Digital Pressure Sensor SALIENT FEATURES IP 65 enclosure Hysteresis Adjustable Programmable Pressure unit Dual Digital & Voltage Outputs Wide measurement range 1~10 bar Model Number Legend 1 2 3 4 1. Series 2. Type V: Vacuum (0 ~ 1 bar) P: Positive (1 ~ 10 bar) C: Compound (1 ~ 1 bar) 3. Output N2: 2 NPN NO/NC Outputs P2: 2 PNP NO/NC Outputs N2V: 2 NPN NO/NC & 15V Analog Outputs P2V: 2 PNP NO/NC & 15V Analog Outputs 4. Connection 2M: 2m Cable M12J3: M12 Junction Connector with 0.3m extension Example: PP22M Series Positive Pressure Type 2 PNP NO/NC Outputs 2m Cable NOTE: Contact us for models not shown in catalogue. Connector cables are sold separately; look in CC series catalogue for the same (www.inno.sg/cc). 01
Product Highlights Type Models Pressure Type Pressure Port Type Rated Pressure Range Display Pressure Range Withstand Pressure Applicable Fluid Set Pressure Resolution Power Supply Current Consumption Connection Operating Mode Output Analog Voltage Output Display Output Indication Other Indication Protection Circuits Withstand Voltage Insulation Resistance Shock Resistance Vibration Resistance Ambient Temperature Ambient Humidity Protection Class Weight Material 2 NPN VN22M VN2M12J3 PN22M PN2M12J3 CN22M CN2M12J3 2 NPN + 15V VN2V2M PN2V2M CN2V2M 2 PNP VP22M VP2M12J3 PP22M PP2M12J3 CP22M CP2M12J3 2 PNP + 15V VP2V2M PP2V2M CP2V2M kpa Mpa kgf/cm2 bar psi inhg mmhg mmh2o Type Rating Hysterisis Repeatability Error Response time Prewired 2 meter cable Vacuum 10.0 ~ 101.3 kpa M12 Jn. Connector, 0.3m extension Prewired 2 meter cable Positive Gauge Pressure 1/8" NPT, M5 0.0 ~ 101.3 kpa 0.0 ~ 1000.0 kpa 100.0 ~ 1000.0 kpa 300 kpa 1500 kpa 300 kpa Note: Filter accessory supplied along with unit is to be used to ensure IP65 rating 1 Air, Non corrosive & Non flammable gas 12 to 24 ±10% < 55 ma at no load M12 Jn. Connector, 0.3m extension Hysterisis Mode; Window Mode NPN or PNP open collector output (depending on model) Prewired 2 meter cable Voltage: 24 ; Current: 80mA; Residual Voltage: 1V Hysterisis mode: Adjustable; Window mode: Fixed(3 digits) ±0.2% F.S, ±1 digit 2.5ms; Chatterproof Function: 24ms, 192ms, 768ms selections Output Voltage: 1~5V ±5% F.S; Linearity: ±1% F.S 3 1/2 digit Red LED 7 segment display (sampling 5/sec) Output 1: Green LED; Output 2: LED 7 user changeable pressure units, key lock indication, sleep mode indication Output Short Circuit Protection 1000 VAC (between lead and case) for 1 minute 50 MΩ min. ( at 500 ) between case and lead wire 100G, 3 times each in direction of X, Y and Z 1.5mm amplitude at 1050 Hz for 2 hours each in direction of X, Y and Z Operation: 0 ~ 50 C; Storage: 20 ~ 60 C (non freezing; non condensing) Operation: 30 ~ 85% RH; Storage: 35 ~ 85% RH (non condensing) IP 65 Cable type: approx. 110g; Junction Connector type: approx. 45g Housing: ABS; Front Case: PC; Cable: 5mm² Oilresistant PVC Compound 100.0 ~ 100.0 kpa 100.0 ~ 100.0 kpa 1 M12 Jn. Connector, 0.3m extension 02
Product Highlights Changeble Pressure Units The series has 8 user programmable pressure units. A p p r o p r i a t e stickers are provided along with the product. Dust & Splash proof The series sensor is IP65 rated and is completely dust proof and can withstand minor water splashes on the body and water spray on the front facia. Sensor Dimension Drawing Sensor Unit (all models) 31 31 36.5 Ordering Code: PA1 4.5 40 35.5 40 Ordering Code: PA2 Top Mounting Bracket Side Mounting Bracket Ordering Code: BT2 45.5 5 26.2 Ordering Code: BT1 37.1 Protective Cover Ordering Code: FPC1 42.4 7 25 4.2 12.9 4.2 13 20 5 6.1 42.4 47.4 Note: Brackets and panel adapters are not provided along with the sensor and are to be ordered separately. 03
Connection Cable 2 Digital Output M12 Junction Connector * NPN O/P1 PNP O/P1 NPN O/P1 PNP O/P1 Output Diagram 15V NPN O/P2 PNP O/P2 2 Digital Output + 1 Analog Voltage Output 2 NPN Output Type NPN O/P2 PNP O/P2 2 NPN + 15V Analog Voltage Output Type Note: * 2 PNP Output Type (1) : DC 10~30V (2) : Output 1 (3) : 0 V (4) : Output 2 : 15 V Voltage Output Connector Cable is not supplied along with unit 2 PNP + 15V Analog Voltage Output Type 1KΩ (15V analog output) 1KΩ (15V analog output) 04
Nomenclature Output 1 Indication Up/ Increase Button Setting Button Main Display (PV) Output 2 Indication Down/ Decrease Button Output Characteristics Digital Output Type Positive, Compound Pressure Vacuum Pressure Hysteresis Mode: Output hysteresis value can be preset. Normally Open Normally Close Normally Open Normally Close Window Comparator Mode: Within pressure setting range, pressure sensor output can be ON or OFF. Normally Open Normally Close Normally Open Normally Close NOTE: In case hysteresis is set at less than or equal to 2 digits, switch output may chatter if input pressure fluctuates near the set point. In Window Comparator mode, the hysteresis is fixed in 3 digits. Pressure value level settings, at least 6 digits. 05
Output Diagram Voltage Output Type Compound Pressure Vacuum Pressure Positive Pressure Pressure Range Type Vaccum Positive Compound Model V P C 1000 kpa 100.0 kpa 0 101.3 kpa Rated Pressure Range Setting Pressure Range 0.0 ~ 101.3 kpa 10.0 ~ 101.3 kpa 0 ~ 1000 kpa 100 ~ 1000 kpa 100 ~ 100 kpa 101 ~ 101 kpa Mounting and Adjustments Air Filter The air filter accessory is to be installed with the sensor as shown to ensure IP65 level protection. Inlet Port Blocking The sensor has two inlet pressure ports, select the one most convenient for installation The unused inlet port should be plugged using the bolt (screw) provided along with the product. Teflon tape is to be used on the thread to ensure a leak proof seal. 06
Mounting and Adjustments Bracket Mounting Panel mounting Mount the bracket to the body using two M3x5L mounting screws. Use M3 screw to secure the bracket to the mounting surface. Tightening torque should be between 0.5 0.7 Nm. Mounting bracket BT1 Front Protective Cover 36x36 ±0.3mm Mounting bracket BT2 Cat. No. 512 Exclusively Represented by: Intech Systems Chennai Pvt Ltd S2, Guindy Industrial Estate Chennai 600 032. Ph: 4353 8888 Email: info@intechchennai.com www.inno.sg INNO, Rights Reserved In the interest of continious product improvement 07