Zest Iris Duct Dampers

Similar documents
Tecstrut Channel Suspension & Framing System

Tecduct Plastic Ducting

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

OPTIVENT Housing HVSA, HVSL

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

TBV - Terminal Unit. Halton TBV. Terminal Unit

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

KSOF Fire damper valve

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

KTI Supply air valve. Product Facts. Product code example. Quick Selection

NEW. Iris Control Damper (ICD) For adjustment and measuring of airflow. Features. Quick and simple installation and maintenance

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

KSOM Control exhaust valve

IrisControlDamper. For Adjustment and Measuring of Airflow.

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

CTVK Supply air diffuser

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

VOLUME CONTROL / REGULATING DAMPERS

Regulation and shut-off damper SPB and SPC

Exhaust air diffuser HPKH + Plenum box ATTS

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

J L I e x h a u s t h o o d

Ventiduct nozzle ducts

Pressure control damper ERPA

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

ACTIVENT System. Specifications. Product code example ACTA

Ventiduct nozzle ducts

Supply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)

series RVV Variable flow rate controllers

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

ROOFMASTER STEF-HT ROOF FAN

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

ULA - Valve. Halton ULA. Valve

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Fan - Powered Terminal Unit Series Flow

Blade Features. AirShield Control and Shut Off Dampers. AirShield

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

GDD - Supply Grille. Halton GDD. Supply Grille

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

RECTANGULAR VAV DAMPER TECHNICAL CATALOGUE

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

U X Y W L. Gear wheels. Linkage. In option: Stainless steel AISI 304L , AISI 316L or painted steel (standard RAL)

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

DATASHEET PRODUCT CODE EXAMPLE:

SERIES JN GILBERTS. Jet Diffusers. Features PUBLICATION DIFFUSERS 8 JUNE 2007

SINGLE DUCT TERMINAL UNITS

Mechanical mixing box MBM

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Conical diffuser KHAA TECHNICAL DATA

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

Combustion gas damper EKO-SRB

Ceiling swirl diffusers

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CRP. Commissioning damper, Ductwork Leakage Class 0

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Ceiling swirl diffusers

Kitchen exhaust fan GLEB

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Actionair Control and Shut Off Dampers

Halton Rex 600 RE6 - Adaptable active chilled beam

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

Ceiling swirl diffusers

VARYCONTROL VAV Dual Duct Terminal Boxes

Series HCD Airfoil Control Damper

Exhaust air diffuser EYMA-2 and air intake device DYMA-1

SDV Vane Swirl Diffusers

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

REK, LEK, ROK and LOK

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Catalogue. FlowBar. High Capacity Slot Diffuser.

ROOFMASTER STEF-HT ROOF FAN

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Transcription:

lindab I the ventilation products specialist Zest Iris Duct Dampers Easily readable built in scale (100-315mm) Differential pressure measuring facility. Comprehensive size range. 100% open position allows for easy cleaning. Accurate volume control. Motorised units available.

Description The Zest Iris Damper is an ideal air flow regulator and measuring device for circular ducts. Accurate control, smooth and quiet air flow and reliable measuring results are achieved by the special iris construction. An easily readable scale assists quick and simple adjustment with a standard 13mm spanner. In the fully open position the Zest Iris Damper provides 100% free area with no control mechanism in the airstream allowing easy and effective cleaning of the ductwork system. Use as a control damper The reducing orifice arrangement maintains a uniform airflow over the cross section of the duct. Closure of the iris produces an accurate throttling of air volume with an even air flow pattern, resulting in low noise levels. Use as a measuring device The Iris Damper can be used for measuring air flow rates by means of the orifice plate principle. The accurate control mechanism guarantees exact opening dimensions corresponding to the adjustment scale. Each damper is provided with manometer connections for measuring the differential pressure which then can be directly used to determine the air flow from the measurement scale on the damper casing. The result of the regulation is thus immediately available and any subsequent checks can be carried out very quickly. Each damper is calibrated individually giving accurate measurement results, the method error being as low as +5% dependent on mounting position within the ventilation system (see mounting distances). Construction The Zest Iris Damper is manufactured from hot dipped galvanised steel sheet and equipped with an adjustment scale and measuring connections. The tamper proof control knob is adjusted with the spanner provided (the 80mm dia. has a lockable lever). Spigots are fitted as standard with rubber gaskets. Dimensional Data Size 80 Size 100... 800 Air Tightness The Zest Iris Duct Damper has a through the case air tightness which meets the requirements of the Eurovent Class C. Temperature The Zest Iris Duct Damper is suitable for continuous use from -10ºC up to +80ºC (if there is moisture in the air the damper may freeze but will not be damaged in this condition unless operated whilst frozen). Installation For the best results the Zest Iris Damper should be installed in straight runs of ductwork. The damper may be fixed to ducting with rivets or self-tapping screws. We recommend joints are sealed with Tectape XT or Tecseal sealant to ensure an airtight connection. Flexible ducting may be fixed to the damper using Tecfix banding or clips. Size Range The Zest Iris Damper is available in a comprehensive range of sizes from 80mm to 800mm. Size ød ød L A B Weight kg 80 79 125 120 35 22 0.5 100 99 165 110 30 32 0.5 125 124 188 110 30 32 0.7 150 149 230 110 30 40 0.9 160 159 230 110 30 35 0.9 200 199 285 110 30 42 1.4 250 249 335 132 40 42 2.1 315 314 410 132 40 47 3.5 400 398 525 150 50 62 6.4 500 498 655 170 50 77 9.6 630 628 815 170 50 92 15.6 800 798 1015 270 100 107 25

