Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Similar documents
Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Advance 27 ANSI 27 kv switchgear

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Solid Dielectric, Single Phase Recloser

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

Type SDV7 distribution circuit breaker family

Horizontal Circuit Switchers

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Horizontal Circuit Switchers

Solid Dielectric, Single Phase Reclosers

Type SDV7 distribution circuit breaker family Answers for energy.

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Molded Vacuum Reclosers The recloser you want, all in one package. Single- and Three-Phase Molded Vacuum Reclosers, 15 38kV

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Product Group Brochure. PS Range Capacitor Vacuum Switches

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Type IMC Indoor current transformer

OVR Three Phase Recloser 15 kv - 38 kv. Descriptive Bulletin

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Cobra-S. Catalog Cobra-S

R-MAG Medium Voltage Outdoor Dead Tank Vacuum Magnetic Circuit Breaker

Publication No.: PSG

C1000 Series Automatic Cap Bank

Type ICX Outdoor open type cutout

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Medium Voltage Metal-Enclosed Switches

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

FEBRUARY 14, 2017 Joslyn Hi-Voltage Capacitor switches customer presentation

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Padmount Solid Dielectric Switchgear Catalog

Underground Distribution Switchgear

Submersible Vacuum Fault Interrupters

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Medium voltage vacuum circuit breaker. E-VAC series

Series KTU7 UL489 Molded Case Circuit Breakers

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

AutoLink Frequently Asked Questions

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

AP/UP, AP/MIL Series Magnetic Circuit Protectors

Air-insulated switchgear UniGear type ZS1

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Medium Voltage Metal-Enclosed Switches

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

Series KTU7 UL489 Molded Case Circuit Breakers

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

solutions RUS accepted

Outdoor vacuum breaker for railway applications - FSK II

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

SWITCHGEAR DIVISION PRODUCT PROFILES

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

Q pole Pole Mounted Capacitor System

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

B kv Gas-insulated Substations

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

ABB AG - EPDS. Vacuum interrupters

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Instruction manual. Type 3AH35-MA vacuum circuit breaker magnetic-actuator operator module.

Transmission Switching

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

Underground Distribution Switchgear

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

B4 Load Break Switches

3TM Vacuum Contactors

EMPAC Metal enclosed capacitor bank for wind applications

RUS accepted Catalog O-vst18

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Power Break II Switchboard

DPX moulded case circuit breakers

209 Series. Magnetic Circuit Protectors

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Medium voltage indoor circuit breakers ANSI/IEC solutions

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

B kv T&D GAS INSULATED SWITCHGEAR

Typical Specification

Transcription:

Descriptive Bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Introduction The R-MAG is truly the next generation in medium voltage vacuum circuit breaker technology. ABB is the first to combine the unique benefits of vacuum interrupter technology with a magnetic actuator designed to exploit these capabilities. Using a flux-shifting device with integral permanent magnets, the R-MAG mechanism has only one moving part. With simple open and close coils, an electronic controller and capacitors for energy storage, the R-MAG circuit breaker mechanism is capable of 10,000 load operations. These are a few of the features that mark a departure from the conventional spring-operated mechanism, introducing new capabilities and benefits for a smarter distribution system. ABB makes safety our first priority by employing magnetic actuators to eliminate maintenance on coils, motors, and mechanically charged springs. R-MAG benefits include: Simple, less frequent maintenance Rated for 10,000 full load operations (five times ANSI requirements) No maintenance required on magnetic actuator Plug & play actuator circuitry Vacuum interrupters rated for 30,000 full load operations Increased reliability Magnetic actuator has only one moving part No spring charging motors to replace No trip/close coils to replace Less moving parts leads to less maintenance R-MAG increased performance 2,000 operations between servicing vs 500 operations between servicing - ANSI C37.06 requirements 10,000 mechanical or load operations vs 2,000 no-load mechanical operations - ANSI C37.06 requirements No maintenance required on magnetic actuator Eliminates open/close coils in stored spring mechanism lubrication requirements The R-MAG has three main components: Vacuum interrupter assembly Operating mechanism Provides reliable operation even after extended periods of inactivity Electronic control board Compatible with all forms of overcurrent, reclosing and control functions 2 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

