GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters
GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for international projects beyond North America all covered under GE s global warranty 2 * Indicates a trademark of the General Electric Company. All other trademarks are the property of their respective owners. 2017 General Electric Company.
Enclosed Full-Voltage Starters Enclosed Full-Voltage Starters GE s answer for NEMA-rated, reliable starting solutions that are easy to install, arrive with express delivery and backed by a global warranty. Flexible. Durable. Compact. The series features non-combination starters with class 10 thermal overload relay protection, compact IEC components that are NEMA-rated, phase loss detection, overcurrent and short circuit protection in a robust design that meets UL & CSA requirements (standardized grounding). The long life cycle, flexibility and ease of use make it ideal for industrial and commercial applications. Suitable for motors ranging from 0.5HP up to 100HP and from 120VAC up to 230VAC in single phase versions, from 208VAC to 600VAC in the three phase version. Enclosure Types: NEMA Type 1 for indoor use. Suitable for most applications that require corrosion-treated sheet steel. NEMA Type 3R for outdoor use. Primarily intended for applications where falling rain, sleet or external ice formations are present. Enclosure is sheet steel, treated to resist corrosion. NEMA Type 12 for indoor use. Provides a degree of protection from non-corrosive dripping liquids, falling dirt and dust. Enclosure is sheet steel, designed to meet tests for drip, dust and rust resistance. NEMA Type 4/4X for indoor or outdoor use. Provides protection from splashing water, hose-directed water and wind blown dust or rain; Enclosure is sheet steel (NEMA 4) or stainless steel (NEMA 4X) to additionally resist salt spray corrosion tests. features include combination and non-combination types with Class-10 and Class-20 overload protection. The product meets UL508A compliance that covers from fractional to 100HP suitable for most commercial and industrial ap plications. Line voltages that are covered in this offering ranges from 208-480Vac, 60Hz, 3-Phase networks. A few of the extended options include ground-fault, phaseloss and elapsed time meter. The series has a high duty cycle and suitable for standard and plugging applications in the industry. 3
Disconnects Breakers (MCCBs Spectra/GuardEon) Transformers Motor Starters (Surion/CL, Efficor Overload relays RT, RE) Control Relays Push Buttons, Pilot Devices (22mm) Up to 15% reduction in system costs versus NEMA Starters Competitive starters can reduce system costs up to 15% compared to traditional NEMA-only enclosed starters. The compact IEC components provide more cabinet space for future add-ons and a reduction in installation time and machine downtime. Benefit from our fast delivery with lead times up to 50% shorter than industry average. 4
Enclosed Full-Voltage Starters 30 to 80% more available space 50% reduced service time versus NEMA Starters Flexible IEC contactors and overload relays are NEMA rated. starters are compliant to: NFPA 70E National Electrical Code (NEC) NEMA ICS 2 Industrial Control Systems (controllers, contactors and overload relays) UL508 ( IEC 60947-4-1 harmonized) Industrial Control Equipment UL508A Industrial Control Panels UL489 Molded Case Circuit Breakers All panels are shipped with: UL/cUL label listing Maximum rating name plate (HP, Voltage, FLA and SCCR ratings) Instruction sheets for components Outline drawings for enclosures Electrical schematics Installation & trouble shooting instructions Our DIN-rail mounted devices make serviceability or field replacements easier and faster than before! 2x shorter lead time Designed for Global Applications enclosed full-voltage, non-reversing starters are suitable for global applications with constant or variable torque, applications like: Chilled water pumps Condensor water pumps Cooling tower fans Elevators Blowers Cranes & Hoists Conveyors Air-Handlers Process applications 5
