Coils for solenoid valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Similar documents
MAKING MODERN LIVING POSSIBLE. Coils for solenoid valves. Technical brochure

Solenoid coil Types BB, BE, BF, BG, and BN

Solenoid coil for control in potentially explosive areas Type BZ

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Solenoid valves. Solenoid valves, type PKVD Solenoid valves, type EVR NC / NO

Solenoid valves Type EVU

Solenoid coils. Data sheet

Solenoid coils. Data sheet

Solenoid valves, type EVRA 3 40 and EVRAT REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Coils for solenoid valves

Solenoid valves type EVRA 3 to 40 and EVRAT 10 to 20

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

2/2-way assisted lift operated solenoid valve type EV250B

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

Electric expansion valve Type AKV 10P, AKV 10PS

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Assisted lift operated 2/2-way solenoid valves Type EV250B

Solenoid valves REFRIGERATION AND AIR CONDITIONING. Fitters notes

Solenoid valves type EVSA 25 50

Solenoid valves for drinking water Types EV220BW and EV228BW

Installation EVRA 32 & 40 precautions When pressure testing The coil The correct product... 18

S40 Series. - 1/4" NPT - Stainless Steel Body - 2-Way Piloted Piston - Normally Open. Dimensions/Weight

Pilot valves for servo operated main valves

Assisted lift operated 2/2-way solenoid valves Type EV251B

Servo-operated 2/2-way solenoid valves for steam Type EV225B

Pilot valves for servo operated main valves

S21 Series. - 1" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

PRODUCT DATA HDF SERIES Solenoid Valve

FA + solenoid valve Type ICF 15/20 EVRAT

Servo-operated 2/2-way solenoid valves for high pressure

Solenoid valves Type EVU for fluorinated refrigerants

S21 Series. - 2" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

International approvals.

Solenoid valves type EVR 2 40 NC / NO

Solenoid valve Types EVR 2 EVR 40 NC/NO

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

Unused flameproof threads for cable glands have to be closed with certified plugs.

Pilot valves for servo opereated main valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Electric expansion valve for R744 (CO 2 ) Type AKVH

HS1L Interlock Switches with Solenoid

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Solenoid valves 2/2-way servo operated type EV220B 15 50

A good connection. International approvals.

MAKING MODERN LIVING POSSIBLE. Solenoid valves, 2/2-way assisted lift operated type EV251B Technical brochure

PARKER SOLENOID VALVES GENERAL PURPOSE SOLENOID VALVE SOLENOID COILS FOR GENERAL PURPOSE VALVES PARKER GP SERIES

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Easytork Solenoid Valve IOM

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

Solenoid valves for water supply and steam inlet Types EV220T, EV220W, EV220B, EV225B, and AV210

3/2-5/2 ports / positions

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

3 Way/2 Position Valves

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Solenoid Locking Safety Switches

Safety Limit Switch

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Electric Expansion Valve Type AKVO 10

Electric expansion valves Types AKVA 10, 15 & 20

HS1C Interlock Switches with Solenoid

SG-B1 SERIES / SG-A1 SERIES

Electrically operated spool valve. The manual override is detent and is operated by screw driver.

Solenoid valves EVRA and EVRAT

MAKING MODERN LIVING POSSIBLE. Solenoid valves Type EVU for fluorinated refrigerants REFRIGERATION AND AIR CONDITIONING.

HS1E-K Interlock Switches with Solenoid (3-circuit)

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Compact plastic limit switches with positive opening mechanism

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Explosion and flame-proof cast iron electric motors

Solenoid valve Types EV220B 15 - EV220B 50

Control and Terminal Box Type A21-**-*****

SKINNER Intrinsically Safe Series Four-Way

Solenoid valve Types EV220B 15 - EV220B 50

Compact plastic limit switches with positive opening mechanism

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Surface mounting, flush mounting, and DIN track mounting

Servo-operated 2/2-way solenoid valves Type EV220A

HS1E Series Full Size Solenoid Locking Switches

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Condensed Catalog 2006 North America

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Core Industrial Products for Distributors and Wholesalers in North America

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

7 Lighting Technology

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Poppet Valves Series. Keeping the World Flowing

Standard Interlock Safety Switches

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Pressure Control Type KPU

Instruction General Vacuum Valve program

Transcription:

