Type Termination Cable Size Copper Aluminum 2 CP2C1-1/0 CP1/0C1-2/0 CP2/0C1-4/0 CP4/0C1 CP4/0A1. Cable 250kcmil CP250C3 CP250A3

Similar documents
CP 600V Cable Protectors

Special Purpose S P A WORLD OF CIRCUIT PROTECTION UNDER ONE ROOF

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

Motor Lead Pigtail or V-Stub Splice 5380 Series For 5/8 kv Non-Shielded and Shielded Feeder Cables (Tape, Wire or UniShield Cables)

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

Lithium-Ion Battery-Powered Tools

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination

DISTRIBUTION CONNECTORS SECTION DF COMPRESSION TERMINALS. Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs

SUBMERSIBLE SECONDARY CONNECTORS

3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief

Insulated Street and Highway Lighting Mechanical Connectors Insulated connectors for above-ground applications.

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

3M Cold Shrink Splice Kit QS-III 5536A

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

Our overhead products go above and beyond all others. QUICK REFERENCE. Overhead Connectors. & Covers. Overview

B T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2)

BURNDY Compression. TWO HOLE HYLUG CODE CONDUCTOR STANDARD BARREL (Continued) Fig. 1 Fig. 2 Fig. 3. Conductor

Connector System Guide Compression Connectors Grounding Connectors Tools for Industrial Electrical Applications

QUICKTERM TERMINATION KIT

Connector Installation Guide Compression and Mechanical Connectors

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Accepts BEKU type dies Up to 150 mm 2 Cu lug. The EP-50H was designed to accept dies for BEKU type mechanical tool widely used in European countries.

Homac. Underground Distribution. Pedestal Connectors and Covers. Aluminum Lay-In Pedestal Connectors

Heat-Shrinkable Tubing

Wind Energy Catalog Solutions for the Wind Industry

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

Heat-Shrinkable Tubing

Class H & K Fuse Holders - 250/600 Volt

HI-LINE UTILITY SUPPLY CO. Phone: Fax: WEJTAP TOOLS WEJTAP HOT STICK ACCESSORY KIT

INSULGRIP Plugs and Connectors

Power Distribution Blocks

Open-Style Power Distribution Blocks

DIE AND COLOR CODE INFORMATION -1 B ~ Fig. 1. Installation Tooling Stud Figure Mechanical Hvdraulic Wire ~ W8CVT (1) W8CVT (1)

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Cutting & Crimping Tools

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

up to 30A limited by conductor size Operating and storage temperature:

PRODUCTS FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

Non-insulated terminals : 8, 14, 22, 38, 60, 70, 80, 100, 150, 180, 200, 325 mm 2

Rigid/Aluminum Conduit Bodies, Gaskets and Covers

UL 98 Fusible Disconnect Switches

Aluminum Mechanical Lugs

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

...at Altech, of course!

600A Deadbreak Elbow. K656LR Elbow Connector (with Test Point) Features:

SECTION PANELBOARDS

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Jumpers & Load Pickup Tools

Cam-Lok Single Pole Connectors

Customer Requirements Downtown Secondary Network Service

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING NON-NETWORK SYSTEMS

Blocks and Holders. In-Line Watertight Fuseholders. Applications. Benefits. Features. Specifications. w w w. l i t t e l f u s e.

Fax: PO Box 100, 2222 Moore Rd. Jonesville, MI

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Covers for Cast Iron or Aluminum Device Boxes

North American Power Fuses

Compression Connectors

Corrosion Protection for Electrical Conduit and Fittings

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents

PRODUCT CATALOG

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Wire Termination Tools and Installation Kits Recommended Tools

Homac. Underground Distribution. Table of Contents

Underground Distribution

TYPE BILT DISCONNECT SWITCHES

Underground Distribution

Series 2, 3, 4, & 5 Aluminum - Accessories

Wind Power Solutions. Make Energy Renewable and Reliable!

