Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

Similar documents
DC One Automatic Sliding Door Retrofit

DC Low Energy Swing Door Operator

Setup and Programming Manual

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02

USERS GUIDE LO-21U LOCKOUT RELAY

BODYGUARD III-C USER S GUIDE

Senior Swing Control Box. Table of Contents

SW10 (Full Power) & SW19 (Low Energy)

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Gate & Door Controller with LCD and Intelligent Technology

INSTALLATION GUIDE For Surface Mounted Applications (Purchased after 08/01/2018)

QUADSCAN User s Guide Door Mounted Presence sensor

AUTOMATIC ENTRANCES SLIDING GILDOR, INC. SECTION [08460] MODEL SLM SERIES TYPE COM

ED900. Low energy operator. Customizing Features: Book 3 of 3

Roll Up Door Operator

DYNATECH D-BOX UNINTENDED CAR MOVEMENT CONTROL SYSTEM DYNAMICS AND TECHNOLOGY, S.L.

Read Chapter 8 Servicing Machine in the Manual for general guidelines

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

INSTALLATION GUIDE Table of Contents

COOKSON OWNER'S MANUAL

RR Concepts. The StationMaster can control DC trains or DCC equipped trains set to linear mode.

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

1.0 Features and Description

Door Position System USER S GUIDE

EXTREME R MOTOR OWNER'S MANUAL

JBI Docupunch P33 Automatic Punch

SAFE AND SECURE EXTREME R MOTOR OWNER'S MANUAL MODEL PRO-FDG FOR TECHNICAL SUPPORT PLEASE CALL 1-(855) OPERATOR SERIAL#

EB Conveyor Maintenance Guide

Operations Manual Eagle 1000 Series Stretch Wrapper

DP K9 Door Popper Installation Manual. Patented

ELD DRIVER GUIDE June 21, 2018

DETEX Low Energy Automatic Door Operator AO19-1 Single Door - Push

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

ED50. Low energy automatic swing door operator. Service Manual

HIGH SPEED SLIDING GATE OPENER

Best Diversified Products, Inc. Product Manual. BestReach Rigid Belt. Models BRB 230 OS BRB 230 SS BRB 460 OS BRB 460 SS

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

ECONOMISER SERIES E2T USER MANUAL

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Universal Wireless Dashboard Y-Dash + Android App Y-Dash GT. User Manual Firmware version 1.6 Software version 2.28 Hardware version 1.

NOTE. Installation and Service Manual Dual Planetary Gearmotor Slim Rack Slide Out System

WS2H/ WS3 Error Codes

Installation Manual. Door Automation. Leading the way...

Service Manual. Extractor Model XR28QP. For The. For: Troubleshooting Adjustments

Troubleshooting Guide

XR Conveyor Maintenance Guide

Dor-O-Matic. Series Slide Control. Installation Instructions

Flight Systems. Replacement for KASSEC DESCRIPTION

What s on your truck? MOTIONACCESS, LLC. Installation & Operation Manual

ESA II CONTROLLER AND WIRING MANUAL

OPERATING MANUAL. A5 MIG Orbital System

Door Position System USER S GUIDE

KEANE MONROE a member of the record group

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

6100 Series Swing Door Operator Installation Instructions

Allegion LCN Benchmark AU9100 Series

CENTRIFEEDER ELECTRONICS

Thunder Power Tarp Kit Operation. Dual Arm Curb Side Stowing Single Arm Curb Side Stowing Flex Arm Curb Side Stowing.

Wiring Main Power connector constant 12V power

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT.

TERMINATOR User Manual

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

USERS GUIDE BODYGUARD III SMR PRESENCE SENSOR

EC DECLARATION OF CONFORMITY

Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

Service Manual Gulf Stream Electronic Full Wall Slide Systems

Maintenance Guide AZTEC BNF-2000 BILL ACCEPTOR PRIMARY COMPONENT PARTS

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Application Engineering Europe

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax:

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

Document ID# Buick LeSabre

IMPORTANT. Motion Control Engineering New York Office nd Drive, Unit F Glendale NY (718) O. Thompson M00352 Limit Board

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

ECCII to ECCIII Upgrade Kit

TC1000 Service Manual SALES: CUSTOMER SERVICE:

Installation and User Manual. with RAIN SENSOR.

