Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Similar documents
UL/CSA Non-fused Disconnect Switches

UL Enclosed Disconnect Switches (Fused and Non-Fused)

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Big performance in a small package

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

Rotary Disconnect Switches, Bulletin 194R

Big performance in a small package

194R J S TY N1

Big performance in a small package

Big performance in a small package

Big performance in a small package

Product Specification Sheet #3LD2.1

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Control and Load Switch Specifications Bulletin Number 194E, 194L

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Selection Guide. Control Circuit and Load Protection

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

FUSIBLE DISCONNECT SWITCHES

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

for Non-Fusible Disconnect Switches

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Enclosed Rotary Switch Product Specification Sheets Table of Contents

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Section Contents. Disconnect Switches

Load Break Disconnect Switches FSLBS

Contents. Volume 5 Motor Control and Protection CA E December

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

SPEEDFAX TM 2011 Disconnect Switches Contents

for Non-Fusible Disconnect Switches

1489-M Circuit Breakers

MS General Information Extended Product Type: MS

Bulletin 190-M Compact Starters. Selection Guide

A302DN.40/.63A Thermal Current Motor Starter

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Selection Guide Motor Control Device Solutions

Bulletin 193-T1 Bimetallic Overload Relays

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES

Technical Information

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

AF40... AF96 3-pole contactors Technical data

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -

Bulletin 1489 Circuit Breakers. Selection Guide

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

UL 98 Fusible Disconnect Switches

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Disconnect switches Non-fusible Fusible Enclosed

Compact Circuit Protector

Just the right switch for your application

Compact Circuit Protector

Product Selection 3-Pole Contactors

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

footprint of traditional fusible switches

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Fuse holders and fuses

Compact Circuit Protector (CCP)

Application Mini Contactors for Motors and Resistive Loads

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

SD Series Non-Fused Load Switches

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Control Circuit Protection

Overview for Fusible Disconnect Switches

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Bulletin 140M Motor Protectors

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Transcription:

Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Rated Current [A] Maximum Hp Ratings (1) * 1-Phase (60 Hz) 3-Phase (60 Hz) DC 120V 240V 240V 480V 600V 125V 250V UL Class CC and CSA HRCI-MISC Fuses (1) Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. (2) Integral terminal lug #12 #10 Solid Cu or #12 - #1 Stranded Cu. Fuse Dim. Ref. Cat. No. 30 2 3 7.5 15 20 3 5 30 A CC, HRCI-Misc A1 194R-C30-1753 UL Class J and CSA HRCI-J Fuses 30 2 3 7.5 15 20 3 5 30 A Class J, HRCI-J A1 194R-J30-1753 60 3 10 15 30 50 5 10 60 A Class J, HRCI-J B1 194R-J60-1753 CSA HRCII-C Fuses 30 2 3 7.5 15 20 3 5 30A HRCII-C B1 194R-H30-1753 60 3 10 15 30 50 5 10 60A HRCII-C B1 194R-H60-1753 UL Class J and CSA HRCI-J Fuses 30 2 3 7.5 15 20 3 5 30 A Class J, HRCI-J A1 194R-J30-1753 60 3 10 15 30 50 5 10 60 A Class J, HRCI-J B1 194R-J60-1753 100 7-1/2 15 30 60 75 7.5 20 100 A Class J, HRCI-J F5 194R-J100-1753 (2) 200 25 60 125 150 15 40 200 A Class J, HRCI-J F6 194R-J200-1753 400 50 125 520 350 20 50 400 A Class J, HRCI-J F7 194R-J400-1753 600 200 500 500 600 A Class J, HRCI-J F8 194R-J600-1753 UL Class L and CSA HRCI-L Fuses 800 200 500 500 800 A Class L, HRCI-L F9 194R-L800-1753 Rockwell Automation Publication 194R-SG003E-EN-P - February 2016 7