T CLASS T FUSE BLOCKS

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

Series 1 Steel - Accessories

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

IN-LINE WATERTIGHT FUSE HOLDERS

HP20 Series. Utilizes a Small #20 Size Shell Accommodates Up to 646 MCM Cable Patents Pending

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

Battery Operated Compression Tool

Open-Style Power Distribution Blocks

Phone: Fax:

Sta-Kon s Long Barrel Design

DuraGard Waterproof Connections

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Termination Products. Installing Kits. Recommended Tools. Plier-Type Tools Used for installation of various Sta-Kon terminal series

QO and HOMELINE Circuit Breaker Load Centers and Enclosures

DISTRIBUTION CONNECTORS

Single pole connectors

Kcmil. Mass kg/each. Tel:

A powerful way to manage your power distribution challenges. I Power Distribution Blocks

Heavy Duty Safety Switches

PRODUCT CATALOG Electrical components and enclosure accessories. Get familiar with Ouneva products online:

Transcription:

C 600V rotectors ECIL UROE Description # for Type Type Termination ize Copper luminum 2 C2C1-1/0 C1/0C1-2/0 C2/0C1-4/0 C4/0C1 C4/01 250kcmil C250C1 C2501 1 to 350kcmil C350C1 C3501 400kcmil C400C1-500kcmil C500C1 C5001 600kcmil C600C1 C6001 750kcmil C750C1 C7501 Mersen C rotectors are 1000kcmil C1000C1-2 C2C3 - special purpose limiters which are crimped or bolted to cables 1/0 2/0 C1/0C3 C2/0C3 - - 4/0 C4/0C3 C4/03 or terminals to clear and isolate 250kcmil C250C3 C2503 faults quickly, increasing the 3 to 350kcmil C350C3 C3503 reliability of service entrance Offset Bus 400kcmil C400C3-500kcmil C500C3 C5003 and distribution runs. C 600kcmil C600C3 C6003 rotectors have a 200,000 750kcmil C750C3 C7503 interrupting rating, yet will carry low cable overloads which are 1000kcmil 2/0 C1000C3 C2/0C5 - C2/0C5 4/0 C4/0C5 C4/0C5 handled by standard protective traight 250kcmil C250C5 C250C5 devices. protectors are 5 Bus to 350kcmil C350C5 C350C5 rated in terms of cable size and Offset Bus 500kcmil C500C5 C500C5 material (l or Cu). Heavier 600kcmil C600C5 C600C5 750kcmil C750C5 C750C5 duty CH cable protectors are available on special order. Heat 4/0 250kcmil C4/0C6 C250C6 C4/06 C2506 Mole 350kcmil C350C6 C3506 shrinkable (H) tubing can be 6 to 400kcmil C400C6 - specified for field installation. 500kcmil C500C6 C5006 TI blown fuse trigger indicators may be available upon request. 750kcmil 4/0 C750C6 C4/0C8 C7506 C4/0C8 Refer to the application Mole 250kcmil C250C8 C250C8 8 to 350kcmil C350C8 C350C8 information section for more information. 750kcmil Offset Bus 500kcmil C750C8 C500C8 C750C8 C500C8 *lease consult factory for special terminations. RTING: izes: #2 to 1000kcmil aluminum or copper Volts: 600VC IR: 200k I.R. C FETURE/BENEFIT: Fiberglass bodies for dimensional stability in harsh environments number stamped into terminal for permanent identification Crimp terminals for aluminum cable include oxide inhibitor Molded rubber boots or heat shrinkable tubing available for insulation and protection Current limiting device ermitted by National Electrical Code ROVL: UL listed to File E305297 Numbering ystem tandard Duty Heavy Duty Conductor ize Material: Copper or luminum C Termination Heat hrink Trigger Indicator C CH H TI C 500 C 3 - TI 26 E.MEREN.COM 2018 Mersen. ll rights reserved. Mersen reserves the right to change, update, or correct, without notice, any information contained in this datasheet.

