LM 3188 PORT: LASER DUST MONITOR

Similar documents
DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

INSTRUCTION MANUAL YOKOHAMA QUICK CHARGER WITH LCD DISPLAY. Safety

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

User Manual of Lead Acid Smart Fast Charger (6 A) for 48V Lead Acid Battery 6Ah- 60Ah (110V Only, Standard Female Tamiya plug)

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

MPPT5012A-DUO-BT MPPT5025A-DUO-BT

INSTRUCTION MANUAL CAUTION

Where There is Miboxer There is Power. User Manual. Model No.: C2-6000

Where There is Miboxer There is Power. User Manual. Model No.: C4-12

PIXAPRO LTD. 50 Popes Lane, Oldbury, West Midlands, B69 4PA. INSTRUCTION MANUAL English. Company Registration No

mass flowmeter for compressed air

1000-Watt Energy Center

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Power Supply EL

CX-SERIES ADVANCED BATTERY CHARGER

SS1000 Power Boost Portable Power Station & Jump Starter

BOOK LIGHT MUSIC STAND LIGHT USER S MANUAL

Hydraulic Deadweight Tester Model CPB5800

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

PROVA 1011 Solar System Analyzer

SPECIALISTS IN PRESSURE, TEMPERATURE, LEVEL, FLOW, GAS DETECTION, CALIBARATION & FLUID POWER INSTRUMENTATION

INSTRUCTIONS FOR HAZ-DUST RESPIRATORY PARTICULATE AIR MONITOR MODEL HD-1100

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

Litio Solar: Solar Home System Kit LS7000-K4, 4 Lamps

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

Language specific user manuals are available on

All In one uninterruptible power supply solutions

Designed in USA, made in China by EEMB Co., Ltd. GUSTO POWER STATION USER MANUAL. LiFePO4 Battery.

MODEL 905V OPERATING INSTRUCTIONS

EGQ 212: Duct transducer, CO 2 and temperature

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

DW PADDLE-BELLOWS FLOWMETER & SWITCH

User Manual PORTABLE JUMPSTARTER

Dissolved Oxygen Measurement System with Air Blast Cleaner

No Infrared Refrigerant Leak Detector

BMS 12/200 for 12,8 Volt lithium iron phosphate batteries Especially designed for vehicles and boats

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

L-3000, L-5, L-5R. - High efficiency - Smart energy saving - IP67 protection rating - Exceptional ergonomic design - Zone 0, 1, 2 L-5R L-5 L-3000

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Volatile Organic Compounds Probe Maintenance Application Note TSI-149

Hand Held Pull Tester Instruction Manual Order No

Power Station. by Lithium USER MANUAL

DW PADDLE-BELLOWS FLOWMETER & SWITCH

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

TN299. Universal Hybrid Battery Charger IMPORTANT SAFETY WARNING. READ MANUAL in its entirely before use. INSTRUCTION MANUAL

Ventilation Control. Ventilation Control 12

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

INSTRUCTION MANUAL. Electric Drum Pump S2180, REV C EDR

Digital ph transmitter

Hi Lumens & Green Energy

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

RED CHARGER FOR RED BRICK V-LOCK LITHIUM ION BATTERIES OPERATING MANUAL

AL600ULX Series. Power Supply/Charger Installation Guide

SPECIFICATIONS LOW COST 2404R CHARGER

Wireless Accelerometer - Vibration Meter

Portable pressure calibrator, Wally Box III Model CPH7600

W here the re is MiBoxer t her e is power. C4 Smart Charger. Users Manual

Emergency lighting units EM LED Light Engines

AC/DC LIPO CHARGER INSTRUCTION MANUAL

Model DFX Doppler ultrasonic flow meter

Explosion Proof Light - Class 1 Division 2 Light - 5 hour Run Time Li-ion Battery - MADE IN THE USA

MODEL 901 OPERATING INSTRUCTIONS

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Simply a question of better measurement

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

LFP(12-16 ( CE

MX2040, DYNAMIC SIGNAL CHECKER Instruction Manual

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

Uninterruptible Power System

Lighting Accessories - EMPACK2T Kit

7007 Loop Mate 2 Loop / Voltage / Current Simulator

Current Automation Catalogue

5.2 PRE-OPERATION PROCEDURE WARRANTY

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Dawson DDM190D. Digital Multimeter User s Manual

Power Controller. (see note 1) 10 sec

LED Cordless Sitelight

SBC / 2140 / Stage Battery Charger User Manual

Digital ph transmitter

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

PIT, PIF & PIX Pressure-to-Current Transmitters

INSTRUCTION MANUAL MODEL # NOTE : This charger is designed for vehicles with dual batteries and negative ground.

