CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Similar documents
XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

Thermal flow sensor TFS-35

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

PMS - PKS / PMW - PKW series

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

Thermal flow sensor TFS-35

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Inductive Proximity Sensor

Inductive Proximity Sensor

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Electronic pressure switch with two switching outputs

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Inductive Proximity Sensor

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Surface mounting, flush mounting, and DIN track mounting

Electronic pressure switch with integrated analogue output

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

High-speed detection even a little liquid leak

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Cylindrical Inductive Proximity Sensor GX-M SERIES

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

HFS - High Frequency Limit Level Sensor

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Operating instructions Flow monitors SI5000 SI / / 2007

Safety Sensor CSS 180 Product Information

Industrial Power Supplies

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Level Limit Switch liquiphant FTL 360 / FTL 361

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Pressure transmitter for industrial applications Type MBS 4510

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Solid State Relays, 3-phase

Inductive Proximity Sensor E2Q2. Ordering Information. Limit Switch Style Proximity Sensor with 5-Position Sensing Head

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Model Pressure range ON/OFF output Linear output

Operating instructions Flow monitors SI / / 2010

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

optical sensors through-beam, retro-reflective, dif. reflection sensors 2300 visible red light robust metal housing

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Ultrasonic sensors OsiSense XX Cylindrical plastic case, M12 x 1, M18 x 1, M30 x 1.5 DC supply, solid-state output

Technical Data Measuring principle Thin-film-on-steel Media temperature -40 C C

C B. Operating up to 5000m altitude 5 year product warranty Models

General_technical_data Series

Open Frame Power Supplies

PHOTOELECTRIC S300 PA MAXI SENSORS APPLICATIONS.

OPTISWITCH 6500 C Technical Datasheet

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

OPTISWITCH 6500 C Technical Datasheet

Rectangular-shaped Inductive Proximity Sensor.

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Level Limit Switch liquiphant FTL 365 / FTL 366

Photoelectric Sensors OEM Prism Series

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co.

Pressure transmitters for industrial applications Type MBS 4510

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

ACTUATORS POSITION SENSOR

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Capacitive level sensors CLS 23

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Electronic Pressure Switches

Contactless Encoder with Stainless Steel Housing Incremental: ppr RI360P0-EQR24M0- INCRX2-H1181

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Flow measurement FlexFlow PF20H Hygienic flow sensor

Not affected by drops, bubbles or froth

55 Series - Miniature General Purpose Relays 5-10 A

Operating instructions Binary level sensor. LI214x /00 04/2016

Electronic Pressure Switches

General_technical_data Series

Short form catalogue. Motor protection & control

Differential Pressure Sensor

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

Series 230 Automatic Transfer Switch

H3DS-X - Solid State Two-Wire Timer

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

EX-F70 SERIES EX-F60 SERIES

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH Analog /Digital. Technical Data / Description

Transcription:

Capacitive sensor, Foreground Suppression Main features Compact housing Supply voltage: 10 to 30 VDC Output: 100 ma, NPN or PNP preset Make or break switching function LED indication for output and power ON Protection: reverse polarity, short circuit and transients Cable and pigtail M8 plug versions Excellent EMC performance IP65, IP66, IP67, IP68 and IP69K for hose-down applications culus Ecolab Description The CD34.. capacitive sensor is designed for detecting water-based (conductive liquids through a non-metallic container wall, and it automatically adapts to various thicknesses of plastic or glass walls. The universal mounting brackets allow the sensor to be fixed on various tubes or containers. Strong, compact housing with IP69K ratings and ECOLAB approval for wash-down applications. The sensor will function out of the box in most applications, and teach-in capabilities are available for adapting the sensor to more challenging applications. Main functions Detection of water-based fluids inside a container or tube without direct contact with the fluids. The sensor detects the liquids reliably while compensating for residue film, moisture or foam build-up from liquids such as water, milk, body fluids (blood, acid- or alkaline solutions with conductivity as high as 50 ms/cm inside or outside the container wall. Flexible and fast universal mounting bracket. The sensing principle detects only the level of the liquids while ignoring foam, film or build-up that would cause standard capacitive sensors to detect faultily. 1

