Guidelines How To Wire DRH Modules

Similar documents
Guidelines IDRANet Wiring Structure & Testing

Electrical Safety Part I

Australian Wiring Instructions:

Modern Soft Edged White Moulded Wiring Accessories

ANZI Transfer Switch and Generator Wiring Installation Addendum

Technical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P

titan Street lighting cut outs fused products

Installation & User Instructions

Service Entrance Methods

Electrical Safety Part II

Safety Lampholders and Pendants

2x 10W LED Slimline Floodlight Twin Flood

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

25W LED Cross Bezel Bulkhead Light

CHAPTER 2: ELECTRICAL SAFETY

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

INSTALLATION & OPERATING MANUAL LIGHT SABER LED SHAFT LIGHTING SYSTEM EN81-20 INNOVATION NOT IMITATION!

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

10W LED Die Cast Small Rectangle Bulkhead Light

MK Electric IP Solutions

Ryder Towing Equipment Ltd Alvanley House, Alvanley Industrial Estate Stockport Road East, Bredbury, Stockport SK6 2DJ

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

8300 Series Installation Guidelines

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Electrical Energy and Power Ratings

INFRESCO-S-4kW X20034 Issue: 7

LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT. Installation Instructions

The Impact of the 18 th edition (BS 7671:2018)

18W Low Energy. instructions. Instructions

Electrak power track underfloor power distribution systems

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 NOVEMBER 2009

Operating & Maintenance Instructions Thermobend Elite Range

Electrak powertrack / underfloor busbar system

Electric Vehicle Infrastructure: What does it mean for Electrical Wholesalers

adaptable, reliable underfloor power

5300 Series Installation Guidelines

Mightylite Elite 16W LED Wall Light with PIR

- Wiring Brochure Zone Manager 335

Effective discrimination of protective devices

- Wiring Brochure Zone Manager 336

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER

CARAVAN. Tow Vehicle Requirements Instructions. Various Models with 12-pin Plug. Fitting Time: 30 minutes

USER MANUAL PNEUMATIC TIME DELAY SWITCH

White Moulded. Wiring Accessories

NZQA registered unit standard version 1 Page 1 of 5

6 x 10 Belt Disc Sander

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

RM moveit. Instruction Manual. Notebus -IC. Notebus + Notebus (LAP16-17H IC) (LAP16-17H EPM) (LAP16-17H B)

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Using Electricity. Prepared in Jan 1999 Second editing in March 2000

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Underfloor to desk 231

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

IP44 - IP66 Rated RCD, Power & Cable Management

Wilkins Safety Group

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

Condensation monitor

24 Hour Immersion Heater Time Controller

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

Cellwatch Electrical Installation

ACE Variable Frequency Drive System

Technical Data. 13 Amp Fused Connection Units

INSTALLATION I N S T R U C T I O N S

TRANSMISSION SYSTEMS

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

Chapter 21 Practical Electricity

K25000 & KD25000 Series

Technical Data. Round Pin And Export Socket Outlets. Brief product description: Features:

The Management of Electrical Safety in Quarries, Associated Plant and Equipment

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Arena-Walsall power track system standard

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Actionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership

Accessory Kit Estimated Fitting Time: 120 Minutes

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Switches 7.2. Bell push 7.2. Sockets 7.3. Fused Connection Units 7.4. Additional products 7.4. Metalclad Boxes 7.5. Metalclad 7.1

Connection Accessories for small Burner Controls

I n s t a llat ion & O p e r atin g In s truc t ions

DOMINO Series surface mounting IP55

Adjustable Pneumatic Time Delay Switch

Duo water control system

3000W Dusk to Dawn Light Controller

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

Write the differences between Electric Line Tester and Screw Driver. When the light of Electric Line Tester glows?

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Domae. The right solution for distribution boards

CHAPTER 3 DOMESTIC ELECTRICITY

Trade of Metal Fabrication. Module 1: Basic Fabrication Unit 15: Electricity Phase 2

LED emergency exit signage from Channel Safety Systems

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ADS7 AC Contactor Starters

18TH EDITION BS7671 HOW THIS AFFECTS YOU. BITESIZE II. wylexreasons.co.uk WHY CHOOSE ANYTHING LESS?

