polylam vertical baffle system Product data sheet durlum.us Your contact for North America

Similar documents
pinta SPORTSLINE V Service [1/5] Call our telephone hotline for advice on your individual

SAS International +44 (0) tubeline. tubular linear ceiling

OWAtecta. OWA metal ceilings. OWAtecta Metal ceilings

CLIMA CANAL HYBRID HEATING AND COOLING CLIMA CANAL. Compact floor recessed fancoil unit HEATING

Cavity Stop Socks & TCBs

Roof access hatch installation instructions

LimbusBarn & Fences Acoustic workplaces and floor screens

Heradesign fine Product Data & Certificates

Catalog Swirl diffuser DAL 358

Insulating cable tray

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

Heradesign superfine Product Data & Certificates

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Active Chilled Beams

Maximum protection and wearing comfort PLUS PLUS. Protective gloves DOXO DOXO. Pacil

architectural lighting RAIL Pendant RAIL Surface Mounted RAIL Wall

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Ventilation grilles for installation into walls, sills or rectangular

RAUWORKS SCREEN/PARTITION PRODUCT RANGE AND TECHNICAL INFORMATION. Construction Automotive Industry

ALPRO ALPRO. The hinge system for aluminium and steel doors

Active Chilled Beams

AXIAL FANS Axis / Tubo OPERATION MANUAL

Cleaning, Maintenance and Repair

architectural lighting midi RAIL

PE-HDXc pipes (physically cross-linked polyethylene pipes)

Hardware Friendly Options are available for plain panels 295 and 299, providing precut finished edge details for fixture openings (1 to 16 diameter)

About. filzfelt.com 1

Data sheet chainflex CF210.UL

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Perfetto. Concrete Collection

Fibreglass cable protection channels. OEC Product Catalogue

Surface Protective Systems

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

High Precision Filter Tubes. Spirally Wound Welded Wedge Wire Screens

Product advantages Mobile crane LTM 1160/2

Connection Accessories for small Burner Controls

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

KRONE - Profi Liner. Quantity: 2 Type: SDP 27 elp3-cs. Technical specification/description

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

QUICK-LOCK. A complete survey of all Quick-Lock ceiling systems

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

Ventilation grilles for installation into walls, sills or rectangular

GEZE Levolan 60 Setting new standards for manual sliding doors

Data sheet chainflex CFSOFT1

Electro-hydraulic crimping tools SD300-6M / SD400-6M. Art /M / /M. convincing solutions. Video /M Video /M

Plastic Diffusers & Grilles

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Telescopic slides. Customized solutions.

Ariv. Tambour door cupboards year. Made in the E.U. Manufactured to. Manufactured guarantee

Standard. Industrial Storage Technology

LED Twister II. User manual UK Version 1.0

AS/NZS 4801:2001 Occupational Health and Safety Management

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

Home Elevator. Planning Guide

INDEX. Chapter2. air master. Grilles and Registers

Important instructions

High-speed doors for modern parking systems EFA-SST PS

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

Operating Manual for FINE-SPRAY gun W 3/FZ-Duo

Operating and Installation Instructions

CATALOG. Multi-Point Locks And Accessories

Ceiling diffuser 4DE

Owner skit. Manuale per l installatore Installer s guide Installations- Anweisungen Notice installateur SL2380

POWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

Parts and characteristics

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

KLIMA Active Chilled Beams

Inclined Platform Lifts SUPRA & SUPRA LINEA

Ceiling impulse diffuser Model PIL

MANUAL Invisible 6 P/L RETAIL SYSTEMS USA AND CANADA

Stradaflair. Strada Trench Convectors. Strada Flat Panel Range. Strada Radiant Skirting. Strada Heated & Chilled Ceilings. Strada Electrical Products

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

WINDOW VENTILATION High quality, customisable, Surface Mounted and Glazed In options

Armon Edero. User manual

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

Cover: BioSpec MD - Bright White 15246, Ladybird Above: BioSpec SR - Sandrift 67203, Bright White 67246

VIDEO MOTORE TENSIONED

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Medial Thigh Support installation & user manual

LIGHT COLUMN PEDESTRIAN TECH BRIEF

Incorporating V2.0. Product spec >>> > Series NV - Non vision grilles

Description. Material. LED Chip. Mounting. Max Length. Environment. Certifications. Warranty. Dimming

Ceiling air diffuser INDULCLIP INDUDRALL KOMBICLIP

SECTION METAL LOCKERS

Designed to prevent condensation and energy losses

CFP-LED Contractor Select Flat Panel. Installation Instructions

Contents Cleaning Products Pages 3-6 Cleaning Tools Pages 7-12

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

TECHNICAL BOOK Sliding container RI-VISTA

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

Then all roads lead to LACONT!

Sarnafil TS E. Polymeric membrane for roof waterproofing. Product Description

Inclined Platform Lifts SUPRA & SUPRA LINEA

Data sheet chainflex CF270.UL.D

COMMERCIAL CONSTRUCTION MANUFACTURERS OF CORRUGATED STEEL DECKING PRODUCTS CELLULAR DECK ROOF DECK FLOOR DECK.

Transcription:

polylam Your contact for North America Product data sheet

1 1 End cap / end cover with F-lip Connection detail U-Carrier coming soon!