Overview Bulletin 194R Overview Bulletin 194R-C, J, H, B, D, F, L, N, NU Bulletin 194R-NE Product Type Fused and non-fused rotary disconnect switches Non-fused IEC rotary disconnect switches Current Range 20 1200 A 100 1250 A Main Applications UL 98 ratings "suitable as service entrance disconnecting means" UL 508, CSA ratings "suitable as at-motor disconnect" UL and IEC applications Functionality 3- or 4-pole fusible or non-fusible disconnect for standard OFF-ON or emergency stop in a main panel disconnect application 4th pole available as modular accessory Test mode switch position Disconnecting means IEC applications 3- or 4-pole non-fusible disconnect for standard OFF-ON or emergency stop in a main panel disconnect application 4th pole available as modular accessory Test mode switch position Mounting Styles 20 63 A: DIN Rail/Panel mounting; 100 1250 A: Panel mounting Panel mounting Handles Available in rotary styles, UL Type 1/3R/4/4X/12, IP66, standard, or test mode versions Handle colors in black and red/yellow and padlockable versions 30 A/60 A legend markers (optional) uses Cat. No. 1492-MS6X12 markers Open Switch or Enclosed Open switch Enclosed: UL/CSA rated enclosure for 20 63 A devices Available in rotary styles, UL Type 1/3R/4/4X/12, IP66, or standard versions Handle colors in black and red/yellow and padlockable versions Open switch UL/CSA Electrical Ratings: Rated Voltage U e 690V AC 690V AC Rated Current I e 20 1200 A 100 1250 A Rated Power P e [FLA] Varies w/ 1- or 3-phase switch, voltage Varies w/ 1- or 3-phase switch, voltage Short-Circuit Ratings 200 ka 200 ka Mechanical Life [ops] 10 000 10 000 IEC Rated Current I e AC-1 20 1200 A @ 690V 100 1250 A @ 690V AC-21A Varies w/ 1- or 3-phase switch, voltage Varies w/ 1- or 3-phase switch, voltage AC-22A Varies w/ 1- or 3-phase switch, voltage Varies w/ 1- or 3-phase switch, voltage Ambient Operational Temp. -20 +60 C (-4 +140 F) -20 +60 C (-4 +140 F) Ambient Enclosed Temp. -20 +60 C (-4 +140 F) -20 +60 C (-4 +140 F) Ambient Storage Temp. -40 +65 C (-40 +149 F) -40 +65 C (-40 +149 F) Protection class per IEC 529 Switch bodies: IP2 Switch bodies: IP2 Fuse carriers: IP30 Optional Accessories Operator handles Multi-length shafts Auxiliary contacts Terminal covers NFPA 79 internal handle with shaft IP66 handles Multi-length shafts Auxiliary contacts Te r m i n a l c o v e r s NFPA 79 internal handle Rockwell Automation Publication 194R-SG003E-EN-P - February 2016 3

Overview Standards Compliance and Certifications Bulletin 194R-C, J, H, B, D, F, L, N, NU Standards Compliance UL 98 UL 508 CSA C22.2, No. 14 IEC/EN 60947-3 Low Voltage Switchgear and Controlgear part 3 BS EN60947-3 VDE 0660 NEMA KS-1 Certifications CE Marked CSA Certified (File No. LR1234) UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) Standards Compliance and Certifications Bulletin 194R-NE Standards Compliance IEC/EN 60947-3 Low Voltage Switchgear and Controlgear part 3 Certifications CE Marked Product Overview The Bulletin 194R line of fused and non-fused rotary disconnect switches provides the flexibility to meet worldwide applications. The disconnect switches are UL Listed and CSA Certified and are designed to meet IEC 60947-3, VDE, DIN, BS and applicable NEMA requirements. Features 20 A 1250 A Sizes Fused switch versions: BS88 -DIN CSA HRCII-C - CSA HRCI-MISC - HRC-L UL Class J- UL Class CC - UL Class L NFC Operating handle ingress ratings: IP42 (Type 1) IP66 (Type 3R, 3, 12, 4, 4X) Handle with or without test mode Padlockable handle for up to three padlocks 6 auxiliary contacts can be added Suitable as service entrance disconnecting means (UL 98) Suitable as at-motor disconnecting means (UL 508) 4 Rockwell Automation Publication 194R-SG003E-EN-P - February 2016

Specifications Fused Disconnect Switches for UL Class Fuses and CSA HRCI-J Electrical Ratings Cat. No. 194R-C30-1753 194R-J30-1753 194R-J60-1753 CSA Fuse Type/UL Fuse Type Class CC/HRCI-MISC (1) Class J/HRCI-J Class J/HRCI-J Maximum Fuse Cartridge Size [A] 30 30 60 Maximum Voltage, AC [V] 600 600 600 Maximum Voltage, DC [V] 250 250 250 Ampere Rating [A] 30 30 60 Maximum Short Circuit Prospective Fault Current [ka] 200 200 200 Fuse Operating Characteristics Time Delay Non-Time Delay Time Delay Non-Time Delay Time Delay Non-Time Delay Maximum Hp, 3-Phase AC 200V, 60 Hz [Hp] 5 3 7.5 3 15 7.5 240V, 60 Hz [Hp] 5 3 7.5 3 15 7.5 480V, 60 Hz [Hp] 10 5 15 5 30 15 600V, 60 Hz [Hp] 10 7.5 20 7.5 50 15 Maximum Hp, 1-Phase AC 120V, 60 Hz [Hp] 0.75 0.5 2 0.5 3 1.5 240V, 60 Hz [Hp] 2 1.5 3 1.5 10 3 Maximum Hp, DC 125V DC [Hp] 2 3 3 2 5 5 250V DC [Hp] 3 5 5 5 10 10 (1) Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947-3 and UL 98. Electrical Ratings Cat. No. 194R-J100 194R-J200 194R-J400 194R-J600 194R-L800 Rated Current [A] 100 200 400 600 800 Standards Compliance UL 98, CSA22.2, No. 4 Ratings per UL/CSA Maximum Voltage, AC [V] 600 Maximum Voltage, DC [V] 250 Maximum Short Circuit Fault Current [ka] 200 100 100 100 100 Fuse Type UL J J J J L CSA HRCI-J HRCI-J HRCI-J HRCI-J HRCI-L Max. Fuse Rating [A] 100 200 400 600 800 Max. Hp Rating, 3-phase 240V [Hp] 30 60 125 200 200 480V [Hp] 60 125 250 500 500 600V [Hp] 75 150 350 500 500 Max. Hp Rating, DC 125V, 2 poles in series [Hp] 7.5 15 20 240V, 3 poles in series [Hp] 20 40 50 Rockwell Automation Publication 194R-SG003E-EN-P - February 2016 21

