Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

Similar documents
MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Distributed by: M&M Control Service, Inc

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

MODEL A-100NE Peristaltic Injector Pump Operating Manual

digital flow meters BW Digi-Meter F-1000

Signet Pressure Transmitter

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

SeaMetrics Flow Meters and Flow Computers

2100 Turbine Flow Sensor

Signet Pressure Transmitter

Instructions EM 101 Low Flow Electromagnetic Flow Meters

ProSeries CHEM-PRO. Series C2F and C2V Variable Speed Positive Displacement Diaphragm Metering Pump. Built -In DFD.

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

BI-DIRECTIONAL INSERTION METER

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

Inline Ultrasonic Flowmeter

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

FLEX-PRO TM PERISTALTIC PUMPS

Model 1000 Vortex Meter

Appendix. Clearance. Skewed profiles. Application Schematics

Signet Temperature Transmitter

DTK. OEM Pelton Wheel Flow Sensor

FLEX-PRO. Peristaltic Metering Pump. SERIES A3V and A4V. Operating Manual. ProSeries. by Blue-White Ind.

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter

Time Delta S Fixed Transit-Time Flow Meter System

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

IDS INDUSTRIAL DISPENSER INSTRUCTIONS ISO SAFETY INSTRUCTIONS

RPFS. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products 41 Carter Road, Brookvale NSW 2100

Model FM1000 Series Operating Instructions. Drum Pump Flow Meter

OMP POSITIVE DISPLACEMENT FLOWMETERS

RPFS. ROTA PULSE FLOW SENSOR (Slip Insertion Paddlewheel) DATASHEET FEATURES

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

F-2700 SERIES INSERTION VORTEX FLOW METER

SIGNET Temperature Transmitter

OMP Positive Displacement Flowmeters

FLEX-PRO. ProSeries SERIES A2V. Peristaltic Metering Pump. by Blue-White Ind. Operating Manual CERTIFIED FINAL DOCUMENT

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

MODEL 106F TEFLON LIQUID FLOW SENSOR

IM SERIES BI-DIRECTIONAL INSERTION FLOWMETER. Instruction Manual. To the owner SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

SIGNET 7002 Vortex Flow Sensor ENGLISH

THIS MANUAL DESCRIBES THE SMARTCRAFT GAUGE SYSTEMS AVAILABLE FOR YOUR BOAT

RCM - Direct Reading Flowmeters

Model 5000 Vortex Meter

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Paddle-wheel flow controller for On/Off control

Low Profile Insertion Vortex

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

Paddle-wheel flow controller for On/Off control

DUALPULSE BI-DIRECTIONAL INSERTION FLOW TRANSDUCER INSTRUCTION MANUAL IMDP DUALPULSE LOCK

Signet 7000/7001 Vortex Flow Sensors * *

TABLE OF CONTENTS GENERAL INFORMATION. Read Me!

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

DPT TARGET TYPE FLOWMETERS

DIGIFLO ELECTRONIC FLOWMETER

Model TUR-200D Turbine Flowmeter

Thermoplastic. Order Online. Specialists in. Since Piping systems. fwwebb.com/plastics Flowmeters & Process Control.

INSERTION flowmeter with paddle wheel, ELEMENT design

INSERTION flow sensor for continuous flow measurement

A1 Commercial Grade Meters

PMG MAGNETIC FLOWMETER

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

PSF50 Paddle flow switch

Operating Manual Model- P282 Digiflow Controller

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Industrial OG meter series IOG Inline and flanged oval gear meter

Vortex Eggs Delta Flowmeter

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps

RUN ACCUM. TOTAL STOP BAT LOW HIGH

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

imag 4700 SERIES FLANGED MAGMETER

Low Pressure Sensor. Overview. Specifications. Installation and Operation

UTM10 Series Ultrasonic Transit-time Flowmeters

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

Model DFX Doppler ultrasonic flow meter

Switch select of sender types:

F-2700 SERIES INSERTION VORTEX FLOW METER

G2 Industrial Grade Meters

DPS280 / DVS280 Series

Series TTMP PVC Electronic Totalizing Meter

Hot Tap Insertion Vortex

Electromagnetic Flowmeters. Product Overview.

