WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Similar documents
Chapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)

SINGLE PHASE WIRING SPECIFICATIONS

THREE PHASE WIRING SPECIFICATIONS

CHAPTER 10 ELECTRICAL. Notes:

Spring Test 7 due 05/03/2013

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

90.2 Scope. The installation of electrical conductors, equipment and raceways for:

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Spring Test 10 due 05/11/2013

ELECTRICAL SAFETY-RELATED WORK PRACTICES

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

CAL/OSHA ELECTRICAL LOW VOLTAGE

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Photovoltaic Solar Plan Review

CHAPTER 10 ELECTRICAL

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

CHAPTER V RESIDENTIAL WIRING

FACT SHEET Standard: Electrical Safety

2016 Photovoltaic Solar System Plan Review List

ELECTRICAL. 60 Minutes

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

AVOIDING ELECTROCUTION HAZARDS

120-ELECTRICAL SAFETY PROGRAM

The following are specific provisions of 1910(a)(2) that could be seen in the LBM sector

Electrical Hazards in Construction

ELECTRICAL GROUNDING SAFETY PROGRAM

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

Permit for Charging Equipment Installation Electric Vehicle Supply Equipment (EVSE)

ELECTRICAL - GENERAL REQUIREMENTS SELF INSPECTION CHECKLIST

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

Overcurrent Protection (2014 NEC) (Homestudy)

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

2011 NEC Code Updates Part 3

ESSENTIAL SAFETY RESOURCES

Definitions. Exposed part. Live or energized part. De-energized part

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Inspector Training Workshops Module One Photovoltaic Labeling based on 2008 NEC

Unified requirements for systems with voltages above 1 kv up to 15 kv

TRANSMISSION SYSTEMS

WPS SERVICE MANUAL. Section 7 Clearances. 7-1 Basic Electric Clearances - Services Miscellaneous Clearances Antenna Clearances...

Electrical Safety Program

ES5 Security Theory/Regulations Answer Schedule

Overcurrent Protection According to the 2011 NEC

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Unrestricted. S.Mukhopadhyay

Metering and Service Installation:

ECET Distribution System Protection. Overcurrent Protection

Electrical Safety. Introduction

PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS

Definitions of and have been revised. a. automatic b. nonautomatic c. none of the above d. both a and b

Approved Contractor Construction e-guide Residential Commercial

WISCONSIN ELECTRICIANS

CONTINUING EDUCATION FOR OREGON ELECTRICIANS NEC Code Change Part 2 Course # Hours

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

Line Gard. Underwriters Laboratories (UL) Applicable Code Notation

PROTECTION OF THE BRANCH CIRCUIT

2014 NEC Changes (Homestudy)

Element C8.3 Installation, Use and Inspection of Electrical Systems

Fee $20 Course: NEC Changes 1 This course is valid for these credentials: Credential Description Cred Code Credit Hours

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

Service Requirements

2011 NEC Significant Changes Part 1 The following course will summarize many of the important changes to the NEC code.

Chapter 4 Utility Systems Electrical

SOLAR PV INSTALLATIONS

Surface Regulations and Policies

Electrical Safety. Recognizing & Controlling Hazards

Chapter 8 Interior Wiring and Lighting

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

Pretest Module 24 Three-phase Service Entrance

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

Service Requirements

2014 NEC Analysis Part 2

NEC 2014 Code Changes

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

2011 NEC Changes Part 2 (Homestudy) (Homestudy)

ES5. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

What is electricity? A form of energy that is carried through wires and is used to operate machines, lights, etc. PPT-SM-ES

2014 NEC Changes Part 1 (Homestudy)

Illinois State University. Electrical Safety Procedure

NEC REQUIREMENTS FOR GENERATORS

IN2 Enclosed Switches and Circuit Breakers

Optimizing Emergency Power Systems for Health Care Applications

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE

SECTION 300 OVERHEAD SERVICE

ARKANSAS ELECTRICIANS

OVERHEAD SERVICE. Items to consider

SECTION PANELBOARDS

GENERAL HOUSEKEEPING. 1. Are all aisles, passageways, stairways and stairwells kept clear of tools, hoses, and trash?

