TEMPORARY SERVICE TABLE OF CONTENTS PUD SERVICE TERRITORY AND CONTACTS CHAPTER ONE - INTRODUCTION CHAPTER TWO - TEMPORARY OVERHEAD SERVICE

Similar documents
Associated equipment As related to metering equipment: such as the current transformers, CT wiring and test switches.

Installing or Rebuilding Your Electric Service

Residential Application for New Electric Service

TEMPORARY ELECTRICAL SERVICE

Clark Public Utilities Commercial Electric Service Handbook. This page left blank intentionally.

Electric Service Conversion Overhead-to-Underground Xcel Energy Electric Connections. Minnesota North Dakota South Dakota

Commercial Electric Service Handbook

Application for Service Residential Subdivision / Development

RESIDENTIAL NEW CONSTRUCTION PACKET CITY OF VERO BEACH UTILITIES. Important Notice to Builders/Contractors/Developers From Electrical Engineering

RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS SECTION II RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS

Please Refer to Attached Sample Form

Approved Contractor Construction e-guide Residential Commercial

BGE Service Application Guidelines Residential Single Projects

Customer Guide to Electric Service Requirements

Table of Contents. Electrical Service Requirements. 1. General Requirements

Please Refer to Attached Sample Form

New Commercial Service Request-Job Process

New Service. From... BARRON. Spooner Office: P.O. Box 261 Spooner, WI Barron Office: P.O. Box 40 Barron, WI

PERMANENT RESIDENTIAL UNDERGROUND SERVICE

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

JACKSON ENERGY AUTHORITY ELECTRIC SERVICE POLICY EFFECTIVE SEPTEMBER 26 th, 2005 *REVISED JULY 12 th, 2017

Electric Service Guide. Residential

ELECTRIC LINE EXTENSION POLICY

7 Single Family Service

GUIDELINES FOR RESIDENTIAL ELECTRIC SERVICE HOOKUP

Customer Guide to Electric Service Requirements

Commercial Plan Submittal Form Utility Service Requirements

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

For Conduit Inspections

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

INTERMOUNTAIN RURAL ELECTRIC ASSOCIATION. Builder/Developer Information

Service Requirements

NEW SERVICE HANDBOOK

Indianapolis Power & Light Company

WPS SERVICE MANUAL. Section Amp and Smaller - Common

CHAPTER 1 INTRODUCTION

Commercial Service Workbook

SPECIFICATIONS FOR RESIDENTIAL CONSTRUCTION

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

The cost estimation methodology used to update the charges and credits is the same methodology the Company utilized in the prior year s filing.

COMMERCIAL HANDBOOK 2013 EDITION MATANUSKA ELECTRIC ASSOCIATION, INC. PALMER, ALASKA

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

See NT POWERCOS , Classification Based On Service Size.

Electric Service Guides 2017


SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

APPLICATION FOR PERMIT to construct, operate, maintain, use and/or remove within a county road right-of-way

GUIDELINES FOR RESIDENTIAL ELECTRIC SERVICE HOOKUP

GENERAL INFORMATION 1.01 PURPOSE

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

COMMERCIAL QUICK REFERENCE

WPS SERVICE MANUAL. Section 7 Clearances. 7-1 Basic Electric Clearances - Services Miscellaneous Clearances Antenna Clearances...

BGE Service Application Guidelines Residential Modification/Relocation Projects

All territory within the incorporated limits of the City and land owned or leased by the City.

Service Requirements

Electrical Safety Slide Show Presenter s Notes

1007 Elwell Court Palo Alto, CA 94303

ELECTRICAL SAFET Y FOR CONTRACTORS

Commercial Electric Policy

CONTENTS BY CHAPTER. Chapter 2: COMPANY EQUIPMENT ON CUSTOMER PREMISES

7. Residential Single-Family and Duplex Buildings (Dwellings)

1. General Requirements


Electric Service Requirements

A Homeowner s Guide to Natural Gas Service

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

Electric underground service installation requirements

SALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

ELECTRIC LINE EXTENSION POLICY

Regarding: North Industrial Park/Infrastructure Build Project - Contractor Payments