Date received into service; / /.

Measurements are expressed in millimeters.

EARTHING YOUR QUESTIONS ANSWERED

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Transcription:

Guidelines How To Wire DRH Modules NOTE: This document mainly provides guidance on wiring in relation to mains (domestic electricity supply) switching applications for this module. The guidelines are based on UK electrical fittings and UK electrical regulations. Installers in other countries will recognise similar basic principles but must consult and adapt to their own regulations w: www.idratek.com The information in this document is provided for guidance only. IDRATEK Ltd reserve the right to make any necessary changes, without notice, in order to improve the quality of their products. Oct 2008-1 -

Choice of UK pattress It is recommended that a single UK style pattress box of 35mm or deeper is used. The one illustrated on the left has lugs top and bottom as well as left and right. These must be removed or the pattress replaced with one which has lugs only on the left and right. Pattress with 4 fixing lugs Ideal 2 lug pattress The DRH Module The DRH module has two relays capable of switching 13A, but should be de-rated for highly inductive loads. These relays are not fused and therefore the circuit must provide this protection with an external device. The DRH module is shown below, with an isolating shroud that separates the mains and low voltage. DRH001 rear view DRH insulating shroud Preparing the pattress The holes in the pattress are knocked out as required and rubber grommets fitted. It is easier to remove all the knockouts you require at this stage, rather than when the box is mounted in the wall. The shroud can be cut to better accommodate IDRANet/Digital input cable entry from the chosen hole in the pattress. Pattress knock outs and grommet DRH insulating shroud Oct 2008-2 -

Low Voltage Wiring The IDRANet cable must enter from the bottom of the pattress alongside any low voltage wiring that is used for the digital inputs on the DRH (e.g. window contacts also enter via this path). This is to ensure the separation between low voltage and mains wiring is maintained. Failure to do so, which results in any low voltage wiring being exposed to the mains, MUST BE AVOIDED AT ALL COSTS!!. Wiring the Ring Main Spur Mounted to the left of the DRH, is a dual pattress capable of fitting two single outlets. This is on the assumption that both relay channels are to be used. For a single switching scheme, a single pattress can be used to house a single (network controlled) socket. A further single pattress is used to house the fuse and spur switch which must be included. The picture below shows the ring mains wiring connected to the fused spur switch on the feed side. Oct 2008-3 -

A connection is made from the neutral terminal to each socket using suitably rated wire (2.5mm 2 should be used for a 13A fuse). A connection is made from the fused live terminal (and not ring main live terminal) again using suitably rated cable to the common (CMN) relay terminals on the DRH module. If both relays are to be used, then both CMN terminals should be connected as below. Oct 2008-4 -

It is most likely that the DRH is used to switch power to the socket, hence each relay is wired via the normally open connection (NO) to each connection on the back of the socket. In the highly unlikely and not recommended event of using the relays to turn off power then the normally closed (NC) terminal should be used. Fitting the Earth Wiring It is extremely important that an earth connection is made from the fused spur switch (i.e. the ring main) to the socket outlets and that all pattress boxes are earthed, including the DRH pattress on the right. In the UK the wiring should be done in accordance with the 16 th Edition Wiring Regulations and to comply with Part P of the building regulations. An appropriate inspection or certified installer should be sought. Oct 2008-5 -

The completed assembly is shown below, illustrating the feed from the ring main (top left), a circuit protection device such as a suitable rated fuse, a switch allowing this spur to be isolated and a neon indicator showing when the spur is live. In addition, the two mains outlets are shown which are now under full control of the DRH module via IDRANet. Additional Notes 1. All interlinking wiring should be rated and comply with current wiring regulations. If in doubt consult a qualified electrician. 2. The socket outlets may be of the switched variety. 3. The Cat5 cable should be protected with suitable capping up to the pattress (not shown). 4. If the DRH is fed off the lighting circuit (e.g. only intended to be used to switch table lamps) then the sockets should not 13A mains outlets, but 5A outlets characterised by their smaller round pins (in the UK). This makes it clear that only low power appliances can be plugged in. (Check current wiring regulations). 5. Suitable conduit (round) should be placed between the pattresses during first fix to allow the wires to be connected between the pattresses during second fix. Oct 2008-6 -