Vacuum interrupters Manufacturing vacuum interrupters since 1980, ABB has become a worldwide leader in vacuum interrupter technology. Rated for 30,000 mechanical or load operations Up to 40 operations at maximum interrupting rating One of the largest vacuum interrupter producers in the world Environmentally friendly and maintenance-free for life ABB vacuum interrupters are used in many products globally 1 Vacuum interrupter family 2 For over 25 years, ABB has been developing and manufacturing vacuum interrupters for medium voltage applications 3 Construction of a vacuum interrupter 4 Sample of vacuum bottle curve - 15 kv - 25 ka breaker 1 2 3 4 Stems Twist protection Metal bellows End cap Bellows shield Ceramic insulator Main shield Contacts Stem End plate Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 3

Magnetic actuator ABB has utilized magnetic actuators since 1997. One global team is dedicated to designing magnetic actuators for ABB products, including R-MAG breakers. 15 kv rated at 100,000 mechanical operations 38 kv rated at 50,000 mechanical operations One moving part No maintenance required Magnet life expectancy Developments in magnetic material technology allow the magnetic actuator to be highly reliable over a long life time. Reduction in magnetic flux density is less than 1% over 100 years at 248 F (120 C). Connection to cranksfaft Coils Permanent magnets Movable armature Steel laminate housing A spring charged mechanism has over 300 total parts (many moving parts) and requires periodic maintenance. A magnetic actuator has one moving part and requires no maintenance. 4 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

All operating mechanism functions are integrated in the magnetic actuator of the R-MAG circuit breaker. The actuator is a bistable magnet system, in which armature change-of-state is accomplished by the magnetic field of two electrically excited coils. The armature is held magnetically in the limit positions by the fields of two rare-earth permanent magnets. Switching operations are achieved by excitation of one of the two coils until the retaining force of the permanent magnets is exceeded. Even after complete failure of the auxiliary power, the energy stored in the capacitors will allow electrical operation for 200 seconds. In the event of complete loss of control power, the circuit breaker can be tripped manually. The armature of the magnetic actuator is linked to an operating shaft connected via insulated push rods to each of the vacuum interrupters. Magnetic flux density distribution representation during a magnetic actuator opening operation 1 2 3 4 1 Magnetic latching in a closed position 2 Magnetic latching plus current build up in one coil 3 Armature reaching the open position 4 Final open position Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 5

Electronic control board Low power consumption electronic control board, with flexible voltage range and alarms, control the R-MAG magnetic actuator. Advantages of electronic controls Flexibility of control voltages Consistency of operation utilizing capacitor energy Built-in trip & close coil features Built-in breaker status indication Coil protection Ready and Not-Ready alarm Flexibility of control voltages Two control boards cover all control power requirements: Low voltage: 17-75 VDC or 21-52 VAC High voltage: 77-280 VDC or 85-264 VAC Control board is independent of AC or DC 1 control board covers 120 VAC, 125 VDC, 240 VAC application Ability to test a 125 VDC breaker with 120 VAC Low power requirements - 93 watt normal (41 watt power optional) Less than 1A at 125 VDC during capacitor charging (7 seconds) Plug & play removal & installation of control board assembly Easy board conversion between low and high control power requirements Eliminates changing of trip and close coils, motors Increased safety Wide range of input voltages Minimizes damage from voltage spikes or higher charging voltages 1 Electronic control board 2 Capacitors 3 Built-in breaker status indicator Consistency of operation utilizing capacitor energy Smaller battery system - can be minimal since there is no high instantaneous load on charging, closing or tripping Voltage drop is not an issue when running control power from battery system (smaller wiring can be used) Operate multiple breakers simultaneously Sufficient energy to operate multiple breakers from station batteries simultaneously Constant energy source Energy for closing and tripping is constant (regardless of station battery voltage) thus closing and opening speed are consistent Using capacitors for stored energy The 0.1 Farad Electrolytic capacitors are designed to be operated in the temperature range of -40 F to 185 F (-40 C to 85 C) Extreme temperature option also available: -67 F to 221 F (-55 C to 105 C) Recommended capacitor replacement 20 years for an average yearly temperature (in the outdoor breaker enclosure) of less than 122 F (50 C) 15 years for tropical climates Built in breaker status indication Unit-Ready and Not-Ready output contacts will provide an alarm under the following conditions: Drop off auxiliary supply voltage Low voltage on capacitor Capacitor vs number of operations Open-close-open: 78 V Close-open: 72.5 V Cannot close breaker without sufficient energy to trip Open: 49 V 1 2 3 6 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

