Open Chassis Star-Delta Starter User Guide

Similar documents
SDS Enclosed Star-Delta Starter User Guide

HIB Enclosed Inverter User Guide

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Installation Manual for DC Injection Brake Units

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

ADS7 AC Contactor Starters

Product Brochure. The motor speed control experts. AC motor speed control products and peripherals for the motion and automation control industries

RVS-AX Instruction Manual

Application Description

Low cost, internally bypassed non optimizing soft starter

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Manual for Inverter system type PCI05

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

ICG Switchgear Price List 2009

DFE. Fairford low cost, internally bypassed non-optimizing Soft Starter

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

MAGNETIC MOTOR STARTERS

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

CI-TI Contactors and motor starters Types CI 61 - CI 98

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

1 Phase electronic contactor (SC 1)

REVISED ATM72 Auto Transfer Module

Switching DC Power Supply

SOLSTART Instruction Manual

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Motor Starting Solutions Open Type Version, in Kit Form

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

USERS MANUAL MCD REMOTE OPERATOR

MCD Pump Application Module

ROBICON W120 enclosed drive

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3)

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Product Description. Application Description

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

CI-TI Contactors and Motor Starters Type CI 6-50

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Appendix: Safety and application notes for... 15

MaxPak Plus Analog DC V S Drive

Synergy EN product information

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

Reduced Voltage Motor Starters

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

Technical Information

Softstarters Type PSS. Softstarters. General information

1.1 Caution Statements

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

ELECTRICIAN S THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

ACCESS Always replace the cover panel on the unit after gaining access to the electrical connections.

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

EST Electrical Service Technician Answer Schedule

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01


RVS-DN Digital Reduced Voltage Motor Starter

Installation Instructions

Fincor Series 2230 MKII/2240

Softstarters Softstarters

Enclosed motor starters

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

WARRANTY INFORMATION...

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Dimensions WxHxD [mm] Weight [kg]

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

AUE-AUD-AU2E AU2D-AUED

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Softstarter Intelligent Controllers

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET

Contactor Types CI 61-98

Transcription:

Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1

Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation... 8 www.motorcontrolwarehouse.co.uk Copyright Motor Control Warehouse October 2017 Revision V2.0.0 SDS Open Chassis Star-Delta Starter User Guide

1 Safety information Safety Information This chapter provides very important information so that you can use the SDS Open Chassis Star-Delta Starter safely, prevent injury or death, or damage to equipment. Please read this information thoroughly and make sure you observe all the safety information shown below and elsewhere in this manual. Please make this User Guide available for the end user. Safety symbols Danger: Danger of electrical shock which can cause injury or death, or damage to equipment Warning:Potential hazard, other than electrical, that can cause physical injury or damage to equipment Danger The SDS Open Chassis Star-Delta Starter should ONLY be installed, commissioned and maintained by qualified and competent personnel. The OC SDS must be installed to the latest IEE wiring regulations taking into account local regulations. Dangerous voltages are present when the input power supply is connected to the OC SDS. Before attempting any work on the OC SDS or motor, isolate and lock off the input power supply. Prove dead using a voltage tester. The voltage tester itself should be proved immediately before and after testing using a proving unit with a low power output. The OC SDS backplate must be connected to system ground using the earth terminals. The size of the earth conductor and earth loop impedance must comply with national and local electrical regulations. The SDS is a non-field repairable unit. Contact the supplier of the SDS. The mains supply and control supply to the OC SDS must be protected by suitable rated fuses/mcbs. Warning All machinery, in which this OC SDS is used, within the European Union, must comply with directive 98/37/EC, Safety of Machinery. Do not install the OC SDS in an explosive environment. The motor must be used within the manufacturers guidelines. Do not allow conductive material to enter the components within the OC SDS, e.g. from drilling during installation. Open Chassis Star-Delta Starter User Guide P a g e 1