A1 Commercial Grade Meters

Signet ph/orp Transmitter

SIGNET Vortex Flow Sensors ENGLISH

FTB380 SERIES Aluminum Turbine Flowmeters

TX101/201 Insertion Turbine Instructions

+GF+ SIGNET 2550 Insertion Magmeter

DOR INSERTION PADDLE WHEEL FLOWMETER

Transcription:

Digital Paddlewheel Flow meter Operating Manual Blue-White Industries, Ltd.

Page 2 TABLE OF CONTENTS 1...Introduction...2 2...Features...3 3...Model number matrix...3 4...Specifications...4 4.1..Temperature and pressure limits...4 4.2..Dimensions...5 4.3..eplacement parts...5 5...Installation...6 5.1..Wiring connections...6 5.2..Circuit board connections...6 5.3..Flow verification output signal...6 5.4..Panel or wall mountings...7 6...Operation...7 6.1..Theory of operation...7 6.2..Control panel...8 6.3..Flow stream requirements...8 6.4..un mode display...8 6.5..un mode operation...9 6.6..Viewing the K-factor...9 7...Programming...9 7.1..Field Calibration...9 7.2..Programming for body size/range S1 - S6...1 7.3..Field calibration range setting S...11 Warranty information...12 1. Introduction The Micro-Flo flowmeter is designed to display flow rate and flow total on a six digit LCD display. The meter can measure bi-directional flows in either vertical or horizontal mounting orientation. Six flow ranges and four optional pipe and tubing connections are available. Pre-programmed calibration K-factors can be selected for the corresponding flow range or a custom field calibration can be performed for higher accuracy at a specific flow rate. The meter is factory programmed for the correct K-factor of the body size included with the meter.

Page 3 2. Features Four connection options available: 1/8 F/NPT, 1/4 F/NPT, 1/4 OD x.17 ID Tubing & 3/8 OD x 1/4 ID Tubing sizes. Six body size/flow range options available: 3 to 3 ml/min, 1 to 1 ml/min, 2 to 2 ml/min, 3 to 3 ml/min, 5 to 5 ml/min, 7 to 7 ml/min. 3 model display variations: FS = Sensor mounted display FP = Panel mounted display (includes 6 cable) FV = No display. Sensor only. 5vdc current sinking output 6 digit LCD, up to 4 decimal positions. Displays both rate of flow and total accumulated flow. Open collector alarm setpoint. User selectable or custom programmable K-factor. Flow units: Gallons, Liters, Ounces, milliliters Time units: Minutes, Hours, Days Volumetric field calibration programming system. Non-volatile programming and accumulated flow memory. Total reset function can be disabled. Clear PVC viewing lens or PVDF chemical resistant lens. Weather resistant Valox PBT enclosure. NEMA 4X 3. Model number matrix METE FUNCTION FS = Flow rate and Totalizing. On-sensor mounting FP = Flow rate and Totalizing. emote panel mounting FV = Flow sensor only (no display) POWE SUPPLY 1 = Transformer U.S. 115VAC/15VDC 2 = Transformer E.U. 22VAC/15VDC 3 = Transformer U.S. 23VAC/15VDC None = No selection (customer supplied) FLOW ANGE SELECTION 1 = 3-3 ml/min 2 = 1-1 ml/min 3 = 2-2 ml/min 4 = 3-3 ml/min 5 = 5-5 ml/min 6 = 7-7 ml/min O-ING SEAL V = Viton E = EPDM CONNECTO 4 =.25 OD tubing PVDF 5 =.125 Female NPT PVC 6 =.375 OD tubing PVDF 7 =.25 Female NPT PVC LENS MATEIAL = Clear PVC 1 = Opaque PVDF

