Digi- Motor Genera.on 2

Similar documents
Digi- Motor MARS No / 10861

ECM. marsdelivers.com. Delivering Confidence 7/15

ECM. marsdelivers.com 7/15

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. CHECK OUT THE NEW EVERGREEN PF & OM INSIDE!

ELECTRONICALLY COMMUTATED MOTOR

Electronically Commutated Motor Wiring Manual

The ECM Textbook.

WARNING WARNING WARNING WARNING WARNING WARNING WARNING

The ECM Textbook ECM. Table of Contents. - Overview of ECM Technology. - Indoor Blower Motors o Variable Speed ECM o Constant Torque ECM

30% and Higher Energy Savings with EC Motors. BUILDINGSNY.COM Javits Center, NY March 21-22, 2017

RESCUE EcoTech Motor. Installation Guide NIDEC MOTOR CORPORATION

MotorPro Training RESCUE

A French company based in Paris

Achieve Up To 200% Greater Efficiency And Better Air Flow Performance With GE ECM Technology

Fan Coil Unit (FCU) Fan Motor Control

Spring 2018 U.S. MOTORS Preseason

MHS 2018 MARS HEATING SPECIAL

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Rotary Screws Pumps

MB6(B,E,V)M Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Modular Indoor Blower 13+ SEER Residential System. Additional MB6EM Features:

ARUF Series Multi-Position

Installation instructions for KIT15017, KIT15018, KIT15019, and KIT15020

TOTALINE PROTECTION CONTROLS

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

Products for Indoor Air Quality and Control

MotorPro. ECM Troubleshooting Guide

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

SPECI. . Up to 21 GPM. Flow. Steel. Bellows O ring/flapper. Mechanical Seal. Carbon/Ceramic/Viton. The. stainless NPT.

EconoMi$er, Power Exhaust, and Sensor Installation Instructions

"Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Carol Lewellen-NEEC and BOC Tuesday, May 8, Sessions Session

V-BELT DRIVES AND BEARINGS

HVACR Electrical Systems

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Grid connected battery energy storage

AFTERMARKET MOTOR & ACCESSORIES GUIDE

NIDAC EMC Communicating Motor

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Change the and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat

Chinook Gas Furnace Multi-Position High Efficiency Condensing Furnace

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAST UNIVERSAL AFTERMARKET MOTORS

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

HVAC Motors Three Phase, TEFC, Foot Mounted, with Internal AEGIS

SECTION MOTOR REQUIREMENTS for HVAC

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

INSTALLATION INSTRUCTIONS

JARD by MARS JARD by MARS

Electric Rotary Knob BILLET CONTROLS INSTALLATION INSTRUCTIONS

UNIVERSALELECTRICMOTORS MOTORCATALOGUE NEWTHISSEASON WEDOMOTORSBEST.

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

Your FAST Parts distributor has a full line of reliable replacement aftermarket motors & accessories at affordable prices.

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Part # Features & Applications Specifications Cross Reference

HVACR Controls by ICM

AWUF, AWUT Series. Wall-Mount Air Handler 1½ to 3 Tons. Contents. Product Features

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Motors & Drive Components

Electronic Refrigerator Diagnostics

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Electricity Distribution and Underground Networks

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

INSTALLATION/OPERATING INSTRUCTIONS TSC

INSTALLATION INSTRUCTIONS

FORM NO. HSC-543 AIR HANDLERS

ASPT Multi-Position Air Handler

Optimized Idle Aftermarket Installation Kits On-Highway Truck Applications (P/N: )

M O D E L USER MANUAL FLIGHT SYSTEMS FLIGHT SYSTEMS

SECTION COMMON MOTOR REQUIREMENTS FOR HVAC EQUIPMENT

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

INSTALLATION INSTRUCTIONS

REPLACEMENT PARTS ILLUSTRATION

2011 International Comfort Products, LLC

Idle Free Systems, Inc. Reference Guide System Component Information

Outdoor Enclosure Power System ENC X100MP48F20

Service Facts. WARNING: HAZARdOuS VOLTAGe - disconnect POWeR and discharge 4TTX6048-SF-1K. ComfortLink II System Cooling 4TTX6048C1000A.

