Lynx Delta Pressure Sensor Manual

Similar documents
Basic 3-Stage Control Applications & Reference. RJG, Inc. 2002, 2003, 2009

Experiment 6: Induction

ICL Three Pump Controller

CS 440RC. Solid De-icer Controller Operator Manual

Detailed Assembly Instructions. ATS Evacuated Tube - Solar Panel Units ATS10 / ATS20 / ATS30

Cavity Pressure Sensors Button Style Sensors Installation & Use Instructions

Sunbeam Alpine Series III, IV, and V Fuel & Temperature Gauges by Michael Hartman and Thomas Hayden Version 1.4 May 9, 2018

2003 Audi A4 testing

Installation Tips for your Remote Start system (for RS4LX>GMBP for GM vehicles)

BigStuff3 - GEN3. 1st Gear Spark Retard with Spark Retard Traction Control System (SR 2 ) Rev

Advanced Troubleshooting Guide Snorkel V Battery Charger Rev 0 3JAN07

Multi-Tank Submersible Pump Install Manual

TECHNICAL NOTE #4 Revised May 24, BOGART ENGINEERING Two Bar Road, Boulder Creek, CA (831)

PREVOST AIR SYSTEMS WHAT THEY DO AND HOW THEY DO IT

Motor-CAD End Winding Spray Cooling Model

Do isolate the power supply from other high power systems such as Stereos and Alarms

Engine Performance Troubleshooting Tree - Signature and ISX CM870

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

ROW PRO DOWN PRESSURE

Front Drive System - Big Block Chevy Installation Instructions Big Block Chevy with AC & with PS

Autonomously Controlled Front Loader Senior Project Proposal

& Tower for PWM Control. Maximum Application Rates with Two 5.3 GPM Electric Pumps

Volumetric Measuring Devices Issued: Revision Number: 2

ALL AMERICAN BILLET. Front Drive System - Small Block Ford Installation Instructions

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

Disco 3 Clock Spring / Rotary Coupler replacement

R & D SPECIALTIES ROTROL I USER'S MANUAL

Greddy E-manage Installation and Tuning Information

Carb2EFI Fuel System Conversion Kit Intank Fuel Pump (450 LPH Gasoline/E85 Compatible)

Asepsis 21 Delivery Unit

OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2017 RELIABILITY SCORECARD

Catalytic Failures. Engine running too hot.

MATRIS REPORT VOLVO CONSTRUCTION EQUIPMENT 11/20/ Volvo Remarketing. arnold. arnold. Building. Administrator

Familiarize yourself with the pressure loss phenomenon. The Discussion of this exercise covers the following point:

Procenter Delivery, Console Mounted on an Elevance Chair Installation Guide

LUBRICATION SYSTEM B-17 Technical Session for Flight Engineers 10/14/2017

Model: AEM14 Analog Engine Monitor

TROUBLESHOOTING TP. Index

Tri-Spark Ignition System Installation Triple Cylinder TRI-0001

Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.

STEP 1 STEP 2. Disconnect the negative terminal from both batteries.

TuffCam Swing Clamps C-1. Frequently Asked Questions

DOLI's STANDARD COMPRESSION FLEXOMETER (GOODRICH FLEXOMETER)

Draft Unofficial description of the UNRC charger menus

Experiment setup for thermocouple calibration

INSTRUMENTATION & CONTROL

Operating Instructions for Models Cobra and Lynx Air and Duct Leakage Testers: (Inlet Damper and Digital Gauges)

HEATEC TEC-NOTE. Portable fuel tanks. Volumes and Levels. Publication No Revised FIGURE 2. VOLUMES* (GALLONS)

Implement and Steering/Hydraulic System Testing and Adjusting

Instant Chat off the main page of Or simply call our tech team at

Bisnet Solutions for Tomorrow, Today! The Die Casting Process Planner. Users Manual. August 5, A Product By: Bisnet - 1 -

GPS AutoSteer System Installation Manual

AutoControl Pressure Governor

DSTP20: Fuel Transfer Pump

Can we use CAN bus data?

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

CF-10 Option Operating Instructions

Pressure Sensors for Test and Measurement. For Precise Pressure Measurement in Static and Dynamic Applications

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

VOLTAGE CONNECTOR CORCOM S VOLTAGE SELECTING AND FUSED CONNECTOR

Tracer VMA with AutoReg

F300 Pressure Regulator

KOBOLD DF-MA Flow Transmitter. User Instructions

GPS AutoSteer System Installation Manual

QUASAR FAQ What is the difference between Quasar and the Impulse system?

