HYDROCYCLONE SAND SEPARATORS

Similar documents
IRRIGATION EQUIPMENT LTD.

SCREEN FILTERS Series 2000 & 2200

BERMAD Irrigation. Media Filtration Systems. Model Filters. Features and Benefits. Typical Applications

SERVICE & OPERATING MANUAL

ARKAL FILTERS CATALOGUE

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

APOLLO DISC-KLEEN FILTERS

Aries Technical Information. Features and Benefits. Integral dripper

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

Spin Klin 12" Super Flow

ejpx High Efficiency Liquid-Solid Separator ejpx Features and Benefits:

VAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR

INTEGRAL DRIPPER, HEAVY WALL DRIPPERLINE

MODEL 200 MULTI-JET FLOW METER

WARCO CHEMAG SERIES GH FILTERS

area

MODEL 200 MULTI-JET FLOW METER

New Filtration Products from LAKOS

UNIRAM CNL TECHNICAL INFORMATION

Thompson Strainer MLS-2

DOROT CONTROL VALVES CATALOGUE

UNIRAM HCNL TECHNICAL INFORMATION

PUMPS AND FILTRATION

PLASTIC Filters. Durable high quality Plastic filters for wide range of filtration applications

SMART SOLUTIONS FOR WATER Product Brochure Waterworks Fire Protection Irrigation Filtration

HTX-HTH SEPARATORS I&O MANUAL

Super Gal. Super Gal. Model 75 - High Capacity Plastic Control Valve. Product Catalogue. Super Gal Catalogue. Model 75.

To ensure proper installation, digital pictures with contact information to before startup.

Top Drip. Heavy-Wall Emitterline

Introduction. Operation FTG 600

SEMI-AUTOMATIC Filters. Quick and efficient way for cleaning manual filters

Pumps and Filtration

Spin Klin 3"-4" Apollo Angle

Operation and Maintenance of Mechanical Self-Cleaning Filters. Maynard King CB Tubecraft div of K&D Pratt

4" Spin Klin Twin Apollo Battery. Service & Maintenance Manual

Spin Klin 4" Apollo Twin

PCJ DRIPPER APPLICATIONS FEATURES AND BENEFITS SPECIFICATIONS COMPACT ON-LINE PRESSURE-COMPENSATING, CONTINUOUSLY SELF-CLEANING DRIPPER

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

Filtration Ft-Line 34. Ck-Line 38. Cp-Series 42. FilterMax 46. Cintropur filtration 51. Cartridge housings

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

MODEL 900 IMPELLER-TYPE FLOW METER

ARIES THINWALL DRIPLINE

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

M300 Filters. Versatile and efficient self cleaning hydraulic filters that require no external power source

Model 1100 Turbine Flow Meter

SST & PRO II Media Filtration Systems Installation and Operation Instructions

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

OPERATING AND MAINTENANCE MANUAL BATCH PRESSURE FILTER 3 GALLON CAPACITY

Check List for Optimal Filter Performance

Chemical disc filters, Arkal Amiad, w w w. a r k a l - f i l t e r s. c o m

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

ENGINE COOLING Click on the applicable bookmark to selected the required model year

UNIRAM AS TECHNICAL INFORMATION

Leaflet F UK FLUXA

PRO II & SST Media Filtration Systems Installation and Operation Manual

Wedge Wire Strainers

Product Catalogue. Series 75 Valves. Valves. Catalogue. Series 75. Edition 09/2017

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Agxcel GX12i Chemical Injection System

Irrigation Systems. Product Catalog. Yardney Water Management Systems, Inc Box Springs Blvd. Riverside, CA 92507

BGT Series. Low Pressure Filters

DRIPPERLINES, DRIPPERS & OTHER EMITTERS PRODUCT CATALOG

VDF (Vortex Dynamic Filter) Instruction Manual CL-MR-series models

PRESSURE REDUCING CONTROL VALVE

FROM A LEADER IN CLEAN AIR TECHNOLOGY

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Filtomat M100/MG Filters

inlet/outlet connection flow rates filtration degrees max. working pressure

MODEL NO GALLON H.P. SKID SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

THIN TO MEDIUM-WALLED PC FLAT DRIPLINE. TopDrip PC. TopDrip PC AS 1.0, 1.6, 2.0, 2.2 l/h 1.0, 1.6, 2.0, 2.2 l/h