ECIL UROE C 600V rotectors TYE C1 (CBLE TO CBLE - COER) * ize B D E J N C2C1 #2 7.12 (180) 1.44 (37).42 (11) 1.75 (44) 3.62 (92).31 (7.9) C1/0C1 1/0 7.12 (180) 1.44 (37).52 (13) 1.75 (44) 3.62 (92).39 (9.9) C2/0C1 2/0 7.12 (180) 1.44 (37).56 (14) 1.75 (44) 3.62 (92).44 (11) C4/0C1 4/0 7.12 (180) 1.44 (37).68 (17) 1.75 (44) 3.62 (92).55 (14) C250C1 250kcmil 7.38 (188) 1.44 (37).75 (19) 1.88 (48) 3.62 (92).62 (16) C350C1 350kcmil 7.62 (194) 1.62 (41).88 (22) 2.00 (51) 3.62 (92).71 (18) C400C1 400kcmil 7.62 (194) 1.62 (41).94 (.24) 2.00 (51) 3.62 (92).75 (19) C500C1 500kcmil 9.38 (238) 1.88 (48) 1.05 (27) 2.88 (73) 3.62 (92).85 (22) C600C1 600kcml 9.51 (242) 2.50 (64) 1.07 (27) 2.88 (73) 3.75 (95).94 (24) C750C1 750kcmil 9.51 (242) 2.50 (64) 1.32 (34) 2.88 (73) 3.75 (95) 1.06 (27) C1000C1 1000kcmil 10.00 (254) 3.00 (76) 1.50 (38) 3.13 (79) 3.75 (95) 1.16 (29) Type C1 Type C3 TYE C3 (CBLE TO OFFET BU - COER) * ize B D E I J L N R C2C3 #2 8.87 (225) 1.44 (37) 1.12 (28) 1.75 (44) 3.50 (88.9) 3.62 (92).96 (24).31 (7.9).42 (11) C1/0C3 1/0 8.87 (225) 1.44 (37) 1.12 (28) 1.75 (44) 3.50 (88.9) 3.62 (92).96 (24).39 (9.9).52 (13) C2/0C3 2/0 8.87 (225) 1.44 (37) 1.12 (28) 1.75 (44) 3.50 (88.9) 3.62 (92).96 (24).44 (11).56 (14) C4/0C3 4/0 8.87 (225) 1.44 (37) 1.12 (28) 1.75 (44) 3.50 (88.9) 3.62 (92).96 (24).55 (14).68 (17) C250C3 250kcmil 9.00 (229) 1.44 (37) 1.12 (28) 1.88 (48) 3.50 (88.9) 3.62 (92).96 (24).62 (16).75 (19) C350C3 350kcmil 9.12 (232) 1.62 (41) 1.12 (28) 2.00 (51) 3.50 (88.9) 3.62 (92).96 (24).71 (18).88 (22) C400C3 400kcmil 9.12 (232) 1.62 (41) 1.12 (28) 2.00 (51) 3.50 (88.9) 3.62 (92).96 (24).75 (19).88 (22) C500C3 500kcmil 10.00 (254) 1.88 (48) 1.62 (41) 2.88 (73) 3.50 (88.9) 3.62 (92) 1.19 (30).85 (22) 1.05 (27) C600C3 600kcmil 10.13 (257) 2.50 (64) 2.00 (51) 2.88 (73) 3.50 (88.9) 3.75 (95) 1.31 (33).94 (24) 1.07 (27) C750C3 750kcmil 10.13 (257) 2.50 (64) 2.00 (51) 2.88 (73) 3.50 (88.9) 3.75 (95) 1.31 (33) 1.06 (27) 1.32 (34) C1000C3 1000kcmil 10.63 (270) 3.00 (76) 2.00 (51) 3.13 (79) 3.75 (95) 3.75 (95) 1.56 (40) 1.16 (29) 1.50 (38) TYE C5 (TRIGHT BU TO OFFET BU - COER) ize B D J L M C4/0C5 4/0 10.37 (263) 1.44 (37) 1.12 (28) 3.62 (92).96 (24) 1.12 (28) C250C5 250kcmil 10.37 (263) 1.44 (37) 1.12 (28) 3.62 (92).96 (24) 1.12 (28) C350C5 350kcmil 10.37 (263) 1.62 (41) 1.12 (28) 3.62 (92).96 (24) 1.12 (28) C400C5 400kcmil 10.37 (263) 1.62 (41) 1.12 (28) 3.62 (92).96 (24) 1.12 (28) C500C5 500kcmil 10.37 (263) 1.88 (48) 1.62 (41) 3.62 (92) 1.19 (30) 1.50 (38) C600C5 600kcmil 10.50 (267) 2.50 (64) 2.00 (51) 3.75 (95) 1.31 (33) 2.00 (51) C750C5 750kcmil 10.50 (267) 2.50 (64) 2.00 (51) 3.75 (95) 1.31 (33) 2.00 (51) CBLE TYE * kcmil = MCM Type C5 TYE 1 TYE 2 TYE 3 TYE 5 TYE 6 TYE 7 TYE 8 E.MEREN.COM 27

