ph-kompaktelektrodensystem sensopac CPA 320

Similar documents
Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Orbisint CPS11 and CPS11D

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Electromagnetic Flow Monitor magphant

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Level Limit Switch liquiphant FTL 360 / FTL 361

Orbisint CPS12/CPS12D/CPS13

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Technical Information Cleanfit CPA472D

Conductivity Measuring Cells ConduMax W CLS 19

Ceraliquid CPS42/CPS42D/CPS43

Orbipore CPS91 and CPS91D

Technical Information

Ceraliquid CPS41 and CPS41D

Level Limit Switch liquiphant FTL 365 / FTL 366

Digital ph transmitter

Orbisint CPS11 and CPS11D

Technical Information Cleanfit CPA871

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Technical Information Ceraliquid CPS41D and CPS41

INSERTION Adaptor for analysis

Digital ph transmitter

General Specifications

Pressure transducer DMU 01K Compact version

Flow-Through Fitting ARF 215

Conductivity Measuring Sensor InduMax H CLS 52

Conductivity Sensors ConduMax W CLS 19

Technical Information Cleanfit CPA875

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

Thermowell for temperature sensors omnigrad M TW 13

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Automatic sensor lock-gate for extreme applications with ceramic sealing to the proces

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP200 Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

Operating Instructions Dipfit CPA111

SITRANS P measuring instruments for pressure

Hydrostatic. Overview 192 VEGABAR series VEGAWELL Accessory 200. Hydrostatic VEGABAR series 60 and VEGAWELL

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

Conductivity Measurement CLM 280

Diaphragm Valve, Metal

Hydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194.

Inline version with application-specific process adaptation

Rugged ph/redox (ORP) Sensor Systems with Rapid Temperature Response for Critical Processes

JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Praher S4 Ball Valve. manual valves. Materials. Sizes. Pressure Rating. Features. Connections. Valve Dimensions. Actuation.

Thermowell for temperature sensors omnigrad M TW 11

Unifit CPA442. Technical Information. Process assembly For installation of 120 mm sensors in food and beverage, biotechnology and chemical industries

Level Limit Switch soliphant FTM 930/931/932/ Z

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

N086, N186, N786. Pressure retaining valve, Plastic

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Diaphragm Valve, Plastic 2/2 way, motorized

Plastic tube variable area flowmeter for liquids and gases

GEMÜ 549 esydrive Motorized globe valve

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

SensoGate WA 131 M. User Manual. Sensor Lock-Gate

Technical Information Cleanfit CPA451

Process pressure. Overview 168 VEGABAR series VEGABAR series Accessory 184. Process pressure VEGABAR

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Diaphragm valve, Plastic

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

SE 655 N-GEFFT0AM Digital Toroidal Conductivity Sensor

Electromagnetic Flow Monitor magphant

PORTAELETTRODI HAMILTON

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

RTD Temperature Sensor omnigrad T -TR 470

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Diaphragm seal with threaded connection Plastic version Model

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

R677. Diaphragm Valve, Plastic

General Specifications

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

EISELE LIQUIDLINE PROGRAM CONNECTIONS FOR COOLING WATER

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

Dissolved Oxygen, ph, and Conductivity

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

GEMÜ 539 esydrive Motorized globe valve

Level Probe multicap DC 16

Diaphragm Valve, Plastic

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

C 200 Modern Construction. Flexible Modular Design. Highest Safety.

Inductive conductivity meter

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

CORROSION & CHEMICAL RESISTANT VALVES AND ACTUATORS

Diaphragm Valve, Metal

Worcester 18/19 Series. Modular Multi-Way Ball Valves

Technical Data. Flow Meter Schwertberg, Poneggenstr. 5 Austria/Europe Fax +43/7262/ Tel.

Technical Information Cleanfit Control CYC25

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Transcription:

Technische Information TI 0C/0/de ph-kompaktelektrodensystem sensopac CPA 0 One of the two reference systems is specially protected so that only the second monitoring reference system is affected by penetration of electrode poisons. Any resulting difference in measured values is signaled by the Mycom CPM instrument before the main measuring circuit is influenced. Areas of application In-process applications for in-line measurement at pressures of up to 0 bar without counterpressure. For measurement in aggressive media (PP and PVDF options). For measurement in the food industry (stainless steel version). Sensopac ph/redox electrode systems are suitable for process measurement at high pressures and temperatures. For measurements in hazardous areas (zone 0), the Sensopac can be equipped with Ex electrodes. Self-monitoring is possible with all Sensopac types. A double reference electrode is immersed in the internal bridge electrolyte which is in contact with the medium via a large-area, dirt repelling diaphragm. The two reference systems of this electrode are connected to two measuring circuits of the ph/redox measuring instrument Mycom CPM. Benefits at a glance Problem-free, direct application under high pressures (max. 0 bar) and temperatures (0 C/0 C) permits close matching to process conditions. High measuring accuracy in conjunction with the ph measuring transmitter such as Mycom CPM : Self-monitoring of reference system with fault signaling; an alarm isissued before the main measuring circuit is affected. The reference system is protected by an electrolyte bridge. Bridge electrolyte adaptable to the medium and easily replaceable. No additional protective assemblies required. Can be directly used as an immersion or flow sensor. Numerous mounting accessories from welding sockets to immersion assemblies. Quality made by Endress+Hauser ISO 00 Endress +Hauser Nothing beats know-how