Page 4 4. Specifications Max. Working Pressure: PVC lens, 13 psig (9 bar) @ 7 F (21 C) PVDF lens, 15 psig (1 bar) @ 7 F (21 C) Max. Fluid Temperature: PVC lens, F/NPT connectors 13 F (54 C) @ PSI PVDF lens, tubing connectors 2 F (93 C) @ PSI Full scale accuracy +/- 6% Input Power requirement: 9-28 VDC (31mA @ 15Vdc) Sensor only output cable: 3-wire shielded cable, 6ft Pulse output signal: Digital square wave (2-wire) 25ft max. Voltage high = 5Vdc, Voltage low <.25Vdc 5% duty cycle Output frequency range: 4 to 5Hz Alarm output signal: NPN Open collector. Active low above programmable rate set point. 3Vdc maximum, 5mA max load. Active low <.25Vdc 2K ohm pull up resistor required. Enclosure: NEMA type 4X, (IP56) Approximate shipping wt: 1 lb. (.45 kg) 4.1 Temperature and Pressure limits Maximum Temperature vs. Pressure 2 F (93 C) 174 F (79 C) Models with PVDF Lens and connectors TEMPEATUE 148 F (64 C) 122 F (5 C) 96 F (36 C) Models with PVC Lens or connectors 7 F (21 C) 3(2) 6(4) 9(6) 12(8) 15(1) STATIC PESSUE PSI (BA)

Page 5 4.2 Dimensions 5. in [127 mm] 1.48 in [37.71 mm] 2.22 in [56.26 mm] 3.51 in [89.3 mm] 4.3 eplacement Parts 18 13 2 16 17 19 1 14 22 9 6 7 5 4 3 2 1 21 15 8 8 PATS LIST Key Part No. Description Qty. 1 911-81 Screw 6-32x.5 Phil Flt SS 4 2 92-227 Lens Cap Clear PVC 1 92-228 Lens Cap Opaque PVDF 3 93-143 O-ing Viton 1 93-146 O-ing EP 4 92-23 Paddle PVDF 1 5 97-592 Axle PVDF 1 6 93-12 O-ing Viton 2 93-11 O-ing EP 7 761-3 Body S1 PVDF (3-3ml/min) 1 761-31 Body S2 PVDF(1-1ml/min) 761-32 Body S3 PVDF (2-2ml/min) 761-33 Body S4 PVDF (3-3ml/min) 761-34 Body S5 PVDF (5-5ml/min) 761-35 Body S6 PVDF (7-7ml/min) 8 911-113 Screw #4x.5 Phil Blk 4 9 76-137 Adapter.25 F/NPT PVC 2 76-456 Adapter.125 F/NPT PVC 92-38 Adapter.37OD x.25id Tube PVDF 92-42 Adapter.25OD x.17id Tube PVDF 1 912-252 Sensor 1 13 92-242 Enclosure, Valox 1 14 912-254 LCD display 1 15 91-26 Circuit board 1 16 96-64 Gasket, rear enclosure 1 17 92-243 Cover, enclosure rear 1 18 98-199 Liquid Tight Connector Set 1 19 911-178 Screw #4x.62 Phil SS Blk 4 2 911-177 Screw #2x.25 L Phil St 2 21 761-299 Tubing connector seal 1 22 96-65 Gasket, sensor mount seal 1

Page 6 5. Installation 5.1 Wiring Connections On sensor mounted units, the output signal wires must be installed through the back panel using a second liquid-tite connector (included). To install the connector, remove the circular knock-out. Trim the edge if required. Install the extra liquid-tite connector. On panel or wall mounted units, wiring may be installed through the enclosure bottom or through the back panel. See below. KNOCK-OUT ½ diameter Power Input ear view 5.2 Circuit Board Connections Alarm output Open Collector 3 VDC max 5mA max 2K (+) 2K ohm pull up (-) resistor required (+) (-) Pulse output Digital sq. Wave 5 VDC high <.25 VDC low 5% duty cycle Programming disable jumper (un-installed). Install on both pins to disable programming. CICUIT BOAD Front panel touch pad ribbon cable connection Power input (+ 9-28 Vdc) Power input ( ground ) Sensor input (+) ED Sensor input (signal) BAE Sensor input ( - ) BLACK 5.3 Flow Verification Output Signal When connected to external equipment such as a PLC, data logger, or Blue- White metering pump, the pulse output signal can be used as a flow verification signal. When used with Blue-White metering pumps, connect the positive (+) terminal on the Micro-Flow circuit board to the pump s yellow signal input wire and the negative (-) terminal to the black input wire.