Electrical Design of Residential Services

SINGLE PHASE WIRING SPECIFICATIONS

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

ELECTRIC DIVISION RULES AND PROCEDURES FOR ELECTRIC SERVICE

THREE PHASE WIRING SPECIFICATIONS

RESIDENTIAL ELECTRICAL SERVICES Connection and General Information

ELECTRIC SERVICE MANUAL

Electric Service Requirements

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

RULES AND SPECIFICATIONS FOR ELECTRIC SERVICE

2008 Guidebook of Requirements. for Electric Service

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES

Presenter s Notes SLIDE 1. Before darkening the room, offer a welcome and overview. Begin by introducing the program and its topic:

AMENDED CULVERT POLICY WITH MAIL BOX POLICY

Revised DEC STATE OF OKLAHOMA GARFIELD COUNTY PUBLIC SERVICE/PIPELINE OWNER LINE INSTALLATION

Commercial & Industrial

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

Presenter s Notes SLIDE 1

Work safely around power lines.

Electric Service Requirements & Guidelines

The information found in this document are general guidelines that may be used to aid in the preparation of your service request proposal.

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

TYPICAL DRIVEWAY CONSTRUCTION PER DOUGLAS COUNTY REGULATIONS AND POLICIES

Engineering Rules and Regulations for Electric Service Platte-Clay Electric Cooperative, Inc.

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

Transcription:

Electrical Service Requirements TEMPORARY SERVICE TABLE OF CONTENTS PUD SERVICE TERRITORY AND CONTACTS CHAPTER ONE - INTRODUCTION Inspections and codes Underground Utility locates Meter socket requirements CHAPTER TWO - TEMPORARY OVERHEAD SERVICE Meter location Clearance requirements CHAPTER THREE - TEMPORARY UNDERGROUND SERVICE Temporary service location Trenching requirements APPLICATION FOR SERVICE RESIDENTIAL APPLICATION FOR SERVICE COMMERCIAL Note: New services (as well as rewires or panel upgrades) require engineering and construction time that may take as long as twelve (12) weeks. Normally, there are fees for establishing service, and these must be pre-paid. Electrical inspections and approval are required prior to the PUD energizing any service.

PUD Service Territory PUD Contacts Everett (Headquarters) 425-783-8272 2320 California ST Everett, WA 98201 Arlington PUD office 425-783-1000 210 E. Division Arlington, WA 98223 Lynnwood PUD office 425-783-1000 21014-63rd AV W Lynnwood, WA 98036 Monroe PUD office 425-783-1000 120 E. Fremont Monroe, WA 98272 Snohomish PUD office 425-783-1000 807 Rainier Snohomish, WA 98290 Stanwood PUD office 425-783-1000 9124-271 ST NW Stanwood, WA 98292 PUD Real Estate Services 425-783-4408 1802-75th ST SW Everett, WA 98203 Monday through Friday, 8:00 AM to 5:00 PM Toll-free in Western Washington and outside the Everett local calling area at 1-877-783-1000 OTHER UTILITIES Telephone: Frontier Gas: Water: Cable: Puget Sound Energy Cascade Natural Gas Contact your local provider Contact your local provider ELECTRICAL INSPECTIONS State of Washington L&I (Everett) 425-290-1309 State of Washington L&I (Mt. Vernon) 360-416-3000 City of Everett 425-257-8810 City of Lynnwood 425-670-5417 City of Marysville 360-363-8223 City of Mountlake Terrace 425-775-9694

CHAPTER ONE INTRODUCTION This handbook provides you with the necessary information you need to request and obtain a temporary service. Snohomish County Public Utility District #1 (PUD) defines a temporary service as a means of supplying electricity to your construction site for a maximum of 18 months. Typically, a temporary service is installed to provide power for the construction phase of your project while provisions are being made for your permanent power system. Several items need to be completed before we can energize your temporary service. They are: Call the PUD office closest to your location and ask to speak to an Area Designer to determine whether or not you have overhead or underground service available; Install your service equipment; Obtain a state or city electrical inspection and approval of your service equipment; Obtain a service inspection approval from PUD; Pay fees. The remainder of this brochure will assist you with this process. If you have any questions, please call or visit your nearest PUD office (see inside front cover) for information on permanent services, or check our website at snopud. com and search on electrical service requirements. INSPECTIONS AND CODES This handbook should be used as a guide. It does not cover all possible federal, state, or local requirements. It is your responsibility to ensure that your project complies with the most recent issue of the National Electric Code (NEC) and any other federal, state, or local codes that may apply. METER SOCKET REQUIREMENTS You are required to provide a meter socket with the following specifications: w Rated 120/240 volts w Single-phase w Minimum rating of 125 amps w Maximum rating of 200 amps w Four jaws w UL-approved (Underwriters Laboratory) The PUD will supply a meter ring. If you would like a service other than 200 amps 120/240 volt single-phase, please contact your PUD Area Designer prior to beginning construction. Snohomish County PUD Electric Service Handbook Temporary Service Rev. April 2018 1