FRP SystemOne GELCOATER OPERATION MANUAL. MAGNUM VENUS PRODUCTS Operation Manual. Part No. M Revision

Problem Set 3 - Solutions

Instant Chat off the main page of Or simply call our tech team at

OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2018 RELIABILITY SCORECARD

This Document is property of Old New England Marine

INSTRUCTION MANUAL MODEL 213, 214, 215 and 216 POSITIVE DISPLACEMENT FLOWMETERS

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

Relay Driver Applications Guide

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

KOBOLD DAA FLOW INDICATOR. User Instructions. DAA_manual_12-13

Data Sheet. Motorized Test Stand w/pc Control ESM303

V PicoScope NVH Diagnostics Overview

Terminal Assembly Machine

ECT Display Driver Installation for AP2 Module

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

PCS HIGH-LOW TIMER CONTROLLER USER GUIDE PCS HIGH-LOW TIMER CONTROLLER. Contents. Calibrating the Transducer... 6

HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide

ASSEMBLY GUIDE. D-M-E Tubular Manifold & Components System

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

INSTALLATION MANUAL. BULLET PROOF VK Oil Cooler Kit F-SERIES

TECHNICAL DATA CAUTION

Kit. Hydraulic Kit Installation Guide REV A. Item Component Part Number Qty

INSTALLATION MANUAL. BULLET PROOF VK Oil Cooler Kit F-SERIES

Tracer VM with User Interface

77 FLASH CODE 77 - EXHAUST BACK PRESSURE FAULT AND SEVERAL INFORMATION CODES

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

Fluid Monitoring Station

Planting. Press to Highlight Configuration. Gauge Wheel Load Alarm. Value must be entered for your specific planter and parallel arm combination

Water Valve Shutoff. WVS Water Valve Shutoff

Model 2500 Horsepower Computer System User Manual

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

Overview of operation modes

Terex Calibration and Troubleshooting Manual

Transcription:

When Quality Counts Lynx Delta Pressure Sensor Installation and Applications RJG, Inc. 2009 Lynx Delta Pressure Sensor Manual Feb. 13, 2009

Lynx Delta Pressure Sensor What is Included in the Lynx Delta Pressure Sensor Kit? Delta Pressure Sensor CE-LX5-6M Lynx Cable Delta Pressure Sensor Manual When Quality Counts Lynx Delta Pressure Sensor Installation and Applications RJG, Inc. 2009 Lynx Delta Pressure Sensor Manual Feb. 13, 2009 2

Introduction Lynx Delta Pressure Sensor The Lynx is a machine or mold mount differential pressure sensor designed to be used with the edart System. It measures the difference in coolant pressure between the two NPT fittings. This provides information about the stability of the cooling that the mold provides to the parts (see Application Notes). No fluid flows through the device. Figure 1: Lynx Delta Pressure Sensor Specifications Maximum pressure at either port: 150 psi (10.3 bar). Maximum measurable difference: 100 psi (6.88 bar). Maximum Case Temperature: 140 F (60 C). Maximum Coolant Temperature: 180 F (82 C). Accuracy: 2% Zero: 0.1 % Pressure Input Connection: 1/4-18 NPT Lynx Connector: Microstyle DC connector 3

Hardware Installation Warning Make sure Coolant System is free from pressure Before attempting installation CAUTION Always power down equipment before working on 3.85 REF 3.38 1/4-18 NPT TYP Screw Size 10-24 x 1 3 4" Mold Inlet [High Pressure] RJG, Inc. Traverse City MI 49686 Delta Pressure Sensor Model: SN: XX305XXXXX Lynx Mold Outlet [Low Pressure] Max Pressure: 150 psi Full Scale: 100 psi Delta 1.42 2.50 REF Lynx Connector Output to edart 1.93 0.930 NOM Figure 2: Mounting hole dimensions IMPORTANT NOTES Exceeding 150PSI (10.3 bar) may result in damage to the device! This device is for H20 based coolants! This is not designed to measure hydraulic pressure! 4

