onlinecomponents.com

Similar documents
ST-COMBI 4 mm 2 Pluggable Spring-Cage Terminal Blocks

STS 2,5. Extract from the online catalog. Order No.:

PIT 2,5-TG. Extract from the online catalog. Order No.:

ST 4-HESI (5X20) Extract from the online catalog. Order No.: Fuse terminal block for assembly on NS 35, for 5 x 20 cartridge fuse inserts

Circuit Breakers. DIN rail-mounted equipment protection

PT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-UI(-SP)(-NC)

PT 2,5-TWIN/1P BU. Extract from the online catalog. Order No.:

PT 2,5-QUATTRO/2P BU. Extract from the online catalog. Order No.:

PT 2,5-QUATTRO-PE. Extract from the online catalog. Order No.:

8WH2 Spring-Loaded Terminals

Fused Disconnect Terminal Blocks for Miniature Fuses with CAGE CLAMP connection, Series

8WH2 Spring-Loaded Terminals

MINI MCR-SL-UI-UI(-SP)

UK 6-FSI/C. Extract from the online catalog. Order No.:

Spring Cage Miniature Terminal Blocks FK-MPT 0,5/ -3,5

Bolt connection terminal blocks OTTA, UHV, HV. General information

PHOENIX CONTACT

QUINT-PS/24DC/24DC/10

8WH6 ipo Plug-In Terminals

QUINT-PS/24DC/24DC/20

QUINT-PS/24DC/48DC/ 5

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

SIRIUS 3RU2 Thermal Overload Relays

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

QUINT-PS/24DC/24DC/ 5/CO

UKK 5-PV. Extract from the online catalog. Order No.:

Electronic Circuit Breaker ESS20

BETA Switching Switches and Light Indicators

QUINT-PS/24DC/24DC/10/CO

IEC Low Voltage General Purpose Protection

Disconnect and component terminal blocks

Han-Power Energy Bus Components

LINOCUR Size D02 63A 230VAC/440VAC

Electronic Circuit Breaker ESS20-0..

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

DIN EN UL 508 / CSA 3RF A A 0 2

UK I. Screw connection system

Micro Contactor MA Series

PANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality

DC/DC converters - MINI-PS DC/ 5-15DC/

X-COM - and X-COM S-SYSTEM Pluggable Rail-Mounted Terminal Blocks

Marking material, tool, test plug

Selective main circuit breakers S 750 series Technical Data

General notes. Operating conditions

SUNCLIX Connection technology for photovoltaics

ZS4-SF1 Screw Clamp Terminal Block

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

Solid State Relays, 3-phase

Datasheet. W-series terminal with clamping yoke connection WSI 6

CONTACTORS POWER & ACTUATION PROVEN. reversing. non-reversing. series. series

DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals XW5T

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

Thermal-Magnetic Circuit Breaker 201/-WA

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

AF40... AF96 3-pole contactors Technical data

INNOZED D0 fuse-bases with touch protection

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

8WH6 ipo Installation Terminals

TMC 91H is now TMC 60 C Series

S1024-2POS / S POS S2024-2POS / S POS

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Viking 3 - Screw connection Disconnect terminal blocks

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Power distribution components

PHOENIX CONTACT - 01/2008

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

3NP1 Fuse Switch Disconnectors up to 630 A

POWER COMBICON Plugs and Headers PC 6/ for Currents up to 41 A, mm Pitch

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Phase + Neutral, neutral on left side

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

OUR POWER TEAM. High-Current DIN-Rail-Mount Terminal Blocks for Conductors up to 185 mm 2 (350 kcmil) vibration-proof fast maintenance-free

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Short form catalogue. Motor protection & control

NEW. Datasheet. WMF 2.5 Terminal Series

Motor Starter Reverse MSR22-FBP

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

Phase + Neutral, neutral on right side

Electronic Ballast EVG 2000-T

536 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Control Circuit Protection

Our Power Team High-Current, Rail-Mount Terminal Blocks for Conductors up to 185 mm 2 (350 kcmil)

OPERATING INSTRUCTIONS

Distribution terminal block; 3 x CAGE CLAMP connection 10 mm²; 1 x screw-clamp connection 35 mm²

H3DS-X - Solid State Two-Wire Timer

SAC-4P-M12MS/ 5,0-PUR SH

Series KTU7 UL489 Molded Case Circuit Breakers

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

USA Canada On the Internet: Toll Free wieland Product Range Electrical Connections