CHAPTER TWO TEMPORARY OVERHEAD SERVICE The process and cost of obtaining your temporary overhead service can vary, depending upon the location of our existing facilities. The least complicated and cheapest way a service can be installed is if a transformer is located on a pole (see figure 3-3) on or along your property. METER LOCATION Your temporary meter post should be located on your property within 150 feet of the PUD power pole that will serve you and should be located within 15 feet of the road or driveway. Please consider the following: The path that the service line will take should not cross property belonging to other individuals. If the service line will pass through trees or brush, a 5-ft. path must be cleared to allow our service personnel to run the line and allow the lines to hang without contacting trees or limbs. Maintaining this clear path is your responsibility. The service line path should avoid areas where vehicular traffic will occur, unless your temporary service post height is increased to provide adequate clearance. (See figure 3-3 for clearance requirements.) CLEARANCE REQUIREMENTS Figure 3-3 shows the clearance requirements for the types of terrain most commonly encountered. FIGURE 3-3 PUD Facilities Service Drop Min. 24 feet Min. 18 feet Min. 15-1/2 feet Min. 10 feet Point of attachment State Highways City, County road Private road Commercial driveways Truck traffic areas Residential driveway Final Grade Porch / Deck Working Platform 2 Snohomish County PUD Electric Service Handbook Temporary Service Rev. April 2018

Figure 3-1 is a drawing of the standard temporary overhead service installation recommended by PUD. The specifications given are the minimum acceptable. Do not deviate from the installation standards without approval from your PUD Area Designer. The service conductor shall be coded and the neutral conductor shall be identified by the color white or light gray. Items owned and installed by the customer: 1. 4" x 4" x 14' minimum, continuous, single structure 2. Meter socket and distribution panel 3. Ground wire (per NEC) 4. Ground rods (per NEC) 5. 2" x 4" bracing (2 required) 6. Service entrance conductors (18" out of the weatherhead) 7. Insulator spool FIGURE 3-1 14' x 4" x 4" min. 8" min. See: BRACING TOP VIEW (below) Items owned and installed by the PUD: 1. Service Line 2. Meter Attachment insulator to be provided by customer NOTE: Customer-owned line side conductor - 18" min. if accessible by service truck (within 15' of a drivable surface). If not accessible by service truck, attach conductor to insulator and provide enough conductor to reach the ground. Point of attachment to pole must be 10' min. above ground. See Note. See: BRACING TOP VIEW (below) 6' max. 4' min. 2" x 4" min. on braces and stakes Service Clearance (refer to Figure 3-3) Grade Post must be sunk 36" min. Ground per NEC. BRACING TOP VIEW Stake NOTE: Approved service equipment provided by customer includes a suitable support post and bracing with an approved attachment insulator spool, UL-listed or approved conduit and weatherhead, meter socket, weatherproof disconnect switch and receptable box with ground wire, clamp and ground rod per NEC. Pull Service Drop Brace Temporary post Brace Stake Snohomish County PUD Electric Service Handbook Temporary Service Rev. April 2018 3