Additional features Manual emergency trip Manual trip lever electronically interlocked to prevent closing in close block position 69 function When manually tripped, closing is electrically blocked When tripped, handle returns to the close blocked position Will not allow closing until lever is moved to normal operating position Embedded Poles in the 38 kv High dielectric strength due to solid material insulation No external influences on the vacuum interrupter (shock damage, dust, humidity) Suitable for different climatic conditions worldwide Compact and robust technology (modular structure) Maintenance-free for life Summary of R-MAG advantages ABB vacuum interrupters World s largest manufacturer of vacuum interrupters Rated for 30,000 mechanical or load operations ABB magnetic actuator Eliminates all maintenance on operating mechanism World s leader in magnetic actuation technology ABB electronic controller Plug and play removal and installation Independent of AC or DC power 5 YEAR FULL WARRANTY Manual emergency trip Embedded poles Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 7

TRIP HANDLE POSITIONS 12A01507H01 NORMAL CLOSE BLOCKED TRIP Drawings Outline drawing R-MAG 15 kv 1250 A [203.2] [304.8] 8.00 X 12.00 OPENING WITH REMOVABLE PLATE. CUSTOMER TO DRILL TO SUIT. 31.38 [796.9] CONDUIT ENTRANCE PLATE 16.00 [406.4] [838.2] 33.00 DOOR SWING R-MAG 42.75 [1085.9] 3.62 [92] 15.563 [395] FOUNDATION PLAN 17.00 [431.8] PROVISION FOR.750 DIA. HDW. [19] [838.2] 33.00 DOOR SWING 6 4 2 5 3 1 16.00 [406.4] SEE NOTES 2 & 3 SEE NOTE 2 36.00 [914.4] 8.500 [215.9] TYP PROVISIONS EACH END FOR LIFTING (2.00 DIA. HOLES) 47.25 [1200.2] 5 3 1 13.00 [330.2] TYP 105.81 [2687.6] 87.81 [2230.4] 18.00 [457.2] 16.44 [417.5] 30 50 C L C.G. MANUAL TRIP SWING ANGLE KEEP CLEAR GROUND PAD FARSIDE 6.000 [152] MANUAL TRIP 70.625 [1794.9] MAX. 78.125 [1984.3] MAX. 3.000 [76.2] GROUND PAD MANUAL TRIP R-MAG C L C.G. WINDOW FOR COUNTER AND POSITION IND. FAR SIDE DOOR TO CONTROL COMPARTMENT 36.25 [920.8] [76.2] 3.000 INCREMENTS FOR ADJUSTMENT 31.38 [796.9] NOTES: 1. ALL DIMENSIONS IN [ ] BRACKETS ARE MILLIMETERS. 2. 30.00 [762] CLEARENCE ABOVE ROOF REQUIRED TO REMOVE BUSHINGS. 3. 15KV 1250A = 17.50 [444.50] STD CREEP, 28.33 [720] EXTRA CREEP 4. MAX WEIGHT: 1700 LBS [771] KG. 5. SEISMIC RATING = 0.5g PER IEEE STD 693.875 DIA. [22.2] 42.75 [1085.9] [38.1] 1.500 4.000 [101.6] [101.6] 4.000 1.500 [38.1] 8 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