MA-4025 Solar Charger Patent pending

POWERLINE 2000 Energy Management System TM

Contents Getting Started with PrePass ELD...4 Starting a Trip...7 During a Trip Co-Driver Features... 14

2001 Chevrolet Corvette ACCESSORIES & EQUIPMENT Cruise Control Systems - Corvette

DLF-220L Digital Label Finishing System

Installation & Service Manual

SE-600-P Eco-Series. Operation & Parts Manual

Customer Name. Instruction for Operation. Single Head Sleever

Digital Diesel Control Remote control panel for GENVERTER GV4 and GV7i

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

OPERATOR TROUBLESHOOTING GUIDE

Alternative Fuel Engine Control Unit

Service Manual. For the SCV2832E, SCV2426, Automatic Scrubbers For: Training Troubleshooting

MX-T3x(TM94E) AC SYSTEM SERVICE MANUAL

INSTALL GUIDE DIR-CH(RS)-CH8-[FLRSCH10]-EN

AgriWheel Single Gate Kit Low Voltage & Solar. Installation & Operating Instructions

TOSHIBA Thermal Printer B-852-R SERIES. Maintenance Manual. Document No. EO Original Mar., 2006 (Revised ) PRINTED IN JAPAN

Transcription:

Automatic Sliding Door Retrofit Drive Assembly Installation Manual 800-437-3667 DoorControlsUSA.com

TABLE OF CONTENTS pg. 1. COMPONENTS 2 2. HEADER PREPARATION 2 3. DOOR PREPARATION 2 4. MOTOR AND CONTROLLER INSTALLATION 2 5. WIRING OF ACCESSORIES 3 6. DRIVE BELT AND BRACKET INSTALLATION 3 7. CONNECTING POWER 3 8. WALK TEST 3 9. SAFETY TEST AND DOCUMENTATION 4 10. CONTROL LAYOUT 4 11. I/O CONNECTOR LAYOUT AND DESCRIPTION 5 12. HOW TO ENTER PROGRAM MODE 6 13. MENU DISPLAY SCREENS 7 14. PART NUMBERS 12 15. TECHNICAL SPECIFICATIONS 12 16. WARRANTY TERMS 12 17. TROUBLE SHOOTING TIPS 13 18. WIRING DIAGRAMS 14 DC One V3 Installation Manual Page 1 of 15

NOTE: Approimate installation time: 2 to 4 hours 1 Technician. 1. COMPONENTS Motor / Gearbo (1) Control (1) Drive Belt (1) Optional on some systems Belt Brackets (2) Idler / Tensioner (1) When required Decal Set (1) AAADM Owner s Manual (1) AAADM Daily Safety Check Decal (1) OPTIONAL: Bottom Guides (1 or 2) Top Rollers (2 or 4) 2. HEADER PREPARATION WARNING Shut off and disconnect all primary electrical power to the door header before proceeding any further. Disconnect all sensor wiring from the control and/or interface board. Keep the wiring available if you intend to re-use the sensors Disconnect all safety beam wiring from the control and/or interface board. Keep the wiring available if you intend to re-use the safety beams. Disconnect all switches from the control and/or interface. Keep the switches in place if you intend to re-use them for the retrofit. Remove the entire eisting drive system from the header (motor/gearbo, control, interface, belt, chain, cables, etc.). Do not throw away any mounting hardware as it may be used to mount the DC One components (see drawings). BOX CORES and USED COMPONENTS (motor/gearbo, control, etc.) use the return shipping label and ship to Door Controls. 3. DOOR PREPARATION Remove and replace the bottom guides (If needed). Remove and replace top rollers (If needed). IMPORTANT NOTE: Manual resistance of the sliding panels, with no belt attached, should not eceed 8 lb for bi-parts, or 4 lb for single slides. Use a force gauge to push against the door to slide it open and closed to check the resistance. Be sure to check for mechanical door stops at each end of the header. If door stops are missing, they may be ordered as an accessory from Door Controls. Do not install new belt brackets yet, this will allow more working room when installing the control and related wiring. 4. MOTOR AND CONTROLLER INSTALLATION Install DC One motor/gearbo and controller per the instructions shown on the enclosed drawing. DC One V3 Installation Manual Page 2 of 15