Assembly 0 Assembly from Sensopac CPA 0: Type UBS built-in apter for installing the Sensopac in threaded fitting G " ph measuring electrode Pt 00 temperature sensor Shock protection Diaphragm cartridge Union nut (part of UBS adapter) Sensopac body Removable protective hood Electrode connector 0 Cable, ready-made with connectors Cap with sealed measuring cable entry Standard material combinations: Polypropylene body, Hastelloy-C shock protection, EPDM O-rings Stainless steel body, stainless steel shock protection, EPDM O-rings PVDF body, Hastelloy-C shock protection, EPDM O-rings A wide range of measuring electrodes permits close system matching. For example, the electrode type CPS - BA GSA permits ph measurements up to ph and temperatures up to 0 C. Permits measurements in hazardous area zone 0 when equipped with Conducta Ex electrodes. All electrodes built into the Sensopac system are equipped with a screw head and are easily replaced when maintenance is required. The Sensopac compact ph electrode system can be installed and removed quickly and easily. To assist this, the system is supplied with one of the following options of built-in adapters: UBS a threaded adapter for quick installation and removal. AMS a dairy adapter, preferably used where cleaning or sterilization is required. Furthermore, a wide range of accessories, such as immersion sensors, flow sensors and a spray head for electrode cleaning, is available.

Sensopac system overview The Sensopac CPA 0 can be installed in various built-in adapters. The type of built-in adapter is specified with the order. Connection: - Cable with connectors and connector sleeves, ready-made, lengths, 0, m Base body: - PP - PVDF - stainless steel. Electrodes: - ph electrode - double reference CPS -0 TD GSA - temperature CTS -A GSA Standard built-in adapter AMS adapter for installation in dairy fittings UBS adapter for installation in G " sockets UBS + GS (G " sockets) Automatic cleaning ➀ Automatic cleaning during measuring operation with a spray cleaning system is possible. The type CPR spray head can also be retrofitted when using the AMS, UBS, GS adapters. The spray head is suitable for water and for diluted cleaning chemicals. ➁ ➀ Sensopac with built-in spray head for electrode cleaning ➁ CPA 0 with Sensopac and built-in cleaning system

Assemblies for Sensopac CPA 0 ➀ ➁ ➀ For open tanks: immersion assembly CPA 0-S ➁ For closed tanks: process assembly CPA 0-S ➂ ➃ For installation in pipes: ➂ Flow assembly CPA 0-S material: PP; PVDF ➃ Flow assembly CPA 0-S material: stainless steel

Operating principle Sensopac with connection to Mycom CPM : ph electrode immersed directly in the measured solution Low-impedance double reference electrode immersed in bridge electrolyte Reference system for the master measuring circuit Reference system for the monitor circuit Bridge electrolyte in the large reference chamber Diaphragm cartridge with a dirt-repellent, blocking-free PVF diaphragm Master measuring circuit Monitor circuit The ph electrode () generates a half-cell voltage dependent on the ph of the medium. The dirt-repellent PVF diaphragm in the diaphragm cartridge prevents blocking and assures electrical contact between the medium and the bridge electrolyte () in which the double reference electrode () is immersed. Reference system () of the double reference electrode supplies the constant reference voltage for the master measuring circuit. Reference system () of the double reference electrode supplies the reference voltage for the monitor circuit. Self-checking Both reference systems () and () are located in the bridge electrolyte () behind the diaphragm cartridge (). Both possess an additional diaphragm system. Reference system () is arranged in a long capsule behind another diaphragm at the upper opening of the capsule. Such an arrangement ensures that if any interfering ions penetrate into the bridge electrolyte (), only reference system () is contaminated, while reference system () is seldom affected. Any difference in the two reference potentials is detected by the ph instrument Mycom CPM and results in an error message. The most important feature of this monitoring technique is that the alarm is produced before there is any drift on the master measuring circuit itself.

Installation and dimensions Picture left: Construction of Sensopac Measuring cable Star knob for tightening and releasing the pressure seal Measuring cable entry PE connector Protective cover Potential matching connector (PMC) Electrode connector Union nut O-ring 0 Sensopac body Protective cap/ calibration cup Shock protection bolt Electrodes Diaphragm cartridge Picture right: Sensopac with UBS adapter Sensopac Snap rings Union nut UBS adapter 0 0 Ø 0 G " Required mounting clearance 00 mm Sensopac with AMS adapter (food applications) Sensopac AMS adapter DN 0 threaded socket, to DIN Short T-piece DN 0, DIN