TRIP HANDLE POSITIONS 12A01507H01 NORMAL CLOSE BLOCKED TRIP Outline drawing R-MAG 15 kv 2000/3000/3700 A 27 kv 1250/2000 A 8.00 [203] X 12.00 [305] OPENING WITH REMOVABLE PLATE. CUSTOMER TO DRILL TO SUIT 40.69 [1033] CONDUIT ENTERENCE PLATE 21.50 [546] 4.58 [116] 56.31 [1430] 6 4 2 22.16 [563] 5 3 1 FOUNDATION PLAN 1.00 [ 25] FOR.750 [19] DIA MOUNTING BOLT 26.500 [673] 51.308 [1303] 44.704 [1135] Ø2.00 PROVISION EACH END FOR LIFTING SEE NOTE 2 AIR VENT USED ON 15KV, 3000A AND 27KV 2000A 9.602 [244] 9.602 [244] 16.000 [406] 60.202 [1529] 16.000 [406] SEE NOTES 2 & 3 91.06 [2313] 50 C L C L MANUAL TRIP MANUAL TRIP C L C.G. 109.06 [2770] 30 MANUAL TRIP SWING ANGLE KEEP CLEAR GROUND PAD FARSIDE GROUND PAD GROUND PADS 6.00 [152] 66.625 [1692.3] MAX. 78.312 [1989] MAX. 16.44 [418] R-MAG DOORS TO CONTROL COMPARTMENT 1.75 [44] TYP WINDOW FOR COUNTER AND POSITION IND. (FAR SIDE) 9.13 [232] 40.69 [1033] 56.31 [1430] 18.00 [457] 3.00 [76] INCREMENTS FOR ADJUSTMENT 1.500 [38] 4.000 [102] NOTES: 1. ALL DIMENSIONS IN [ ] BRACKETS ARE MILLIMETERS. 2. 30.00 [762] CLEARENCE REQUIRED TO REMOVE BUSHINGS. 3. 15KV 2000A = 27.50 [698.50] EXTRA CREEP IS STANDARD 15KV 3000A = 18.30 [464.82] STD CREEP, EXTRA CREEP CONTACT SALES 27KV 1250A = 27.50 [698.50] STD CREEP, 32.50 [825.50] EXTRA CREEP 27KV 2000A = 27.50 [698.50] STD CREEP, EXTRA CREEP CONTACT SALES 4. WEIGHT: 2400 LBS [1088.6] KG. (15KV, 2000/3000A) 1900 LBS [860.9] KG. (27KV, 1200/2000A) 5. SEISMIC RATING = 0.5g PER IEEE STD 693 4.00 [102] 1.50 [38] Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 9

Outline drawing R-MAG 27 kv 1250/2000 A (reduced footprint) 8.0 X 12.0 FLOOR OPENING 24.0 47.9 4X 1.0 85.8 20.3 8.6 40.7 R22 R22 4X 105 R22 R22 43 5 20.6 10.3 52.3 16.0 16.0 MANUAL TRIP AND LOCKOUT HANDLE 3.5 1.9 POSITION INDICATOR/ OPERATIONS COUNTER 35 GROUND PAD 109.1 123.6 MAX HEIGHT 3.0 INCREMENTS FOR HEIGHT ADJUSTMENT 41.3 34.4 REAR 12.3 2X.56 2.0 1.0 1.75 NOTES: 1. ALL DIMENSIONS IN [ ] BRACKETS ARE MILLIMETERS. 2. 30.00 [762] CLEARANCE ABOVE ROOF REQUIRED TO REMOVE BUSHINGS 3. 27KV 1250A = 27.50 [698.50] STD CREEP, 32.50 [825.50] EXTRA CREEP 4. 27KV 2000A = 27.50 [698.50] STD CREEP, EXTRA CREEP CONTACT SALES 5. WEIGHT: 1430 LBS [648.64 KG] WITHOUT ELECTRONICS, WIRING, OR CTs 10 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