Specifications Mechanical Data Cat. No. 194R-J30-1753 194R-J60-1753 Degree of Protection (per IEC 60947-3), Switch Only IP20 IP20 Degree of Protection (per IEC 60947-3), Switch with Terminal Shield & Fuse Carriers IP20 IP20 Mechanical Endurance (1) Operations 10 000 10 000 Operating Torque (Maximum) N m 3.5 3.5 lb in 35 35 Terminal Capacity, Power Terminals mm 2 2.5 10 2.5 25 AWG #14 #8 #14 #4 Terminal Capacity, Auxiliary Contact Terminals mm 2 2.5 4 2.5 4 AWG #14 #12 #14 #12 Maximum Number of Auxiliary Circuits 6 6 Approximate Weight kg 0.92 1.32 lbs 2.03 2.9 Height [mm (in.)] 248 (9-3/4) 248 (9-3/4) Minimum Enclosure Size Width [mm (in.)] 171 (6-3/4) 197 (7-3/4) Depth [mm (in.)] 148 (5-13/16) 148 (5-13/16) Switch Dimension Reference (See dimension drawings.) A1 B1 (1) Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947-3 and UL 98. Electrical Ratings Cat. No. 194R-J100-1753 194R-J200-1753 194R-J400-1753 194R-J600-1753 194R-L800-1753 Degree of Protection (per IEC 60947-3), Switch Only IP20 IP20 IP20 IP20 IP20 Degree of Protection (per IEC 60947-3), Switch with Terminal Shield & Fuse Carriers IP20 IP20 IP20 IP20 IP20 Mechanical Endurance (1) Operations 10 000 8 000 6 000 5 000 5 000 Operating Torque (Maximum) N m lb in mm 2 300 MCM 600 MCM; 2 x 300 MCM 2 x 600 MCM 2 x 600 MCM Terminal Capacity, Power Terminals #12 #10 Solid Cu AWG #12.#1 stranded #6 #2 or 2 x #6 2 x #2 2 x #2 Terminal Capacity, Auxiliary Contact Terminals mm 2 2.5 4 2.5 4 2.5 4 2.5 4 2.5 4 AWG #14 #12 #14 #12 #14 #12 #14 #12 #14 #12 Maximum Number of Auxiliary Circuits 4 8 8 8 8 Approximate Weight kg 2.4 3.6 4.85 20 20 lbs 5.3 7.9 10.7 44 44 Height [mm (in.)] 406 (16) 610 (24) 1000 (39.4) 1219 (48) 1219 (48) Minimum Enclosure Size Width [mm (in.)] 610 (24) 508 (20) 800 (31.5) 914.5 (36) 914.5 (36) Depth [mm (in.)] 152 (6) 152 (6) 200 (11.8) 305 (12) 305 (12) Switch Dimension Reference (See dimension drawings.) F5 F6 F7 F8 F8 (1) Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 60947-3 and UL 98. 22 Rockwell Automation Publication 194R-SG003E-EN-P - February 2016

Approximate Dimensions Figure 8 - Cat. No. 194R-J400, Frame Size F7 UL/CSA Fused Disconnect Switches 7.08 180 4.37 111.1 10.19 (3P) - 12.79 (4P) 259 (3P) - 325 (4P) 3.98 101.25 7.97 202.5 15.35 390 9.44 240 3.98 101.25 2.95 75 0.98 24.9 2.95 75 3.26 83 2.59 66 2.59 66 Figure 9 - Cat. No. 194R-J600, -L800, Frame Size F8 UL/CSA Fused Disconnect Switches min 10.43 min 265 9.84 250 6.10 155 3.12 79.5 0.43 11 fix 11.18 (3P) - fix 14.88 (4 fix 284 (3P) - fix 378 (4 2.56 1.34 65 34 0.27 7 3.54 90 0.27 7 11.81 300 10.23 260 fix 9.8 fix 25 5 126.5 18.54 471 3.36 85.5 14.96 380 0.27 7 2.32 59 11.81 300 3.36 85.5 Ø 0.51 Ø13 2 51 3.7 3.7 94 94 14.33 (3P) - 18.03 (4P) 364 (3P) - 458 (4P) 0.35 9 38 Rockwell Automation Publication 194R-SG003E-EN-P - February 2016