C 600V rotectors ECIL UROE TYE C6 (MOLE TO CBLE - COER) * ize B E J M N R C4/0C6 4/0 7.87 (200) 1.44 (37) 1.75 (44) 3.62 (92) 2.50 (64).55 (14).52 (13).68 (17) C250C6 250kcmil 8.00 (203) 1.44 (37) 1.88 (48) 3.62 (92) 2.50 (64).62 (16).58 (14).75 (19) C350C6 350kcmil 8.12 (206) 1.62 (41) 2.00 (51) 3.62 (92) 2.50 64).71 (18).68 (17).88 (22) C500C6 500kcmil 9.38 (238) 1.88 (48) 2.88 (73) 3.62 (92) 2.88 (73).85 (22).81 (21) 1.05 (27) C750C6 750kcmil 9.51 (427) 2.50 (64) 2.88 (73) 3.75 (95) 2.88 (73) 1.06 (27) 1.00 (25) 1.32 (34) TYE C8 (MOLE TO OFFET BU - COER) * ize Type C6 B D J L M N C4/0C8 4/0 9.62 (244) 1.44 (37) 1.12 (28) 3.62 (92).96 (24) 2.50 (64).52 (14) C250C8 250kcmil 9.62 (244) 1.44 (37) 1.12 (28) 3.62 (92).96 (24) 2.50 (64).58 (13) C350C8 350kcmil 9.62 (244) 1.62 (41) 1.12 (28) 3.62 (92).96 (24) 2.50 (64).68 (17) C500C8 500kcmil 10.00 (254) 1.88 (48) 1.62 (41) 3.62 (92) 1.19 (30) 2.88 (73).81 (21) C750C8 750kcmil 10.13 (257) 2.50 (64) 2.00 (51) 3.75 (95) 1.31 (33) 2.88 (73) 1.00 (25) Type C8 * kcmil = MCM 28 E.MEREN.COM