4 Outline drawing R-MAG 38 kv 1250 A [203.2] [304.8] 8.00 X 12.00 OPENING WITH REMOVABLE PLATE. CUSTOMER TO DRILL TO SUIT. 52.25 [1327.2] 28.19 [715] 17.25 [438] REAR OF CABINET 4.13 [105.0] 1 3 5 6.24 [158.4] 25.59 [650.1] 63.19 [1604.9] 2 4 6 OUTLINE OF CABINET FOUNDATION PLAN PROVISION FOR.750 DIA. HDW. [19] 23.00 [584] 22.50 [571] 56.50 [1435.1] 10.89 [276.5] 10.89 [276.5] PROVISION EACH END FOR LIFTING (2.00 DIA. HOLES) 67.62 [1717.5] 21.14 [537] TYP 20.13 [511.2] 3.000 [76.2] 4.44 [112.7] 81.50 [2070.1] 131.63 [3343.4] MANUAL TRIP 22.81 [579.4] GROUND PAD 30.00 [762.0] * 34.44 [874.7] DOORS TO CONTROL COMPARTMENT USE BRACES WHEN LEGS ARE FULLY EXTENDED * 3.000 VERTICAL HOLE SPACING FOR ADJUSTMENT 52.25 [1327.2] NOTES: 1. ALL DIMENSIONS IN [ ] BRACKETS ARE MILLIMETERS. 2. 47.00 [1193.8] CLEARENCE ABOVE ROOF REQUIRED TO REMOVE BUSHINGS 3. MIN. WEIGHT: 2400 LBS [1089] KG. 4. SEISMIC RATING "HIGH" PER IEEE STD 693. (EXCEEDS ZONE 4) 5. 38KV 1250A = 37.00 [939.80] STD CREEP 63.19 [1605.0].875 DIA. [22.2] [38.1] 1.500 4.000 [101.6] 1.500 [38.1] Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 11

4 Outline drawing R-MAG 38 kv 2000 A [203.2] [304.8] 8.00 X 12.00 OPENING WITH REMOVABLE PLATE. CUSTOMER TO DRILL TO SUIT. 52.25 [1327.2] 28.19 [715] 17.25 [438] REAR OF CABINET 4.13 [105.0] 1 3 5 6.24 [158.4] 25.59 [650.1] 63.19 [1604.9] 2 4 6 OUTLINE OF CABINET FOUNDATION PLAN PROVISION FOR.750 DIA. HDW. [19] 23.00 [584] 22.50 [571] 56.50 [1435.1] 10.94 [277.9] 10.94 [277.9] PROVISION EACH END FOR LIFTING (2.00 DIA. HOLES) 67.62 [1717.5] 21.28 [540.5] TYP 21.31 [541.3] 5 3 1 132.81 [3373.4] 3.000 [76.2] 4.44 [112.7] 81.50 [2070.1] MANUAL TRIP 22.81 [579.4] GROUND PAD 30.00 [762.0] * 34.44 [874.7] DOORS TO CONTROL COMPARTMENT USE BRACES WHEN LEGS ARE FULLY EXTENDED * 3.000 VERTICAL HOLE SPACING FOR ADJUSTMENT 52.25 [1327.2] NOTES: 1. ALL DIMENSIONS IN [ ] BRACKETS ARE MILLIMETERS. 2. 47.00 [1193.8] CLEARENCE ABOVE ROOF REQUIRED TO REMOVE BUSHINGS. 3. MIN. WEIGHT: 2400 LBS [1089] KG. 4. SEISMIC RATING "HIGH" PER IEEE STD 693. (EXCEEDS ZONE 4) 5. 38KV 2000A = 37.00 [939.80] STD CREEP 63.19 [1605.0].875 DIA. [22.2] [38.1] 1.500 4.000 [101.6] 1.500 [38.1] 12 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 13