Enclosed Full-Voltage Starters Full-voltage, non-combination, non-reversing starter 480VAC (±10%),3 Phase 60Hz 600VAC (±10%), 3 Phase, 60Hz 208VAC (±10%), 3 Phase, 60Hz 230VAC (±10%), 3 Phase, 60Hz 208-240VAC (±10%), 1 Phase,60Hz HP ratings from 0.5HP up to 100HP Full-voltage, combination, non-reversing starter Nominal voltage rating is 480VAC (±10%), 60Hz Nominal voltage rating is 600VAC (±10%), 60Hz Nominal voltage rating is 208-240VAC (±10%), 3-Phase, 60Hz 208-240VAC(±10%) 1 Phase, 60Hz Fusible & non-fusible disconnects Thermal magnetic circuit breakers Magnetic-only circuit breakers Type 2 coordination (optional) 575V AC MCP combination NEMA/IEC magnetic starter, size 1, NEMA 1 enclosure 575V AC fused combination NEMA/IEC magnetic starter, size 2, NEMA 3R enclosure 575V AC fused combination NEMA/IEC magnetic starter, size 2, NEMA 3R enclosure 6
Enclosed Full-Voltage Starters Starter includes the following accessories, unless otherwise specified: Auxiliaries with 1 or 2 NO and 1 or 2 NC contacts Start/Stop push-button: 22mm Standard LED pilot lights. Color and functionality to be provided (red wired across coil, through NO, etc.) IP20 rated terminals Ground lugs (1) on the enclosure chassis, (1) on the back plate Optional features: CPT (control power transformer), with fuse block, and primary and secondary fuses Hand/Off/Auto selector switch Auxiliary contacts: 1 or 2 NO and 1 or 2 NC contacts Control relay with additional 2 NO and 2 NC Electronic timer with multi-function features Ground fault protection Elapsed time meter Monitoring capability Electronic overload relay (no external CT up to 25HP) 7
Selection Overview Starter Base Unit NEMA Size Starter Type Disconnect Max. Voltages (VAC) Max. HP Avaliable HP@600Vac Irms @ Max. HP@600Vac Applicable Standards NO CPT CPT Control Power Transformer Enclosure NEMAType 1, 12, 3R & 4X Amb.Compensated O/L 0 1 2 3 Combination/ Non-Combination FVNR Combination/ Non-Combination FVNR Combination/ Non-Combination FVNR Combination FVNR Non-Fusible Fusible Non-Fusible SPECTRA Thermal CB Fusible Non-Fusible SPECTRA Thermal CB Fusible Non-Fusible SPECTRA Magnetic CB Fusible Non-Fusible SPECTRA Thermal CB 600 5 1, 2, 3, 5 6.1 UL508,UL508A NEC2008/NFPA70E Ref. to Nomenclature Primary 208, Secondary 120Vac Primary 208, Secondary 120Vac Primary 480, Secondary 120Vac Primary 480/240, Secondary 24Vac Primary 575, Secondary 120Vac 600 10 5, 7.5, 10 11 600 25 15, 20, 25 27 600 50 30, 40, 50 52 CLASS 10 CLASS 10 CLASS 10 CLASS 10 CLASS 20 (Optional) CLASS 20 (Optional) CLASS 20 (Optional) CLASS 20 (Optional) 4 Combination FVNR Fusible Non-Fusible SPECTRA Thermal CB 600 100 60, 75, 100 99 CLASS 10 CLASS 20 (Optional) Product in blue and bold = available - Product in black and plain = available Q3/2017 208VAC/60Hz available up to 40HP Table A - RT Thermal overload relay, Trip Class 10 NEC 2002 Table 430.150, FLA, 3 Ph. AC Motors, HP@380v derived from UL508, Table 45.2 200 208 230 460 575 HP Volts Volts 4,2 Volts Volts 1 4.8 4.6 2.1 1.7 2 7.8 7.5 6.8 3.4 2.7 3 11 10.6 9.6 4.8 3.9 5 17.5 16.7 15.2 7.6 6.1 7.5 25.3 24.2 22 11 9 10 32.2 30.8 28 14 11 15 48.3 46.2 42 21 17 20 62.1 59.4 54 27 22 25 78.2 74.8 68 34 27 30 92 88 80 40 32 40 120 114 104 52 41 50 150 143 130 65 52 60 177 169 154 77 62 75 221 211 192 96 77 100 285 273 248 124 99 NEMA sizes 00-1 0-1 1 2-3 3 4 CLNA, CLNB, CLNB, CLNC CLND, CLNE CLNF CLNC CLNC CLNE A - - - 11.5-15 - - B 0.16-0.26 - - 14.5-19 - 55-80 C 0.25-0.41 - - 18.5-25 - 63-90 D 0.4-0.65 - - 24-32 - 90-120 E - - - 30-43 - 110-140 F 0.65-1.1 - - - - - G 1.0-1.5 - - 42-55 - - H 1.3-1.9 - - - 54-65 - J 1.8-2.7 - - - 64-82 - K 2.5-4.1 - - - - - L 4.0-6.3 - - - 78-97 - M 5.5-8.5 - - - - - N 8.0-12.0 - - - - - P - 10.0-16.0 - - - - S - 14.5-18 - - - - T - - 17.5-22 - - - U - - 21-26 - - - V - - 25-32 - - - W - - - - - - 8 Do not exceed contactor current rating when selecting and adjusting overload relays.