CHAPTER THREE TEMPORARY UNDERGROUND SERVICE The process and cost of obtaining your temporary underground service can vary, depending on the location of our existing facilities. If there is a transformer or power pedestal located on your property (see figures to the right), engineering may not be required. Simply install your temporary service equipment (figure 4-13) and obtain inspections from the State or the City, and the PUD. If you have questions about our facilities, contact your PUD Area Designer. TEMPORARY SERVICE LOCATION The following items are required to properly locate your temporary service equipment: Set the equipment on your property no closer than 3-ft. from the power pedestal. Place bracing and temporary pole away from future service trench location. FIGURE 4-4 Support Post 4" x 4" min. Meter Socket All bracing shall be located so that it does not go over the top of the workpit and out of the way of workers. Braces & Stakes 2" x 4" min. See Note 1 6' max. 3' min. Existing Grade Located ground rod on the back side of the temporary post out of the workpit and not in the way for workers. Ground rod, wire and clamp provided by customer per NEC. 45 angle typical 36" min. 36" min. 24" min. Leave enough wire for connection in pedetal 4' min. 5' max. from bottom of ditch at pedestal end. DO NOT ENTER PEDESTAL. Locate temporary on either side of the pedestal (longest sides). Do NOT locate temporary on front or back side of pedestal (shortest sides). Coil or lay conductor to maintain a 24" depth or excess conductor will be cut off by the PUD. Power Pedestal 4 Snohomish County PUD Electric Service Handbook Temporary Service Rev. April 2018

TRENCHING REQUIREMENTS It is your responsibility to provide a buried cable from your temporary meter base to our power pedestal. The trenching requirements to connect to a hand hole are shown in figure 4-13. The cable you install should be sized per the NEC and should have a minimum cover of 24". Trench to the nearest side of the power pedestal and leave your wires exposed. If you discover any other conductors while digging your trench, please leave them covered. The customer shall provide select backfill (no rocks) for the PUD to use in shading the area conductors after energizing them. Sand shall be required if select backfill material is not available. The select backfill or sand shall provide a 3" bedding below conductors and a minimum cover of 3" above conductors. The customer shall backfill the entire temporary service excavation within 24 hours after the PUD has energized and shaded the service conductors. Figure 4-4 illustrates the recommended temporary underground service installation. Please note the dimensions shown. Deviations to this recommended standard could result in a delay in receiving your service and/or your service being denied. Items owned and installed by the customer: 1. 4" x 4" x 10' continuous single structure 2. 2" x 4" bracing (post should be braced from two directions) 3. Meter socket and distribution panel 4. Ground wire (per NEC) 5. Ground rods (per NEC) 6. Service entrance conductors (per NEC), leave 5-ft. additional at PUD power pedestal Items owned and installed by the PUD 1. Meter Remember that you are required by law to call the UULC (1-800-424-5555) and request buried utility locations 48 hours (two working days) before digging. Any trenching within 24" of existing underground facilities must be done by hand. Snohomish County PUD Electric Service Handbook Temporary Service Rev. April 2018 5

1097R REV. 05/08 Customer s Name (LEGAL NAME FOR CONTRACTS) RESIDENTIAL NEW SERVICE QUESTIONNAIRE / AGREEMENT SNOHOMISH COUNTY PUD Phone: Work ( ) home ( ) Cell ( ) FAX ( ) email Service Address Mailing Address (HOUSE NUMBER AND STREET ADDRESS, CITY, STATE, ZIP CODE) (HOUSE NUMBER AND STREET ADDRESS, CITY, STATE, ZIP CODE) Architect/Surveyor Work Phone ( ) Electrical Contractor email Phone: work ( ) FAX ( ) CelL ( ) General Contractor email Phone: work ( ) FAX ( ) Cell ( ) House Mobile Home Other (PLEASE SPECIFY: RECREATIONAL VEHICLE, PUMP HOUSE, GARAGE, ETC.) PUD Main Line on your property to be: Overhead Underground Service Line (transformer to residence) to be: Overhead *if Underground: PUD installed Underground* Customer installed Electrical service entrance size: 200 amp 400 amp amp In order to proceed with the engineering and determination of charges, the following information may be required: 1. Copy of the survey for the property showing lot lines, property corner stakes, dimensions, easements and right-of-way. Attached? Yes No 2. Legal description of property (copy of deed). Attached? Yes No 3. Plot plan of lot showing approximate locations of buildings, driveways, and proposed electrical facilities and service location. Attached? Yes No 4. Snohomish County or appropriate governmental agency Critical Area Regulation or other requirements have been met and details attached? Yes No (If NO, information must be provided to the PUD before proceeding with engineering) ELECTRICAL INFORMATION Type of heat: Electric Gas Wood Other (specify) Type of electric heat and kilowatt (kw) load: Furnace kw Air Conditioning: Heat Pump: tons Wall kw Amps starting current Amps starting current Baseboard kw Amps running current Amps running current Boiler kw Soft start: Yes No Soft start: Yes No Other kw Hot Water: Miscellaneous Loads: Gas Electric kw Tankless kw Hot Tub kw Pool kw Sauna kw Welder kw Other (specify) kw Approximate date service will be required: Present condition of building site: Grades & Stakes Form signed?: Yes No (This is a form attesting that property corner locations and final grade is ESTABLISHED.) It is understood that if additional work is required of the PUD, due to customer revisions of the electrical load and/or voltage requirements or other information as supplied or requested on this form, the additional costs shall be borne by the customer. The PUD provides for installed load, not future load. Prior to energizing the service, all PUD standards and service requirements must be met and approved by the PUD. Customer Signature date:

1097C REV. 05/08 COMMERCIAL NEW SERVICE QUESTIONNAIRE / AGREEMENT SNOHOMISH COUNTY PUD Customer s Name email (LEGAL NAME FOR CONTRACTS) Phone: Work ( ) home ( ) Cell ( ) FAX ( ) Service Address (NUMBER AND STREET ADDRESS, CITY, STATE, ZIP CODE) Mailing Address (NUMBER AND STREET ADDRESS, CITY, STATE, ZIP CODE) Architect/Surveyor Work Phone ( ) Electrical Engineer or Contractor email Phone: work ( ) FAX ( ) Cell ( ) Project Coordinator email Phone: work ( ) FAX ( ) Cell ( ) If job is not yet bid out, what is the expected bid date? Grades & Stakes form signed?: Yes No Approximate date service will be required: Type of financing: Cash Letter of Guarantee Performance Bond In order to proceed with the engineering and determination of charges, the following information may be required: 1. Snohomish County or appropriate governmental agency Critical Area Regulation or other requirements have been met and details attached? Yes No (If NO, information must be provided to the PUD before proceeding with engineering) 2. Three complete copies of the sites plan (including water, sewer and storm) - one electronic file preferred 3. Legal description (include copy of deed) 4. Complete riser diagram 5. Desired metering location (one location per building) and Desired Transformer Location 6. Will existing power facilities require relocation? Yes No (if yes, mark on site plan) REQUIRED ELECTRICAL INFORMATION Electrical service entrance size: 200 amp 400 amp amp Overhead Underground Voltage / Single-Phase Three-Phase Service entrance: total number of conductor runs: Phase Wire Size Neutral Wire Size Type of heat: Electric Gas Wood Other (specify) Type of cooling: Electric Gas None Other (specify) Type of Business: business Sq. Footage: Will there be any generation at this facility? o Yes o No If Yes, what kind of interconnection do you intend on using? o Open Transition o Closed transition Total Electrical Load: existing new voltage Phase Lighting kw kw Heating kw kw Air conditioning kw kw Water Heating kw kw Motors kw kw (please describe details below) Miscellaneous kw kw Total: kw kw Motors* (characteristics of proposed load): Size in HP Quantity Soft start? Starting Running Phase Class Voltage No. of Per Y yes or No amps amps starts Day or Hour *Please attach additional sheet with identical category listings if you need more room. It is understood that if additional work is required of the PUD, due to customer revisions of the electrical load and/or voltage requirements or other information as supplied or requested on this form, the additional costs shall be borne by the customer. The PUD provides for installed load, not future load. Customer Signature date:

This page intentionally left blank.

Call two (2) full working days before you dig! It s a required by law, and you could be held liable for any damages you incur to utility services Call 811 or 1-800-424-5555 At no charge to you, Utilities Underground Location Center (DIAL DIG) will mark where power, gas lines, and other utilities are located on your property, using the following color codes: RED... Electric YELLOW... Gas Oil ORANGE... Telephone CATV BLUE... Water GREEN... Sewer PURPLE... Reclaimed Water PINK... Survey WHITE... Proposed excavation

PO Box 1107 Everett WA 98206-1107 425-783-8272 snopud.com FORM 1539 Rev. 04/18