Streamline Applications: Specifications: Features and Benefits: Integral dripper

Spray Pressure Control Manifold

Low Profile J Series Power Unit with Vane Pump

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

1/2" AIR DRIVEN DIAPHRAGM PUMP

UNIRAM AS XR TECHNICAL INFORMATION

Standard Package Systems Product Focus. Now, More Choices In Vickers Power Unit Offerings. Whatever the Industry. Whatever the Application.

Replacing the Internal Oil Filter Elements for HS85 and OS 85 Screw Compressors

LAKOS AUTOMATIC SELF-CLEANING SCREEN FILTERS

ENGINE COOLING SYSTEM

PAHT pump PAHT X

Hydrosafe - Model HSFS

AGN 065 Air Inlet Filters

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

Cartridge Filter Housings Nowata A Series

EJECTORS GENERAL OPERATION & MAINTENANCE MANUAL

Filtration in Larger and Smaller Breweries

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

Spray Pressure Control Manifold

PRESSURE REDUCING VALVE

TAVLIT FILTERS. Quality that lasts

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)

GB-250. Submittal Specifications Installation Application Specific Details

Constant Flow Valves. Specifications PVC: 1/2", 3/4", 1", 2", 3", 4" PVC PVC Flanged ANSI EPDM Stainless Steel 304 with ETFE Coating º F

F76 Water Filters. Specifications. and MV876 Automatic-Backwash Control Accessory (not included)

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Vane Pumps. Single Stage Single and Double Vane Pumps. Vickers. Overhaul Manual

Transcription:

FILTRATION HYDROCYCLONE SAND SEPARATORS OPERATION, INSTALLATION & MAINTENANCE GUIDE HYDROCYCLONE & SEDIMENTATION TANK

DESCRIPTION A Hydrocyclone separates sand and other solid matter from water with very little head loss and 90% or better efficiency. There is no head loss build up and no clogging when the solids are separated. Hydrocyclones are easy to operate and maintain, and have no moving parts or screens. Versatility in system configurations and ease of installation are some of its great advantages. A Hydrocyclone uses a tangential injection flow process, enhancing the centrifugal forces and moving solid particles outwards. The dispersed particles move downward in a spiral path into an underflow chamber (sedimentation tank) while clean liquid moves upwards to the center of the spiral, towards the top outlet. A specially designed rubber insert protects the neck of the Hydrocyclone from erosion and increases separation efficiency. The Sedimentation Tank can be drained automatically with an automatic flushing kit (an electric valve, controller and small command filter). Automatic flushing will not interfere with the proper functioning of the Hydrocyclone. The Hydrocyclone has a 100 micron protective coating of extra durable polyester applied electrostatically and oven cured on a zinc-phosphate layer for maximal anti-corrosion protection. Hydrocyclone Flow and Mode of Separation 2 HYDROCYCLONE SAND SEPARATORS