5. WIRING OF ACCESSORIES Complete all wiring. Refer to the wiring diagrams in Sections 11 and 18. Be sure to complete the wiring for any accessories that may be required as well: Activation Sensors Safety Sensors Safety Beams On-Off Switch Emergency Breakout Switch Electric Carriage Lock (accessory) Reduced Opening Switch (accessory) 1-Way Switch (accessory) 6. DRIVE BELT AND BRACKET INSTALLATION Upon completion of all wiring, the drive belt, related brackets and idler pulley may be installed. Refer to the detailed dimensions drawing that came with the package to determine all mounting locations. When complete, install the drive belt and tension to result in approimately 1 to 2 deflection overall up and down at the center of the greatest span between clamp and pulley. The belt may need to be cut to the correct length. Use a strong pair of wire cutters to make a clean cut. Check to make sure there are no wires that could be potentially caught by the moving parts. With the belt installed and tensioned, move the doors manually to their full open and then full closed position and ensure that they slide without binding or obstruction. 7. CONNECTING POWER Connect and apply main power to the control. Perform a factory reset Refer to Sections 12 and 13. Press the TEST button on the DC One control to trigger an activation cycle. When the learn cycle is complete, normal operation will resume according to default values set in the control. Fine-tuning of the control may be necessary at this point. Other than door handing and breakout polarity, the most common adjustments are for speed, force and time. Although there are more adjustments if needed. See Sections 12 & 13 for further instructions. 8. WALK TEST Check all functions to ensure proper operation REMEMBER Even if a door is designated for 1-way traffic, a secondary activation sensor is still required at the side not intended for approach. The activation zone must etend to at least 24 out from the face of the door With the door switch off, make sure the doors are fully closed. Check alignment of doors for proper weather-seal and ensure that door locks properly Use walk-test aides such as the dimensional mat shown below, to help outline key distances for testing sensor patterns DC One V3 Installation Manual Page 3 of 15

9. SAFETY TEST AND DOCUMENTATION When all DC One and sensor adjustments are complete, perform a thorough safety test to validate proper and safe performance in accordance with current ANSI A156.10 guidelines as well as recommendations prescribed by the American Association of Automatic Door Manufacturers (AAADM). Door Controls USA recommends this step be performed by an AAADM certified door inspector. Walk toward the door at a normal pace. The door should open when you are about 4 feet from the door. Stand motionless on threshold for at least 10 seconds. The door should not close. Move clear of the area. The door should remain open for at least 1.5 seconds and should close slowly and smoothly. Repeat steps 1 through 3 from the other direction if door is used for two way traffic. Inspect the floor area. It should be clean with no loose parts that might cause the user to trip or fall. Keep traffic path clear. Inspect door s overall condition. The appropriate signage should be present. Have door inspected by an AAADM certified inspector at least annually. DO NOT USE DOOR if it fails any of these safety checks or if it malfunctions in any way. Be sure to place an AAADM Daily Safety Check decal on the door (usually near the On-Off switch). Document all work, obtain signatures on all work orders, and instruct the owner on door operation. Be sure to leave a copy of the AAADM Owner s Manual for sliding doors with the owner or facilities manager. 10. CONTROL LAYOUT A B C D E F G H I J T S R Q P O N M L K A. Transformer B. Transformer Connector C. Power Connector D. Status LEDs E. Display Screen F. Parameter Adjustment Knob G. Encoder Status LEDs H. Encoder Connector I. Sensor Connector J. Multifunction Switch Connector K. Special Modes Connector L. Lock Connector M. Test Button (activates door) N. Program Button O. Down Button P. Up Button Q. Reset Button R. Lock Voltage S. Display Intensity T. Motor Connector DC One V3 Installation Manual Page 4 of 15

