TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

Similar documents
NEW F ROOF FANS TEDH F400 ECOWATT TEDV F400 ECOWATT. F Roof Fans CENTRIFUGAL BACKWARD IMPELLER - EC MOTOR < M 3 /H

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

HIGH TEMPERATURE TWIN SQUIF FANS

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

CYCLONE F 400 smoke extraction casing

Powerful centrifugal fans for universal use: The product ranges TEM and REM

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Short casing. Long casing (L version) Commercial premises

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

IN-LINE CENTRIFUGAL DUCT FANS VT Series

ACOUSTIC CABINET FANS CVB / CVT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series

BPF. Centrifugal Plug Fans

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CHMT Series, F Rated Fans

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

HIGH-POWERED VENTILATORS

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

Section 4. Axial Fans - Section 4

Energy-saving motors (ESM)

CGT Series Adjustable Pitch Fans

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

MAJAX-2 GENERAL SPECIFICATION

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

ROOFMASTER STEF-HT ROOF FAN

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Novenco Tunnel Fans. Novax October 2007

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

AC Commercial Fans Edition. ErP ready

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CGT Series Adjustable Pitch Fans

BIFLOW SB CON Product Brochure

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

CYLINDRICAL CASED AXIAL FLOW FANS

AXIAL FANS Catalogue CN0050C01 May 2008

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

NCF fans 50 Hz. Protection class IP 55

TGT Series Adjustable Pitch Fans

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

VORTICENT C E RANGE Centrifugal fans

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

TGT Series Adjustable Pitch Fans

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Centrifugal medium-pressure fans fitted with multi-blade

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

FLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information

Specifications ROOF MOUNTED SEAT SERIES. ATEX version. 1 - Roof unit kit. 2 - Enclosed pedestal. Roof unit kit includes:

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

Performance. Sound Levels. Impellers. Motors. Accessories

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

TWINFLOW STDR Product Brochure

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

AXUS HIGH TEMPERATURE AXIAL FANS

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

GigaBox centrifugal fans Product specific information

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.


ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

VORT QBK SAL KC RANGE COMMERCIAL VENTILATION

CBP COMBIBOX CONCEPT. Configurations DESCRIPTION OF VENTILATION MODULES

Sabre Plate Mounted Sickle Fans (VSP)

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

MegaBox Product-specific information

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

NCF 60 Hz. Protection class IP 55

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

ROOF MOUNTED FANS MAX-TEMP Series, Centrifugal 400 ºC/2h Rated Fans

Transcription:

N OU VE A U Approved F400 10 (400 C 10 mn) CE marked Special range for speed variation VAR Easy installation and maintenance Low sound level Electrical accessories and relay box mounted wired New vertical cap TCDH F400 Application Commercial buildings, professional commercial kitchen extract installations, industrial buildings The centrifugal roof mounted smoke extract fans TCDV/H F400 and TCDV/H F400-VAR are designed and certified to : - Extract smoke and hot gaz in case of fire for «high», «public» or industrial buildings. - Extract spoilt air in commercial and industrial buildings installations and extract pollutants inside professional kitchen applications. Suitable for continuous operation within temperatures up to + 40 C for TCDV F400 and + 80 C for TCDH F400. Approved F400 10 (400 C 10 mn) in conformity with the European standard NF EN 1101-3. - TCDV F400 : PV CTICM N 05-E-178 - TCDH F400 : PV CTICM N 05-E-181 CE marked : - TCDV F400 : N 1166-CPD-0039 - TCDH F400 : N 1166-CPD-0038 Range Backward curved impeller manufactured from galvanised steel directly mounted on the motor. Aluminium alloy hub. Inlet base, motor s arm and support manufactured from galvanised steel. Cowl manufactured from grey polyethylene, with vertical discharge TCDV F400, with horizontal discharge TCDH F400 fixed by 4 bolts. Wire mesh bird guard manufactured in accordance with NFE 09010 standard for persons protection. Standard motor flange type B5, class F : - 1 speed three phase, 30/400V, 50Hz, IP 55. - speeds three phase, 400V, 50Hz, IP 55. Motor VAR flange type B5, class F : - Permit the speed regulation by lost of voltage - 1 speed single phase 30V, 50Hz, IP 54-1 speed three phase 400V, 50 Hz, IP 55. Padlock disconnecting switch with return position All these devices are controlled (balancing, motor ) in conformity with CE standard at nomina speed (electrical consumption, vibration). 174 versions : - TCDH F400 with horizontal discharge : - economic version - complete protection of the motor - TCDV F400 with vertical discharge : - reduction of the sound level - motor and impeller completely covered/masked - lesser dirtying of the immediates surroundings 11 nominal sizes, from 700 to 5 000 m3/h. Options Description TCDV F400 Electrical accessories mounted wired. Relay box type Pilot Air, mounted wired for TCDH F400 and mounted for TCDV F400, factory wired in conformity with NFS 61 93 standard. Mounting support for Relay box used TCDH F400. Epoxy paint finish for mildly corrosive atmosphere. Roof fans for explosive atmosphere : In conformity with ATEX 94/9/CE directive, groupe II, category G, for an installation in area 1. Confer Chapter 3 technical and industrial ventilation. Motorization 60 Hz : please enquire. Roof fans without disconnecting switch installed : please enquire.

