Physical Specifications

Similar documents
Proximity Sensors. Reference Information. Principles of Operation. Proximity Sensors

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Switchgear Skid, C1192

RMR Standard Wall-Mount Enclosures

RMR Floor-Mount Enclosures

GE 8000-Line Motor Control Centers

Cable Festoon Systems - For Moving Machinery

Standard VVMC-1000 or VFMC-1000 controls, dispatched by an M3 Group System, allow group configurations with 64 landings and as many as 12 cars.

Cable Festoon Systems - For Moving Machinery

Proximity Sensors. Reference Information. Principles of Operation. Proximity Sensors

APX Technologies, lnc.

Type 4X Panel Enclosures

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Instruction, LS-EDGE Installation

IMC/PTC Elevator Data Forms

User s Manual. ACS550-PC/PD Packaged Drive with Disconnect Supplement to ACS550-01/U1 User s Manual

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Cable Festoon Systems. C-Track Stretch Wire Rope

Type 4X Panel Enclosures

1 of 2 8/31/2009 5:30 PM

Type 4 Panel Enclosures

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Industrial & Harsh Environment - Battery Units

Caution Improper installation could result in tape failure, mounting hardware, and reader. Please read instructions before installing!

Outdoor Enclosure Power System ENC X100MP48F20-AC6

DC3N Non-Regenerative DC Drives

MALSR APPROACH LIGHTING. Medium-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS AND STEADY BURNING LIGHTS

Wireless Vehicle Sensor

The Navigator Elevator Landing System. Installation Manual. System Components: Selector Operation. Digital Connection

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

Outdoor Enclosure Power System ENC X100MP48F20

RMR Free-Standing Enclosures

NEMA 4/12-19" Rack Server Cabinet - Floor Mount KEY FEATURES EXCELLENT QUALITY. Quad Electrical Outlet Box (Option)

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES

Wireless Accelerometer - Vibration Meter

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

Cable Festoon Systems. C-Track Stretch Wire Rope

Owner's/Installation Manual

14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N

COMPLETE LISTING OF OPTIONS. Toggles, Lights

Type 4 Panel Enclosures

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

Type 4X Panel Enclosures

Tricon by MCE Data Form Motion Control Engineering Phone (916) Fax: (916)

ENCLOSED DISCONNECT SWITCHES

channel bracket 1.50 (38) flat strap shaded area is useable space

Interactive Balancing System

Dual ground lug - one lug for earth ground, one lug for utility ground.

Ch 4 Motor Control Devices

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Belt Scales Table of Contents

Type 4 Panel Enclosures

Bruno VPL-3300B Series

8400 Series Fiber Distribution System

Instruction, LS-EDGE Installation

Wireless Digital Compass

133 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

Operator System Enclosures

Wireless Accelerometer - Vibration Meter

Technical Manual. DLM Module. This manual should remain with the unit.

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

OM004, OM006 & OM008 Oval Gear Meter

FREE-STANDING ENCLOSURE ACCESSORIES FREE-STANDING ENCLOSURE ACCESSORIES. Swing-Out Panels. Panels (Full & Half Length) For Single-Door Enclosures

RACK SYSTEMS Racks, Rack Enclosures, Cable Managers, Shelves & Accessories

PLEASE COMPLETE AND RETURN AS SOON AS POSSIBLE

Technical data OT16E3 OT160E3 UL & CSA

The UL Type 3R Package is specifically designed for Adjustable Frequency Drives, such as Yaskawa's E7, F7, G7, P7, and iqpump models.

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters

General information about motor protection

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

ALSF APPROACH LIGHTING. High-Intensity Approach Lighting System WITH ELEVATED SEQUENCED FLASHERS. Operating Conditions. Compliance with Standards

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

CLIMAGUARD Outdoor Heat Exchangers

SITESTAR ELECTRONICS CABINET DESCRIPTION

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

MULTI-ZONE FOAMED MACHINE MODEL PARTS MANUAL

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Panel Size. Conductive

Wireless Seat Occupancy Sensor

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

MST. Full Height Turnstiles. alvaradomfg.com

Cisco Nexus 7700 Switches Environment

PFIS Filter Mechanism SPECIFICATION SALT-3130AE VERSION February 2003

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

ILLUSTRATIONS & PARTS LISTS FRONT VIEWS GDF14

H20.5 Series Electric Fryers

Vector Measuring System PARTS MANUAL

MP-Series Integrated Gear Motors

C1000 Series Automatic Cap Bank

UCA ADJUSTABLE ANGLE MULTI COLOR TEMPERATURE

Transcription:

General In This Section Standard Enclosures Landing Systems Load Weighers TLS Switches Physical Specifications General This section is intended to be used as a reference for physical specification of products described in this specification book. This section describes dimensions, weight, and special features of the enclosures and accessory products. The specifications given in this section are primarily for reference and may be changed or modified at any time without notice. Note Where space restrictions apply, multiple enclosures may be needed. Consult your MCE Sales Representative for special enclosure information. 16 In This Section Standard Controller Enclosures Landing System Physical Specifications Load Weighers TLS Terminal Limit Switches 16-1

[228.6] Physical Specifications Standard Controller Enclosures MCE provides NEMA 1 type enclosures for its standard elevator controller products unless otherwise specified. NEMA 1 enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment and against a limited amount of falling dirt. Following is a list of product types and typical enclosures used with each. The enclosures may be used interchangeably, depending upon application. Hydraulic Enclosures This enclosure is primarily used for PHC, HS and IOS control products. It is a steel enclosure with an aluminum or steel sub-plate, louvered sides, removable door and is wall mounted with front access only. Figure 16.1 Hydraulic Enclosure 11.00 34.00 [863.6] 31.50 [800.1] PART NO. 15-01-0001 Part Number: 15-01-0001 (See figure 16.1) Dimensions (inch [mm]): 31.5 [800. 1] H X 34 [863.6] W X 11 [279.4] D Weight full (lbs. [kg]): 135 to 200 [61.29 to 90.8] approximate (depends on product) 16-2 Manual # 42-01-SPECS

Standard Controller Enclosures Figure 16.2 Hydraulic Enclosure 12.00 [304.8] 36.00 [914.4] 42.00 [1066.8] 16 D/N: 4284 R0 Part Number: 15-09-0019 (Figure 16.2.) Dimensions (inch [mm]): 42 [1066.8] H X 36 [914.4] W X 12 [304.8] D Weight full (lbs. [kg]: 200-300 [90.7-136] approximate (depends on product) 16-3

[177.8] 30.000 Physical Specifications Traction Enclosure (Series M) This enclosure is used for PTC and VFMC Series M control products. It is a steel enclosure with an aluminum or steel sub-plate, louvered sides, removable vented resistor box (when required), removable door, and is wall mounted with front access only. Figure 16.3 Traction Enclosure, Series M 12.000 [304.8] PART NO. 15-02-0027 48.000 7.000 [1219.2] 57.000 [1447.8] 36.000 [914.4] [762] THERE ARE LOUVERS ON EACH END OF THE ENCLOSURE THERE ARE LOUVERS ON THREE SIDES OF THE RESISTOR CABINET Part Number: 15-02-0027 (See figure 16.3) Dimensions (inch [mm]): 30 [762] H X 57 [1447.8] W X 12 [304.8] D Weight full (lbs. [kg]): 300-400 [136-181.4] approximate (depends on product) 16-4 Manual # 42-01-SPECS

Standard Controller Enclosures Traction Enclosures (Double Door) This enclosure is used for IMC and PTC control products. It is a steel enclosure with an aluminum or steel sub-plate, louvered sides, removable vented resistor box (when required), removable hinged double doors with keyed lock, and is floor mounted with front access only. Figure 16.4 Traction Enclosure, Double Door 13.00 [330.2] 16.00 [406.4] 39.00 [990.6] 82.50 [2095.5] 67.437 [1712.9] 16 PART NO. 15-02-0035 Part Number: 15-02-0035 (Figure 16.5) Dimensions (inch [mm]): 82.5 [2095.5] H X 39 [990.6] W X 16 [406.4] D Weight full (lbs.[kg]): 395 to 600 [179.3 to 272.4] approximate (depends on product) 16-5

Physical Specifications Figure 16.5 Traction Enclosure, Double Door 16.00 [406.4] 39.00 [990.6] 15.50 [393.7] 39.00 [990.6] 85.50 [2171.7] PART NO. 15-02-0034 Part Number: 15-02-0034 (Figure 16.6) Dimensions (inch [mm]): 85.5 [2171.7] H X 54.5 [1384.3] W X 16 [406.4] D Weight full (lbs.[kg]): 800-900 [362.8-408.2] approximate (depends on product) 16-6 Manual # 42-01-SPECS

