a safe and reliable termination. Quality It s a fact. General Cable tests every foot of every aluminum alloy feeder cable that it manufactures. Because STABILOY Brand aluminum alloy feeder cable is 100% tested for quality its reliability, durability and safety are all guaranteed! Performance High-quality STABILOY Brand aluminum alloy features a unique composition of metals that is specially engineered for superior performance in building feeder applications. Confidence You can rest assured. If aluminum is the utility companies preferred choice for carrying power all the way from the generator to the grid, it s the right choice for the last 100 feet of power delivery feeder cable. Ease-Of-Use STABILOY Brand aluminum alloy feeder cable is much easier to install. Maintenance for STABILOY Brand and copper is equal. This makes it more time-efficient and more cost-effective as well. Value At twice the ampacity per pound, not only is aluminum more cost-effective than copper, but the price of aluminum is much more stable than the price of copper. Sustainability Aluminum alloy is readily available and infinitely recyclable. In addition, STABILOY Brand aluminum alloy conductors are manufactured in an environmentally responsible manner.

Products MC Cable An all-in-one XHHW-2 conductor assembly with phase-identified conductors and a bare equipment grounding conductor. The assembly is a no conduit solution that provides labor and material savings of up to 50% over copper in conduit. STABILOY Brand MC Cable is available with and without a PVC jacket. FeederPlex HS XHHW-2 Factory-plexed assembly of aluminum alloy XHHW-2 conductors with specially designed XLPE insulation that allows for fast and easy pulling. Designed with phase identification for safer connections and delivered on one reel to the job site. STABILOY Brand FeederPlex HS significantly reduces installation time and effort during the pull, and minimizes site management. WIDESTRIPE HS XHHW-2 A single conductor aluminum alloy feeder cable with a specially designed XLPE insulation that allows for fast and easy pulling. Phase identification on the conductor consists of three wide color stripes embedded within the surface of the insulation. The insulation on STABILOY Brand WIDESTRIPE HS (High Speed) XHHW-2 conductors reduces pull force by 42% compared to the installation of regular XHHW-2 using pull lube. STABILOY Brand XHHW-2 A single conductor feeder with cross-linked polyethylene (XLPE) insulation that provides better performance than THHN insulation in hot and cold weather conditions, wet electrical tests, higher short circuit temperatures and long-term aging tests. CASE STUDIES Boeing Building Kent, Washington Why STABILOY Brand? Ease of installation, unique product construction and phase identification of STABILOY Brand FeederPlex HS XHHW-2 and MC Cables delivered total installation cost savings on the replacement of dated cables in the distribution room. Saint Gobain Manufacturing Goodyear, Arizona Why STABILOY Brand? Using STABILOY Brand MC Cable allowed the contractor to shorten the installation time to meet a 120-day completion schedule. Both PVC jacketed MC Cable and unjacketed MC Cable were selected to address complicated design requirements in the reconfiguration of the existing facility. www.stabiloy.com

4 Tesseneer Drive, Highland Heights, Kentucky 41076-9753 GENERAL CABLE and STABILOY BRAND are trademarks of General Cable Technologies Corporation. NEC is a registered trademark of the National Fire Protection Association. 2013. General Cable Technologies Corporation. Highland Heights, KY 41076 All rights reserved. Printed in USA Phone: 1.855.720.2792 1.859.572.8000 Fax: 1.800.547.8249 www.stabiloy.com Form No. BW-0105-0913