Order aid Digit # 1, 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Style Number MB 1 1 1 3 6 G G M H 5 K Z C N Type R-MAG * Voltage 15.5 kv 1 27 kv 2 38 kv 3 Bil 110 kv 1 125 kv (27 kv only) 2 150 kv (27 kv only) 5 200 kv (38 kv only) 0 Continuous Current 1250A 1 2000A 2 3000A OA (15kV R-Mag breaker only) 4 3700A FA (15kV R-Mag breaker only) 5 600A 6 1600A 7 800A 8 Interrupting Rating 12.5 ka 1 16 ka 2 20 ka 3 25 ka 4 31.5 ka (38 kv only) 5 40 ka (38 kv only) 6 Auxiliary Switches One 16 Deck Switch (8a + 8b) 6 One 20 Deck Switch (10a + 10b) 0 Two 16 Deck Switches (16a + 16b) D Current Transformers 1-3-5 Ratio Accur Thermal rating factor 1 Set 2 Sets Notes: Also available in CSA and 50 HZ ratings 600/5 C100 TR 1.33 A B A B 1200/5 C200 TR 2.00 C D C D 1200/5 C200 TR 1.33 E F E F 1200/5 C400 TR 1.33 G H G H 1200/5 C200 TR 2.00 N/A I Two sets of CTs I 1200/5 C400 2000/5 C400 TR 1.33 J K J K 14 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

Digit # 1, 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Style Number MB 1 1 1 3 6 G G M H 5 K Z N S Current Transformers 1-3-5 Ratio Accur Thermal rating factor 1 Set 2 Sets Notes 1200/5 C400 TR 2.00 L M L M 1200/5 C400 TR 2.00 N/A O Two sets of CTs O 2000/5 C400 3000/5 C400 TR 1.33 P Q P Q 1200/5 C400 TR 1.50 R S R S 2000/5 C400 TR 2.00 T U T U 2000/5 C800 TR 2.00 V W V W 600/5 C200 TR 2.00 X N/A X 600/5 C400 TR 2.00 Y N/A Y SPECIAL Z NONE N Current Transformers 2-4-6 Same selection available as 1-3-5 G R-MAG Enclosure Mild steel M Stainless steel S Mild steel (27 kv reduced footprint) R Stainless steel (27 kv reduced footprint) T Control Voltage, R-Mag Actuator Control Low Voltage Actuator Controller (20.4-52.8VAC or 16.8-75VDC) L High Voltage Actuator Controller (85-264VAC or 77-280 VDC) H Auxiliary Power 120VAC (must use high voltage actuator controller) 1 240VAC (must use high voltage actuator controller) 2 48VDC (must use low voltage actuator controller) 4 125VDC (must use high voltage actuator controller) 5 Circuit Protection Molded case circuit breaker (MCB s) A Knife Switch K Pullout Fuse Block P Standard (MCB for HTR and AUX, knife SW for control) S Special Z Control Basic (no relay on breaker) B Microprocesser M Panel Configuration Std ctrl switch, open/close ind lights, and Local/Remote toggle switch L Panel with standard control switch and open/close indicating lights S Special Z No Panel N Bushing Terminal Clamp C 4 Hole NEMA Pad 4 Threaded Stud Only S Special Z * Not all combinations of options are available for all ratings. Please consult your ABB sales representative for more information. Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15