Dimension TCDH F400 TCDV F400 Model Ф Wheel (outside blades) A BV CV BH CH D E F Weight (kg) 010 68 430 40 595 415 470 181 344 30 15 00 30 430 40 595 435 470 17 344 30 18 030 375 540 515 745 55 596 56 450 30 5 040 430 540 515 745 565 596 94 450 30 8 060 477 660 605 910 615 661 36 570 30 50 080 515 660 605 910 635 661 36 570 30 60 105 565 800 700 1100 760 849 399 668 30 75 110 630 800 700 1100 785 849 444 668 30 80 140 695 946 80 180 913 1037 490 830 30 90 195 760 946 80 180 938 1037 537 830 30 100 50 810 1030 90 1415 975 1037 581 830 40 10 Accessories Standard support : TCDZ 01 Sealing frame : TCDZ 0 Backdraft damper : TCDZ 03 Stack silencer : SILS Model A E G J K M P 010 430 344 368 630 300 145 30 00 430 344 368 630 300 145 30 030 540 450 478 630 400 145 30 040 540 450 478 630 400 145 30 060 660 570 598 700 490 170 40 080 660 570 598 700 490 170 40 105 800 668 698 700 605 170 40 110 800 668 698 700 605 170 40 140 930 830 866 700 730 190 40 195 930 830 866 700 730 190 40 50 930 830 866 700 730 190 40 175

Encombrement Flat roof upstands Horizontal TCDZ 04 For installation of the roof fan on the horizontal smooth without mason s stack. Standard version. Version with an internal 15 mm melamine isolant in order to avoid condensation. Installation of the backdraft damper TCDZ 03 on top. E Slopped TCDZ 07 For installation of the roof fan on slopped smooth without mason s stack. Slopped angle α from 0 to 45 by step of 5. Standard version. Version with an internal 15 mm melamine isolant in order to avoid condensation. Installation of the backdraft damper TCDZ 03 on top. Model A B C E 010/00 48 368 344 300 030/040 538 478 450 300 060/080 658 598 570 300 105/110 758 698 668 300 140/195/50 96 866 830 300 Adapter plate with circular flange TCDZ 05 To connect directly a duct to the roof fan. To be mounted at the roof fan inlet. Allow the roof fan to be disconnected from the base without having to remove the duct. E B C ØD Model B C Ø D E 010/00 368 344 50 55 030/040 478 450 315 55 060/080 598 570 450 68 105/110 698 668 560 68 140/195/50 866 830 710 85 Tipping kit TCDZ 06 Allow the cleaning of the duct and the impeller. 60 pivot on the sealing frame, hold by chain and security bar. Watertight seal supplied. Could be mounted on fl at roof-up stand TCDZ04. 176

Performance curves In conformity with ISO 5801 standard, air density 1, kg/m3. NOTE : for the roof fans fi tted with backdraft damper (TCDZ 03), an additional drop pressure of 50 Pa should be used. The sound pressure levels illustrated have been measured in hemispherical fi eld conditions at a distance of 6 m from the sound source. Inlet connected ; Lp en db (A). The values of sound pressure level illustrated in the curves below correspond to the TCDV F400. In duct sound power levels ; Lw in db (A). 177

Performance curves The sound pressure levels illustrated have been measured in hemispherical fi eld conditions at a distance of 6 m from the sound source. Inlet connected ; Lp en db (A). 178 In duct sound power levels ; Lw in db (A).