Enclosed Full-Voltage Starters Options Elect. O/L NO O/L Rly MMS MCB High SCCR (Fuses) Standard SCCR (Breaker) Aux. Contacts 1N/O & 1N/C Aux. Contacts 2N/O & 2N/C Start/Stop ON-OFF H-O-A Switch Hour Meter Emergency Stop RED ON GREEN OFF Optional Optional High SCCR 100kA(Type J Fuses) High SCCR 25-42kA(Type J Fuses) Optional Optional - Optional Table B - RE Electronic overload relay, Trip Class 5-10-20-30 NEMA sizes 00-1 3 4 OL Range CLNA, CLNB, CLNC CLNE CLNF Code A - - - B - - - C - - - D 0.1-0.5 - - E - - 30-150 F - - - G - - - H 0.4-0.2 15-75 - J - - - K 1.0-5.0 - - L - - - M 1.6-8.0 22-110 - N - - - P - - - S 6.4-32 - - T - - - U - - - V - - - W 9.0-45 - - IEC NEMA size Continuous current Max. HP Rating - 3 phase HP (from UL file E76233) 200V 230V 460V 575V AC AC AC AC CLNA 00 9 1.5 1.5 2 2 CLNB 0 18 3 3 5 5 CLNC 1 27 7.5 7.5 10 10 CLND 2 45 10 15 25 25 CLNE 3 90 25 30 50 50 CLNF 4 135 40 50 100 100 Hp Hp Rating Rating 208V 240V 480V 600V 208V 240V 480V 600V 1 0 0 0 0 25 3 3 2 2 2 0 0 0 0 30 4 3 3 3 3 0 0 0 0 40 4 4 3 3 5 1 1 0 0 50 4 3 3 7 1/2 1 1 1 1 60 4 4 10 2 2 1 1 75 4 4 15 3 2 2 2 100 4 4 20 3 3 2 2 9
Selection Guide Example Catalog Number CR508N295050JNL7A Digits # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 CR 5 0 8 N 2 9 5 0 5 0 J N L 7 A STEP: 1 2 3 4 5 6 7 8 9 10 Product Line Code Digit # 1, 2, 3 504 = NEMA RATED IEC CONTACTOR STARTER PANEL - COMBINATION - NON-FUSIBLE 507 = NEMA RATED IEC CONTACTOR STARTER PANEL - COMBINATION - THERMAL CB 508 = NEMA RATED IEC CONTACTOR STARTER PANEL - COMBINATION - FUSIBLE 587 = NEMA RATED IEC CONTACTOR STARTER PANEL - COMBINATION - MAG. ONLY 506 = NEMA RATED IEC CONTACTOR STARTER PANEL - NON COMBINATION Input Voltage Digit # 4 C = 208V (Max. xx HP) H = 460V (Max. xxxhp) N =575V (Max. xxxhp) Enclosure Type Digit # 5 1 = NEMA 1 2 = NEMA 12 4 = NEMA 4 6 = NEMA 3R Control Voltage Digit # 6, 7 05 = NO CPT F5 = CONTROL CIRCUIT FUSE 95 = 600V/120V w/cpt HP Rating Digit # 8, 9, 10 002 = 2Hp 010 = 10Hp 050 = 50Hp 100 = 100Hp Overload Relay Digit # 11 9 = STANDARD (1NC+1NO) - THERMAL, CLASS 10 (Refer Table A ) X = ELECTR. OVERLOAD RELAY CLASS 5-10-20,-30 adjustable (1NC+1NO) (Refer Table B ) (1)Z = NONE (No Overload Relay) Auxiliary Contacts Digit # 12 A = NONE D = 1NO-1NC N = 2NO-2NC Push Button/Selector Switch Options Digit # 13 A = NONE J = Start (Black) / Stop (Red) Push Button L = Hand-Off-Auto (HOA) Selector Switch M = Off-On Selector Switch Pilot Light Options (LED light) Digit # 14 A = NONE 6 = Red - Across Coil & Green - Thru NC Aux Contact 7 = Red - Across Coil & Green - Thru NC Aux Contact & Amber (Overload) 10 Control Options Digit # 15 # Table A = RT Thermal Overload Relay, Trip Class 10 # Table B = RE Electronic Overload Relay (SSOL) Notes: (1) Option Z NONE under overload relay is not available with magnetic-only 587 starter panel products. (2) CCF is included when: Fuse clip size is more than 100Amps Magnetic only circuit breaker is more than 7Amps Thermal circuit breaker is more than 100Amps
Enclosed Full-Voltage Starters Popular Model Numbers Codes Type of starter 575V AC fused combination NEMA/IEC magnetic starter Size 0, NEMA 1 enclosure Size 1, NEMA 1 enclosure Size 2, NEMA 1 enclosure Size 3, NEMA 1 enclosure Size 0, NEMA 3R enclosure Size 1, NEMA 3R enclosure Size 2, NEMA 3R enclosure Size 3, NEMA 3R enclosure Size 0, NEMA 12 enclosure Size 1, NEMA 12 enclosure Size 2, NEMA 12 enclosure Size 3, NEMA 12 enclosure Size 0, NEMA 4X enclosure Size 1, NEMA 4X enclosure Size 2, NEMA 4X enclosure Size 3, NEMA 4X enclosure 575V AC non-fused combination NEMA/IEC magnetic starter Size 