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

IMPORTANT ATTENTION INSTALLERS:

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

Air Purifiers Product Guide

Micro-Air Corporation Route 526 Allentown, NJ 08501

ARUF. 1½ to 5 Tons. O when tested in accordance with ASHRAE standard 193 Cabinet air leakage less than 1.4% at 0.5 inch H 2

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

Service Facts. WARNING: HAZARdOuS VOLTAGe - disconnect POWeR and discharge 4TWX6024-SF-1K. ComfortLink II System Heat Pump 4TWX6024C1000A.

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

Motor Basics AGSM 325 Motors vs Engines

4-in-1 MOTORS ONE SIMPLE CONNECTION

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Transcription:

Digi- Motor Genera.on 2

1. Overview Azure Digi- Motor Genera.on 2 2. Azure Digi- Motor vs. Azure Digi- Motor (genera8on 2) 3. Key Features 4. Construc8on 5. Set- Up & Installa8on

Overview

Overview Azure Digi- Motor Genera.on 2 Azure Digi- Motor: Blower Motor Mul8- Horsepower ECM (1/5 HP 1 HP) for air handlers, heat pumps, fossil fuel/electric heat, and AC systems, etc. Only two motors to stock: 1. MARS No. 10860 : 1/5 HP to 1/2HP, 115/230V, reversible rota8on, (replaces original 10800) 2. MARS No. 10861: 1/2 HP to 1 HP, 115/230V, reversible rota8on, (replaces original 10801)

Overview Azure Digi- Motor Genera.on 2 Applica.ons for Azure Replaces Genteq/GE OEM ECM X- 13 motors Ø Emerging opportunity as warran8es expire Ø 5,000,000 motor installed base Ø OEM replacement X- 13 motors are expensive Ø NOTE: Azure does not replace Genteq 2.0, 2.3, 2.5, and 3.0 ECM; Azure replaces motors marked X- 13 (on motor label) BONUS: Replaces standard PSC motors, too Ø 65,000,000+ of these old motors Ø Nice upgrade opportunity Ø Nice truck motor for ALL service calls

Overview Azure Digi- Motor Genera.on 2 Origin of the Azure Digi- Motor The Digi- Motor has been in existence for 6 years as a basic OEM ECM type motor and is currently trusted by Carrier, Trane, York, Goodman, Nordyne, and MARS.

Overview Azure Digi- Motor Genera.on 2 Origin of the Azure Digi- Motor MARS conceptualized and specified the unique features of the Azure Digi- Motor specifically for the HVAC aeermarket; Ø Broad Ocean Motor Company manufactures Azure for MARS using the OEM version of the Digi- Motor as a basic building block. The genera8on 2 Azure Digi- Motor is the second and latest genera8on featuring the most innova8on of any aeermarket HVAC EC motor available today.

Two Motors Replace: Overview Azure Digi- Motor Genera.on 2 ALL Evergreen AH, IM, and EM motors by Genteq ALL Ecotech Rescue motors by US Motors ALL standard PSC type motors 1/5 HP to 1 HP ALL Genteq X- 13 motors 1/5 HP to 1 HP Both original Azure Digi- Motors (10800 & 10801) NOTE: Azure does not replace Genteq 2.0, 2.3, 2.5, 3.0, 5.0 or EON motors