Technical Single phase roof fans - 1 speed sliding motor VAR Rotation speed (r.p.m) Nominal Power (kw) Nominal Current (A) Lp A db(a) at 6m in hemispherical field conditions Padlock Disc. Switch Return pos. off Electronic speed controller Circuitbreaker Autotransformer speed controller 30 V TCDV TCDH Comf./Smoke 30V mono 30 V mono 30 V TCDV/H F400 010-4 mono VAR 1500 0,18 1.7 45 47 INTZ 0.16 DIJZ 05.,5 VARZ 3A00 VAMZ 500 TCDV/H F400 00-4 mono VAR 1500 0,18 1.7 53 54 INTZ 0.16 DIJZ 05.,5 VARZ 3A00 VAMZ 500 TCDV/H F400 00-6 mono VAR 1000 0,1 1. 40 43 INTZ 0.16 DIJZ 05.1,6 VARZ 3A00 VAMZ 500 TCDV/H F400 030-4 mono VAR 1500 0,37 3 55 57 INTZ 0.16 DIJZ 05.4 VARZ 3A00 VAMZ 1000 TCDV/H F400 030-6 mono VAR 1000 0,1 1. 44 45 INTZ 0.16 DIJZ 05.1,6 VARZ 3A00 VAMZ 500 TCDV/H F400 040-4 mono VAR 1500 0,55 3.9 58 59 INTZ 0.16 DIJZ 05.4 VARZ 6A00 VAMZ 1000 TCDV/H F400 040-6 mono VAR 1000 0,5.3 47 50 INTZ 0.16 DIJZ 05.,5 VARZ 3A00 VAMZ 500 TCDV/H F400 060-6 mono VAR 1000 0,5.3 57 61 INTZ 0.16 DIJZ 05.,5 VARZ 3A00 VAMZ 500 TCDV/H F400 080-6 mono VAR 1000 0,37 3 55 56 INTZ 0.16 DIJZ 05.4 VARZ 6A00 VAMZ 1000 Three phase roof fans - 1 speed standard motor Rotation Nominal Nominal Lp A db(a) Relay box at 6m in Disc.Switch hemispherical Circuit-breaker speed Power Current (A) field conditions three 400V Return pos. on/off (r.p.m) (kw) 30V 400V TCDV TCDH 30V Comfort/Smoke 400V Comfort/Smoke 30V 400 V Current (A) TCDV/H F400 010- tri 3000 0,55.3 1.4 63 65 INTZ 0.16 INTZ 0.16 DIJZ 05.,5 DIJZ 05.1,6 8 TCDV/H F400 010-4 tri 1500 0,5 1.4 0.8 45 47 INTZ 0.16 INTZ 0.16 DIJZ 05.1,6 DIJZ 05.1 8 TCDV/H F400 00-4 tri 1500 0,5 1.4 0.8 53 54 INTZ 0.16 INTZ 0.16 DIJZ 05.1,6 DIJZ 05.1 8 TCDV/H F400 00-6 tri 1000 0,18 1.3 0.7 40 43 INTZ 0.16 INTZ 0.16 DIJZ 05.1,6 DIJZ 05.1 8 TCDV/H F400 030-4 tri 1500 0,37 1. 