Installation Checklist Mount Delta-P Transducer Choose location on the machine or mold to mount the (see Figure 2 for mounting hole dimensions). Avoid mold or machine surface temperature above 140 F (60 C). Do not mount on the ejection plate or any other surface subject to high impact or vibration. Also avoid material feed lines or any other source of static electricity Install T-fittings On the both inlet and outlet sides of the mold cooling water insert a T-fitting of sufficient size to allow the same flow through the original line (see Figure 3). Connect T-fittings to Delta-P device Connect the line from the inlet T to the + (or Hi ) side of the delta pressure sensor and connect the - (or Low ) side to the line from the outlet T. This connection will normally show positive values because the pressure at the inlet is higher than the outlet. These lines must be able to handle the pressure but can be smaller since they carry no water flow, only pressure. Connect Delta-P device to edart Using Lynx cabling, connect the sensor to either of the Lynx ports on the edart or to a junction box which goes to the edart. Figure 3: Installation flow diagram 5

SOFTWARE SETUP IMPORTANT NOTE The Lynx Delta Pressure sensor requires edart software version October 2003 or later. After you start a job on the edart the delta pressure sensor will automatically identify itself in the Sensor Locations tool. Under the Sensor Location column choose Location from the drop down. You may enter anything under the IDENT column. For example if a mold has cooling plumbed separately on the A and B sides you could have two delta pressure sensors identified as Across Mold and A and then Across Mold and B. (Sensor Location and IDENT columns). After you accept the setup for the delta pressure sensor the software will begin computing a summary value for it on every shot. The name will be Average Value, Coolant Delta Pr.. This will be available for Alarm Settings as well as the Cycle Values, Summary Graph and Statistics tools. Figure 3: Installation flow diagram Application Notes Once the software is up and taking Delta-P data you will observe that the value of Delta Pressure, Across Mold as probably a straight line on the cycle graph. It is unlikely that there will be much interest in it because we expect the pressure variation across the mold to have long term changes and not cyclical ones. Perhaps the pinching and un-pinching of a cooling line as the mold opens and closes would show up as a cyclic variation. 6

The real interest is in the average value for each cycle. You can use this to search for long term problems that affect cooling. Sudden changes in Average Value, Coolant Delta Pr. usually indicate a change in the plant-wide coolant delivery due to various machines starting and stopping their cooling flow. Scale buildup in mold cooling channels will show up as a steady increase in the value in over a long time. A flow regulator will block the changes caused by other equipment in the plant and show just the changes due to flow channel blockage. And if the coolant is not flowing at all the Average Value, Coolant Delta Pr. will be zero if the coolant is shut off at the inlet and will be system coolant pressure if there is a total block somewhere in the mold. In all these cases the changes represent a change in the cooling rate applied to the parts in the mold. Given that most thermolators are capable of holding a fairly constant coolant temperature the flow becomes a major variable in cooling. The Average Value, Coolant Delta Pr. is a simple and inexpensive way of detecting changes in that flow. Changes in cavity pressure can indicate changes in cooling but these are sometimes hard to find. We recommend that you set a warning around Average Value, Coolant Delta Pr. value. First get the mold running with the proper mold surface temperature in steady state with the process centered to make your best parts. Then in the Alarm Settings tool add a warning above and below after at least 20 good shots (or whatever you have the suggested values setting set to). It is best to use this for an indicator (light tree) output rather than sorting parts because it may be difficult to sort parts unless you have correlated changes in Average Value, Coolant Delta Pr. with actual part characteristics. So usually you will turn the indicator switch on and the sort switch off for each delta pressure row on the Alarm Settings tool. Then when the light tree shows yellow you can check the process before the mold temperature changes enough to make bad parts. You could also set a reject alarm (red light) for really bad delta pressure; i.e. if the coolant channels are blocked or the coolant is turned off entirely. The Delta Pressure value can also be used as a Reject alarm to indicate that the water is turned off or the sensor has not been plugged in correctly. If you disconnect the low end and watch the Average Value, Coolant Delta Pr. over several shots the pressure will be the same as if the sensor is plumbed in on one side and not the other or the flow through the mold is entirely blocked. Add a Reject Above alarm and set it to about 5 psi below this value. Then set a Reject Below level at about 3 psi. If the Average Value, Coolant Delta Pr. goes outside these limits then something in the cooling system is not functioning and the parts will probably go bad. 7