Selection Diagrams 1 l/s = 3,6 m 3 /h

Selection Diagrams 1 l/s = 3,6 m 3 /h

Recommended Range Diameter Flow Rate Tolerances The accuracy of calibration is +5% if the damper is mounted in a straight length of duct with disturbance free airflow. The illustrations below show typical installations where the measuring tolerances increase to +7% or +10% Typical example of location Recommended safety distance L Typical example of location Recommended safety distance L + 7% + 10% + 7% + 10% > 1 D > 1 D > 2 D > 2 D > 4 D > 2 D > 2 D > 2 D qv air volume (l/s), (m 3 /h) Lp10A Sound pressure level with 4dB room attenuation (10m2 sab room) L Woct Sound power level (db) K oct correction (db) pt total pressure drop (Pa) ps static pressure drop (Pa) pm Pressure difference (Pa) m 2 measuring tolerance (%) v average velocity (m/s) L Woct

Sound Characteristics CORRECTION K oct (db) IRIS Middle frequency by octave band (Hz) 63 125 250 500 1000 2000 4000 8000 80 10 16 12 9 5-1 -6-23 100 25 21 16 9 4-6 -12-25 125 17 17 13 7 1-4 -6-17 150 21 20 14 8 0-6 -16-29 160 19 18 14 6-1 -6-13 -25 200 20 17 12 5-2 -5-14 -26 250 16 12 8 3 1-4 -17-32 315 24 12 5 0 1-2 -13-27 400 15 9 6 2-1 -4-9 -13 500 14 7 4 1-1 -4-8 -11 630 15 7 3 2-1 -5-9 -11 800 9 5 3 3-1 -6-10 -13 Tol. + 6 3 2 2 2 2 2 3 The sound power levels of the duct for each octave band are obtained by adding the corrections K oct of octave bands (see table) to the total sound pressure level Lp10A db(a) according to the following formula: L woct = Lp10A + K oct Correction K oct is the average in the range of use of the IRIS regulation and measuring device. Options Motorised Iris Damper Motor driven Iris Duct dampers are available in the following sizes; 100, 125, 160, 200, 250 and 315mm diameters. These units offer stepless adjustment between the minimum and maximum settings or by a three position manual switch. Please request our separate data sheet. Stainless Steel Iris Damper Manufactured from AISI 316/316L stainless steel to meet the most stringent requirements. Ideal for laboratories, cleanrooms and any industrial process where corrosion maybe a problem. Available in 100, 125, 160, 200, 250, 315, 400, 500, 630 and 800mm diameters (for sizes 150, 300 and 355 stainless steel reducers are available). LINDAB Ltd E-mail: sales@lindab.co.uk Internet: www.lindab.co.uk North London 020 8805 3656 South London 020 8603 0850 Basildon 01268 532016 Belfast 02890 781607 Birmingham 0121 552 6100 Bristol 0117 977 1345 Cardiff 02920 794503 Exeter 01626 835032 Gateshead 0191 482 5995 Glasgow 0141 419 3800 High Wycombe 01494 463490 Kent 01474 579800 Leeds 0113 297 1111 Leicester 0116 255 6044 Lincoln 01522 567087 Manchester 0161 876 0688 Norwich 01603 747532 Nottingham 0115 985 1923 Sheffield 0114 244 5444 Southampton 023 8026 2111 Stoke-on-Trent 01782 383460 Every effort is made to ensure that the information contained in Lindab literature, drawings and correspondence is accurate, but no warranty is given in this respect and the Company shall not be liable as a result of any inaccuracy. The Company reserve the right to alter at anytime, without prior notice, the design, specification, packaging or price of any article and without incurring any obligation. Ref: 174/0612 www.lindab.co.uk