55 57 INTZ 0.16 INTZ 0.16 DIJZ 05.,5 DIJZ 05.1,6 8 TCDV/H F400 030-6 tri 1000 0,18 1.3 0.7 44 45 INTZ 0.16 INTZ 0.16 DIJZ 05.1,6 DIJZ 05.1 8 TCDV/H F400 040-4 tri 1500 0,55.5 1.4 58 59 INTZ 0.16 INTZ 0.16 DIJZ 05.4 DIJZ 05.1,6 8 TCDV/H F400 040-6 tri 1000 0,5 1.7 1 47 50 INTZ 0.16 INTZ 0.16 DIJZ 05.,5 DIJZ 05.1,6 8 TCDV/H F400 060-4 tri 1500 0,75 3. 1.9 57 61 INTZ 0.16 INTZ 0.16 DIJZ 05.4 DIJZ 05.,5 8 TCDV/H F400 060-6 tri 1000 0,5 1.7 1 49 5 INTZ 0.16 INTZ 0.16 DIJZ 05.,5 DIJZ 05.1,6 8 TCDV/H F400 060-8 tri 750 0,1 1.1 0.7 41 43 INTZ 0.16 INTZ 0.16 DIJZ 05.1,6 DIJZ 05.1 8 TCDV/H F400 080-4 tri 1500 1.5 6.1 3.5 66 68 INTZ 0.16 INTZ 0.16 DIJZ 05.6,3 DIJZ 05.4 8 TCDV/H F400 080-6 tri 1000 0,37.1 1. 55 56 INTZ 0.16 INTZ 0.16 DIJZ 05.,5 DIJZ 05.1,6 8 TCDV/H F400 080-8 tri 750 0,18 1.3 0.8 46 48 INTZ 0.16 INTZ 0.16 DIJZ 05.1,6 DIJZ 05.1 8 TCDV/H F400 105-4 tri 1500, 8.5 4.9 67 69 INTZ 0.16 INTZ 0.16 DIJZ 05.9 DIJZ 05.6,3 8 TCDV/H F400 105-6 tri 1000 0,75 3.4 56 59 INTZ 0.16 INTZ 0.16 DIJZ 05.4 DIJZ 05.,5 8 TCDV/H F400 105-8 tri 750 0,37.4 1.4 48 51 INTZ 0.16 INTZ 0.16 DIJZ 05.,5 DIJZ 05.1,6 8 TCDV/H F400 110-6 tri 1000 1,1 4.9.8 64 67 INTZ 0.16 INTZ 0.16 DIJZ 05.6,3 DIJZ 05.4 8 TCDV/H F400 110-8 tri 750 0,55 3.3 1.9 57 60 INTZ 0.16 INTZ 0.16 DIJZ 05.4 DIJZ 05.,5 8 TCDV/H F400 140-6 tri 1000, 9.3 5.4 67 70 INTZ 0.16 INTZ 0.16 DIJZ 05.1,5 DIJZ 05.6,3 8 TCDV/H F400 140-8 tri 750 1,1 5.9 3.4 60 63 INTZ 0.16 INTZ 0.16 DIJZ 05.6,3 DIJZ 05.4 8 TCDV/H F400 195-6 tri 1000 3 11.9 6.8 70 73 INTZ 0.16/INTZ 0.3 INTZ 0.16 DIJZ 05.1,5 DIJZ 05.9 8 TCDV/H F400 195-8 tri 750 1,5 7 4.0 63 66 INTZ 0.16 INTZ 0.16 DIJZ 05.9 DIJZ 05.6,3 8 TCDV/H F400 50-6 tri 1000 5,5 1. 1. 73 76 INTZ 0.3/INTZ 0.45 INTZ 0.16/INTZ 0.3 DIJZ 05.5 DIJZ 05.1,5 16,6 TCDV/H F400 50-8 tri 750 3 1,5 7, 66 69 INTZ 0.16/INTZ 0.3 INTZ 0.16 DIJZ 05.16 DIJZ 05.9 8 Padlock. 179