REFRIGERATION AND AIR CONDITIONING Technical leaflet

2 RD3JE402 Danfoss A/S, 01-2005

Introduction The coils are specially designed to operate in the aggressive environment of high humidity and temperature fluctuations that you find in most refrigeration systems. The new Clip-on fastening system ensures a faultless installation and makes the coils easy to mount and dismount. A Danfoss Clip-on coil can be mounted without any tools at all, and it is simple to dismount the coil by means of a screwdriver. The Clip-on coils are available for the entire range of Danfoss solenoid valves for refrigeration, freezing and air conditioning purposes. Features Encapsulated coils with long operating life, even under extreme conditions Standard coils for a.c. or d.c. Standard coils available with 3-core cable, terminal box or DIN plugs Standard coils from 12 V to 420 V, 50, 60 or 50/60 Hz Standard coils dimensioned for max. opening differential pressure (MOPD) of up to 21 bar Coils can be fitted without the use of tools Technical data Ambient temperature 10 or 12 W a.c. coil for NC (normally closed) valve: 40 +80 C 10 W a.c. coil for NO (normally open) valve: 40 +55 C 20 W d.c. coil for NC and NO valve: 40 +50 C Permissible voltage variation 10 and 12 W a.c. coils: +10 15% and as double frequency coils: ±10% a.c. coils for 220-230 / 380-400 V: +6 15% and as double frequency coils: +6 10% 20 W d.c. coils: ±10%. Enclosure with cable or terminal box IP 20 with DIN plugs and protective cap IP 65 with DIN socket IP 00 with DIN plugs. Approvals See under the required solenoid valve. Connection 3-core cable The external thread in the screwed cable entry suits flexible steel hose or corresponding cable protection. Terminal box Leads are connected to terminal screws in the terminal box. The box is fitted with a Pg 13.5 screwed entry for 6 14 mm cable. Max. lead cross section: 2.5 mm 2. DIN plugs The three pins on the coil can be fitted with spade tabs, 6.3 mm wide (to DIN 46247). The two current carrying pins can also be fitted with spade tabs, 4.8 mm wide. Max. lead cross section: 1.5 mm 2. Use of the protective cap supplied will prevent inadvertent contact with live parts. DIN socket (to DIN 43650) Leads are connected in the socket. The socket is fitted with a Pg 11 screwed entry for 6 12 mm. Danfoss A/S, 01-2005 RD3JE402 3

Ordering Clip-on coils Valve type Voltage V Frequency Hz 1 m 3-core cable terminal box Code no. DIN plugs and protective cap IP 20 DIN plugs**) Appendix no.*) Power consumption EVR 2 40 (NC) EVR 6 22 (NO) EVRC EVRA EVRAT EVRS / EVRST EVM (NC) Direct current d.c. EVR 2 15 (NC) EVR 25 40 (NC/NO) EVR 6 15 (NO) EVRC 10 15 EVRA 3 15 (NC) EVRA 25 40 (NC) EVRAT 10 15 (NC) EVRS / EVRST 3 15 EVM (NC/NO) Direct current d.c. EVR 20 22 (NC/NO) EVRC 20 EVRA 20 EVRAT 20 EVRST 20 12 50 018F6256 018F6706 018F6181 15 24 50 018F6257 018F6707 018F6182 018F7358 16 42 50 018F6258 018F6708 018F6183 17 48 50 018F6259 018F6709 018F6184 18 115 50 018F6261 018F6711 018F6186 018F7361 22 220-230 50 018F6251 018F6701 018F6176 018F7351 31 240 50 018F6252 018F6702 018F6177 018F7352 33 380-400 50 018F6253 018F6703 018F6178 37 420 50 018F6254 018F6704 018F6179 38 24 60 018F6265 018F6715 018F6190 14 115 60 018F6260 018F6710 018F6185 20 220 60 018F6264 018F6714 018F6189 29 240 60 018F6263 018F6713 018F6188 30 110 50/60 018F6280 018F6730 018F6192 018F7360 21 220-230 50/60 018F6282 018F6732 018F6193 018F7363 32 12 018F6856 01 24 018F6857 02 48 018F6859 04 110 018F6860 06 115 018F6861 07 220 018F6851 09 12 018F6886 01 24 018F6887 02 48 018F6889 04 110 018F6890 06 220 018F6881 09 10 W 21 VA 44 VA Coil type I 20 W Coil type II 20 W See "Opening differential pressure" under "Technical data" for the valve concerned. *) Indicates voltage and frequency **) Can only be used with DIN socket ***) When replacing a coil with terminal box, it is sufficient to change the coil unit itself. Therefore, order coil with DIN plugs and protective cap. 4 RD3JE402 Danfoss A/S, 01-2005