2014 NEC Changes Part 4

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Energized Electrical Work

BP-Husky Refinery Toledo, OH

Electrical Safety Program

Continued from Part 2 Rules

Wilkins Safety Group

Transcription:

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST Use & Identification of Grounded and Grounding Conductors YES NO N/A Grounded conductors are identifiable and distinguishable from all other conductors. Equipment grounding conductors are identifiable and distinguishable from all other conductors. No grounded conductor is attached to any terminal or lead so as to reverse designated polarity. No grounding terminal or grounding-type device on a receptacle, cord connector or attachment plug is used for anything other than grounding. Where there s more than one nominal voltage system in a building containing multi-wire branch circuits, each ungrounded conductor of a multi-wire branch circuit, where accessible, is identified by phase and system that s permanently posted at each branch circuit panel board. Receptacles & Cord Connectors YES NO N/A Receptacles installed on 15- and 20-ampere branch circuits are of the grounding type (except as permitted for replacement receptacles below.) Grounding-type receptacles are installed only on circuits of the voltage class and current for which they re rated (except as provided in Table S-4 and Table S-5 below). Contacts are effectively grounded on receptacles and cord connectors that have grounding contacts (*Except for receptacles properly mounted on portable and vehicle-mounted generators and properly installed replacement receptacles). Grounding contacts of receptacles and cord connectors are grounded by connection to the equipment grounding conductor of the circuit supplying the receptacle or cord connector. The branch circuit wiring method has an equipment grounding conductor that the grounding contacts of the receptacle or cord connector is connected to. Where a grounding means exists in the receptacle enclosure or a grounding conductor is installed, grounding-type receptacles are used and connected to the grounding means or conductor. Ground-fault circuit-interrupter protected receptacles are

provided where replacements are made at receptacle outlets that require protection. Where there is no grounding means in the receptacle enclosure, the installation meets one of the following provisions: A non-grounding-type receptacle may be replaced with another nongrounding-type receptacle; or A non-grounding-type receptacle may be replaced with a ground-fault circuit-interrupter-type of receptacle that s marked "No Equipment Ground" (an equipment grounding conductor may not be connected from the ground-fault circuit-interrupter-type receptacle to any outlet supplied from the ground-fault circuit-interrupter receptacle); or A non-grounding-type receptacle may be replaced with a grounding-type receptacle where supplied through a ground-fault circuit-interrupter as long as the replacement receptacle is marked "GFCI Protected" and "No Equipment Ground" (an equipment grounding conductor may not be connected to such grounding-type receptacles). Receptacles connected to circuits having different voltages, frequencies or types of current (ac or dc) on the same premises are designed so that the attachment plugs used on the circuits aren t interchangeable. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops have ground-fault circuitinterrupter protection for personnel. Any temporary wiring installations used during construction-like activities, including maintenance, remodeling or repairs, involving buildings, structures or equipment meet the following requirements: There s ground-fault circuit-interrupter protection on all 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets that aren t part of the permanent wiring of the building or structure that are used by workers. (*A cord connector on an extension cord set is considered to be a receptacle outlet if the cord set is used for temporary electric power; and cord sets and devices incorporating the required ground-fault circuit-interrupter that are connected to the receptacle closest to the source of power are acceptable forms of protection.) Receptacles other than 125 volt, single-phase, 15-, 20-, and 30- ampere receptacles that aren t part of the permanent wiring of the building or structure that are used by workers have groundfault circuit-interrupter protection. Where the ground-fault circuit-interrupter protection isn t

available for receptacles other than 125-volt, single-phase, 15-, 20-, and 30-ampere, you establish and implement an assured equipment grounding conductor program covering cord sets, receptacles that aren t a part of the building or structure, and equipment connected by cord and plug that are available for use or used by employees on those receptacles. This program meets the following requirements: There s a written description of the program, including the specific procedures adopted by the employer, available at the jobsite for inspection and copying by OSHA representatives and affected employees; and One or more competent person has been designated to implement the program. Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug (except fixed cord sets and receptacles which that aren t exposed to damage) are visually inspected before each day's use for external defects and indications of possible internal damage. Equipment found damaged or defective isn t used until repaired You perform the following tests on all cord sets and receptacles that aren t a part of the permanent wiring, and on cord- and plug-connected equipment that must be grounded: Equipment grounding conductors are tested for continuity and to verify that it s electrically continuous; Receptacles and attachment cap or plug are tested for correct attachment of the equipment grounding conductor and to verify that the grounding conductor is connected to its proper terminal. All of the above tests are performed: Before first use; Before equipment is returned to service following any repairs; Before equipment is used after any incident which can be reasonably suspected to have caused damage; and At least every 3 months (*6 months for fixed cord sets and receptacles that aren t exposed to damage). You don t allow employees to use any equipment that doesn t pass these tests. You keep written logs or test records listing: Each receptacle, cord set and cord- and plug-connected equipment that passed the test; and The last date it was tested or interval for which it was tested. You retain test records until they re replaced by more current

