VAHLE POWERCOM 485. Digital Data Transmission System

Similar documents
VAHLE POWERCOM 485. Digital Data Transmission System

VAHLE POWERCOM 485. Digital Data Transmission System

BATTERY CHARGING SYSTEMS. for Automatic Guided Vehicles

POWERAIL ENCLOSED CONDUCTOR SYSTEM VKS 10

MACHT STROM MOBIL. Battery Charging Systems

POWERAIL ENCLOSED CONDUCTOR SYSTEM VKS 10

POWERAIL ENCLOSED CONDUCTOR SYSTEM KBH

POWERAIL ENCLOSED CONDUCTOR SYSTEM KBH

COMPACT CONDUCTOR SYSTEMS VKS 10

POWERAIL CONDUCTOR SYSTEMS MKLD MKLF MKLS

Multi Support Profile VMT SYSTEMS IN MOTION

POWERAIL ENCLOSED CONDUCTOR SYSTEMS VKS VKL

INSULATED CONDUCTOR SYSTEMS U10

POWERAIL ENCLOSED CONDUCTOR SYSTEMS KBSL KSL KSLT

Motor Starter Reverse MSR22-FBP

MACHT STROM MOBIL. Spring Operated Cable Reels

ELECTRONIC OVERHEAD TRAVELLING CRANE DIMENSIONS & LOAD DATA

MagFlux Q 8200 Series

GS2 Series - Introduction

Compact Conductor System VKS10 SYSTEMS IN MOTION

RS485 MODBUS Card. User Manual. Before you start to install this card, please read this User Manual carefully

J1000. Compact Inverter Series.

MACHT STROM MOBIL. Enclosed conductor system KBH SYSTEMS IN MOTION

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

USERS MANUAL MCD REMOTE OPERATOR

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Series L9 UL-489 Miniature Circuit Breakers

Operating manual UPS - System

High performance Vector Control. Ratings. System configuration

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Say hello to better web control.

My Reserve 500 Install Guide

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

2.7. IT system floor-standing distribution cabinet Series -IPS-F

1329I Integrated Drive/Motor CE Filter Option Kit

photovoltaikforum.com

Bolted, snap-in and guarter turn type hangers are available. Standard support distance for U12 is 600mm, in curves 300mm.

MACHT STROM MOBIL. Insulated Conductor Systems U10

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Exportinitiative Energie

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Step 1: Collection of required data

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

Energy Supply Systems

ALIANT ULTRALIGHT BATTERY is a product by ELSA Solutions S.r.l

MP-Series Integrated Gear Motors

Power Supplies. 11/2 Introduction

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive


BR Second Position Voltages. AA Fourth Position

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

VAHLE MOTOR POWERED CABLE REELS

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

MACHT STROM MOBIL. Enclosed conductor system KBH SYSTEMS IN MOTION

HQST 500W (12V) HQST 1000W (12V) Modified Sine Wave Inverter. User Manual

Uninterruptible Power System

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

Series L9 UL489 Miniature Circuit Breakers

Delta Products VFD CP2000 Bypass Control Packages.

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Motor protection switches M16 20A Main switches S25 25A

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

Mobility & emobility

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)

Hydraulic power unit CE8L Technical data

Level and Flow Measurement. Sludge Finder 2

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Aircraft Cable Management Systems

MX1S Matrix Converter

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

Automated Precision Weighing

Rotary Disconnect Switches, Bulletin 194R

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

2006/2007 Product Catalog. The World s Leading SOLAR Controllers

Product Overview Festoon-Systems for I-Beams

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

INTECH Micro 2300-RTD6

2 SLR Series Line Reactors... 50

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

MICRO MASTER MICRO MASTER Vector MIDI MASTER Vector

ELECTRIFICATION OF RTG CRANES

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Transcription:

VAHLE POWERCOM 485 Digital Data Transmission System

19 12 VAHLE POWERCOM 485 GENERAL INFORMATION VAHLE POWERCOM 485 Digital Data Transmission using VAHLE Conductor Systems VAHLE POWERCOM 485 is the latest development of the well-known VAHLE POWERCOM data communication systems, first introduced in 1984. It was especially designed for RS 485 based industrial data bus systems and operates at a data rate of 19.2 Kbit/s. With new generation electronic components the dimensions of the VAHLE POWERCOM 485 could be substantially reduced and the top-hat rail housing comprises the necessary power supply equipment. The compact design simplifies installation, e.g. on electrical overhead monorails. VAHLE POWERCOM 485 has on its front an integrated transparent RS 485 interface in accordance with PROFIBUS, below the power supply 230 V, 50 Hz, or alternatively 115 V, 60 Hz, and the 2-pole connection for the conductor system. Three-status LED inform about the status of the unit. VAHLE POWERCOM 485 provides safe communication for RS 485 industrial data bus systems using VAHLE conductor systems up to 5000 m length, including switches, turntables, lifting stations etc. The data rate is 19.2 Kbit/s with an internal delay of max. 3 bits. It can be used for point-to-point transmission and for bus systems with up to 31 partners. A variety of system layouts is possible, including transfers, isolating sections etc. VAHLE POWERCOM 485 is the ideal communication link for electric overhead monorails, straight and curved AS/RS systems, slipring bodies and other track-guided material handling equipment. All VAHLE conductor systems can be used together with VAHLE POWERCOM 485. For the implementation of data systems with higher transmissioin speeds up to 10 Mbit/s and other industrial data bus systems we recommend our SMG (Slotted Microwave Guide). Applications: Cranes AS/RS Systems Transfer Cars Electric Monorail Systems Motorized and Spring Driven Reels VAHLE POWERCOM 485 Block diagram 2