HPP1 MK5 Owner s Manual

HPP1 MK5 Owner s Manual

C10325 v1.1. Thanks for your purchasing the intelligent and powerful charger.

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

HPP1 MK6-15A/20A R00 Owners Manual

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

PHARE 30/50W Ni-MH Ni-MH LIGHT 30/50W / SCHEINWERFER 30/50W Ni-MH FARO 30/50W Ni-MH

LED Canister Light System

Angle-Seat Valve System for on/off control. Type 8801/2100 electro-pneumatically operated angle-seat valve + = TWO YEAR WARRANTY on this valve system

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Transcription:

LM 3188 PORT: LASER DUST MONITOR CHOPPED LASER LIGHT SOURCE- EXCELLENT CHOICE FOR LOW DUST APPLICATIONS APPLICATIONS: Power plants Cement factories Iron and Steel factories Tunnels FEATURES: Manual Zero and Cal checks Long monitoring paths possible Minimum optics needed Less maintenance Wide operation range (1 mg/m 3... 2g/m 3 ] Internal calibration filter Analog and digital display PRINCIPLE OF OPERATION: The portable version of the LM3188 is used for temporary opacity and dust monitoring. Due to compact and lightweight size, it can be moved from one stack to another. Because of the use of laser technology, no recalibrations are required when transported from stack to stack. The measurement system is based on the single pass method. The laser beam crosses the measuring section once only and the receiver unit measures and evaluates the laser beam's weakening caused by the dust content. The optical value is converted to a mass value with the help of calibration constant. The dust monitor features two operational modes: normal and compensated. Normal operation is intended to use for higher concentrations [from 10 mg/m 3 upwards) The compensated mode is meant to be used for very low dust concentrations [< 10 mg/m 3 ), where the gradual dirt contamination of the detector surface is to be corrected. ADVANTAGES OF USING A LASER LIGHT SOURCE: No optics in the transmitter Calibration: once a year The alignment of the beam 19 ENGINEERS LANE FARMINGDALE NY 11735 USA TEL: 631.756.9116 FAX: 631.420.8052 E-MAIL: SALES@CEMTREX.COM WWW.CEMTREX.COM

Bill of Materials # Item Qty 1 2 3 4 Flange Mounted Laser Transmitter with 2x Battery Pack (in built) 1 Flange Mounted Laser Receiver with 2x Battery Pack (in built) 1 Portable Display/Controller Unit with 2x Battery Pack (in built) 1 Portable Air Compressor with 1x Battery Pack 2 NOT TO SCALE GENERAL ARRANGEMENT ONLY IF IN DOUBT, ASK. Prepared by: RM Approved by: RM Title: LM 3188-Port Arrangement Drawing Customer: Drawing No: Date: 06/2014 Rev:

MEASUREMENT FUNCTIONS AND RANGES Range switch operation D-value (D) Opacity % mass range mg/m 3 Dist. 3 feet mass range *mg/m 3 Dist. 7.5 feet mass range *mg/m 3 Dist. 15 feet 1 0...0.03 0...6.7 0...24 0...9.6 0...4.8 2 0...0.1 0...20 0...80 0...32 0...16 3 0...0.3 0...50 0...240 0...96 0...48 4 0...1.0 0...90 0...800 0...320 0...160 Option: 0...3.0 0...99 0...2400 0...960 0...480 *Depends on the size and density of the particles, values given with the size of ave. 1 µm and 1kg/dm 3 MONITOR UNIT Communication Analog Display Controls Alarms and mode indicators Outputs/Inputs Environmental TRANSMITTER Laser type Wavelength Ambient temperature Purge flow requirement Analog display for D-value, 0...100% Linear scale from the selected range, Digital display, 4-digit LCD for mg/m 3 Range selector, Alarm test button, Alarm set screw, Alarm indicator lamp, calibration screw, Mass calibration screw, Manual zero/cal-button Relay 115 or 230 VAC, 1A max, with LED indicator Current 4...20mA for real-time mg/m 3 or D-value Voltage 0...1V DC for real-time mg/m3 or D-value Current 4...20mA for opacity,optional Ambient temperature 32...158 F Power 115/230 VAC, 14 VA size: 7.1"x8.5"x5.1" weight: 3lbs Semincond./Class II 655 mn, visible light -4...+140 F 2.64gal/min size: 4.9"x3.1"x5.7" weight: 2.2lbs RECEIVER UNIT Detection Power Ambient temperature Purge flow requirement Optically matched semicond. detector, 2", 4" option From monitor unit -4...+176 F 7.93gal/min size: 6.7"x4.3"x4.9" weight: 2.8lbs 19 ENGINEERS LANE FARMINGDALE NY 11735 USA TEL: 631.756.9116 FAX: 631.420.8052 E-MAIL: SALES@CEMTREX.COM WWW.CEMTREX.COM