Installation and dimensions Picture left: Sensopac AFS-V adapter. Stainless steel. version for flange mounting NW 0 flange, ND, to DIN Material: PP Weld-on flange NW 0, ND, to DIN AFS Picture right: Threaded socket weld-on GS, GS-V for Sensopac installation Required mounting clearance 00 mm Ø 0 Ø0 0 0 0 G " 0 Required mounting clearance 00 mm Sensopac Snap rings Union nut NW 0, to DIN Material:.0 Width across flats SW UBS Threaded socket GS, GS-V out of PP or. Picture left: Immersion assembly CPA 0-S for installation of Sensopac Weather protection cover SR Pg cable gland Assembly head Oval flange Mounting plate Immersion tube Threaded connection for mounting Sensopac Sensopac body mounting holes, Ø 0 Pg 0 0 Picture right: Immersion assembly CPA 0-S for installation of Sensopac Weather protection cover SR Pg cable gland Assembly head Threaded fitting Flange Immersion tube Threaded connection for mounting Sensopac Sensopac body mounting holes, Ø 0 Pg 0 0 0 0 0 0

Installation and dimensions Required mounting clearance 00 mm Flow assembly CPA 0-S for installation of Sensopac, Material PP, PVDF Sensopac electrode system Union nut NW 0, to DIN Material:.0 Pipe clamp with central installation hole Pipe DA DN Screwed nipple NP, G" Material: PP, PVDF O-ring Material: EPDM Pipe DA DN Plug G" Material: PP, PVDF Flow assembly CPA 0-S out of PP or PVDF Zufluß 0 Flow assembly CPA 0-S for installation of Sensopac out of. Adapter for Sensopac, included as standard O-ring, EPDM Union nut Weld-on flange DN, PN, connection to DIN 0 Drain plug G 0

Electrical connections yl/gn gn bn wt rd blk wt 0 Cable configuration for Sensopac with double reference system Cable: CPK Reference signal measuring circuit Reference signal measuring circuit ph signal Pt 00 -wire connection Potential matching PE Potential matching pin Pt 00 ph electrode Double reference electrode 0 Coaxial line not visible Cover screen connection Reference system Reference system br yl/gn gn bn wt rd blk wt Cable configuration for Sensopac with two ph measuring electrodes Cable: CPK Reference signal measuring circuit Reference signal measuring circuit ph signal measuring circuit ph signal measuring circuit Potential matching PE Combination measuring cable CPK Potential matching pin ph electrode 0 ph electrode Double reference electrode Cover screen connection Reference system Reference system 0

Technical data Base body............................ polypropylene PP............................ polyvinylidene fluoride PVDF................................ stainless steel. Seals............................ EPDM (standard), Viton Potential matching pin.................. Hastelloy C (standard)............................... or stainless steel. Electrodes.................. glass, special types made of plastic................................. CPS - BA GSA Double reference electrode.................. CPS -0 TD GSA Temperature sensor......................... CTS -A GSA Internal thread for electrodes....................... Pg. Diaphragm cartridge................. replaceable PVF diaphragm,....................... screwed into PVDF cartridge DKV-HT Electrode seals.......................... EPDM (standard) Bridge electrolyte................................ KCl Socket wrench for electrodes and diaphragm........... size /special Subject to modifications. Pressure [bar] 0 PVDF stainless steel. PP Pressure and temperature operating range 0 0 0 0 0 00 0 Temp. [ C] Maximum permissable operating pressure Working pressure for different materials and temperatures Temperature [ C] PP [bar] PVDF [bar]. [bar] - 0 0 0 0 0 0 0 0, 0 0 0, 0 0 0 0 0 0 0 0 0

Order code and Accessories CPA0 Version S for use with Sensopac electrode system CPA 0 Material / Immersion depth 0 PP / 000 mm PP / 00... 000 mm 0 PVDF / 000 mm PVDF / 00... 000 mm Special version non- standard appliance CPA0- Order code CPA0 Version S for use with Sensopac electrode system CPA 0 T for use with Sensopac electrode system CPA 0, flanse DN for Chemoclean Materials / Immersion depth 0 PP / 000 mm PP / 00-000 mm Special version non- standard appliance CPA0- Order code CPA0 Version S for use with Sensopac compact system CPA 0 Materials / Process connection 00 PP / G " BSP. / flanse x DN 0 PVDF / G" BSP Special version CPA0- Order code

Order code Sensopac CPA 0 Assembly materials / O-rings P PP / EPDM F PVDF / EPDM V Stainless steel. / EPDM Y Special version Number of electrodes For use with meas. and ref. electrode Special version Electrode type CPS -AA GSA CPS -BA GSA Special version Cable length / colour 0 Metre, black 0 Metre, black Metre, black Metre, blue (Ex) 0 Metre, blue (Ex) Metre, blue (Ex) Special version Adaptor type E Adaptor for CPA 0 / CPA 0 K Without adaptor U UBS out ofpp V UBS out of stainless steel W UBS out of PVDF Y Special version Application A Standard type electrode Z EX-type electrode Y Special version CPA0- Order code Endress+Hauser GmbH+Co. - Instruments International - P.O. Box D- Weil am Rhein Tel. (0 ) - 0 Fax (0 ) Endress Hauser Nothing beats know-how TI 0C/0/en/0. Printed in Germany / DT (00)