Technical data Units 1250 1250/ Rated Maximum Voltage kv 15.5 27 38 Continuous Current A 800/1250 800/1250/ 800/1250/2000/ 1250/ 1250/ 1250/ 2000 3000 1 /3700 2 2000 2000 2000 2000 Operating temperature -50 C and 70 C per IEC 62271-100 3 Voltage Range Factor K 1 1 1 1 1 1 1 1 Short Circuit Interrupting Current (at Contact ka 12.5 20 25 12.5 20 25 31.5 40 Part) ka, RMS, Sym Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60 Power Frequency Withstand Dry 60 Hz for 1 Min kv 50 50 50 60 60 60 80 80 Power Frequency Withstand Wet 60 Hz for 10 kv 45 45 45 50 50 50 75 75 Sec Lightning Impulse Withstand (BIL) kv 110 110 110 125/150 125/150 125/150 200 200 Chopped Wave Withstand (kv peak) kv 142 142 142 194 194 194 258 - Operating Duty (Standard Duty Cycle) cycles Exceeds ANSI standard O-0.3 sec-co-3 min-co Maximum Interrupting Time cycles 3 3 3 3 3 3 3 3.5 Permissible Tripping Delay Y sec 2 2 2 2 2 2 2 2 Closing Time cycles 6 6 6 6 6 6 6 6 Reclosing Time sec 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 Short Circuit Interrupting Current ka 12.5 20 25 12.5 20 25 31.5 40 (at Contact Part) ka, RMS, Sym Close & Latch (Initial Current Loop) ka 20 32 40 20 32 40 50.4 - ka, RMS, Asym Close & Latch (ka Peak) ka 32.5 52 65 32.5 52 65 81.9 104 Short Time Current (3 Sec) ka, RMS, Sym ka 12.5 20 25 12.5 20 25 31.5 40 Rated Duration of Short-Circuit @ sec 3 3 3 3 3 3 2 2 Short-Time Current Transient Recovery Voltage (kv Peak) kv 29 29 29 51 51 51 71.7 71.7 Load Current Switching Capability A 600/800 1250 600/800/ 1250/2000 600/800/1250/ 2000/3000 1250 1250/ 2000 1250/ 2000 1250/ 2000 1250/ 2000 Wire Line Charging Current A 100 100 100 100 100 100 100 100 Isolated Cable Charging Current A 600 600 600 400 400 400 600 100 Isolated Capacitor Bank Switching Current (A A 600 600 600 600 600 600 600 - RMS) Back-to-Back Shunt Capacitor Bank A 600 600 600 600 600 600 600 - Switching Current (A RMS) Transient Overvoltage Factor C1* C1* C1* C1* - Transient Inrush Current (ka Peak) Back-to-Back ka 20 20 20 20 20 20 20 - Transient Inrush Frequency (Hz) Back-to-Back Hz 4240 4240 4240 4240 4240 4240 4240 - Grounding of System and Capacitor Bank Grounded or Ungrounded System Capacitor Bank Grounded or Ungrounded Mechanical Life (No Load Operations) 10000 10000 10000 10000 10000 10000 10000 10000 Note: Please find specific R-MAG breaker vacuum bottle curves on the product instruction book. 1 up to 3000 A standard breaker 2 3700 A forced air cooled breaker 3 above 40 C breaker derated per ANSI C37.010 * Per C37.09a restrike category R-MAG Interrupter life rated for 30,000 operations when interrupting loads areless than 1 ka. For interrupting loads greater than 1 ka, consult interrupter life curves on page 3. For 125 kv BIL full-wave rating only 16 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

Options ABB test switches As the original FT switch manufacturer with the longest, most successful history, ABB Flexitest s unmatched quality is the benchmark for the industry. With more than 50 years of experience, we are the test switch manufacturer with the largest installed base in North America. ABB s Flexitest test switch s perfected design offers the highest quality, leaving nothing to chance. You can t afford less than perfect. ABB Flexitest is the original FT - there is no equivalent. Relion 615 series The Relion product family offers the widest range of products for the protection, control, measurement and supervision of power systems. To ensure interoperable and future-proof solutions, Relion products have been designed to implement the core values of the IEC 61850 standard. You can benefit from ABB s leading-edge technology, global application knowledge and experienced support network Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 17

Notes 18 R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker Descriptive bulletin

Descriptive bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 19

Contact us ABB Inc. 655 Century Point Lake Mary, FL 32746 Phone: +1 407-732-2000 ext. 2510 +1 800-929-7947 ext. 5 Fax: +1 407-732-2359 www.abb.com/mediumvoltage The information contained in this document is for general information purposes only. While ABB strives to keep the information up to date and correct, it makes no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the information, products, services, or related graphics contained in the document for any purpose. Any reliance placed on such information is therefore strictly at your own risk. ABB reserves the right to discontinue any product or service at any time. Copyright 2014, 2017 ABB. All rights reserved. 1VAL255101-DB Feb. 2017 Rev M (replaces DB38-921M)