POLYLAM puts the architecture in the limelight. This modern vertical baffle system with acoustic properties offers varied designing options and can also be used in thermally-active building systems. The customer can choose the colour or get it printed in wood look to create individual ceiling configurations. Together with the linear OMEGA 60 lighting channel, it is possible to create completely new designs. The metal ceiling contributes directly to Green Building / LEED certification. durlum POLYLAM metal ceilings fall under the general Master Format section 09 50 00 ceilings. When perforated and with fleece, 09 51 Acoustical Metal Pan Ceilings is possible. surface POLYLAM elements can be made out of galvanized sheet steel or aluminium. The surfaces are white powder-coated, similar to RAL 9016. Other RAL colours, coloured surfaces or imprinted surfaces are available, e.g. in DUROPLAN W wood design. perforation and acoustics Metal panels are available perforated with black acoustic fleece or non-perforated. durlum offers RV L6 perforation and RG L15 perforation as standard. For other available perforations please see. The baffles may be designed with perforated sides as well as perforated underneath. Acoustical requirements will determine the number of baffles, their height and their width. Acoustic data sheets may be available upon request. Fire performance In accordance with ASTM E8 Flame Spread Index for steel is 5 or less and Smoke Developed Index for steel is 50 or less. green building dimensions Baffle width: Special requests: Baffle length: Baffle height: Special requests: 1 9/16, 15/ or 15/16 [0, 6 or 100 mm] 1 /16-15/16 [0-100 mm] 11 1/16 to 1-5 19/ [00 to 800 mm] 15/16 to 1 /16 [100 to 60 mm] 1 /16 to -7 1/ [0 to 800 mm] durlum metal panels contribute directly to LEED and other GREEN BUILDING certifications. Typically applicable credits under LEED v: Recycled Content post- & pre-consumer info VOC Emissions conformity with VOC requirements Acoustic Performance sound absorption with acoustic fleece Environmental Product Declaration available No substances as outlined in the US Living Building v. Red List are internationally used. Learn more: greenbuilding@ The module can be selected at random. The smallest module pitch is calculated by adding 1 1/ [50 mm] to the width of the baffle. SYSTEM details POLYLAM carrier rail a -7 1/8" [100mm] Threaded rod 1/" [M6] 1 5/"[5mm] 1 5/16"[,mm] 1 /16"[0mm] nut 1/ [M6] U 100 L-shaped primary carrier baffle security clip POLYLAM baffle baffle height min. " [50mm] width module spacing

perforations Standard Perforation RV-L6 Standard Perforation RG-L15 9/ [6,9mm] 5/ [mm] 7/ [5,50mm] 60 Hole diameter: / [.1 mm] Open area: 5.00 % Max. width of perforation: -9 5/8 [1 6 mm] Max. plate width: -7 1/8 [1 00 mm] 5/ [mm] 7/ [5,50mm] Hole diameter: / [.5 mm] Open area: 16.0 % Max. width of perforation: -8 / [11 mm] Max. plate width: -7 1/8 [100 mm] imprinted surface wood prints Duroplan W150 Beech Duroplan W190 Whitewashed oak Other graphics available upon request. Standard panel 1 9/16-15/16 [0-100 mm] max. 1 - /16 [60 mm]

Installation The carrier rails run perpendicular to the baffle s axis and can be mounted via the perforated angle as cross bracing or directly via threaded rods or Nonius suspension rods. Baffle lengths less than - 11 1/16 [1 500 mm] require two carrier rails. Baffles longer than -11 1/16 [1 500 mm] require an additional carrier rail, which is mounted in the centre. The upstand at the front of the baffle has a tab in the centre; this controls alignment of the baffle in its longitudinal direction or allows for an optional threaded connection. The non-attached ends of the baffle can be closed via an end cover. A profiled edge serves as the connection between carrier rail and baffle, that creates a secure and interlocking link. Depending on the load, it is possible to provide a security locking feature by using a retainer clip to connect the baffle with the carrier rail. The system is also available with single point suspension, particularly for bare concrete ceilings or for rooms with low suspension height. Please note Installation must be carried out by qualified and trained staff according to the instructions for installation. These are available as download at www.. technical standards The parts comply with DIN EN 196 as well as ASTM C65 and ASTM E16. Production complies with the TAIM and CISCA guidelines and the durlum works standards and is quality controlled by the TÜV according to ISO 9001:008 and ISO 1001:00. cleaning As standard, durlum ceiling panels are made with an electrostatic polyester powder coating, thus providing them with a long-term finish. The powder-coated surface should always be cleaned wearing clean gloves. First clean it with a soft, dry cloth. If dirt cannot be removed by this procedure, the cloth can also be moistened, with the addition of a ph-neutral cleaner [household detergent], if necessary. Contact of the powder coating with both alkaline and acid substances must be avoided. Metallic powder coatings show a particularly sensitive reaction. Due to the risk of a change in hue or effect, for metallic coatings a suitability test must be performed. More information: MANUFACTURER CONTACT durlum GmbH An der Wiese 5 79650 Schopfheim Germany Phone +9.76.905.0 info@ FORMGLAS SPECIALTY SOLUTIONS LTD. 181 Regina Road Vaughan, Ontario Canada LL 8M Toll Free +1.866.65.800 Main +1.16.65.800 durlum@formglas.com 5