ECIL UROE C 600V rotectors TYE 1 (CBLE TO CBLE - LUMINUM) * ize B J N Q R C4/01 4/0 13.88 353) 1.44 (37) 3.62 (92).55 (14) 2.50 (64).85 (22) C2501 250kcmil 13.88 (353) 1.44 (37) 3.62 (92).59 (15) 2.50 (64).94 (24) C3501 350kcmil 13.88 (353) 1.62 (41) 3.62 (92).71 (18) 2.50 (64) 1.13 (29) C5001 500kcmil 15.38 (391) 1.88 (48) 3.62 (92).85 (22) 2.88 (73) 1.33 (34) C7501 750kcmil 15.50 (394) 2.50 (64) 3.75 (95) 1.06 (27) 2.88 (73) 1.62 (41) Type 1 Typical Terminal ssembly Details TYE 3 (CBLE TO OFFET BU - LUMINUM) * ize B D J L N Q R C4/03 4/0 12.25(311) 1.44 (37) 1.12 (28) 3.62 (92).96 (24).55 (14) 2.50 (64).85 (22) C2503 250kcmil 12.25 (311) 1.44 (37) 1.12 (28) 3.62 (92).96 (24).59 (15) 2.50 (64).94 (24) C3503 350kcmil 12.25 (311) 1.62 (41) 1.12 (28) 3.62 (92).96 (24).71 (18) 2.50 (64) 1.13 (29) C5003 500kcmil 13.00 (330) 1.88 (48) 1.62 (41) 3.62 (92) 1.19 (30).85 (22) 2.88 (73) 1.33 (34) C7503 750kcmil 13.12 (333) 2.50 (64) 2.00 (51) 3.75 (95) 1.31 (33) 1.06 (27) 2.88 (73) 1.62 (41) Type 3 TYE 6 (MOLE TO CBLE - LUMINUM) * Number ize B E J N Q R C4/06 4/0 11.25 (286) 1.44 (37) 2.50 (64) 3.62 (92).55 (14).52 (13) 2.50 (64).85 (22) C2506 250kcmil 11.25 (286) 1.44 (37) 2.50 (64) 3.62 (92).59 (15).58 (14) 2.50 (64).94 (24) C3506 350kcmil 11.25 (286) 1.62 (41) 2.50 (64) 3.62 (92).71 (18).68 (17) 2.50 (64) 1.13 (29) C5006 500kcmil 12.38 (314) 1.88 (48) 2.88 (73) 3.62 (92).85 (22).81 (21) 2.88 (73) 1.33 (34) C7506 750kcmil 12.50 (318) 2.50 (64) 2.88 (73) 3.75 (95) 1.06 (27) 1.00 (25) 2.88 (73) 1.59 (41) Type 5 Use Copper rotectors Type C5 Type 6 Type 8 Use Copper rotectors Type C8 * kcmil = MCM Note: Inside surface of sleeve ends is coated with oxide inhibitor and capped. E.MEREN.COM 29

C 600V rotectors ECIL UROE COER CBLE ROTECTOR WITH HET HRINKBLE TUBING* TYE C1, COER CBLE rotector ize Inches (mm) With Heat hrinkable Tubing 4/0 7.12 (180) C4/0C1-H 250kcmil 7.38 (188) C250C1-H 350kcmil 7.62 (194) C350C1-H 500kcmil 9.38 (238) C500C1-H 750kcmil 9.51 (242) C750C1-H TYE C3, COER CBLE rotector With Heat ize Inches (mm) hrinkable Tubing 4/0 8.87 (225) C4/0C3-H 250kcmil 9.00 (229) C250C3-H 350kcmil 9.12 (232) C350C3-H 500kcmil 10.00 (254) C500C3-H 750kcmil 10.13 (257) C750C3-H TYE C5, COER CBLE rotector ith Heat ize Inches (mm) hrinkable Tubing 4/0 10.37 (263) C4/0C5-H 250kcmil 10.37 (263) C250C5-H 350kcmil 10.37 (263) C350C5-H 500kcmil 10.37 (263) C500C5-H 750kcmil 10.50 (267) C750C5-H TYE C6, COER CBLE rotector ize Inches (mm) With Heat hrinkable Tubing 4/0 7.87 (200) C4/0C6-H 250kcmil 8.00 (203) C250C6-H 350kcmil 8.12 (206) C350C6-H 500kcmil 9.38 (238) C500C6-H 750kcmil 9.51 (242) C750C6-H TYE C8, COER CBLE rotector ize Inches (mm) With Heat hrinkable Tubing 4/0 9.62 (244) C4/0C8-H 250kcmil 9.62 (244) C250C8-H 350kcmil 9.62 (244) C350C8-H 500kcmil 10.00 (254) C500C8-H 750kcmil 10.13 (257) C750C8-H * Transparent heat shrinkable tubing is supplied separately with -H Maximum curing conditions: 5 seconds at 450 F. 30 E.MEREN.COM