Standard Controller Enclosures Group Enclosure This enclosure is used for the M3 Group System. It is a steel enclosure with a steel swing out sub-plate, louvered top, hinged door with keyed lock, slide out keyboard tray and CRT rack, and is floor mounted with front access only. Figure 16.6 Group Enclosure 19.000 [457.2] 24.000 [609.6] 70.50 [1790.7] 16 PART NO. 15-03-0003 "M3" GROUP SUPERVISOR Part Number: 15-03-0003 (See figure 16.7) Dimensions (inch [mm]): 70.5 [1790.7] H X 24 [609.6] W X 19 [482.6] D Weight full (lbs. [kg]): 200 to 300 [90.8 to 136.2] approximate (depends on product) 16-7

Physical Specifications Off-the-Shelf Enclosures For applications where MCE's standard enclosures are not appropriate, a wide range of off-theshelf NEMA rated enclosures are available from various manufacturers. For physical dimensions and pricing on these enclosures, consult your MCE Sales Representative. Below is a list of the more commonly used NEMA rated enclosures for elevator applications: NEMA 1 For special applications or space restrictions in which MCE standard enclosures cannot be used. Note In some cases, multiple enclosures may be needed where space restrictions apply. NEMA 4 Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust, rain, splashing water and hose directed water; undamaged by the formation of ice on the enclosure. Note A cooling system may be required for some types of controllers (see dimensions below). 16-8 Manual # 42-01-SPECS

Standard Controller Enclosures Figure 16.7 NEMA 4 Enclosure 24.60" [624.8] 50.60" [1285.2] 37.60" [955] 14.50" [368.3] 72.60" [1844] 13.00" [330.2] 84.60" [2148.8] 5.05" [123.3] 32.25" [819.15] 38.25" [971.6] 16 Part Number: 15-09-0136 (See figure 16.8) Enclosure Dimensions (inch [mm]): 84.6 [2148.8] H X 37.6 [955] W X 24.6 [624.8] D AC Dimensions (1000 to 4000 BTU) 32.25 [819.15] H X 14.5 [368.3] W X 13 [330.2] D AC Dimensions (4000 to 8000 BTU) 37.75 [958.85] H X 18.56 [471.43] W X 18 [457.2] D Weight full (lbs. [kg]): 900-1000 [408.2-453.6] approximate (depends on product) 16-9

14.50" [368.3] Physical Specifications NEMA 4X Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust, rain, splashing water and hose-directed water; undamaged by the formation of ice on the enclosure. NOTE: A cooling system may be required for some types of controllers (see dimensions below). Figure 16.8 NEMA 4X Enclosure 16.00" [406.4] 49.00" [1244.6] 36.00" [914.4] 13.00" [330.2].75" [19.1] 60.00" [1524] 72.00" [1828.8] 32.25" [819.15] 38.25" [971.6] Part Number: 15-09-0145 (See figure 16.9) Enclosure Dimensions (inch [mm]): 72 [1828.8] H X 36 [914.4] W X 16 [4.6.4] D AC Dimensions (1000 to 4000 BTU) 32.25 [819.15] H X 14.5 [368.3] W X 13 [330.2] D AC Dimensions (5000 BTU) 32.875 [832.03] H X 12.5 [317.5] W X 9.5 [241.3] D Weight full (lbs. [kg]): 800-900 [362.8-408.2] approximate (depends on product) 16-10 Manual # 42-01-SPECS

Standard Controller Enclosures NEMA 12 Enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt and dripping noncorrosive liquids. Note A cooling system may be required for some types of controllers (see dimensions below). Figure 16.9 NEMA 12 Enclosure 16.00" [406.4] 57.00" [1447.8] 48.00" [1219.2] 12.25" [311.1] 60.00" [1524] 9.00" [228.6] 1.88" [47.6] 72.00" [1828.8] 23.50" [597] 17.50" [444.5] 16 Part Number: 15-09-0056-W (See figure 16.10) Enclosure Dimensions (inch [mm]): 72 [1828.8] H X 48 [1219.2] W X 16 [406.4] D AC Dimensions (1000 to 2000 BTU) 17.5 [444.5] H X 12.25 [311.1] W X 9 [228.6] D AC Dimensions (2000 to 5000 BTU) 32.875 [832.03] H X 12.5 [317.5] W X 9.5 [241.3] D Weight full (lbs. [kg]): 800-900 [362.8-408.2] approximate (depends on product) 16-11