5.4 Panel or wall mounting Page 7 Wiring through enclosure bottom for dry applications Through panel wiring for water resistant applications Panel or wall mounting screw locations 1.75 in [45 mm] ecommended panel or wall mounting cut-out for wire connection opening 1. in [25 mm] 6. Operation 6.1 Theory of operation The Micro-Flo flowmeter is designed to measure the flow rate and accumulate the total volume of a fluid. The unit contains a paddle wheel that has six (6) through holes to allow infrared light to pass through, a light-detecting circuit and a LCD-display electronic circuit. As fluid passes through the meter body, the paddle wheel spins. Each time the wheel rotates a DC square wave is output from the sensor. There are six (6) compete DC cycles induced for every revolution of the paddle wheel. The frequency of this signal is proportional to the velocity of the fluid in the conduit. The generated signal is then sent into the electronic circuit to be processed. The meter is factory programmed for the correct K-factor of the body size included with the meter. The Micro-flo flowmeter includes the following features: Displays either the flow rate or the accumulated total flow. Provides a pulse output signal that is proportional to the flow rate. Provides an open collector alarm output signal. Active low at flow rates above the user programmed value. Provides user selectable, factory preset calibration k-factors. Provides a field calibration procedure for more precise measurement. Front panel programming can be disabled by a circuit board jumper pin.

Page 8 6.2 Control Panel Enter Button (right arrow) - Press and release - Toggle between ate, Total, and Calibrate screens in the run mode. Select program screens in the program mode. Press and hold 2 seconds - Enter and exit program mode. (Automatic exit program mode after 3 seconds of no inputs). Clear/Cal (up arrow) - Press and release - Clear total in the run mode. Scroll through and Select options in the program mode. 6.3 Flow stream requirements The Micro-flo flowmeter can measure fluid flow in either direction. The meter must be mounted so that the paddle axle is in a horizontal o position - up to 1 off the horizontal is acceptable. The fluid must be capable of passing infra-red light. The fluid must be free of debris. A 15 micron filter is recommended - especially when using the smallest body size (S1), which has a.31 through hole. 6.4 un mode display Body size/range = Field calibrate 1 = 3-3 ml/min 2 = 1-1 ml/min 3 = 2-2 ml/min 4 = 3-3 ml/min 5 = 5-5 ml/min 6 = 7-7 ml/min S1 Cal SetP Min Field Calibration indicator Cal (steady) = active Cal (flashing) = calibrating none = factory cal. active Flow units indicator = Milliliters OZ = Ounces GAL = Gallons LIT = Liters Display Value Function indicator = Flow rate indicated T = Flow total indicated 6.5 un mode operation S1 S1 T Min Alarm indicator SetP (steady) = active SetP (flashing) = alarm none = not programmed ate time base indicator Min = ate per minute Hr = ate per hour Day = ate per day FLOW ATE DISPLAY - Indicates rate of flow, S1 = body size/range #1, = units displayed in milliliters, MIN = time units in minutes, = flow rate displayed. FLOW TOTAL DISPLAY - Indicates accumulated total flow, S1 = body size/range #1, = units displayed in milliliters, T = total accumulated flow displayed.