2 Technical Specification Technical data Trip Class 10 Model kw rating Input phase Input voltage (VAC) Max allowed motor current (A) Motor current (A) (overload range) Trip Class 10 Overload range (A) SDS075OC400V10 7.5 3 400 17 15.5 to 22 9 to 13 16 SDS11OC400V10 11 3 400 22 20 to 31 12 to 18 20 SDS15OC400V10 15 3 400 29 29 to 43 17 to 25 27 SDS185OC400V10 18.5 3 400 36 29 to 43 17 to 25 34 SDS22OC400V10 22 3 400 44 39.5 to 55 23 to 32 41 SDS30OC400V10 30 3 400 59 52 to 69 30 to 40 55 SDS37OC400V10 37 3 400 75 63 to 86 37 to 50 72 SDS45OC400V10 45 3 400 89 82 to 112 48 to 65 86 Trip Class 20 Model kw rating Input phase Input voltage (VAC) Max allowed motor current (A) Motor current (A) (overload range) Trip Class 20 Overload range (A) Typical Motor (A) Typical Motor (A) SDS075OC400V20 7.5 3 400 17 15.5 to 77 9 to 45 16 SDS11OC400V20 11 3 400 22 15.5 to 77 9 to 45 20 SDS15OC400V20 15 3 400 29 15.5 to 77 9 to 45 27 SDS185OC400V20 18.5 3 400 36 15.5 to 77 9 to 45 34 SDS22OC400V20 22 3 400 44 15.5 to 77 9 to 45 41 SDS30OC400V20 30 3 400 59 31 to 155 18 to 90 55 SDS37OC400V20 37 3 400 75 31 to 155 18 to 90 72 SDS45OC400V20 45 3 400 89 31 to 155 18 to 90 86 SDS55OC400V20 55 3 400 108 31 to 155 18 to 90 98 SDS75OC400V20 75 3 400 135 31 to 155 18 to 90 129 SDS90OC400V20 90 3 400 170 103 to 206 60 to 120 158 NOTE: The thermal overload setting is set to minimum as default. It should be adjusted to suit the motor used. To calculate the thermal overload setting = Actual motor nameplate current 1.7 x 1.1 (10% safety margin to prevent spurious tripping). NOTE: Due to the large range of the thermal overloads on the Trip Class 20 star delta starters, please make sure the thermal overload is adjusted correctly to suit the motor. NOTE: Starting the motor more than once every 10 minutes will alter the thermal overload tripping characteristic by heating the current sensing elements, making the overload trip more quickly for a given setting. P a g e 2 Open Chassis Star-Delta Starter User Guide

2 Technical Specification Approvals CE approval Environment *Model dependant OC SDS Dimensions Model Altitude Operating Temperature Max. Humidity Vibration Storage Temperature Running Environment Supported Power Supply Systems OC SDS Enclosure Supply frequency 1000m rated 1000m~3000m, 1% rated current de-rating per 100m above 1000m 10 C~+40 C 90%RH, non-condensing 5.9m/s 2 (0.6g) 40 C~+70 C Non-flammable, No corrosive gasses, no contamination with electrically conductive material TT & TN IP20 (must be installed in an enclosure) 50 to 60Hz Supply voltage 3 phase 400VAC ±10% *Contactor coil voltage 400VAC / 240VAC / 110VAC (+/-10%) Dimensions (H x W x D) Trip Class 10 Dimensions (H x W x D) Trip Class 20 Approx. Weight (kg) SDS075OC400V 170 x 180 x 170 170 x 180 x 170 2.2 SDS11OC400V 170 x 180 x 170 170 x 180 x 170 2.2 SDS15OC400V 200 x 300 x 190 200 x 300 x 190 5 SDS185OC400V 200 x 300 x 190 200 x 300 x 190 5 SDS22OC400V 200 x 300 x 190 200 x 200 x 200 5 SDS30OC400V 200 x 320 x 200 200 x 320 x 200 5 SDS37OC400V 200 x 320 x 200 200 x 320 x 200 5 SDS45OC400V 200 x 320 x 200 200 x 320 x 200 5 SDS55OC400V 200 x 320 x 200 5 SDS75OC400V 350 x 480 x 150 10 SDS90OC400V 350 x 480 x 150 10 NOTE: The above dimensions are only approximate and do not take into account the size of the thermal overload on the trip class 20 star delta starters. NOTE: The contactor sets between the Trip Class 10 and Trip Class 20 open chassis star delta starter may differ hence the physical size of the trip class 20 may be larger than the equivalent trip class 10 model. NOTE: The open chassis star delta starters are supplied pre-wired on a back plate. The starting and stopping method will need wiring into the star delta starter. See Control Connections & Operation section of this User Guide for example connections. NOTE: The thermal overload is fitted into the output of the main contactor on the Trip Class 10 product. The Trip Class 20 thermal overload is supplied as a separate module which will need to be mounted separately from the contactors and wired into the output of the main contactor. Open Chassis Star-Delta Starter User Guide P a g e 3