ECIL UROE C 600V rotectors LUMINUM CBLE ROTECTOR WITH HET HRINKBLE TUBING* TYE 1, LUMINUM CBLE rotector ize Inches (mm) With Heat hrinkable Tubing 4/0 13.88 (353) C4/01-H 250kcmil 13.88 (353) C2501-H 350kcmil 13.88 (353) C3501-H 500kcmil 15.38 (391) C5001-H 750kcmil 15.50 (394) C7501-H TYE 3, LUMINUM CBLE rotector ize Inches (mm) With Heat hrinkable Tubing 250kcmil 12.25 (311) C2503-H 350kcmil 12.25 (311) C3503-H 4/0 12.25 (311) C4/03-H 500kcmil 13.00 (330) C5003-H 750kcmil 13.12 (333) C7503-H TYE 6, LUMINUM CBLE rotector ize Inches (mm) With Heat hrinkable Tubing 4/0 11.25 (286) C4/06-H 250kcmil 11.25 (286) C2506-H 350kcmil 11.25 (286) C3506-H 500kcmil 12.38 (314) C5006-H 750kcmil 12.50 (318) C7506-H Type 5 Use Copper rotectors Type C5 Type 8 Use Copper rotectors Type C8 * Transparent heat shrinkable tubing is supplied separately with -H Numbers. Maximum curing conditions: 5 seconds at 450 F. MOLDED RUBBER INULTING LEEVE** FOR TYE C1 COER CBLE ROTECTOR ize B C D E F G 4/0CCR 4/0 10.44 3.69 3.38.83 1.33 1.50 2.00 (265) (94) (86) (21) (33) (38) (51) 500CCR 500kcmil 14.19 3.69 5.25 1.31 1.81 1.94 2.44 (360) (94) (133) (33) (46) (49) (62) FOR TYE C3 COER CBLE ROTECTOR ize B C D E F G 4/0CBR 4/0 7.06 3.69 3.38.83 1.33 1.50 2.00 (179) (94) (86) (21) (33) (38) (51) 500CBR 500kcmil 8.94 3.69 5.25 1.31 1.81 1.94 2.44 (227) (94) (133) (33) (46) (49) (62) ** Molded rubber insulating sleeves are ordered by their own catalog numbers, and not as suffixes to the cable protector catalog numbers. Neoprene coated except as noted. E.MEREN.COM 31

C 600V rotectors ECIL UROE Mersen rotectors have standard commercial splicing sleeve dimensions. ny crimping tool suitable for standard splicing sleeves, can be used. Follow crimping tool manufacturers instructions. ome crimping tool examples are shown below. It is recommended to use at least 2 crimps. CBLE ROTECTOR LICING LEVE ize Copper luminum (MCM or ID OD ID OD #2 0.31 (7.87) 0.42 (10.69) - - 1/0 0.39 (9.91) 0.52 (13.21) - - 2/0 0.44 (11.18) 0.56 (14.22) - - 4/0 0.55 (13.97) 0.68 (17.27) 0.54 (13.8) 0.84 (21.5) 250 0.62 (15.75) 0.75 (19.05) 0.59 (15.1) 0.94 (23.7) 350 0.71 (18.03) 0.88 (22.35) 0.71 (18.0) 1.13 (28.7) 400 0.75 (19.05) 0.94 (23.88) - - 500 0.82 (20.83) 1.05 (26.67) 0.84 (21. 2) 1.31 (33.3) 600 0.94 (23.88) 1.07 (27.18) 0.92 (23.4) 1.44 (36.6) 750 1.06 (26.92) 1.32 (33.53) 1.03 (26.2) 1.59 (40.4) 1000 1.16 (29.46) 1.50 (38.1) - - NDUIT - COER ize (MCM or CT-920, CT-920CH, CT-930, CT-930CH, CT-2920 Die Die Color & Die #2 CD-920-2 Brown 33 1/0 CD-920-1/0 ink 42 2/0 CD-920-2/0 Black 45 4/0 CD-920-4/0 urple 54 250 CD-920-250* Yellow 62 350 CD-920-350 Red 71 400 CD-920-400 Blue 76 500 CD-920-500 Brown 87 600 CD-920-600 Green 94 750 CD-920-750 Black 106 NDUIT - LUMINUM ize (MCM or CT-920, CT-920CH, CT-930, CT-930CH, CT-2920 Die Die Color & Die #2 CD-920-1/0 ink 42 1/0 CD-920-3/0** Tan 50 (Orange 50) 2/0 CD-920-4/0 Olive 54 (urple 54) 4/0 CD-920-300 White 66 250 CD-920-350 Red 71 350 CD-920-500 Brown 87 400 CD-920-600 Green 94 500 CD-920-500 ink 99 600 CD-920-750 Black 106 750 - - Note: Crimp Tools CT 2940 and CT940H may be used with adapter CD-940-D * Copper Tap Connector art Nos: HTCT250-8, HTCT250-2, HTCT250-250 * Tap Connector Die art No: CD-930H-250 ** luminum Tap Connector art No: HT2-8-L (NDUIT Die Color & Die No) 32 E.MEREN.COM