[355.6] Physical Specifications Group Dispatcher (IOS) Overlay Enclosure (see Hydraulic Enclosure) Filter Enclosures Primarily used for 6-pulse and 12-pulse filters, these are steel enclosures with an aluminum or steel sub-plate, louvered sides, and a removable door with front access only. Figure 16.10 Filter Enclosure 14.00 26.00 [660.4] 24.00 [609.6] Part Number: 15-09-0050 (See figure 16.11) Enclosure Dimensions (inch [mm]): 24 [609.6] H X 26 [660.4] W X 14 [355.6] D Weight full (lbs. [kg]): 100-200 [45.3-90.7] approximate (depends on product) 16-12 Manual # 42-01-SPECS

Standard Controller Enclosures Figure 16.11 Filter Enclosure 14.00 [355.6] 39.00 [990.6] 26.00 [660.4] PART NO. 15-02-0016 Part Number: 15-02-0016 (See figure 16.12) Enclosure Dimensions (inch [mm]): 26 [660.4] H X 39 [990.4] W X 14 [355.6] D Weight full (lbs. [kg]): 200-300 [90.7-136] approximate (depends on product) 16 16-13

Physical Specifications Landing System Physical Specifications LS-STAN Specifications Refer to Figure 16-13 for LS-STAN. Sensor A vane operated infrared proximity switch manufactured by MCE. Part Number: VS-1 Dimensions (inch [mm]): 1.92 [48.77] H X 1.93 [49.02] W X 1.95 [49.53] D Opening Dim. (inch [mm]): 0.75 [19.05] W X 1. 12 [28.45] D Power Supply Part Number: PS-5A or PS-7A Dimensions (inch [mm]): 1. 03 2 [26.2 1] H X 4.5 [114, W X 3 [76.2] D Enclosure The LS-STAN has a steel enclosure with a rear access screw cover for sensor adjustment; it has five separately adjustable sensor lanes and slots for adjustability in mounting on the car top. Part Number: 15-07-0001 Dimensions (inch [mm]): 16.5 [393.7] H X 10 [254] W X 3.5 [88.9] D Weight (lbs. [kg]): 11 [5. 0] approximately (assembled) Vane Assembly The P4-VANE- 12# is used for 12 lb. rails or smaller, the P4-VANE-15# is used for 15 lb. or 18 lb. rails and P4-VANE-30# is used for 22 or 30 lb. rails; they include the mounting hardware and Unistrut. The vanes are mounted on a P6000 or P7000 Unistrut, are 24" in length, and include rail clips and mounting hardware. Part Number: P4-VANE-12#, P4-VANE-15# or P4-VANE-30# Vane Dim. (inch [mm]): 5.875 [149.23] H X 2 [50.8] W X 3.80 [96.52] D 16-14 Manual # 42-01-SPECS

13.00" 10.00" Landing System Physical Specifications Figure 16.12 LS-STAN VS-1 LS-STAN POWER SUPPLY.250" BOTTOM VIEW.59".75" SIDE VIEW 1.92" 1.12" RED N.O. YELLOW BLUE N.O. LIMITS OF VANE ENTRY.73".66" 1.95" 4.50" CONTACT RATING 60W 125VAC 0.6A 125VAC MADE IN USA 0.6A 110VAC.29".05".965".315" HOOK UP WIRES 1.93" 1.50" 1.032" 3.00" LS-STAN 2.00" LS-STAN VANE ASSEMBLY 5.875" VANE UNISTRUT 15.50" (2) BEAM CLAMPS 2.00" 3.50" RAIL 16 16-15