Azure Digi- Motor vs. Azure Digi- Motor Genera.on 2

NEW Feature Digi+MotorDigi+Motor 85%peakefficiencyelectronicallycontrolled blowermotor;compatiblewithairhandlers, heatpumps,electricandfossilfuelfurnaces andairconditioners. TwomotorSKUsreplaceallstandardPSC andoemecm(xg13)typemotorsupto 1HP;usessimplejumperstrapstoset voltage(115/230v)androtation(cw/ccw). Autosizes speedtapconfigurationto optimizeperformanceineachapplication. Replaceableoutboard6KVsurge protectionaswellasinboard4kv protection. DropGinreplacementforstandard PSCblowermotor,wiresconnectthesame asstandardpscmotor. ConfigurabletoreplaceOEMECM(XG13) usingasimplejumperwiretodetermine& & PSCorXG13modeofoperation.Noneed forspecialsetupprogrammingprocedure. Fieldprogrammablecapabilityallows finetuningofmotorperformanceusing ahandheldprogrammer;noneedto purchaseandinstallapwmcontroller foreachapplicationdesiringcustomtuning. Generation2 YES& & & &YES& YES& & & &YES YES& & & &YES& YES& & & &YES& & NO& YES NO & NO & YES YES&

Key Features

High Efficiency ECM (85% peak) Lower opera8ng cost & possible energy rebate Self Programming Key Features Azure Digi- Motor Genera.on 2 Automa8cally sizes itself to the applica8on at ini8al start- up for op8mal performance Field Programmable (with op.onal controller) Allows custom tailoring of Azure to the applica8on Programmer is a portable tool that unlike a PWM controller does not need to be installed into they system.

Key Features Azure Digi- Motor Genera.on 2 Op.onal Hand Held Programmer (MARS No. 08502) Increase speed for high al8tude applica8ons Decrease speed for high humidity applica8ons Duplicate speeds on any of the 4 speed taps Op8mize blower performance in mul8- stage systems Cost is about the same as a single PWM control card Works with ALL genera8on 2 motors Displays % of torque being applied by the motor on the tap being energized.

Two Stage Surge Protec.on Replaceable outboard 6,000V protector (Wire harness allows easy bypass of this surge protector) Permanent inboard 4,000V protector Constant Torque Design Maintains CFM as filter becomes dirty Compact Motor Shell Key Features Azure Digi- Motor Genera.on 2 1/2HP is 5/8 shorter than Evergreen 1HP is 1-1/8 shorter than Evergreen

Inventory Reducer 2 motors cover all PSC/X- 13 blower motor applica8ons up to 1HP; 115/230V and CW/CCW Simple Wiring Key Features Azure Digi- Motor Genera.on 2 Connects exactly like a PSC motor (capacitor not needed) Connects exactly like an X- 13 motor Gentle Start Opera.on Eliminates blast of air at start- up

Construc.on

Construc.on Azure Digi- Motor Genera.on 2 Standard 48 frame 5.5 diameter Ball Bearing Design Epoxy Encapsulated electronics Protects from moisture and vibra8on

Construc.on Azure Digi- Motor Genera.on 2 Bypassable External 6KV Surge Protector (4,000V secondary protec.on remains inside motor) Failed surge protector can be removed and the harness can be reconnected without the external surge protector (if a replacement is not readily available). (Reconnect without protector)

Construc.on Azure Digi- Motor Genera.on 2 Integrated Wire Jumpers Configura8on jumpers are actually part of the wire harness and cannot be lost like separate clip type jumpers. Connect or disconnect for desired opera8on. Red: Voltage White: Rota8on Blue: Mode of Opera8on (PSC or X- 13)

Set- up & Installa.on

Set- Up & Installa.on Azure Digi- Motor Genera.on 2 1. Set Motor Voltage Red Jumper Close for 120V Open for 240V 2. Set Motor Rota.on White Jumper Close for CWLE Open for CCWLE

Set- Up & Installa.on Azure Digi- Motor Genera.on 2 3. Set Motor Mode of Opera.on Blue Jumper Close for PSC Open for X- 13 3A. Insert X- 13 PC Board Into Wire Harness (for X- 13 applica8ons, only)

Set- Up & Installa.on Azure Digi- Motor Genera.on 2 4. Install Azure Digi- Motor into blower Install with the wire harness between 4 and 8 o clock to minimize chance of moisture entering the motor where the wires enter the module.