References Product selection key CD34CNFLF Enter the code option instead of Code Option Description C - Capacitive sensor D - Rectangular housing 34 - Length of housing C - Plastic housing N - Neutral F - Flush mounting L - Liquid level F Foreground suppression N NPN P PNP O N.O. C N.C. P2 2 m PVC Cable T5 Pigtail PVC Type selection Connection Output NPN, N.O. NPN, N.C. Cable PNP, N.O. PNP, N.C. NPN, N.O. NPN, N.C. Pigtail PNP, N.O. PNP, N.C. Mounting bracket Code CD34CNFLFNOP2 CD34CNFLFNCP2 CD34CNFLFPOP2 CD34CNFLFPCP2 CD34CNFLFNOT5 CD34CNFLFNCT5 CD34CNFLFPOT5 CD34CNFLFPCT5 ACD34-MB01 2

Structure B A B A E E E D C C Fig. 1 Cable Fig. 2 Pigtail Fig. 3 Sensing surface Element Component Function A LED Green LED: Power ON B LED Yellow LED: Output C 2 M3 Fixing holes for sensor mounting D Sensing surface E Recessed area for cable strips, max. 5 mm wide Sensing Accuracy Temperature drift Detection Detection liquids Factory settings 20% (-25 C... +80 C Manual teach 20% (-25 C... +60 C Pipes diameter Min. Ø 8 mm Out of the box: Plastic 0.5-6 mm (non-conductive plastic wall wall thickness Glass 0.5-4 mm (non-conductive glass wall With manual setup: Up to 10 mm plastic wall (best case wall thickness Up to 10 mm glass wall (best case Water-based liquids such as water, milk, syrup, honey, milkshakes, lubricates, acids, alkaline fluids, body fluids and other high-conductive liquids (up to 50 ms 3

Features Power Supply Rated operational voltage (U B 10... 30 VDC (ripple included Ripple (U rpp 10% No load supply current (I o 13 ma Power-ON delay (t v < 300 ms Outputs Output functions Output switching function Rated operational current (I e OFF-state current(i r PNP and NPN Voltage drop (U d Protection Utilization category Load capacitance max at (U e NPN or PNP by sensor type N.O. and N.C by sensor type 100 ma 50 μa < 1.5 V Short circuit, reverse polarity and transients Control of resistive loads and DC-1 solid-state loads with optical isolation DC-13 Control of electromagnets 330 nf Operation diagram Tv = Power-ON delay power supply Target Break output (N.C. Make output (N.O. ON Present ON ON Tv Tv Response times Operating frequency (f Response times 10 Hz 50 ms OFF-ON (t ON 50 ms ON-OFF (t OFF 4

Indication Normal mode Green LED Yellow LED Power Output OFF OFF OFF OFF ON OFF ON OFF ON ON ON ON Output short circuit Green LED Yellow LED Output OFF Flashes 4Hz Yellow LED flashes minimum 1 sec. Teach by wire Out of the box (Factory settings: Typically, the sensor can be used without any additional calibration; it is designed to work with plastic tank walls of approximately 0,5 to 6 mm in thickness and glass walls of approximately 0,5 to 4 mm in thickness. It is important that the glass or plastic is nonconductive. Calibration: If the factory settings are insufficient, the sensor is teachable to either Full or Empty. Calibration Full: The sensor switch point is set below the actual detection value to ensure that slight changes in the application will not affect the sensing performance. In most applications, the full calibration on a full tank or tube will be sufficient. In critical applications with large variations in media type and temperature, it can be an advantage to teach the Full level with approximately 50 % of the active sensing surface covered. Full calibration procedure: Connect teach wire to V+ for 2-7 seconds The green LED flashes 1 imp. per sec. and the yellow LED is OFF After successful calibration, the yellow LED flashes 3 times (with 1 Hz Calibration Empty: The sensor switch point is set above the actual detection value to ensure that slight changes in the application will not affect the sensing performance. In most applications, the Empty calibration on an empty tank or tube will be sufficient. In critical applications with a high amount of residue film, moisture or foam build-up, an Empty calibration can be performed with the build-up present. Empty calibration procedure: Connect teach wire to V+ for 7-12 seconds The green LED flashes 1 imp. per sec. and the yellow LED is ON After successful calibration, the yellow LED flashes 3 times (with 1 Hz Cancel calibration procedure: Keep the teach wire connected to V+ for more than 14 seconds to abort teach procedure. The switch points will remain unchanged. The green LED is off and the yellow LED flashes (4 Hz 5