0, NEMA 1 enclosure Size 1, NEMA 1 enclosure Size 2, NEMA 1 enclosure Size 3, NEMA 1 enclosure Size 0, NEMA 3R enclosure Size 1, NEMA 3R enclosure Size 2, NEMA 3R enclosure Size 3, NEMA 3R enclosure Size 0, NEMA 12 enclosure Size 1, NEMA 12 enclosure Size 2, NEMA 12 enclosure Size 3, NEMA 12 enclosure Size 0, NEMA 4X enclosure Size 1, NEMA 4X enclosure Size 2, NEMA 4X enclosure Size 3, NEMA 4X enclosure 575V AC MCP combination NEMA/IEC magnetic starter Size 0, NEMA 1 enclosure Size 1, NEMA 1 enclosure Size 2, NEMA 1 enclosure Size 3, NEMA 1 enclosure Size 0, NEMA 3R enclosure Size 1, NEMA 3R enclosure Size 2, NEMA 3R enclosure Size 3, NEMA 3R enclosure Size 0, NEMA 12 enclosure Size 1, NEMA 12 enclosure Size 2, NEMA 12 enclosure Size 3, NEMA 12 enclosure Size 0, NEMA 4X enclosure Size 1, NEMA 4X enclosure Size 2, NEMA 4X enclosure Size 3, NEMA 4X enclosure 575V AC non-combination NEMA/IEC magnetic starter Size 0, NEMA 1 enclosure Size 1, NEMA 1 enclosure Size 2, NEMA 1 enclosure Size 3, NEMA 1 enclosure Size 0, NEMA 3R enclosure Size 1, NEMA 3R enclosure Size 2, NEMA 3R enclosure Size 3, NEMA 3R enclosure Size 0, NEMA 12 enclosure Size 1, NEMA 12 enclosure Size 2, NEMA 12 enclosure Size 3, NEMA 12 enclosure Size 0, NEMA 4X enclosure Size 1, NEMA 4X enclosure Size 2, NEMA 4X enclosure Size 3, NEMA 4X enclosure Catalogue Number CR508N1950059DL6M CR508N1950109DL6N CR508N1950259DL6D CR508N1950509DL6G CR508N6950059DL6M CR508N6950109DL6N CR508N6950259DL6D CR508N6950509DL6G CR508N2950059DL6M CR508N2950109DL6N CR508N2950259DL6D CR508N2950509DL6G CR508N4950059DL6M CR508N4950109DL6N CR508N4950259DL6D CR508N4950509DL6G CR504N1950059DL6M CR504N1950109DL6N CR504N1950259DL6D CR504N1950509DL6G CR504N6950059DL6M CR504N6950109DL6N CR504N6950259DL6D CR504N6950509DL6G CR504N2950059DL6M CR504N2950109DL6N CR504N2950259DL6D CR504N2950509DL6G CR504N4950059DL6M CR504N4950109DL6N CR504N4950259DL6D CR504N4950509DL6G CR587N1950059DL6M CR587N1950109DL6N CR587N1950259DL6D CR587N1950509DL6G CR587N6950059DL6M CR587N6950109DL6N CR587N6950259DL6D CR587N6950509DL6G CR587N2950059DL6M CR587N2950109DL6N CR587N2950259DL6D CR587N2950509DL6G CR587N4950059DL6M CR587N4950109DL6N CR587N4950259DL6D CR587N4950509DL6G CR506N1950059DL6M CR506N1950109DL6N CR506N1950259DL6D CR506N1950509DL6G CR506N6950059DL6M CR506N6950109DL6N CR506N6950259DL6D CR506N6950509DL6G CR506N2950059DL6M CR506N2950109DL6N CR506N2950259DL6D CR506N2950509DL6G CR506N4950059DL6M CR506N4950109DL6N CR506N4950259DL6D CR506N4950509DL6G 11
GE Energy Connections 124158 Since Thomas Edison patented the world s first circuit breaker, Industrial Solutions has been transforming the future of electrification. We design electrical solutions at the crossroads of digital and industrial smart, rugged and equipped to control electricity from the grid to its point of use. Every day, we partner with our customers to solve their toughest energy challenges and reimagine industry in a way that only the world s digital industrial company can. North America GE Technical Support PH: (800) 431-7867 Technical questions regarding products Obsolete parts Manufacture cross reference Publications and wiring diagrams Application support GE 1-STOP (Customer Service): PH: (800) GE-1STOP; Group# 182 FAX: (866) 744-6322 Shipping status, cancellation and change orders for components only Price and availability Expedite component orders only Renewal parts GE RESOLVE (Warranty Issues) PH: (888) 437-3765 Warranty & defective product Incorrect shipment by factory ca.geindustrial.com DEC1001 * Trademark of General Electric Company Copyright GE Energy Connections 2017