[114.3] Physical Specifications LS-QUAD-2 Specifications Magnetic Sensor A magnetically operated switch manufactured by MCE. Part Number: LS-PS1 Dimensions (inch [mm]): 0.75 [19.05] bushing and 42 [1066.8] wire Enclosure The LS-QUAD-2 has a steel enclosure with a rear access screw cover for sensor adjustment and has an aluminum front plate for sensor mounting. Part Number: 15-07-0007 Dimension (inch [mm]): 20.8 [528.3] H X 6.5 [165. 1] W X 4.5 [114.3] D Weight (lbs. [kg]): 14 [6.36] approximately (assembled) Figure 16.13 LS-QUAD-2 Enclosure (Rear View) 4.500 20.800 [528.3] 6.500 [165.1] PART NO. LS-QUAD-2(R) 16-16 Manual # 42-01-SPECS

Landing System Physical Specifications Encoder The encoders are mounted on the face plate of the LS-QUAD-2. The passage of the steel tape in front of the encoder optics interrupts beams of light to provide position and speed information for the pattern generator. Tape The tape is perforated with slotted holes. Part Number: 40-10-0003 Dimensions (inch [mm]): 3.11 [78.99] W X. 12 [3.05] thick Hole Dim. (inch [mm]): 0.375 [9.53] H X.625 [16.88] W with 0.75 [19.05] center to center Weight (lbs./ft. [kg/m]): 0.1875 [.280] Tape Mounting Top and bottom bracket assemblies and mounting hardware are included Part Number: TAPE-MT-QUAD Figure 16.14 LS-QUAD-2 Bottom Tape Mounting 16 LS-QUAD-2 TAPE MOUNTING 16-17

Physical Specifications LS-QUTE Specifications Magnetic Sensor A magnetically operated switch manufactured by MCE. Part Number: LS-PS1 Dimensions (inch [mm]): 0.75 [19.05] bushing and 42 [1066.8] wire Enclosure The LS-QUTE has a steel enclosure with a rear access screw cover for sensor adjustment and has an aluminum plate for sensor mounting. Part Number: 15-07-0005 Dimensions (inch [mm]): 12 [304.8] H X 5 [127] W X 3 [76.2] D Weight (lbs. [kg]): 2.0 [.908] approximately (assembled) Tape Part Number: 40-10-0002-B Dimensions (inch [mm]): 3.11 [78.99] W X. 12 [3.05] thick Weight (lbs/ft. [kg/m]): 0.1875 [.280] Tape Mounting Top and bottom bracket assemblies and mounting hardware are included Part Number: TAPE-MT-QUTE Figure 16.15 LS-QUTE Components 3.00" 12.00" 5.00" ENCLOSURE AND TAPE TAPE MOUNTING PART NO. TAPE-MT-QUTE 16-18 Manual # 42-01-SPECS

Landing System Physical Specifications LS-QUIK Specifications Sensor A vane operated infrared proximity switch manufactured by MCE. Part Number: VS-1 (See figure 16.13) Enclosure The LS-QUIK has a steel enclosure with a rear access screw cover for sensor adjustment and has a steel front plate for sensor mounting. Part Number: 15-07-0006 Dimensions (inch [mm]): 20.875 [530.225] H X 6.5 [165. 1] W X 6.625 [168.275] D Weight (lbs. [kg]): 14 [6.36] approximately (assembled) Figure 16.16 LS-QUIK Enclosure 6.625 [168.3] 4.625 [117.5] 6.500 [165.1] LU DZ1 DZ2 LD R5 R4 R3 R2 R1 RO PR DZF DZR 20.875 [530.2] 16 16-19

Physical Specifications Encoder The encoder and follower wheel are mounted on the encoder base plate. The encoder base plate is mounted above the car roller guide assembly. A spring applies pressure to the follower wheel to ensure proper contact with the guide rail. Part Number: LSQK-ENCDR Part Number: 11-02-0003 Encoder Base Plate Figure 16.17 LS-QUIK Wheel Driven Encoder Assembly ENCODER FOLLOWER WHEEL - 6.00 [152.4] DIA. ENCODER 9.00 [228.6] ENCODER PLATFORM 0.250 [6.35] THICK 6.00 [152.4] NOTE: 6.00 [152.4] 2.00 C 2.00 3.00 0.25 REF. 0.281 R SLOT X 1 LG. TYP. 4 SLOTS 0.500 0.500 3.000 3.000 1.00 1.500 1.12 2.24 6.00 NOTE:DIMENSIONS ARE IN INCHES (MILIMETERS) 16-20 Manual # 42-01-SPECS