VAHLE POWERCOM 485 TECHNICAL DATA 19 12 Technical Data: Transmission network: half duplex (HDx) Transmission speed: 9.6, 19.2 Kbit/s. Number of stations: max. 31 stations Suitable networks: Profibus-DP and FMS, EN 50 170 Vol. 2 PPI (Point to Point Interface) MPI (Multipoint Interface) Modbus Suconet-Bus Uni-Telway Allen-Bradley DH 485 and all other RS 485 Networks with 11 or 10 bits/byte Data line (VPC 485 PLC): Shielded twisted pair data line (as recommended by the PLC manufacturer) Data line (VPC 485 conductor rail system VPC 485): Shielded power cable (2 x 2.5 mm 2 ) Indications: Status check for POWER, RX and TX Supply voltage: 230 V, 50 Hz alternatively 115 V, 60 Hz Voltage drop: ± 10 % max. Operating temperature: 20 to + 50 C, 4 to 122 F Storage temperature: 0 to 70 C, 32 to 158 F Enclosure dimensions: 85 x 117 x 110 mm (W x H x D) Mounting position vertical, ventilation slots at the top and at the bottom, minimum clearance to other modules 30 mm Protection against direct contact: IP 20 Weight: 1.1 kg Mounting: Back side to top-hat rail EN 50-022-35. Cat.-No. Profibus 19.2 Kbit/s, 230 V: 910 108 Cat.-No. Profibus 19.2 Kbit/s, 115 V: 910 109 Other versions on request. Circuit Diagram VAHLE POWERCOM 485 3

19 12 ACCESSORIES Filter for VAHLE POWERCOM System Prevents interference from reaching the data network and prevents data from travelling into the remaining network Current: Voltage: Dimensions: Weight: 6 A max. (fuse) 230 VAC 152 x 73.2 x 121 mm (W/H/D) 1.3 kg Plastic housing Order No.: 910 080 Power supply limit for VAHLE POWERCOM System To isolate the data circuit from site related interference if the use of our 6 A double filter is not possible. Power supply: Voltage: Dimensions: Weight: 6A 230 VAC 48 x 95 x 57 mm 0.150 kg Order No.: 910 032 Cables and connectors available on request. Installation Information: For systems with frequency converters, it is important to follow the unit manufacturer s instructions, especially with measures against interference, cable support and cable shielding. Data cables must be separated at least 100 mm from the power cables. VAHLE POWERCOM -data transmission for coil transport system in an aluminium plant. 4

APPLICATIONS 19 12 VAHLE POWERCOM -data transmission at a brick kiln. VAHLE POWERCOM -data transmission for Lufthansa hangar gates, Hamburg. 5

19 12 APPLICATIONS Vahle conductors U 30 / 130 CH VAHLE POWERCOM -data transmission for an asphalt testing installation Track Layout 6

VAHLE POWERCOM QUESTIONAIRE 19 12 To our nearest local agent Company address: Contact person: Date: 1. What computers or PC s will be used for the data communication? a) Stationary: b) On the moving machinery: 2. Which computer interfaces are used? a) RS 232 b) TTY c) RS 485 Others (specify) 3. What data speed is required? baud 4. Data transfer a) Serial b) Full duplex c) Semi duplex 5. Data transfer by means of a) Data conductors 230 Volt (zero phase) b) Data conductors other voltage 6. What other units will also be supplied by the data conductors? a) POWERCOM b) Computer c) Fan d) Lights e) Others, Please specify in detail: 7. What vehicles or units are to be provided with data? a) Crane b) Travelling platform c) AS/AR Systems d) Overhead monorail e) Others, Please specify in detail: 8. What VAHLE current conductor system is used? Heated 9. Length of travel distance: m, Travel speed: m/s 10. How many vehicles will be supplied with data? 11. Will several vehicles use the current conductor system simultaneously? a) If yes, how many? b) No c) No we have vehicles that communicate with a central computer, but run on different current conductor systems. 12. Ambient temperature: C min., C max. 13. What are the environmental conditions? a) Outdoor installation b) Dust c) Acid d) Indoor installation e) Humidity f) Oils g) Others, Please specify in detail: Comments: In accordance with our company s policy of continued improvement, we reserve the right to amend specifications and details at any time. 7

Catalog No. 9c/E 2001 Reg. No. 3140 Catalog No. Copperhead Conductor Systems 1 a Battery Charging Systems 1 b Insulated Conductor Systems U 10 2 a Insulated Conductor Systems U 20 U 30 U 40 2 b Insulated Conductor Systems U 15 U 25 U 35 2 c Aluminium Enclosed Conductor Systems LSV LSVG 3 a Steel Enclosed Conductor Systems SLG HSL 3 b Powerail Enclosed Conductor Systems KBSL KSL KSLT KSG 4 a Powerail Enclosed Conductor Systems VKS VKL 4 b Powerail Enclosed Conductor System MKLD MKLF MKLS 4 c Heavy Enclosed Conductor Systems 5 Trolley Wire and Accessories 6 Cable Tenders 7 Cable Carriers for -tracks 8 a Cable Carriers for Flatform Cable on -beams 8 bf Cable Carriers for Round Cable on -beams 8 br Cable Carriers for -tracks 8 c Conductor Cables and Fittings 8 L Spring Operated Cable Reels 9 a Overload Protection Systems 9 b VAHLE POWERCOM Data Transmission Systems 9 c CPS Contactless Power Supply 9 d SMG Slotted Microwave Guide 9 e Motor Powered Cable Reels 10 0011 Printed in Germany 2000-3550 1000 1/01 PAUL VAHLE GMBH & CO. KG D 59172 KAMEN/GERMANY TEL. 0 23 07/ 70 40 Internet: www.vahle.de e-mail: postmaster @ vahle.de FAX 0 23 07/ 7 47 04