Ordering (Continued) Code no. Special coils Valve type Voltage V Frequency Hz terminal box Appendix no. Indicates voltage and frequency Power consumption EVR 3 40 EVRC EVRA EVRAT EVRS / EVRST EVM (NC / NO) 24 50 018F6807 16 42 50 018F6808 17 48 50 018F6809 18 110 50 018F6811 22 220-230 50 018F6801 31 240 50 018F6802 33 380-400 50 018F6803 37 24 60 018F6815 14 110 60 018F6813 20 220 60 018F6814 29 12 W 26 VA 55 VA See "Opening differential pressure" under "Technical data" for the valve concerned. When replacing a coil with terminal box, it is sufficent to change the coil unit itself. Therefore, order coil with DIN plugs and protective cap. Accessories Description DIN socket Terminal box with build-in light emmiting indicator diode for solenoid valves Code no. 042N0156 018Z0089 Dimensions and weights See under the required solenoid valve. Danfoss A/S, 01-2005 RD3JE402 5

Introduction Danfoss has developed a series of ATEX approved coils for use in EX zone 2. The coils are equipped with clip-on fastening system for easy and faultless installation. Thus the coil can be installed without use of tools and easily dismounted by means of a screwdriver. Features ATEX approved for use in EX zone 2 Embedded coils with long lifetime - even under extreme conditons Available with 1 m 3-core cable or terminal Quick and safe mounting with "clip-on"coil Mounting on valve without use of tools Standard coils for a.c. and d.c. Standard coils from 24 to 240 V Standard coils dimensioned to max. opening differential pressure (MOPD) up to 21 bar Approval EExnAIIT3 DEMKO 01 ATEX 130591X Technical data Ambient temperature 11 or 14 W, 50 Hz a.c. coil 40 +50 C 13 W, 50/60 Hz a.c. coil 25 +50 C 20 W d.c. coil 25 +50 C Temperature of medium max. 105 C Enclosure for coil Permissible voltage variation 11 and 14 W a.c. coils: +10 15% and as double frequency coils: ±10% 20 W d.c. coils: ±10% Connections 3-core cable The external thread of the cable entry is suitable for flexible steel hose or similar cable protection Terminal box The cables are connected with the terminal screws in the terminal box which is equipped with a Pg 13.5 cable gland for 6 14 mm cable. Max. cable diam.: 2.5 mm 2 6 RD3JE402 Danfoss A/S, 01-2005

Ordering Coils Type Voltage V Frequency Hz 1 m 3-core cable Code no. terminal box Power consumption EVR 2 40 (NC) EVR 6 22 (NO) EVRC EVRA/ EVRAT EVRS / EVRST EVM (NC / NO) 24 50 018F5707 230 50 018F5701 11 W 21 VA 240 50 018F5702 44 VA 230 50/60 018F5732 224 50/60 018F5727 13 W 25 VA 48 VA EVR 2 40 (NC) EVR 6 22 (NO) EVRC EVRA/ EVRAT EVRS / EVRST EVM (NC) 24 50 018F5807 110 50 018F5811 230 50 018F5801 14 W 26 VA 55 VA Direct current d.c. EVR 2 15 (NC) EVR 25 40 (NC/NO) EVR 6 15 (NO) EVRC 10 15 EVRA 3 15 (NC) EVRA 25 40 (NC) EVRAT 10 15 (NC) EVRS/ EVRST 3 15 EVR (NC/NO) 24 018F5857 20 W Must always be installed with fuse ahead of coil Danfoss A/S, 01-2005 RD3JE402 7

UL - approved coil, type GP Introduction the Danfoss general purpose coils, type GP, for solenoid valves the mounting with a "click-on". Danlok TM makes mounting faster and easier and keeps the coil safely in place. Features Easy mounting and dismounting No loose parts during operation Suitable to all standard solenoid valves Available with junction box or conduit boss Approvals S UL listed with EVR, MH 7648 A CSA certified, SA 52727 Technical data Enclosure junction box: NEMA 2 ~ IP 12-32 Conduit boss: NEMA 4 ~ IP 54 Ordering Connection Cable length Voltage Frequency Code.no Power in. V Hz consumption Junction box Conduit coil Junction box 120/208-240 50/60 018z7600 Junction box 24 50/60 018z7613 Junction box 110/120 50/60 018z7612 Junction box 208/240 50/60 018z7611 Conduit boss 18 24 50/60 018z7623 Conduit boss 18 110/120 50/60 018z7622 Conduit boss 18 208/240 50/60 018z7621 17.5 W 40 VA 76 VA 8 RD.3J.E3.02 Danfoss A/S, 04-2002