Technical Three phase roof fans - 1 speed sliding motor VAR Padlock Autotransformer Rotation Nominal Nominal Lp A db(a) Relay box at 6m in hemispherical Disc.Switch speed Power Current (A) field conditions three 400V Ruturn pos. off speed controller (r.p.m) (kw) 400V TCDV TCDH 400V Comfort/Smoke Three phase 400 V Current (A) TCDV/H F400 010- tri VAR 3000 0,37 1,1 63 65 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 010-4 tri VAR 1500 0,5 0,8 45 47 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 00-4 tri VAR 1500 0,5 0,8 53 54 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 00-6 tri VAR 1000 0,18 0,9 40 43 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 030-4 tri VAR 1500 0,37 1,1 55 57 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 030-6 tri VAR 1000 0,18 0,9 44 45 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 040-4 tri VAR 1500 0,55 1.5 58 59 INTZ 0.16 VATZ,5 8 TCDV/H F400 040-6 tri VAR 1000 0,5 1.1 47 50 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 060-4 tri VAR 1500 0,75.3 57 61 INTZ 0.16 VATZ 3,8 8 TCDV/H F400 060-6 tri VAR 1000 0,5 1.1 49 5 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 080-4 tri VAR 1500 1,35,7 66 68 INTZ 0.16 VATZ 3,8 8 TCDV/H F400 080-6 tri VAR 1000 0,37 1.3 55 56 INTZ 0.16 VATZ 1,4 8 TCDV/H F400 105-4 tri VAR 1500, 4.9 67 69 INTZ 0.16 VATZ 6,8 8 TCDV/H F400 105-6 tri VAR 1000 0,75 56 59 INTZ 0.16 VATZ,5 8 TCDV/H F400 110-6 tri VAR 1000 1,1 3 64 67 INTZ 0.16 VATZ 3,8 8 TCDV/H F400 140-6 tri VAR 1000, 5.4 67 70 INTZ 0.16 VATZ 6,8 8 TCDV/H F400 195-6 tri VAR 1000 3 6.7 70 73 INTZ 0.16 VATZ 8,5 8 Three phase roof fans - speeds Padlock Relay box Rotation Nominal Nominal Lp A db(a) at 6m in hemispherical Disc.Switch speeds three speed Power Current (A) field conditions Ruturn pos. off starter 400V (r.p.m) (kw) 400 V TCDV TCDH 400V Comfort/Smoke Current (A) TCDV/H F400 030-4/8 tri 1500/750 DA 0,6/0,15 1.9/0.9 55/36 57/39 INTZ 04.16 DEMZ 04 1/,4 8 TCDV/H F400 040-4/8 tri 1500/750 DA 0,6/0,15 1.9/0.9 58/39 59/4 INTZ 04.16 DEMZ 04 1/,4 8 TCDV/H F400 060-4/6 tri 1500/1000 BI 0,75/0,5 /1,3 57/49 61/5 INTZ 04.16 DEMZ 07 1,4/,4 8 TCDV/H F400 060-4/8 tri 1500/750 DA 0,8/0, /1 57/41 61/43 INTZ 04.16 DEMZ 04 1/,4 8 TCDV/H F400 060-6/8 tri 1000/750 BI 0,55/0,14,1/1, 49/41 5/43 INTZ 04.16 DEMZ 07 1,4/,4 8 TCDV/H F400 080-4/6 tri 1500/1000 BI 1.5/0.37 3.7/1.8 66/55 68/56 INTZ 04.16 DEMZ 07,4/4 8 TCDV/H F400 080-4/8 tri 1500/750 DA 1,6/0,4 4,1/1,8 66/46 68/48 INTZ 04.16 DEMZ 04 1,8/5 8 TCDV/H F400 080-6/8 tri 1000/750 BI 0,55/0,14,1/1, 55/46 56/48 INTZ 04.16 DEMZ 07 1,4/,4 8 TCDV/H F400 105-4/6 tri 1500/1000 BI 3/1 6,8/4,1 67/56 69/59 INTZ 04.16 DEMZ 07 5/8,5 8 TCDV/H F400 105-4/8 tri 1500/750 DA,8/0,7 6,1/,4 67/48 69/51 INTZ 04.16 DEMZ 04 3,1/8,5 8 TCDV/H F400 105-6/8 tri 1000/750 BI 1,1/0,55 3,6/,5 56/48 59/51 INTZ 04.16 DEMZ 07 3,1/5 8 TCDV/H F400 110-6/8 tri 1000/750 BI 1.1/0.55 3,6/,5 64/57 67/60 INTZ 04.16 DEMZ 07 3,1/5 8 TCDV/H F400 110-6/1 tri 1000/500 DA 1,5/0,5 4,6/1,7 64/51 67/54 INTZ 04.16 DEMZ 04 1,8/5 8 TCDV/H F400 140-6/8 tri 1000/750 BI 3/0,75 8/3,8 67/60 70/63 INTZ 04.16 DEMZ 07 4/11 8 TCDV/H F400 140-6/1 tri 1000/500 DA 4/0,65 1.6/5.1 67/55 70/58 INTZ 04.16/INTZ 04.3 DEMZ 04 6,5/14 16,6 TCDV/H F400 195-6/8 tri 1000/750 BI 4/1,1 11,3/4,8 70/63 73/66 INTZ 04.16/INTZ 04.3 DEMZ 07 6,5/14 16,6 TCDV/H F400 195-6/1 tri 1000/500 DA 4/0,65 1.6/5.1 70/58 73/61 INTZ 04.16/INTZ 04.3 DEMZ 04 6,5/14 16,6 180