11. I/O CONNECTOR LAYOUT AND DESCRIPTION J6 J7 1 Common + 1 Common + 2 Off 2 Emergency Open 3 One Way 3 Common + 4 Partial Open 4 Ratchet 5 Hold Open 5 Common + 6 Reset 6 Activation 7 24 VAC 7 Common + 8 24 VAC Return 8 Breakout 9 Common + 9 Common + 10 Safety 10 Night Mode J5 J8 1 24 VAC 1 DC One Lock 2 24 VAC Return 2 DC One Lock 3 Common + 3 DC One Lock 4 Inner Sensor 4 DC One Lock 5 24 VAC 5 DC One Lock 6 24 VAC Return 6 DC One Lock 7 Common + 7 NC 8 Outer Sensor 8 NC 9 Safety 9 NC 10 Common + 10 NC J6 Multifunction Switch Pins 1 to 6 Compatible with DC position switches o 5PSW1 5 position knob o 5PSW2 5 position key o 6PSW1 6 position knob o 6PSW2 6 position key Off o Disables ratchet, inner sensor and outer sensor inputs o Locks door if lock is present o Control on LED will turn off One Way o Disables outer sensor in closed position o Yellow LED is on when active Partial Open o Door will not fully open o Width is adjustable in menu o Yellow LED is on when active Hold Open o Holds the door in the open position o Green LED is on when active Reset o Resets position values o Door will relearn on net activation o Yellow LED is on when active DC One V3 Installation Manual Page 5 of 15

J6 Safety Beams Pins 7 to 10 Activates the door ecept when in the closed position 24 VAC power to safety beam module Red LED is on when active J5 Inner and Outer Sensors Separate 24 VAC connections for sensor power Inner Sensor o Activates door ecept when off or in night mode o Green LED is on when active Outer Sensor o Activates door ecept in off, one way, or night mode o Green LED is on when active Safety o Activates the door ecept when in the closed position o Red LED is on when active J7 Special Modes Emergency Open o Activates the door during all modes o Green LED is on when active Ratchet o Activates door and stays open until ratchet is pressed again o Does not activate during off, one way, or night mode o Green LED is on when active Activation o Activates the door during all modes o Green LED is on when active Breakout o Stops door motion o Software selectable polarity (NO/NC) o Red LED is on when active Night Mode o Disables inner and outer sensors in closed position o Door activates with emergency open and activation input only (pin 2 or 6 of J7) o Yellow LED is on when active J8 Lock 12. HOW TO ENTER PROGRAM MODE Pins 1 to 6 are used to control the DC One lock Lock voltage is selectable between 12 and 24 volts with toggle switch See wiring diagrams for detailed information Press both the RESET and the PROGRAM button. Release the RESET button and continue to hold the PROGRAM button After the display changes, release the PROGRAM button You are now in program mode. After making changes, press RESET to eit program mode The control will perform a learn cycle on the first activation after a reset DC One V3 Installation Manual Page 6 of 15

13. MENU DISPLAY SCREENS Pressing the up button will cycle through the menu in the following order. Factory default settings are shown, following a reset. Turning the parameter adjustment knob will change the values for that setting. Door Position Encoder Counts DOOR POSITION 00258 act sf ro bo 0 X Y Status Encoder Pulses This is a status only screen that gives the following information: Encoder Counts shows the actual encoder count relative to door position Encoder Pulses toggles between upper and lower case as encoder pulses are received Status toggles between upper and lower case as status changes o act/act Activation o sf/sf Safety o ro/ro Reduced open o bo/bo Breakout State shows the state of the controller o 0 Closed o 1 Opening o 2 Open Deceleration o 3 Open Check o 4 Open o 5 Closing o 6 Close Deceleration o 7 Close Check o B Boost Mode o L Learn Mode o O Obstruction Life Cycle Counter LIFE CYCLE COUNT 00000000 Indicates the total number of door cycles on the control Non-resettable Trip Cycle Counter TRIP CYCLE COUNT 00000000 Indicates the number of cycles since the trip counter was last reset DC One V3 Installation Manual Page 7 of 15