test records. You make test records available on the jobsite for inspection by OSHA representatives and any affected employee. Outlet devices have an ampere rating of no less than the load to be served. Lampholders connected to a branch circuit with a rating above 20 amps, are of the heavy-duty type (*Heavy-duty lamp-holders of the admedium type have a rating of at least 660 watts; and other types of lamp-holders have a rating of at least 750 watts.) Receptacle outlets meet the following requirements: The amp rating of single receptacles installed on an individual branch circuit is no less than the branch circuit s amp rating; Receptacles connected to a branch circuit supplying 2 or more receptacles or outlets don t supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4 below; and The receptacle ratings of receptacles connected to a branch circuit supplying 2 or more receptacles or outlets comply with Table S-5 below or, where larger than 50 amperes, the receptacle rating is no less than the branchcircuit rating. (*Receptacles of cord- and plug-connected arc welders have ampere ratings of no less than the minimum branch circuit conductor ampacity.) A receptacle outlet is installed wherever flexible cords with attachment plugs are used. Requirements for Outside Conductors, 600 Volts, Nominal or Less YES NO N/A Conductors on poles are separated by at least 305 mm (1.0 ft) where they re not placed on racks or brackets. Conductors supported on poles provide the following minimum horizontal climbing space: Power conductors below communication conductors: 762 mm (30 in.); Power conductors alone or above communication conductors: 300 volts or less: 610 mm (24 in.); and/or over 300 volts: 762 mm (30 in.); Communication conductors below power conductors: same as power conductors. Open conductors, open multi-conductor cables and service-drop conductors of not over 600 volts, nominal meet the minimum clearances listed in Table S-6 below. Service conductors installed as open conductors or multiconductor cable without an overall outer jacket have a clearance

of at least 914 mm (3.0 ft) from windows that are designed to be opened, doors, porches, balconies, ladders, stairs, fire escapes and similar locations. (*Conductors that run above the top level of a window may be less than 914 mm (3.0 ft) from the window) Overhead service conductors aren t installed beneath openings through which materials may be moved, or where they obstruct entrance to building openings. Overhead spans of open conductors and open multi-conductor cables have a vertical clearance of no less than 2.44 m (8.0 ft) above the roof surface. The vertical clearance above the roof level is maintained for a distance of at least 914 mm (3.0 ft) in all directions from the edge of the roof. Areas above a roof surface subject to pedestrian or vehicular traffic have acceptable vertical clearance from the roof surface. A reduction in clearance to 914 mm (3.0 ft) is okay where the voltage between conductors doesn t exceed 300 and the roof has a slope of 102 mm (4 in.) in 305 mm (12 in.) or greater. A reduction in clearance above only the overhanging portion of the roof to not less than 457 mm (18 in.) is okay where the voltage between conductors doesn t exceed 300 if: the conductors don t pass above the roof overhang for a distance of more than 1.83 m (6.0 ft), 1.22 m (4.0 ft) horizontally; and the conductors are terminated at a through-the-roof raceway or approved support. (*The requirement for maintaining a vertical clearance of 914 mm (3.0 ft) from the edge of the roof doesn t apply to the final conductor span, where the conductors are attached to the side of a building.) Lamps for outdoor lighting are located below all energized conductors, transformers, or other electric equipment. (*The equipment is controlled by a disconnecting means that can be locked in the open position; or there are adequate clearances or other safeguards in place for re-lamping operations.) Disconnecting Means YES NO N/A There s a means of disconnecting all conductors in a building or other structure from the service-entrance conductors. The service disconnecting means plainly indicate whether it s in the open or closed position. The disconnecting means is installed at a readily accessible location nearest the point of entrance of the service-entrance conductors. Each service disconnecting means simultaneously disconnects all ungrounded conductors.

Each service disconnecting means is suitable for the prevailing conditions. Services over 600 volts, nominal, meet the following additional requirements: Service-entrance conductors installed as open wires are guarded to make them accessible only to qualified persons. Signs warning of high voltage are posted where unqualified employees might come in contact with live parts. Overcurrent Protection YES NO N/A Overcurrent protection of circuits rated 600 volts, nominal, or less, meet all of the following requirements: Conductors and equipment are protected from overcurrent in accordance with their ability to safely conduct current. Except for motor running overload protection, overcurrent devices don t interrupt the continuity of the grounded conductor unless all conductors of the circuit are opened simultaneously. A disconnecting means is provided on the supply side of all fuses in circuits over 150 volts to ground and cartridge fuses in circuits of any voltage where accessible to other than qualified persons so that each individual circuit containing fuses can be independently disconnected from the source of power. (*Exceptions: A current-limiting device without a disconnecting means is okay on the supply side of the service disconnecting means; a single disconnecting means is okay on the supply side of more than one set of fuses as permitted by the exception for group operation of motors below; and a single disconnecting means is okay for fixed electric space-heating equipment.) Overcurrent devices are readily accessible to each employee or authorized building management personnel. Overcurrent devices aren t located where they re exposed to physical damage or in the vicinity of easily ignitable material. Fuses and circuit breakers are located or shielded so that employees won t be burned or injured by their operation. Handles or levers of circuit breakers, and similar parts that may move suddenly in such a way that persons in the vicinity are likely to be injured by being struck by them, are guarded or isolated.