SPECIFICATIONS As a rule, the separation efficiency improves as the Hydrocyclone diameter decreases and the head loss increases. Miniature Hydrocyclones may be used for easy sampling of liquids, for determining filter (including larger Hydrocyclones) operation and efficiency and for testing the feasibility of operation for the problem at hand. Each filter is designed and manufactured in order to achieve the highest standard of quality and finish. Recommended head loss for effective operation: 3-8 psi Maximum recommended working pressure: 120 psi Maximum pressure: 150 psi Water inlet and outlet: horizontal and vertical Inserts: standard on all sizes except 3 and 4 Protective coating: polyester on zinc-phosphate layer Pressure relief valve: must be inserted before the filtering installation if pressure is not controlled Available sizes: 1,2 3, 4, 6, 8, 12, 16, 20, 24 and 30 End connections: Thread (TH), Flange (FL), Groove (GR) Sedimentation Tank connections: Thread: 3 and 4 sizes Flange: 12, 16, 20, 24 and 30 sizes Groove: 6 and 8 sizes RECOMMENDED FLOW RATES INLET/OUTLET HYDROCYCLONE STANDARD SEDIMENTATION MODEL DIAMETERS (IN) FLOW RANGE (GPM) TANK CAPACITY (GAL) 24HC3 ľ TH 9-15 0.5 24HC4 1 TH 15-33 0.5 24HC6 1 TH 33-53 2.6 24HC8V 2 GR 48-75 2.6 24HC8HV 3 GR 80-150 2.6 24HC12F6 4 IN & 3 OUT FL 150-230 16 24HC16F6 4 FL 230-360 32 24HC20F8 6 FL 430-700 58 24HC24F8 6 FL 615-1,000 58 24HC30F8 8 FL 1,000-1,600 85 OPERATION Based on the centrifuge principle, the particles are spun against the outside wall of the Hydrocyclone and gravitate towards the bottom into the Sedimentation Tank. The velocity at which the water flows through the Hydrocyclone determines the efficiency at which the particles are separated from the water. Normal working conditions are achieved when headloss on the Hydrocyclone is not less than 3 psi with a recommended range of 3-8 psi. A headloss of less than 3 psi will reduce the separation efficiency and a headloss of more than 8 psi might induce increased erosion. The Hydrocyclone is designed for a maximum recommended working pressure of 120 psi and should not exceed 150 psi. HYDROCYCLONE SAND SEPARATORS 3

INSTALLATION Install and connect the Hydrocyclone vertically with the Sedimentation Tank underneath the Hydrocyclone. Special attention must be given to the correct flow direction: horizontal inlet and top vertical outlet are clearly marked by arrows. Install the manual ball valve to the flush port of the Sedimentation Tank. Check that the actual flow rate through the Hydrocyclone is within the recommended range. Inadequate flow rate will result in reduced performance. If more than one Hydrocyclone is installed, leave sufficient space between units to facilitate maintenance. Specially designed manifolds are available for mounting multiple filters. A pressure relief valve must be installed upstream of the Hydrocyclone if the pressure is not controlled effectively. INSTALLATION WITH OPTIONAL AUTOMATIC FLUSHING KIT Automatic Flushing Kit includes an electric valve, controller and small command filter. Install the elect ric valve on the outlet opening of the Sedimentation Tank. Connect the controller to the electric valve. Insert the batteries inside the controller (or plug in for AC) and close the cover tightly. Adjust the controller as follows: - Flushing time for Sedimentation Tanks with 1.3-16 gallons: 15-20 seconds - Flushing time for Sedimentation Tanks with 32-85 gallons: 30-40 seconds - Time between flushings: 30-120 minutes - If the water contains high loads of dirt, shorten the time between flushings. Multiple Hydrocyclone and Sedimentation Tank Installation 4 HYDROCYCLONE SAND SEPARATORS

SEDIMENTATION TANK FLUSHING The Sedimentation Tank can be flushed manually or automatically with an irrigation controller or computer at periodic intervals. When a manual valve is installed, drain the Sedimentation Tank at periodic intervals according to the recommendations. The Sedimentation Tank should be drained when it is 1 3 full. Do not let the Sedimentation Tank get filled more than of its volume, otherwise the sand will not flush properly. As a result, the sand will spin, have no place to drain, and cause pin holes in the neck of the Hydrocyclone. SEDIMENTATION TANK PERIODIC CLEANING Check that the rubber insert is not worn or damaged and replace if necessary. When separating sand, the rubber insert may need to be replaced every 2-3 years. When separating silt, the rubber insert may need to be replaced every year. Close the valve at the inlet of the Hydrocyclone. Open the drain valve located at the bottom of the Sedimentation Tank to release pressure and drain. Take off the cover. Remove all the sediments collected in the Sedimentation Tank. Thoroughly rinse the inside of the empty Sedimentation Tank. Replace the cover on the Sedimentation Tank so that the cover gasket fits over it. Mount tightening bracket and tightening handle properly. WARNING: Do not tighten or open cover during operation or under pressure. MAINTENANCE Apply a layer of grease to handle threads once a year. Immediately repair any damage to the tank s protective coating. HYDROCYCLONE SAND SEPARATORS 5

