TI23 Pre-Instructional Survey

Similar documents
Basics of Control Components

Electric Motor Controls BOMA Pre-Quiz

Basic Electricity. Mike Koch Lead Mentor Muncie Delaware Robotics Team 1720 PhyXTGears. and Electronics. for FRC

C capacitance, 91 capacitors, codes for, 283 coupling, polarized and nonpolarized,

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

SL Series Application Notes. SL Series - Application Notes. General Application Notes. Wire Gage & Distance to Load

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

MOTORTRONICS Solid State AC Motor Control

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

TPM/GMT Panel Installation Guide

WARRANTY INFORMATION...

Manual Installation & Operation

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

High Frequency SineWave Guardian TM

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

OTEC Transfer switch open transition

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

BAPI-Stat 3 Room Sensor

Q&A FOR Webinar on Electrical Basics & Boiler Wiring

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

3143 Production Drive Fairfeild, Ohio Model HA-45. Installation and Service Manual

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

Model 930 Power Control System Instruction Manual

Programmable Logic Controller. Mat Nor Mohamad

CD3000S-1PH Thyristor Unit Heater Break version

GMT Fuse Panel Installation Guide

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

Troubleshooting Bosch Proportional Valves

PKP Prozessmesstechnik GmbH Borsigstraße 24 D Wiesbaden-Nordenstadt Tel.: ++49-(0) Fax: ++49-(0)

Application Engineering

KD LV Motor Protection Relay

ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc.

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

AIR COOLED RECTIFIER SPECIFICATION S-50-A

IAE-101: Electrical Fundamentals for Non-Electrical Personnel

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Pressure Makeup Jockey Pump Controller

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

Electronic timers CT-S range Function diagrams

MODEL 422 Submersible Pump Controller

Ch 4 Motor Control Devices

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

3143 Production Drive Fairfeild, Ohio Model HA Installation and Service Manual

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Compliance with CE Marking and UL Standard

ANALOG CONTROL PANEL

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

Euclid Full Voltage Magnet Controller

Table of Contents. For latest version, visit:

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

AA4006 Speed Sensitive Trip Unit. User Manual

Transfer switch GTEC open or delayed transition

XLM 62V Energy Storage Module

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Application Engineering

INVERTER FOR DC CRANE CABIN AIR CONDITIONING UNIT 3KW VERSION

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Electrical Wiring Practices

Horizontal Circuit Switchers

18.5. Electrical Circuits and Safety

Horizontal Circuit Switchers

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

SD Series Non-Fused Load Switches

PRODUCT SERIES: DPG-2100

CHAPTER 19 DC Circuits Units

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

PBA Series Prelube Controls

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Industrial Mechanic (Millwright) Level 3

Solar PV Standard Electrical Plan

MAPNET II Transceiver Installation Instructions

1100 Series Piston Type Differential Pressure Gauges

ELECTRICAL TECHNOLOGY 3 March 2008

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

XENON POWER SUPPLY 2000 Watt

Control Relays Overview

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Installation Instructions

Electrical Circuits W.S.

Filtered PWM Speed Control for Permanent Magnet DC Motors

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Fincor Series 2230 MKII/2240

Model 550 Series Vibration Switches

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Transcription:

TI23 Pre-Instructional Survey Name: Date: 1. Identify the balloon contents that represent the relationship between the three electrical measurements as they relate to Ohm s Law. 2. Which of the statements listed is correct for the measurement of resistance? A. Resistance is measured in parallel with the circuit deenergized. B. Resistance is measured in series with the circuit energized. C. Resistance is measured in parallel with the circuit deenergized and the device being measured isolated. D. Resistance may be measured in series or parallel as long as the circuit is energized. 3. Which of the listed designations is correct for the National Electrical Code? A. NFPA 77 B. NFPA 70E C. NFPA 79 D. NFPA 70 4. Purging of enclosures in hazardous areas is cover in A. NFPA 70 B. NFPA 496 C. NFPA 214 D. NFPA 85 TI23 (V1.0) 1

5. Identify the symbol shown below. A. Earth Ground B. Shield Ground C. Circuit Common D. Chassis Ground 6. Solve for the indicated parameters for the circuit shown below. R1 2K R2 2K R3 5K R4 2K R5 4K 110 VDC R7 100K R6 7K A. Total Resistance B. Total Current C. Voltage drop across R1 D. Voltage drop across R4 E. Voltage drop across R6 7. Which of the listed switch types uses a light source to verify the presents or absence of an object? A. Microswitch B. Pushbuttons C. Reed Switch D. Proximity Switch TI23 (V1.0) 2

8. What is the total capacitance of the circuit shown below? 85 Vdc 5 pf 5 pf 5 pf A. 1.67 pf B. 16.7 µf C. 15.0 pf D. 15.0 µf 9. Which statement is not true about standard electrical service fuses? A. Some fuses are referred to as one-time fuses. B. Some fuses are referred to as time-delay fuses. C. Some fuses are referred to as over-potential fuses. D. Some fuses are referred to as current limiting non-time delay fuses. 10. Which of the listed solder types is the most frequently used for small electronic and wiring applications? A. 65/35 B. 37/67 C. 50/50 D. 63/37 11. What type of circuit break protection should be used for motor control? A. Non-automatic circuit interruptor B. Thermal C. Magnetic D. Thermal and Magnetic 12. The three phase power feeds from the power buss are labeled (consider motor control) A. L1, L2, L3 B. F1, F2, F3 C. T1, T2, T3 D. P1, P2, P3 TI23 (V1.0) 3