Green LED Yellow LED Output Flashes 1Hz OFF Full calibration (2-7 sec Flashes 1Hz ON Empty calibration (7-12 sec NA Flashes 3 times 1Hz Succesful "full calibration" NA Flashes 3 times 1Hz Succesful "empty calibration" NA Flashes 10 times 4Hz Unsuccesful calibration (cancelled or error (>12 sec Environmental Ambient temperature -25... +80 C (-13... +176 F Operating -40... +85 C (-40... +185 F Storage Ambient humidity range 35%... 100% Operating 35%... 100% Storage Vibration 10...150 Hz, 1.0 mm/15 g EN 60068-2-6 Shock 30 gn n / 11ms, 6 pos, 6 neg per axis EN60068-2-27 Drop test 2 x 1 m and 100 x 0.5 m EN 60068-2-31 Rated insulation voltage (U i 75 VDC Dielectric insulation voltage 1250 VAC rms 50/60 Hz for 1 min. Rated impulse withstand voltage 1 kv 1.2/50 µs Pollution degree 3 ICE60664, ICE60664A, EN60947-1 Overvoltage category III IEC60664; EN60947-1 Degree of protection IP65, IP66, IP67, IP68 @ 1.3m and 24 h IEC60539; EN60947-1 IP69K DIN 40050-9 NEMA Enclosure Types 1, 2, 4, 4x, 5, 12 NEMA 250 EMC Electrostatic discharge immunity test ± 8 kv @ air discharge or ± 4 kv @ contact discharge IEC 61000-4-2, EN60947-1 Electromagnetic field immunity 3 V/m IEC 61000-4-3, EN60947-1 Fast transient immunity 2 kv IEC 61000-4-4, EN60947-1 Wire-conducted noise 3 V IEC 61000-4-6, EN60947-1 Power frequency magnetic field immunity test 30 A/m IEC 61000-4-8, EN60947-1 6

Mechanics/electronics Connection Cable Pigtail 2 m, 4-wire 4 x 0.14 mm 2, Ø = 3.4 mm, PVC 0.3 m, M8, 4-pin, male Wiring 1BN 2WH I LOAD <100mA 4BK 3BU Fig. 4 PNP NO + - Teach-in 1BN 4BK I LOAD <100mA 2WH 3BU Fig. 5 NPN NO + - Teach-in 1BN 2WH I LOAD <100mA 4BK 3BU Fig. 6 PNP NC + - Teach-in 1BN 4BK I LOAD <100mA 2WH 3BU Fig. 7 NPN NC NOTE: White wire connected to GND (3BU wire when not in use + - Teach-in Colour code BN Brown WH White BK Black BU Blue Housing Body PC/PBT Mounting bracket PC/PBT Light guides Polyamid TR55, Transparent Pigtail Black TPU (Thermoplastic polyurethane, Stainless steel AISI 304 Dimensions 8 x 16 x 34 mm Weight 60 g Cable version 30 g Pigtail version Tightening torque, Sensor 0.2 Nm Tightening torque, Mounting bracket 0.2 Nm Screw size M3 (with lowered head 7

Dimensions (mm 16 8 34 1.1 3 16.3 10 3 3.6 10.5 52.85 10.5 73.85 6.6 3.2 Fig. 8 CD34 26 Fig. 9 Mounting bracket (ACD34-MB01 7.6 8

Compatibility and conformity Approvals and markings General reference Sensor designed according to EN60947-5-2 and EN60947-1 MTTF d 246 years @ 40 C (+104 F EN ISO 13849-1, SN 29500 CE-marking Approvals Other Approvals (UL508 + C22.2 Topax 56, Topaz AC1, Topaz MD3, Topaz CL1, Topactiv OKTO, P3-hypochloran Delivery contents and accessories Delivery contents Capacitive sensor: CD34CNFLF Mounting bracket: ACD34-MB01 2 x Foam pads 3 mm (for pipe mounting 2 x Adhesive pads 1 mm (for screwless surface mounting Quick installation guide Accessories COPYRIGHT 2017 Content subject to change. Download the PDF: www.productselection.net 9