Installation and Operating Instructions

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

l Snap-Action Switches

Figure 1: Device components

Transcription:

s ST Spring cage fuse terminal blocks from Phoenix Contact satisfy two important tasks of electrical connection systems. Firstly, they act as carriers for fuses and secondly, they assume the task of potential distribution. The universal ST bridge shaft makes continuous bridging possible between ST feed-through terminal blocks and ST fuse terminal blocks. ST 4-HESI can be used for the 5 x 20 mm fuse format, which is a standard in electrical engineering. It is also available with a light indicator for signaling a triggered fuse. ST 4-HESI (6,3 x 32) is characterized by the double bridge shaft located in the same position as in the entire ST series. This opens up all options for power distribution. To make it practical to use, test connections are provided on both sides of the standardized (6.3 x 32 mm) fuse inserts. Terminal blocks with a light indicator are available to signal the triggering of a fuse. The large-surface labeling option on the enables fast identification of the fused circuits. Flat-type fuses in accordance with ISO/DIS 8820/ DIN 72581-3 or alternatively the TCP thermal miniature circuit breaker can be used as the fuse element in the ST 4-FSI/C fuse terminal block. Terminal blocks with a light indicator are available for quick error diagnosis "at a glance". A wide range of potential distribution options can be implemented using the ST bridge shaft which is integrated in this terminal block. Attention: The cartridge fuse holders should be selected according to the maximum power dissipation (self-heating) of the cartridge fuse inserts. The thermal conditions in closed fuse holders should be checked according to the application and installation. Higher ambient temperatures are an additional strain on fuse inserts. In applications of this kind, the shift of the rated current should be taken into consideration accordingly. Phoenix Contact GmbH & Co. KG 32823 Blomberg, Germany Phone +49 52 35 3-00 Fax +49 52 35 3-4 12 00 www.phoenixcontact.com Local Contact: www.phoenixcontact.com/salesnetwork

ST 4-HESI (5 x 20) DIN VDE 0611 with fuse 0.08-6 0.08-4 28-10 1) 1) as disconnect term.bl.0.08-6 0.08-4 28-10 6.3 250 1 ) see table below (the current is determined by the fuse used) Fuse terminal block, for mounting on 3, for cartridge fuse inserts 5 x 20 mm terminal width 6.2 ST 4-HESI (5 x 20) 30 36 36 9 50 20-pos. FBS 2-6 I max. : 32 A 30 30 33 6 50 FBS 3-6 32 A 30 30 24 2 50 FBS 4-6 32 A 30 30 25 5 50 FBS 5-6 32 A 30 30 34 9 50 FBS 10-6 32 A 30 30 27 1 10 FBS 20-6 32 A 30 30 36 5 10 ATP-ST 4 30 30 72 1 50 (3) Screwdriver, for (4) Zack strip, flat, for labeling the center and outer marker grooves white ZBF 6:UNPRINTED 08 08 71 0 10 (5) Zack strip, 10-section, for ZB 5:UNPRINTED 10 50 00 4 10 Width / length [mm] 6.2 / 61.5 Height (NS 35/7,5 / NS 35/15) [mm] 62.5 / 70 Fuse type ISO/DIS 8820/DIN 72 581-3 / dimensions / [mm] G / 5 x 20 at 23 C based on [W] 1) Rated surge voltage / contamination class [kv] / 4 / 3 at 23 C (based on E DIN VDE 0611-6:2001-04) Terminal block type U Overload protection Short-circuit protection only [V] Single Interconnected Single Interconnected ST 4-HESI (5 x 20) 250 2.5 W 1.6 W 4.0 W 2.5 W Phoenix Contact page 2 of 7