2 Technical Specification SDS Trip Class The MCW open chassis star delta starters are fitted with either a Trip Class 10 thermal overload relay as which is suitable for the majority of light to medium industrial type load applications or a Trip Class 20 thermal overload relay which is suitable for medium to heavy industrial loads. The MCW star delta starter range is not suitable for applications that have a very heavy load on start that takes greater than 20s to start or very high inertia loads such as high inertia fans, centrifuges or loaded crushers. Starting the MCW star delta starters more than once every 10 minutes will alter the thermal overload tripping characteristics making the overload trip more quickly for a given thermal overload current setting. Trip Class Explained At 600% of the maximum current rating of the motor the Trip Class 10 unit will trip in 10 seconds or less, Trip Class 20 will trip in 20 seconds or less, and Trip Class 30 will trip in 30 seconds or less. The class number indicates the thermal overload trip characteristics from cold state. Ir = Current setting of overload relay. This should be the Full Load Current (FLC or FLA) shown on motor rating plate. 1.05 x Ir 1.2 x Ir 1.5 x Ir 7.2 x Ir Time to trip from a cold start Trip Class 10 >2 hours <2 hours <4 minutes 2s< to <10s Trip Class 20 >2 hours <2 hours <8 minutes 2s< to <20s Trip Class 30 >2 hours <2 hours <12 minutes 2s< to <30s NOTE: The open chassis star-delta starter can only be used with motors which have 400V delta and 690V star windings. They cannot be used with motors that have 200V delta and 400V star windings. P a g e 4 Open Chassis Star-Delta Starter User Guide

3 Supply & Motor Connections Open Chassis SDS Circuit diagram with Main and Star contactors closed This is equivalent to connecting the motor in the star 690V configuration. This is the start configuration for the motor. This configuration draws less current from the mains supply during starting then if the motor was started in the delta configuration. 400V 3 phase mains supply Input (Connect to top of main contactor) L1 L2 L3 Main contactor - Closed Delta contactor - Open Star contactor - Closed Thermal Overload U1 V1 W1 V2 W2 U2 Motor terminal box U1 V1 W2 U2 Connect to delta contactor output The motor cables should be connected to the open chassis SDS star and delta contactors as per the diagram W1 V2 Equivalent to - Motor terminals connected in star L2 Star winding connection 400V 3 phase mains supply L1 L2 L3 U1 V1 W1 W2 U2 V2 Star point L1 U1 U2 V2 W2 V1 L3 W1 NOTE: Please remember to remove the shorting bars from the motor terminals as these are not required with a star-delta starter. Open Chassis Star-Delta Starter User Guide Page 5

3 Supply & Motor Connections Open Chassis SDS Circuit diagram with Main and Delta contactors closed This is equivalent to connecting the motor in the delta 400V configuration. The delta connection is the running connection for the motor. 400V 3 phase mains supply input (Connect to top of main contactor) L1 L2 L3 Main contactor - Closed Delta contactor - Closed Star contactor - Open Thermal Overload U1 Connect to thermal V1 W1 overload output V2 W2 U2 Motor terminal box U1 W2 V1 U2 Connect to delta contactor output The motor cables should be connected to the open chassis SDS star and delta contactors as per the diagram W1 V2 Equivalent to - Motor terminals connected in delta Delta winding connection 400V 3 phase mains supply L1 L2 L3 U1 V1 W1 W2 U2 V2 L1 L2 L3 U2 V1 U1 W2 V2 W1 NOTE: Please remember to remove the shorting bars from the motor terminals as these are not required with a star-delta starter. Page 6 Open Chassis Star-Delta Starter User Guide

3 Supply & Motor Connections Open Chassis SDS Circuit diagram Example (400VAC control) Open Chassis Star-Delta Starter User Guide Page 7