Set- Up & Installa.on Azure Digi- Motor Genera.on 2 Auto Sizing & Connec.ng Azure For PSC Motor Applica.ons

Auto Sizing The Azure Digi- Motor PSC Mode RED SPEED TAP (5) To L1 WHITE To Neutral GREEN/ BROWN To 24V WHITE To Common From Motor 1) Make Connec8ons 2) Apply power; motor runs 2 minutes and stops 3) Remove brown/white harness & red speed tap (5) 4) Connect desired 115V speed taps 5) Test opera8on To Ground From Motor

Connec.ng The Azure Digi- Motor PSC Mode MULTI COLOR SPEED TAPS To 115V Blower Motor Speed Control WHITE To Neutral GREEN/ Basic 4 speed HVAC control board To Ground Same connections as PSC motor; but no capacitor From Motor

Connec.ng The Azure Digi- Motor PSC Mode Op.ons For Constant Fan Opera.on 1. Connect orange speed tap 1 to FAN terminal (if equipped) on system control board. 625 RPM will be controlled by thermostat. Or 2. Connect orange speed tap 1 to LINE POWER. 625 RPM will be controlled by main power to HVAC system. Thermostat can be lee in AUTO mode; motor will run at 625 RPM 24/7 (unless there is a call for heat/cool). Or 3. Install MARS Constant Fan Kit (MARS No. 08595).

Connec.ng The Azure Digi- Motor PSC Mode Constant Fan Kit (MARS No. 08595) Kit includes (1) SPST relay and (3) 24 lengths of pre- terminated leads. Notes on Installation: Disconnect G wire between T-Stat and HVAC system control board. Some systems energize Y and G simultaneously for AC and constant fan; if so, jumper G and Y together on HVAC system control board.

Set- Up & Installa.on Azure Digi- Motor Genera.on 2 Auto Sizing & Connec.ng Azure For X- 13 Motor Applica.ons

Auto Sizing The Azure Digi- Motor X- 13 Mode From HVAC System BROWN To 24V WHITE To Common From Motor 1) Make Connec8ons 2) Apply power; motor runs 2 minutes and stops 3) Remove brown/white harness 4) Connect desired 24V speed taps 5) Test opera8on Azure plugs directly into the HVAC system wire harness. Just connect the 24V speed tap(s) and the job is complete. In fact, the connec8ons for Azure and X13 are iden8cal. Note: The only difference will be that Azure has 5 speed taps from which to select, and the OEM X13 will have only the number of taps needed for the applica8on. Factory Harness Power Harness From Azure Motor

Connec.ng The Azure Digi- Motor X- 13 Mode From HVAC System Low Med High Azure plugs directly into the HVAC system wire harness. Just connect the 24V speed tap(s) and the job is complete. In fact, the connec8ons for Azure and X13 are iden8cal. Note: The only difference will be that Azure has 5 speed taps from which to select, and the OEM X13 will have only the number of taps needed for the applica8on. Factory Harness Power Harness Same connections as OEM X-13 24V Speed Tap Harness From Azure Motor One Lead to Cool on TStat Y (Cooling Speed) One Lead to Heat on TStat W (Hea.ng Speed) From Azure Motor

Connec.ng The Azure Digi- Motor X- 13 Mode Op.ons For Constant Fan Opera.on 1. Azure and X- 13 are controlled by 24VAC. If the OE had a tap for low speed constant fan, connect the orange speed tap 1 to this loca8on. 625 RPM would be controlled by thermostat. Or 2. Connect orange speed tap 1 to +24V. 625 RPM will be controlled by main power to HVAC system. Thermostat can be lee in AUTO mode; motor will run at 625 RPM 24/7 (unless there is a call for heat/cool). An external switch between orange speed tap 1 and +24V can be added.

Installa.on Complete System Decal