INSPECTION GUIDELINES: GAS METER RELEASE

Similar documents
INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

EV Charging Station Submittal Requirements

ELIGIBILITY CHECKLIST FOR EXPEDITED SOLAR POOL HEATING PERMITTING

City of Palo Alto (ID # 8028) City Council Staff Report

Electric Vehicle Charging Station Article California Electrical code (CEC) General Requirements:

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

For Conduit Inspections

7. Protection System Testing

Electric Vehicle Charging Station Article California Electrical code (CEC) General Requirements:

Permitting, Installation and Inspection Residential EV Chargers Be aware that there are different types of Electric Vehicle (EV) Chargers.

City of Perris Development Services Building & Safety

Solar PV Standard Electrical Plan

COUNTY OF RIVERSIDE BUILDING AND SAFETY DEPARTMENT

California Department of Housing and Community Development (HCD) 2016 CALGreen

Solar PV Standard Electric Plan

Natural Gas Reference Guide

TABLE II Electrical Permit Fees

Expedited Permitting Process for Electric Vehicle Charging Stations

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

JACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

GUIDE FOR MICROGENERATION INTERCONNECTION TO CITY OF MEDICINE HAT ELECTRIC DISTRIBUTION SYSTEM

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

E Series CE Approved Intermittent Pilot Ignition Control

BGE Service Application Guidelines Residential Single Projects

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Energized Electrical Work

Rheem Classic Series Upflow/Horizontal Gas Furnace

PERMANENT RESIDENTIAL UNDERGROUND SERVICE

Rheem Classic Series Upflow/Horizontal Gas Furnace

All territory within the incorporated limits of the City and land owned or leased by the City.

First Correlating Revision No. 1-NFPA [ Section No ]

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008

ELECTRONIC FIREPLACE DAMPER

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications

Temporary Sales Trailer Application

Electric underground service installation requirements

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

Electric Vehicle Charging System Guidelines for Residential Buildings

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.

UPFLOW/ HORIZONTAL GAS FURNACE

Lassen MUD PV BUYDOWN PROGRAM Photovoltaic Systems Guidelines

Hamilton 3VO Submittal

SUMMARY OF PROPOSED CHANGES,

Indianapolis Power & Light Company

Publication No.: PSG

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

10 Commercial, Industrial, Agricultural Services

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Actuated Valves PRICING

National Board Update

XIII. Repair Parts 106

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

Eligible Renewable Generation (ERG) Application INSTRUCTIONS

Non-Residential Solar Energy Photovoltaic (PV) Packet

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

STREAMLINED SOLAR CHECKLIST Owner Name:

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Utilities (electric & natural gas) allocate resources to promote energy efficiency

Model VSI-I & VSI-II Positive Pressure Venting Systems

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

ELITE SERIES R-410A Ready - Multi-Position

TEMPORARY SERVICE TABLE OF CONTENTS PUD SERVICE TERRITORY AND CONTACTS CHAPTER ONE - INTRODUCTION CHAPTER TWO - TEMPORARY OVERHEAD SERVICE

RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS SECTION II RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS

OSHA Update. Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926)

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

RULE EMISSIONS OF OXIDES OF NITROGEN FROM SMALL INDUSTRIAL, INSTITUTIONAL, AND COMMERCIAL BOILERS, STEAM GENERATORS, AND PROCESS HEATERS

Q35 Series Automatic Vent Damper System

CHAPTER 16 GARBAGE ARTICLE I - GENERAL REGULATIONS DEFINITIONS. As used in this Code, the following definitions shall apply:

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

Yukon Oil Inspection Survey Results and Recommendations

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

WORK/REST RULES FOR RAILWAY OPERATING EMPLOYEES

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

Installation, Operation and Maintenance Manual

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Trade Price Book - 816

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

BUSWAY Low Voltage (Pow-R-Flex)

Gas Conversion Kits and Instructions

Date: Project #: Engineer: Prepared By: Bid Date:

2017 Solid Waste Rates & Fees

Applies to: Models F, B, FE, and BE with spark pilot

Installation, Operation and Maintenance Manual

Associated equipment As related to metering equipment: such as the current transformers, CT wiring and test switches.