4 Control Connections & Operation Control Connections The following drawings give examples of how to connect volt free contacts, switches or push buttons to control the starting and stopping of the open chassis star delta starter. Small Open Chassis Star-Delta Starter WITH Aux Contact Block on Contactor K3 Controlled by an external normally open relay contact Controlled by external Start/Stop buttons Large Open Chassis Star-Delta Starter WITHOUT Aux Contact Block on K3 Controlled by an external normally open relay contact L1 Thermal O/L relay (95) (96) External control relay K2 K1 (21) Timer or (55) K1 Timer (56) L2/N Contactor A1 (common of K1, K2, K3) Connect a wire between K1 Timer (55) and K1 NO (13) Page 8 Open Chassis Star-Delta Starter User Guide

Controlled by external Start/Stop buttons 75kW & 90kW Open Chassis Star-Delta Starter Controlled by an external normally open relay contact L1 Thermal O/L relay (95) (96) External control relay K2 K1 (21) Timer or (55) K1 Timer (56) L2/N Contactor A1 (common of K1, K2, K3) Connect a wire between K1 Timer (55) and K1 NO (163) Controlled by external Start/Stop buttons Open Chassis Star-Delta Starter User Guide Page 9

4 Control Connections & Operation Operation When start button/switch is pressed on the star-delta contactors will initiate starting the motor. The Main and Star contactors will pull in. The supply voltage (400VAC) is connected across the star connected motor. Because the motor is connected in star which is the 690V winding but with only 400V across it, the current the motor draws during starting will be reduced. After the time delay of the timer elapses, the Star contactor will drop out and the Delta contactor will pull in. Now the motor will be connected in its delta (running) winding with 400V across its windings. Timer Setting The timer setting is dependent on the driven load and inertia and can be determined as follows: There are two basic ways of determining the correct point at which the timer should change the winding configuration from 'star' (starting mode) to 'delta' (running mode). Both methods determine the point at which the rotor has achieved its maximum speed in star, and therefore the point at which the starter should change to delta. Current measurement method Set the delta timer to its maximum setting. Put a clip-on ammeter on one of the lines FEEDING the starter. Set a stopwatch going when you press the start button. Watch the ammeter - it will peak immediately on start up, then the current will drop off as the load accelerates. As soon as the current steadies off, stop the watch. At this point (approximately 85% full load speed) the motor can achieve nothing more by remaining in star, and this is the latest point in time that delta changeover should be made. Speed measurement method Use a tachometer on the motor shaft (mechanical or optical) to measure motor speed. Set the delta timer to its maximum setting. Again, use a stop watch. Observe the Tacho. Acceleration characteristics will vary dependent on the driven load, but the speed will settle out at approx. 85% full load speed (this can usually be heard by the tone in the motor being constant). Stop the watch at this point. Set the timer to the time recorded on the stop watch. Page 10 Open Chassis Star-Delta Starter User Guide

NOTES Date Thermal Overload Setting Open Chassis Star-Delta Starter User Guide Page 11

NOTES Page 12 Open Chassis Star-Delta Starter User Guide

Other Enclosed Products from Motor Control Warehouse Enclosed Star Delta Starters, three phase input from 7.5kW to 110kW. Rated for light to medium or medium to heavy industrial loads. Features IP65 Powder coated steel enclosure Lockable panel door Interlocked mains isolator 10kA MCBs or 80kA fuses on power 10kA MCBs on control Tri rated cable Motor outputs to terminals Terminals for external stop/start Key release E-Stop button Adjustable changeover timer Motor thermal overload relay (trip class 10 or trip class 20) Open Chassis Star-Delta Starter User Guide Page 13

Other Enclosed Products from Motor Control Warehouse Enclosed Inverter Drives, single phase input from 1.5kW to 4kW. Three phase input from 0.75kW to 37kW. Features IP54 powder coated steel enclosure Interlocked mains isolator 10kA MCBs power & control Tri rated cable Keyed Inverter Disable button IP rated speed pot Motor connections to terminals Fwd/Rev switch Stop/Start buttons Indication lamps Thermostat controlled cooling fans HD700 industrial inverter Enclosed Soft Starters, from 7.5kW to 55kW, three phase input. All these products are rated at trip class 10 (medium industrial loads). Features IP65 Powder coated Steel enclosure 10kA MCBs power & control Interlocked mains isolator Motor thermal overload relay Internal bypass contactor Stop/start pushbuttons Keyed soft stop button Running and healthy lamps Customer terminals 24Vdc power supply Tri rated cable Fairford Electronics DFE Soft Start www.motorcontrolwarehouse.co.uk