Page 9 6.6 Viewing the K-factor (pulses per unit) s1 Min While in the run mode, Press and hold then press and hold to display the K-factor. s1 181336 elease and to return to run mode. Body Size Flow ange (ml/min) Pulses per Gallon Pulses per Liter Useful formulas 6 / K = rate scale factor 1 2 3 3-3 1-1 2-2 181,336 81,59 42,51 47,99 21,535 13,752 rate scale factor x Hz = flow rate in volume per minute 4 5 6 3-3 5-5 7-7 25,153 15,737 9,375 6,646 4,157 2,477 1 / K = total scale factor total scale factor x n pulses = total volume 7. Programming The Micro-Flo flowmeter uses a K-factor to calculate the flow rate and total. The K-factor is defined as the number of pulses generated by the paddle per volume of fluid flow. Each of the six different body sizes have different operating flow ranges and different K-factors. The meter is factory programmed for the correct K-factor of the body size included with the meter. The meter s rate and total displays can be independently programmed to display units in milliliters (), ounces (OZ), gallons (GAL), or liters (LIT). ate and total can be displayed in different units of measure. The factory programming is in milliliters (). The meter s rate display can be independently programmed to display time base units in minutes (Min), Hours (Hr), or Days (Day). The factory programming is in minutes (Min). For greater accuracy at a specific flow rate, the meter can be field calibrated. This procedure will automatically over-ride the factory K-factor with the number of pulses accumulated during the calibration procedure. The factory default settings can be re-selected at any time. 7.1 Field Calibration Any body size/range can be field calibrated. Calibration will take into account your specific application s fluid properties, such as viscosity and flow rate, and increase the accuracy of the meter in your application. The Body Size/ange must be set for S to enable the calibration mode. Follow the programming instructions on pages 1 & 11 to reset the Body Size/ange and perform the calibration procedure.

Page 1 7.2 Programming for body size/ranges S1through S6 - Press and Hold to initiate the programming mode. S1 BODY SIZE/ANGE - Select your body size. Selected body size flashes. Press and release to select. S1 > S2 > S3 > S4 > S5 > S6 > S Note: Select S for field calibrating any body size range. 1 Min ATE UNIT OF MEASUE - current unit of measure setting flashes Press and release to select. > OZ > GAL > LIT 2 Min ATE DECIMAL LOCATION - current decimal display setting flashes. Press and release to select. >. >. >. >. 3 Min ATE TIME BASE - current time base unit of measure setting flashes. Press and release to select. Min > Hr > Day 1 T TOTAL UNIT OF MEASUE - current unit of measure setting flashes Press and release to select. > OZ > GAL > LIT 2 T TOTAL DECIMAL LOCATION - current decimal display setting flashes. Press and release to select. >. >. >. >. 3 ST T Y TOTAL ESET ENABLE - current Y (yes) or N (no) setting flashes. Press and release to select. Y > N 1 SetP off ALAM SETPOINT ENABLE - current ON or OFF setting flashes. Press and release to select. ON > OFF If off If on 2 ALAM SETPOINT VALUE - current value setting flashes. SetP Press and release to select the digit to change. Press and hold then press to change the selected digit. p. SetP ALAM VALUE DECIMAL LOCATION - current decimal display setting flashes. Press and release to select. >. >. >. >. If range S is selected, continue to field calibration procedure, next page. If range S1 through S6 is selected, return to program screen or press and hold to exit the programming mode.

Page 11 7.3 Field calibration size/range setting S - Continuation of programming sequence when range S is selected. The meter should be installed as intended in the application. The amount of fluid that flows through the meter during the calibration procedure must be measured at the end of the calibration procedure. Allow the meter tperate normally, in the intended application, for a period of time. A test time of at least one minute is recommended. Note - the maximum number of pulses possible is 52,. Pulses will accumulate in the display. After the test time period, Stop the flow through the meter. The pulse counter will stop. Determine the amount of fluid that passed through the meter using a graduated cylinder, scale, or other method. The measured amount must be entered in calibration screen #4 MEASUED VALUE INPUT. 1 Cal CALIBATION UN EQUEST - Current N (no) setting flashes. un n Press and release to select. Y > N Cal If yes 2 CALIBATION EADY - Zeros flash. If no Cal Press and release to start calibration counter. Start flow through the meter. Begin measuring fluid. Pulses will begin to accumulate. (CAL icon blinks). CALIBATION COMPLETE - Pulse count displayed. 3281 Stop flow through the meter. Press and release to stop calibration counter. (CAL icon stops blinking). 3 Cal 3583 VOLUME UNITS - current units setting flashes. Press and release to select units of measure used in the calibration. > OZ > GAL > LIT 4 Cal MEASUED VALUE INPUT - Input the amount of fluid measured. The selected digit blinks. Press and release to select the digit to change. Press and hold then press to change the selected digit. p Cal. MEASUED VALUE DECIMAL LOCATION - current decimal display setting flashes. Press and release to select. >. >. >. >.