ECIL UROE C 600V rotectors THOM & BETT - COER ize (MCM or 13642M (13400) Hydraulic Head TBM14 (14 TON) Head TBM15 (15 TON) Head Head Die Cat Die Code Die Cat Die Code Die Cat Die Code Die Cat Die Code #2 11735 33 15528 33 15528 33 11402 33 1/0 11737 42 15508 42 15508 42 11334 42 2/0 11738 45 15526 45 15526 45 11405 45 4/0 11740 54 15511 54 15511 54H 11407 54H 250 11771 62 15510-CK 62 15510-CK 62 297-31669-7 62 350 11743 71H 15514-CK 71H 15514-CK 71H 11363 71 400 11744 76H 15512 76H 15512 76H 11410 76 500 11746-TB 87H 15506 87H 15506 87H 11423 87 600 11748 99H 15536-CK 94H 15536-CK 94H 11364 94 750 - - 15515-CK 106H 15515-CK 106H 74506 106 1000 - - 15603 125H 11416 125 THOM & BETT - LUMINUM ize (MCM or 13642M (13400) Hydraulic Head TBM14 Head TBM15 Head 21940 (40 TON) Head Die Cat Die Code Die Cat Die Code Die Cat Die Code Die Cat Die Code 4/0 11742 66H 15534 66H 15534 66H 11409 66 250 11744 76H 15512 76H 15512 76H 11410 76 350 11747 94H 15536-CK 94H 15536-CK 94H 11364 94 400 - - - - - - - - 500 11749 106H 15515-CK 106H 15515-CK 106H 74506 106 600 11751 112H 15504 115H 15609 112H 11426 112 750 - - - - 15602 140H 11418 140 BURNDY - COER BURNDY - LUMINUM ize (MCM or Burndy Hypress and Die et ize Burndy Hypress and Die et Y35 Y39 Y750 Y46* (MCM or Y35 Y39 #2 U2CRT U2CRT U2CRT U2CRT #2 - - 1/0 U25RT U25RT U25RT U25RT 1/0 - - 2/0 U26RT U26RT U26RT U26RT 2/0 U26RT U26RT 4/0 U28RT U28RT U28RT U28RT 4/0 U28RT U28RT 250 U29RT U29RT U29RT U29RT 250 U29RT U29RT 350 U31RT U31RT U31RT U31RT 350 U31RT U31RT 400 U32RT U32RT U32RT U32RT 400 U32RT U32RT 500 - U34RT U34RT U34RT 500 - U34RT 600 - U36RT U36RT U36RT 600 - U36RT 750 - U39RT U39RT U39RT 750 - U39RT-2 1000 - - - 44RT** 1000 - - * Requires UD-1 dapter * Requires UD-1 dapter ** UD-1 dapter not required ** UD-1 dapter not required Note: Use Burndy Dies with Ilsco ILC-15H crimp tool by installing adapter part no ILD-D E.MEREN.COM 33