s with Light Indicator ST 4-HESILED and ST 4-HESILA (5 x 20) DIN VDE 0611 with fuse 0.08-6 0.08-4 28-10 1 ) 1 ) as disconnect term.bl.0.08-6 0.08-4 28-10 6.3 250 1 ) see table below (the current is determined by the fuse used, the voltage by the light indicator selected) 2 ) If the fuse is defective, the downstream circuit is not off load. Fuse terminal block 2 ), for mounting on 3, for cartridge fuse inserts 5 x 20 mm, with light indicator for: 15-30 V AC/DC, 3.5-8.1 ma terminal width 6.2 30-60 V AC/DC, 0.8-2.0 ma terminal width 6.2 110-250 V AC/DC, 0.5-1.0 ma terminal width 6.2 20-pos. ST 4-HESILED 24 30 36 54 7 50 ST 4-HESILED 60 30 36 55 0 50 ST 4-HESILA 250 30 36 56 3 50 FBS 2-6 I max. : 32 A 30 30 33 6 50 FBS 3-6 32 A 30 30 24 2 50 FBS 4-6 32 A 30 30 25 5 50 FBS 5-6 32 A 30 30 34 9 50 FBS 10-6 32 A 30 30 27 1 10 FBS 20-6 32 A 30 30 36 5 10 ATP-ST 4 30 30 72 1 50 (3) Screwdriver, for (4) Zack strip, flat, for labeling the center and outer marker grooves white ZBF 6:UNPRINTED 08 08 71 0 10 (5) Zack strip, 10-section, for ZB 5:UNPRINTED 10 50 00 4 10 Width / length [mm] 6.2 / 61.5 Height (NS 35/7,5 / NS 35/15) [mm] 62.5 / 70 Fuse type ISO/DIS 8820/DIN 72 581-3 / dimensions / [mm] G / 5 x 20 at 23 C based on [W] 1) Rated surge voltage / contamination class [kv] / 4 / 3 at 23 C (based on E DIN VDE 0611-6:2001-04) Terminal block type U Overload protection Short-circuit protection only [V] Single Interconnected Single Interconnected ST 4-HESI... 250 2.5 W 1.6 W 4.0 W 2.5 W Phoenix Contact page 3 of 7

ST 4-HESI (6,3 x 32) IEC 60 947-7-3 0.08-6 0.08-4 28-10 10* 400* * Current and voltage are determined by the fuse used. Fuse terminal block, for mounting on 3, for cartridge fuse inserts 6.3 x 32 mm, black terminal width 8.2 ST 4-HESI (6,3 x 32) 30 36 38 5 50 FBS 2-8 I max. : 32 A 30 30 28 4 10 FBS 3-8 32 A 30 30 29 7 10 FBS 4-8 32 A 30 30 30 7 10 FBS 5-8 32 A 30 30 31 0 10 FBS 10-8 32 A 30 30 32 3 10 ATP-QTC TWIN 32 06 21 2 50 (3) Adapter bridge, for connecting an ST 4-HESI (6,3 x 32) to an ST 4, ST 2,5 or QTC 1,5 RB ST 6-(2,5/4) 30 30 86 0 50 (4) Screwdriver, for (5) Zack strip, flat, for labeling the (6) Zack strip, 10-section, for ZB 6:UNPRINTED 10 51 00 3 10 Width / length [mm] 8.2 / 76.5 Height (NS 35/7,5 / NS 35/15) [mm] 69 / 76.5 Fuse type ISO/DIS 8820/DIN 72 581-3 / dimensions / [mm] G / 6 x 32 Maximum current with single arrangement [A] 10 at 23 C based on [W] see table Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG applied for 600 / 10 / 24-10 CSA/CUL: [V] / [A] / AWG applied for 600 / 10 / 24-10 at 23 C (based on E DIN VDE 0611-6:2001-04) Terminal block type U Overload protection Short-circuit protection only I max. [V] Single Interconnected Single Interconnected [A] ST 4-HESI (6,3 x 32) 400 1.6 W 1.6 W 4.0 W 2.5 W 10 Phoenix Contact page 4 of 7

ST 4-HESILED and ST 4-HESILA (6,3 x 32) IEC 60 947-7-3 0.08-6 0.08-4 28-10 10* 400* * Current and voltage are determined by the fuse used. 1 ) If the fuse is defective, the downstream circuit is not off load. Fuse terminal block 1 ), for mounting on 3, for cartridge fuse inserts 6 x 32 mm, with light indicator for: 15-30 V AC/DC, 1-2.5 ma terminal width 8.2 110-250 V AC/DC, 0.5-2.5 ma terminal width 8.2 ST 4-HESILED 24 (6,3 x 32) 30 38 76 5 50 ST 4-HESILA 250 (6,3 x 32) 30 38 77 8 50 FBS 2-8 I max. : 32 A 30 30 28 4 10 FBS 3-8 32 A 30 30 29 7 10 FBS 4-8 32 A 30 30 30 7 10 FBS 5-8 32 A 30 30 31 0 10 FBS 10-8 32 A 30 30 32 3 10 ATP-QTC TWIN 32 06 21 2 50 (3) Adapter bridge, for connecting an ST 4-HESI (6,3 x 32) to an ST 4, ST 2,5 or QTC 1,5 RB ST 6-(2,5/4) 30 30 86 0 50 (4) Screwdriver, for (5) Zack strip, flat, for labeling the (6) Zack strip, 10-section, for ZB 6:UNPRINTED 10 51 00 3 10 Width / length [mm] 8.2 / 76.5 Height (NS 35/7,5 / NS 35/15) [mm] 69 / 76.5 Fuse type ISO/DIS 8820/DIN 72 581-3 / dimensions / [mm] G / 6 x 32 Maximum current with single arrangement [A] 10 at 23 C based on [W] see table Nominal voltage / current / conductor sizes UL: [V] / [A] / AWG applied for 600 / 10 / 24-10 CSA/CUL: [V] / [A] / AWG applied for 600 / 10 / 24-10 at 23 C (based on E DIN VDE 0611-6:2001-04) Terminal block type U Overload protection Short-circuit protection only I max. [V] Single Interconnected Single Interconnected [A] ST 4-HESI (6,3 x 32) 400 1.6 W 1.6 W 4.0 W 2.5 W 10 Phoenix Contact page 5 of 7