Circuit breakers clearly indicate whether they re in the open (off) or closed (on) position. The up position of the handle is the closed (on) position on circuit breakers handles on switchboards that are operated vertically. Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits are listed and marked "SWD." A circuit breaker with a straight voltage rating is only installed in a circuit in which the nominal voltage between any 2 conductors doesn t exceed the circuit breakers voltage rating. Two-pole circuit breakers aren t used for protecting a 3- phase, corner-grounded delta circuit unless the circuit breaker is marked 1Φ -- 3Φ to indicate such suitability. Circuit breakers with a slash rating, such as 120/240 V or 480Y/277 V are only installed in a circuit where the nominal voltage of any conductor to ground doesn t exceed the lower of the 2 values of the circuit breakers voltage rating and the nominal voltage between any 2 conductors doesn t exceed the higher value of the circuit breakers voltage rating. Feeders and branch circuits over 600 volts, nominal, meet the following requirements: Feeder and branch-circuit conductors have overcurrent protection in each ungrounded conductor located at the point where the conductor receives its supply or at a location in the circuit determined under engineering supervision. Circuit breakers used for overcurrent protection of threephase circuits have at least 3 overcurrent relays operated from 3 current transformers. (*1:On three-phase, three-wire circuits, an overcurrent relay in the residual circuit of the current transformers may replace one of the phase relays. 2: An overcurrent relay, operated from a current transformer that links all phases of a three-phase, three-wire circuit, may replace the residual relay and one other phase-conductor current transformer. 3: Where the neutral isn t grounded on the load side of the circuit, the current transformer may link all three phase conductors and the grounded circuit conductor (neutral).) Fuses used for overcurrent protection, if any, are connected in series with each ungrounded conductor. Each protective device is capable of detecting and interrupting all values of current that can occur at its location beyond its trip setting or melting point.

The operating time of the protective device, the available shortcircuit current and the conductors used are coordinated to prevent damaging or dangerous temperatures in conductors or conductor insulation under short-circuit conditions. Feeders meet all of the following additional requirements: The continuous ampere rating of a fuse doesn t exceed 3 times the ampacity of the conductors; The long-time trip element setting of a breaker or the minimum trip setting of an electronically actuated fuse doesn t exceed 6 times the ampacity of the conductor (for fire pumps, conductors may be protected for short circuit only); and Conductors tapped to a feeder may be protected by the feeder overcurrent device where that overcurrent device also protects the tap conductor. Grounding Requirements Systems that supply premises wiring are grounded as follows: All 3-wire dc systems have their neutral conductor grounded; Two-wire dc systems operating at over 50 volts through 300 volts between conductors are grounded (*Unless they supply only industrial equipment in limited areas and are equipped with a ground detector; they re rectifier-derived from an appropriate ac system; or they re fire-alarm circuits having a maximum current of 0.030 amperes.) AC circuits of less than 50 volts are grounded if they re installed as overhead conductors outside of buildings or supplied by transformers and the transformer primary supply system is ungrounded or exceeds 150 volts to ground. A grounding electrode conductor is used for a grounded system to connect both the equipment grounding conductor and the grounded circuit conductor to the grounding electrode. Both the equipment grounding conductor and the grounding electrode conductor are connected to the grounded circuit conductor on the supply side of the service disconnecting means or on the supply side of the system disconnecting means or overcurrent devices if the system is separately derived. For an ungrounded service-supplied system, the equipment grounding conductor is connected to the grounding electrode conductor at the service equipment. For an ungrounded separately derived system, the equipment grounding conductor is connected to the grounding electrode YES NO N/A