Trip Counter Reset RESET TRIP COUNTER Resets the trip counter Resettable in program mode only Faults Detected Lists the fault that the control is currently under o None o Broken or Loose Belt o Jammed Door o Obstruction Lockout Control will remain in hold open after 3 consecutive obstruction errors Control must be reset or turned off to clear error Off is preferable to prevent a relearn cycle after a reset Learn Torque Learn Open Speed Learn Close Speed Motor Type Ranges from 5 to 100% Ranges from 5 to 100% Ranges from 5 to 100% Phone Number DOOR CONTROLS 800-437-3667 Software Version FAULTS DETECTED NONE LEARN TORQUE 020.5% LEARN OPEN SPEED 014.8% LEARN CLOSE SPEED 014.8% SELECT MOTOR TYPE DC ONE V3 DC ONE V3 FIRMWARE V 1.15 DC One V3 Installation Manual Page 8 of 15

Open Speed Close Speed Ranges from 5 to 100% Ranges from 5 to 100% Open Check Speed Close Check Speed Boost Speed Open Deceleration OPEN SPEED 056.3% CLOSE SPEED 020.9% OPEN CHECK SPEED 012.0% Ranges from 5 to 100% CLOSE CHECK SPEED 012.0% Ranges from 5 to 100% BOOST SPEED 030.1% Acceleration from a stopped position to check speed Ranges from 5 to 100% OPEN DECELERATION 030 Adjusts the transition between open and open check Higher values cause a more abrupt change between the two speeds Ranges from 0 to 255 Close Deceleration CLOSE DECELERATION 030 Adjusts the transition between close and close check Higher values cause a more abrupt change between the two speeds Ranges from 0 to 255 DC One V3 Installation Manual Page 9 of 15

Open Torque OPEN TORQUE 072.0% Ranges from 0 to 100% Close Torque CLOSE TORQUE 072.0% Ranges from 0 to 100% Open Check Torque OPEN CHECK TORQUE 014.8% Close Check Torque Open Check Size Ranges from 0 to 100% CLOSE CHECK TORQUE 014.8% Ranges from 0 to 100% Close Check Size OPEN CHECK SIZE 10" Ranges from 3 to 18 Reduced Open Size CLOSE CHECK SIZE 05" Ranges from 3 to 18 Hold Open Time REDUCE OPEN SIZE 16" Ranges from 12 to 72 in 4 increments HOLD OPEN TIME 3s Ranges from 1 to 30 seconds DC One V3 Installation Manual Page 10 of 15

Door Braking Handing DOOR BRAKING OFF Should only be turned on for heavy doors RIGHT HAND DOOR Sets the door to either right or left hand mode Lock Type Breakout Polarity FAIL SECURE LOCK Sets the lock type to either secure or safe, auto detects DC One lock Lock Delay BREAKOUT POLARITY NO Configures breakout for either normally open (NO) or normally closed (NC) contacts Load Factory Defaults LOCK DELAY OFF When enabled, there will be a delay of 1 second between activation and when the door panels move to allow the lock to clear the door path LOAD FACTORY DEFAULT Pressing the program key will reset all settings to factory default DC One V3 Installation Manual Page 11 of 15

14. PART NUMBERS Control Motor Power Cord Transformer* Belt Lock** * Included with control ** Optional DC1-CONTROL DC1-MOTOR DC1-POWER CORD DC1-TRANSFORMER DC1-BELT DC1-LOCK FAIL SAFE or DC1-LOCK FAIL SECURE 15. TECHNICAL SPECIFICATIONS Power Input Power Consumption Secondary Power Supply Drive Train Control Maimum Door Weight Operating Environment 120 Volts AC, Single Phase 150W Ma. 24 Volt, 1A Ma. Molded Brushed DC Motor with Gear Reduction Assembly Microprocessor Controller 400 lbs (200lbs per panel for bi-part) -4F to 158F (-20C to +70C) 30% to 85% Relative Humidity 16. WARRANTY TERMS 1 Year from date of purchase from Door Controls USA, Inc. DC One V3 Installation Manual Page 12 of 15