33'-10"± ROOF #1 (2) SUNPOWER SPR E C-AC MICROINVERTER MODULES ROOF #2 (13) SUNPOWER SPR E C-AC MICROINVERTER MODULES 78'-9"± 25'-5"

$ homes in a subdivision. The Fee includes an S-1 Pedestal. $ homes in a subdivision. The Fee includes an S-2 Pedestal.

Residential and Non-Residential Checklist for Permitting Electric Vehicles and Electric Vehicle Service Equipment (EVSE)

TEMPORARY ELECTRICAL SERVICE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

Service Requirements

Transcription:

Gas Meter Release Page 1 of 3 Revision Date: 6/12/2018 DEVELOPMENT SERVICES BUILDING INSPECTION INSPECTION GUIDELINES: GAS METER RELEASE INSPECTION CODE: 222 SCOPE: RESIDENTIAL AND COMMERCIAL APPLICABLE CODES: 2016 CBC, CRC, CPC, CMC, CEC, CALGreen, CEnC, and PAMC The information provided in this document is general and intended as a guide only. Each project is unique and additional requirements may be enforced as deemed appropriate. IMPORTANT Failure to complete items below, prior to inspection, may result in a re-inspection fee. Gas piping is not allowed under slab/structure unless properly vented. See the Under Slab/Structure Gas Piping checklist for more information. Gas piping shall not be used as a grounding conductor or electrode. (CPC 1211.3) EARTHQUAKE-ACTUATED GAS SHUTOFF VALVE IS NOT REQUIRED Voluntary installation requires a permit and CPA inspection. (CPC 1211.7) The valve shall be installed on the houseline side of the meter and be listed by recognized testing agency. (CPC 1211.7) A whole house gas pipe pressure test is required at 10 psi for15 minutes. Note: Owner is responsible for resetting the valve when valve is activated/shut off by seismic or other event. (CPC 1213.3) PRE-INSPECTION Prior to inspection, verify that all required sequential inspections and correction notices are complete. Gas meters exposed to vehicular traffic shall be protected by bollards. (CPC 1208.6.1.1) See approved bollard installation detail by WGW. Residential projects wanting a gas meter release prior to Final Inspection must follow the process under the Residential Conditional Meter Release form. If you have a copy of the Inspection Guidelines, see the Index under 22.0 FORMS AND NOTICES for the form, or find it online at: https://cityofpaloalto.org/civicax/filebank/documents/18656. Utilities require an inspection where they apply a green sticker at the gas stub out; contact WGW at (650) 496-5940.

Gas Meter Release Page 2 of 3 Revision Date: 6/12/2018 INSPECTION See WGW s Standard Details, Appendix C, for gas meter clearances: https://www.cityofpaloalto.org/civicax/filebank/documents/34287. Verify that gas pressure/water column is suitable for gas appliances. (CPC 1213.2) Pressure tests of 10 psi or less shall be performed with gauges of 0.10 psi incrementation or less. (CPC 318.2) Pressure testes exceeding 10 psi but less than 100 psi shall be performed with gauges of 1 psi incrementation or less. (CPC 318.3) Test gauges shall have a pressure range not greater than twice the test pressure applied. (CPC 318.5) The test pressure shall than 10 psi for not less than 15 minutes with no perceptible drop in pressure. (CPC 1213.3) See the Whole House Gas Test checklist for more information. For appliances: o Furnace, water heater and boilers shall be installed and ready for operation per manufacturer s requirements. o Provide/install all flues and combustion air ducts. o Secure appliances for seismic movement. Provide 3 working clearance in front of meter. (WGW Standard Details) Metal underground yard pipe requires dielectric union (minimum 6 above grade). When there is no riser, indicate on release tag NO RISER (this usually is an indicator that fees have not been paid and delays will occur in meter set), contact WGW s Todd Carlson at (650) 496-6960.

Gas Meter Release Page 3 of 3 Revision Date: 6/12/2018 WGW STD. GD-02A: 250-800 CHF Residential Diaphragm Gas Meter Clearances (see latest detail on WGW s Standard Details, Appendix C: https://www.cityofpaloalto.org/civicax/filebank/documents/34287) WGW STD. GD-02B: 1000-1500 CHF Gas Meter Clearances (see latest detail on WGW s Standard Details, Appendix C: https://www.cityofpaloalto.org/civicax/filebank/documents/34287)