TECHNICAL DATA HYDROCYCLONE MICRON/MESH MESH 120 140 180 MICRON 130 105 90 200 270 325 600 75 53 44 25 Pressure (psi) 15 HEADLOSS 10 8 3 6 6 5 4 3 2 4 8 8H 16 24 Recommended Range 12 20 30 7 6 Pressure (psi) HYDROCYCLONE (Particle size separation in Micron) 10 9 8 5 4 3 6 8H 16 24 4 8 12 20 3 5 10 20 30 40 50 100 200 300 500 1000 2000 20 30 40 50 100 Gallons per Minute Micron DIMENSIONS & WEIGHT MODEL B (IN) D (IN) H (IN) H1 (IN) H2 (IN) L (IN) T (IN) WEIGHT (LBS) WEIGHT W/SEDIMENTATION TANK (LBS) 24HC3 ľ 3 16** 12.6 11.2 4.7 1.2 18 31 24HC4 1 4 18** 15 13.6 5.5 1.6 20 44 24HC6V 1 6 26** 20.3 16.7 9.5 2.4 40 76 24HC8V 2 8 29** 22.6 20.9 11.6 3.2 44 80 24HC8HV 3 8 33** 26 24.6 11.8 2.6 60 96 24HC12F6 4 IN & 3 OUT 12 52 44.5 28.5 19.7 4.1 146 221 24HC16F6 4 16 68 58.3 38.2 23.6 5.7 276 420 24HC20F8 6 20 75 63.4 45.3 23.6 6.7 379 571 24HC24F8 6 24 85 73.2 55.3 23.6 8.7 452 644 24HC30F8 8 30 111 93 75.8 27.6 10.4 770 962 ** Height for sedimentation tank without legs 6 HYDROCYCLONE SAND SEPARATORS

REPLACEMENT PARTS HYDROCYCLONE & SEDIMENTATION TANK PARTS KEY ITEM NUMBER MODEL NUMBER DESCRIPTION 1 2 70020-007450 70020-007720 44E000101 44E000214 Handle Tightening Bracket 70020-007500 70020-007700 44E000100 44E000216 Handle Tightening Bracket - 44E000240 Side Port Cover 3 70020-008000 44E000260 Side Port Cover 70020-007900 44E400260 Side Port Cover 70020-008070 44E001340 Side Port Neoprene Cover Gasket 4 70020-008350 44E001361 Side Port Neoprene Cover Gasket 70020-008200 44E004365 Side Port Neoprene Cover Gasket 70020-015200 24E545950 Rubber Insert 5 70020-015230 24E550952 Rubber Insert 70020-015250 24E560952 Rubber Insert - 70021-000730 24HCTESTER Hydrocyclone Tester Kit - 33500-002100 44Z400409 Hydrocyclone Glass Tube - 70020-016175 44Z209 Hydrocyclone Nut & Washer for Tester Kit USED WITH SEDIMENTATION TANK OR HYDROCYCLONE MODEL NUMBER 24ST002L 24ST010FLV2 24ST002L 24ST010FLV2 24ST002L 24ST010FLV2, 24ST060F6 24ST120F6, 24ST220F8 24ST002L 24ST010FLV2 24ST060F6, 24ST120F6, 24ST220F8 24HC8V, 24HC8HV 24HC12F6, 24HC16F6 24HC20F8, 24HC24F8, 24HC30F8 - - - HYDROCYCLONE SAND SEPARATORS

CUI: 17300355 J23/451/01.03.2005 Strada Costache Negri Nr. 28 / Sector 5 / Bucureşti / România / www.aquatech.ro Banca Romaneasca Suc. Gara de Nord CONT : RO11 BRMA 0999 1000 4398 3579 Tel: 021 411 2000/021 411 3000/021 311 4686/ Fax: 021.4113388/ office@aquatech.ro