13. What is the RMS voltage for a power system that has a peak-to-peak voltage of 1358 Volts 60 Hertz? A. 169 Volts B. 480 Volts C. 240 Volts D. 339 Volts 14. The phase difference between each phase in a 3-phase system is? A. 180 degrees B. 120 degrees C. 270 degrees D. 90 degrees 15. Which of the wire gauges listed (AWG) has the most resistance per 1000 Feet? A. #26 B. #20 C. #14 D. #10 16. Contact blocks are found on which of the listed devices? A. Microswitch B. Pushbuttons C. Reed Switch D. Proximity Switch 17. Identify the symbol shown below. A. Normally closed held open temperature switch B. Normally open temperature switch C. Normally open held closed temperature switch D. Normally closed temperature switch TI23 (V1.0) 4

18. Identify the symbol shown below. A. Normally closed held open pressure switch B. Normally open pressure switch C. Normally open held closed pressure switch D. Normally closed pressure switch 19. Identify the symbol shown below. A. Earth Ground B. Shield Ground C. Circuit Common D. Chassis Ground 20. Identify the terminals on the switch shown below. The position is not important at this point in the course. (correct terminology) A. B. C. TI23 (V1.0) 5

21. Using the circuit shown solve for the indicated values and place your answer in the blank space to its right. 500 ohms R1 85 VDC 250 ohms R2 100 ohms R3 A. Total Resistance B. Total Current C. Voltage drop across R1 D. Voltage drop across R2 E. Voltage drop across R3 22. Identify the symbol shown below. A. Normally closed timed open timer contact B. Normally open timed closed timer contact C. Normally open timed open timer contact D. Normally closed timed closed timer contact 23. The current carrying capacity of electrical wiring is known as. 24. A specially designed switch used specifically to decouple electrical power from the system is called a/an. 25. A is a device that can be locked in place by one control signal and can not be unlocked until a second control signal is initiated. TI23 (V1.0) 6

26. The condition where radio frequency interference and/or electromagnetic interference is present is called A. An electrical anomaly B. Electrical Noise C. Electrical Inteference D. Signal Propagation 27. A device that is used to keep track of the number of times an event takes place is referred to as A. Event Controller B. Counter C. Timer D. Event Tracker 28. Which statement is true for the symbol shown below? A. An off-delay timer contact that will close when it times out. B. An off-delay timer contact that will open when it times out. C. An off-delay timer contact that will close when its preset is reached. D. An on-delay timer that will open when its preset is reached. 29. The most used troubleshooting strategy used by the control system technician is A. Input/Output B. Logical Analysis C. Substitution D. Fault Insertion 30. The connection point for electrically wired controls is referred to as a A. Junction B. Termination C. Intersection D. Contact TI23 (V1.0) 7

31. A is that part of the device being used to complete or interrupt electrical logic circuits after a predetermined amount of time has elapsed. A. Circuit Interruptor B. Counter Contact C. Relay Contact D. Timer Contact 32. The terminology used to identify the opening and closing of a relay contact is known as A. Opening and Closing B. Energizing and Deenergizing C. Making and Breaking D. Blocking and Passing 33. Identify the symbol shown below. A. A float style level switch that is normally closed. B. A float style level switch that is normally open held closed. C. A float style level switch that is normally closed held open. D. A float style level switch that is normally open. 34. Identify the symbol shown below. A. A flow switch that is normally closed. B. A flow switch that is normally open. C. A flow switch that is normally closed held open. D. A flow switch that is normally open held closed. TI23 (V1.0) 8

35. Identify the logic gate depicted by the relay ladder logic shown below. H N 1CR-1 2CR-1 1 3 8 6 P1 PL-1 P2 3 4 SW-1 3 4 SW-2 7 1 CR 2 7 2 CR 2 A. AND B. NAND C. NOT D. OR 36. Identify the electrical logic circuit shown below. H N 1 1CR-1 3 2CR-1 1 4 P1 PL-1 P2 1CR-2 2CR-2 8 5 8 6 3 4 SW-1 7 1 CR 2 3 SW-2 4 7 2 CR 2 A. The Exclusive NOR. B. The Inclusive NOR. C. The Exclusive OR. D. The Inclusive OR. TI23 (V1.0) 9

37. Label the terminal numbers indicated by the circles for the eleven-pin relay and block. 38. Label the terminal numbers indicated by the solid circles for the eight-pin relay and block. TI23 (V1.0) 10

39. Identify the points as indicated for loop #508 by the arrows in the drawing below. The control valve is a single port globe valve. A. B. C. D. E. F. TI23 (V1.0) 11

40. Identify the valve configuration shown below. A. Retentive Fail Open B. Energize to close Fail Open C. Energize to open Fail Closed D. Retentive Fail Closed TI23 (V1.0) 12

Pre-Instructional Answers 2. C 3. D 4. B 5. C 6. A. 110 K ohms B. 0.001 amps C. 3 volts D. 7 volts E. 100 volts 7. D 8. C 9. C 10. D 11. D 12. A 13. B 14. B 15. A 16. D 17. D 18. C 19. D 20. A. Common B. Norm. Open C. Norm. Closed 21. A. 850 ohms B. 0.1 amps C. 50 volts D. 25 volts E. 10 volts 22. A 23. Ampacity 24. Disconnect 25. Latching Relay 26. B 27. B 28. B 29. A 30. B 31. D 32. C 33. D 34. C 35. A 36. C 37. 38. 39. A. FV-508 B. ATC/FO C. EY-508 D. Common Port E. Norm. Open Port F. Norm. Closed Port 40. C TI23 (V1.0) 1