17. TROUBLE SHOOTING TIPS Before wiring any sensors into the DC One control, it is a good idea to apply power and test the door to ensure it will power open and closed when the TEST button is pressed. Use caution during this test as the sensors will not be operational The following inputs have status LEDs to help identify problems: Power Safety Control On Inner Sensor Door Locked Outer Sensor Heartbeat Emergency Open One Way Ratchet Partial Open Activation Hold Open Breakout Reset Night Mode The heartbeat LED should be blinking. If not, cycle power on the control. If the heartbeat LED is still not blinking, the control is malfunctioning and should be replaced. If programming of the control is unsuccessful, it is easiest to restore the default values and then start over, rather than trying to correct any faulty programming. When power is applied, the door powers open and stays open. Motion or presence sensor output is being held (closed circuit). If unsure which sensor, unplug one by one until fault is isolated. Correct as necessary. Safety beam is blocked or is faulty. Correct as necessary. Door handing is set incorrectly. Enter program mode and change hands. Door powers closed and then stay closed. Press the TEST button on the face of the DC One control. Door should power open and then close. If it does not open, door handing is set incorrectly. Enter program mode and change hands. Door will not open or close. As a first step, always check the DC One digital display for error messages and proceed accordingly. Breakout switch is not wired properly. If red light is on for breakout function on I/O interface, it means that the control is in a breakout condition. Check to ensure breakout polarity is set correctly. On/Off switch is not wired properly or it is in the off position. If the switch is in the on position, the green LED to the left of the display will be on. Important Upon completion of your retrofit, ensure all functions of the door perform satisfactorily. Walk-test the door according to AAADM recommended guidelines and correct all discrepancies, if any, before leaving the job site. DO NOT compromise proper performance. If repairs cannot be immediately made, shut the door OFF and inform the owner of any special instructions and corrective actions. Contact Door Controls USA for further technical support when needed: Door Controls USA, Inc. 321 VZ County Road 4500 Ben Wheeler, TX 75754 Phone: 1-800-437-3667 Fa: 1-800-356-8858 Email: Parts@DoorControlsusa.com DoorControlsUSA.com DC One V3 Installation Manual Page 13 of 15

18. WIRING DIAGRAMS ON / OFF Switch ON / OFF / HO Switch ON OFF J6 1 Common + 2 Off 3 One Way 4 Partial Open 5 Hold Open 6 Reset 7 24 VAC 8 24 VAC Return 9 Common + 10 Safety OFF ON HO J6 1 Common + 2 Off 3 One Way 4 Partial Open 5 Hold Open 6 Reset 7 24 VAC 8 24 VAC Return 9 Common + 10 Safety ONE WAY Switch 5PSW1 & 5PSW2 ON OFF J6 1 Common + 2 Off 3 One Way 4 Partial Open 5 Hold Open 6 Reset 7 24 VAC 8 24 VAC Return 9 Common + 10 Safety 1 2 3 4 5 6 J6 1 Common + 2 Off 3 One Way 4 Partial Open 5 Hold Open 6 Reset 7 24 VAC 8 24 VAC Return 9 Common + 10 Safety 6PSW1 & 6PSW2 DC One Lock 1 2 3 4 5 6 J6 1 Common + 2 Off 3 One Way 4 Partial Open 5 Hold Open 6 Reset 7 24 VAC 8 24 VAC Return 9 Common + 10 Safety 1 2 3 4 5 J8 1 Ground 2 Lock State 3 Door Locked 4 Lock Cmd 5 Solenoid - 6 Solenoid + 7 NC 8 NC 9 NC 10 NC DC One V3 Installation Manual Page 14 of 15

DURAGLIDE FUNCTION SWITCH J6 J7 ORANGE 1 PURPLE BROWN 2 BLACK 3 BLACK PURPLE 4 YELLOW 5 6 7 8 9 10 On Stanley Duraglide replace label for function switches with the one included in kit (DC-3392). DC One V3 Installation Manual Page 15 of 15

Door Controls USA, Inc. 321 VZ County Road 4500 Ben Wheeler, TX 75754 Phone: 1-800-437-3667 Fa: 1-800-356-8858 Email: Parts@DoorControlsUSA.com DoorControlsUSA.com