Landing System Physical Specifications LS-QUIK Vane This vane is used for absolute floor encoding, as well as door zone and leveling. The vane has break-out tabs that are removed to encode the various floors. Part Number: 40-05-0010 Figure 16.18 LS-QUIK Vane SEE DETAIL A NOTE: DETAIL A SLOT 8 PL. 1.000 [25.4] 0.265 [6.73] 0.750 [19.05] 0.520 [13.21] 1.000 [25.4] 3.000 [76.20] 2.000 [50.80] 2.000 [50.80] 12.000 [304.80] 2.000 [50.80] R 0.250 [6.35] 0.750 [19.05] 1.500 [38.10] 0.625 [15.88] 2.000 [50.80] 2.000 [50.80] 2.000 [50.80] 2.000 [50.80] 2.000 [50.80] 2.000 [50.80] 2.040 +0.10 14.000 [355.60] 51.82 +2.54 16 16-21

Physical Specifications Isolated Platform Load Weigher The isolated platform load weigher consists of the following: Part Number: LW-SA-1 Sensor Assembly Part Number: 40-02-0094 Target Brackets (2 each) Part Number HC-LWIPA Enclosure Assembly Figure 16.19 Isolated Platform Load Weigher 7.00 [177.8] 9.00 [228.6] 3.50 [88.9] 11.00 [279.4] 16-22 Manual # 42-01-SPECS

Isolated Platform Load Weigher Figure 16.20 Speaker Enclosure (White) 7.000 [177.8] 7.000 [177.8] 7.125 [181] 4.40 [111.7] 7.125 [181] PART NO. 15-08-0001 5.600 [142.2] 16 5.500 [139.7] 16-23

Physical Specifications Figure 16.21 Speaker Enclosure, Black 7.000 [177.8] 7.000 [177.8] 6.25 [158.8] 4.15 [105.4] 6.25 [158.8] PART NO. 15-08-0003 5.500 [139.7] 5.500 [139.7] 16-24 Manual # 42-01-SPECS

Isolated Platform Load Weigher Figure 16.22 Speaker Enclosure 7.38 [187.3] 6.25 [158.7] MOUNTING FLANGE 7.15 [181.6] 4.38 [111.1] PART NO. 15-04-0004 4.70 [119.4] 2.35 [59.7] MOUNTING FLANGE 16 2.35 [59.7] 4.70 [119.4] 16-25

MODEL: 16.344 [415.1] Physical Specifications TLS Terminal Limit Switches TLS-C-12 and TLS-C-16 are cartop mounted, magnetically operated switch arrays. TLS-1 is an individually sealed, magnetically operated switch mounted on its own bracket. Part Number: TLS-C-12 Dimensions (inch [mm]): 16.344 [415.1] L X 5.875 [149.2] W X 4 [101.6] D Figure 16.23 TLS-C-12 Terminal Limit Switches 5.875 [149.2] MOTION CONTROL ENGINEERING. INC. VOLTAGE: TLS-C- MAX AMPS: REVISION: 250VAC, 10, 60HZ / 115VDC 0.1AMP @ 250VAC 0.2AMP @ 120VAC 0.1AMP @ 115VDC SERIAL: MADE IN U.S.A. WARNING: MORE THAN ONE LIVE CIRCUIT SEE DIAGRAM 4.00 [101.6] 16-26 Manual # 42-01-SPECS

MODEL: TLS-C- SERIAL: MADE IN U.S.A. WARNING: MORE THAN ONE LIVE CIRCUIT SEE DIAGRAM 21.625 [549.2] TLS Terminal Limit Switches Part Number: TLS-C-16 Dimensions (inch [mm]): 21.625 [21.625] L X 5.875 [149.2] W X 4 [101.6] D Figure 16.24 TLS-C-16 Terminal Limit Switches 5.875 [149.2] VOLTAGE: MOTION CONTROL ENGINEERING. INC. MODEL: REVISION: 250VAC, 10, 60HZ / 115VDC MAX AMPS: 0.1AMP @ 250VAC 0.2AMP @ 120VAC 0.1AMP @ 115VDC 4.00 [101.6] 16 16-27

Physical Specifications Part Number: TLS-1 Figure 16.25 TLS-1 Terminal Limit Switches OFF ON ON OFF 16-28 Manual # 42-01-SPECS