ST 4-FSI/C Connection data 0.08-6 0.08-4 28-10 30 400 Fuse terminal block, for mounting on 3, terminal width 8.2 ST 4-FSI/C 30 36 37 2 50 (1) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.25-0,5 mm 2 gray 0.75-1 mm 2 black (2) Plug-in bridge, for 2-pos. (3) Test adapter, for 4 mm test plug PS and 4 mm safety test plugs, making contact in the bridge shaft ISH 4/0,5 30 02 88 5 50 ISH 4/1 30 02 89 8 50 FBS 2-8 I max. : 41 A 30 30 28 4 10 FBS 3-8 41 A 30 30 29 7 10 FBS 4-8 41 A 30 30 30 7 10 FBS 5-8 41 A 30 30 31 0 10 FBS 10-8 41 A 30 30 32 3 10 I 4 30 30 92 5 10 (4) 2.3 mm test plug 1 ), consisting of metal part and red insulating sleeve MPS-RD 02 01 55 3 10 (5) Screwdriver, for (6) Zack strip, flat, for labeling the (7) Zack strip, 10-section, for labeling in the white ZB 8:UNPRINTED 10 52 00 2 10 Width / length [mm] 8.2 / 86.5 Height (NS 35/7,5 / NS 35/15) [mm] 43.5 / 51 Fuse type ISO/DIS 8820/DIN 72 581-3 C Maximum current with single arrangement [A] 30 at 23 C based on [W] 1) 1) On request. Phoenix Contact page 6 of 7

s with Light Indicator ST 4-FSI/C-LED Connection data 0.08-6 0.08-4 28-10 30 400 Fuse terminal block 1 ), for mounting on 3, with light indicator for: 12 V DC, 2.0 ma terminal width 8.2 24 V DC, 2.0 ma terminal width 8.2 (1) Insulating stop sleeve, prevents unintentional clamping of the insulation in the case of smaller cross sections Cross section range: 0.25-0.5 mm 2 gray 0.75-1 mm 2 black (2) Plug-in bridge, for 2-pos. cross-connections in the (3) Test adapter, for 4 mm test plug PS and 4 mm safety test plugs, making contact in the bridge shaft ST 4-FSI/C-LED 12 30 36 49 5 50 ST 4-FSI/C-LED 24 30 36 50 5 50 ISH 4/0,5 30 02 88 5 50 ISH 4/1 30 02 89 8 50 FBS 2-8 I max. : 41 A 30 30 28 4 10 FBS 3-8 41 A 30 30 29 7 10 FBS 4-8 41 A 30 30 30 7 10 FBS 5-8 41 A 30 30 31 0 10 FBS 10-8 41 A 30 30 32 3 10 I 4 30 30 92 5 10 (4) 2.3 mm test plug 1 ), consisting of metal part and red insulating sleeve MPS-RD 02 01 55 3 10 (5) Screwdriver, for (6) Zack strip, flat, for labeling the (7) Zack strip, 10-section, for labeling in the white ZB 8:UNPRINTED 10 52 00 2 10 Width / length [mm] 8.2 / 86.5 Height (NS 35/7.5 / NS 35/15) [mm] 43.5 / 51 Fuse type ISO/DIS 8820/DIN 72 581-3 C Maximum current with single arrangement [A] 30 at 23 C based on [W] 2) 1) If the fuse is defective, the downstream circuit is not off load. 2) On request. TNR 5125896/15.03.03-01 Phoenix Contact 2003 Phoenix Contact page 7 of 7