conductor at, or ahead of, the system disconnecting means or overcurrent devices. The path to ground from circuits, equipment and enclosures is permanent, continuous and effective. Metal cable trays, metal raceways and metal enclosures for conductors are grounded (*Except for metal enclosures such as sleeves used to protect cable assemblies from physical damage which need not be grounded; and metal enclosures for conductors added to existing installations of open wire, knob-and-tube wiring and nonmetallic-sheathed cable which need not be grounded if runs are less than 7.62 meters (25.0 ft), are free from probable contact with ground, grounded metal, metal laths or other conductive materials and enclosures are guarded against employee contact.) Metal enclosures for service equipment are grounded. Frames of electric ranges, wall-mounted ovens, counter-mounted cooking units, clothes dryers and metal outlet or junction boxes that are part of the circuit for these appliances are grounded. The metal parts of the following nonelectrical equipment are grounded: Frames and tracks of electrically operated cranes and hoists. Frames of nonelectrically driven elevator cars to which electric conductors are attached. Hand-operated metal shifting ropes or cables of electric elevators. Metal partitions, grill work, and similar metal enclosures around equipment of over 750 volts between conductors. Electric equipment is grounded effectively, i.e., is secured to, and in electrical contact with, a metal rack or structure and the metal rack or structure is grounded by the proper method for the noncurrent-carrying metal parts of fixed equipment set out below: Metal car frames supported by metal hoisting cables attached to or running over metal sheaves or drums of grounded elevator machines are also considered effectively grounded. Equipment for installations made before April 16, 1981, is effectively grounded if it s secured to, and in metallic contact with, the grounded structural metal frame of a building. Systems and circuits of 1000 volts and over (high voltage) are properly grounded. Systems supplying portable or mobile high voltage equipment, other than substations installed on a temporary basis, are properly grounded, i.e., they meet the following requirements: The system has its neutral grounded through an impedance. (If a delta-connected high voltage system is

used to supply the equipment, a system neutral shall be derived.) Exposed noncurrent-carrying metal parts of portable and mobile equipment are connected by an equipment grounding conductor to the point at which the system neutral impedance is grounded. Ground-fault detection and relaying is provided to automatically de-energize any high voltage system component that develops a ground fault. The continuity of the equipment grounding conductor is continuously monitored so as to de-energize automatically the high voltage feeder to the portable equipment upon loss of continuity of the equipment grounding conductor. The grounding electrode to which the portable equipment system neutral impedance is connected is isolated from and separated in the ground by at least 6.1 m (20.0 ft) from any other system or equipment grounding electrode, and there s no direct connection between the grounding electrodes. All noncurrent-carrying metal parts of portable equipment and fixed equipment, including associated fences, housings, enclosures, and supporting structures, is grounded. (*Exceptions: Equipment guarded by location and isolated from the ground need not be grounded, and pole mounted distribution apparatus higher than 2.44 m (8.0 ft) above ground or grade level need not be grounded) Table S-4. -- Maximum Cord- and Plug-Connected Load to Receptacle Circuit rating (amperes) 15 or 20 20 30 Receptacle rating (amperes) 15 20 30 Maximum load (amperes) 12 16 24 Table S-5. -- Receptacle Ratings for Various Size Circuits Circuit rating (amperes) 15 20 30 Receptacle rating (amperes) Not over 15 15 or 20 30

40 50 40 or 50 50 Table S-6. -- Clearances from Ground Distance 3.05 m (10.0 ft) Installations built before August 13, 2007 Maximum voltage < 600 V Conditions Above finished grade or sidewalks, or from any platform or projection from which they might be reached. (If these areas are accessible to other than pedestrian traffic, then one of the other conditions applies). Installations built on or after August 13, 2007 Voltage to ground < 150 V Conditions Above finished grade or sidewalks, or from any platform or projection from which they might be reached. (If these areas are accessible to other than pedestrian traffic, then one of the other conditions applies.) 3.66 m (12.0 ft) < 600 V Over areas, other than public streets, alleys, roads, and driveways, subject to vehicular traffic other than truck traffic. < 300 V Over residential property and driveways. Over commercial areas subject to pedestrian traffic or to vehicular traffic other than truck traffic. (This category includes conditions covered under the 3.05-m (10.0-ft) category where the voltage exceeds 150 V.) 4.57 m (15.0 ft) < 600 V Over areas, other than public streets, 301 to 600 V Over residential property and

alleys, roads, and driveways, subject to truck traffic. driveways. Over commercial areas subject to pedestrian traffic or to vehicular traffic other than truck traffic. (This category includes conditions covered under the 3.05-m (10.0-ft) category where the voltage exceeds 300 V.) 5.49 m (18.0 ft) < 600 V Over public streets, alleys, roads, and driveways. < 600 V Over public streets, alleys, roads, and driveways. Over commercial areas subject to truck traffic. Other land traversed by vehicles, including land used for cultivating or grazing and forests and orchards.