Air Compressor & Battery Specifications Cordless Rechargeable Air Compressor 12 or 120V, 300 Max PSI, 24 L Hose Specifications Length Inches 11.50 Width Inches 4.60 Height Inches 9.30 Weight lb 10.8 Automatic Shut-off No On-unit Display Analog Air Flow Type High Standard Input 0 10V DC Cube Inches 0.28 Max PSI 300 Certifications 2-UL Recognized Hose Length Inches 24 Power Supply 12 or 120V 12.8V 10Ah LiFePO4 Battery Pack with PCB (DGR-A) Built with 4 pieces 3.2V 10Ah LiFePO4 (Lithium Iron Phosphate) Rechargeable Battery More capacity per gram, meaning longer duration between charges. Almost no ''self discharge'', so it is always ready to go even weeks after charging. Faster charge time Specifications Voltage 12.8V Capacity 10000mah Connector No connector, bare leads 238mm x 82mm x 42mm Weight 1120g 19 ENGINEERS LANE FARMINGDALE NY 11735 USA TEL: 631.756.9116 FAX: 631.420.8052 E-MAIL: SALES@CEMTREX.COM WWW.CEMTREX.COM

Cemtrex Inc 19 Engineers Lane Farmingdale, NY 11735 USA Tel: (631) 756-9116 Fax: (631) 420-8052 www.cemtrex.com E-mail: sales@cemtrex.com Battery Charger Datasheet No. Items Specification Notes Input Characteristics Rated Input Voltage AC 100~240V 50-60Hz 1 Rated Input Current 0.4A Max. Input Power 48W Output Characteristics Max Output Voltage DC 16.8V Max Output Current 1.8A 2 Battery Capacity 14.8V Li-ion/polymer 2.2Ah Efficiency >80% Power Indication LED=Green: Trickle charging mode/no charging LED=Red: In Charging Charging Supervision and Protection Mechanism Over Voltage Protection Yes 3 CCAV Yes Output Overload Protection Yes Environment Operation Temperature -10 C~40 C 4 Operation Humidity <90% Storage Temperature -10 C~40 C Mechanical 120mm(4.7 ) x 60mm(2.4 ) x 38mm(1.5 ) Weight 8.6 oz (139g) 5 US AC Cable 1pcs Output Cable 5.5 x 2.1 x 9 mm male barrel connector Connector/Adaptor 5.5mm x 2.1mm female Barrel jack to Alligator Clips Accessory Picture

Cemtrex Inc 19 Engineers Lane Farmingdale, NY 11735 USA Tel: (631) 756-9116 Fax: (631) 420-8052 www.cemtrex.com E-mail: sales@cemtrex.com Charge Instruction 1. Make sure your AC supply source is 100-240V and your battery to be charged matches the battery requirements for the charger 2. Connect the charger to the AC outlet properly. Green LED light means power on and no battery connected. 3. Connect DC output to battery pack terminals. LED turn into red, which means the battery is in charging. 4. Green LED means the battery pack is fully charged. You can charge next battery pack or disconnect the charger. Notice 1. Make sure your battery voltage matches the charger. 2. Always place the charger in well-ventilated, dry environment. 3. Never charge other type batteries besides Li-Ion/Polymer. 4. Subject to change without prior notice, please contact us for the latest information. 5. Indoor used only, never expose the charger to water such as rain and splash. 6. Make sure good ventilation is provided when charger operation. Never place the charger near radiator, heat register or similar heat source when in charging.